{"id":3452,"date":"2026-08-18T10:34:58","date_gmt":"2026-08-18T10:34:58","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3452"},"modified":"2026-08-18T10:35:38","modified_gmt":"2026-08-18T10:35:38","slug":"bis-certification-for-hexagon-head-bolts-is-1363-part-12023","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-for-hexagon-head-bolts-is-1363-part-12023\/","title":{"rendered":"BIS Certification for Hexagon Head Bolts \u2013 IS 1363 (Part 1)"},"content":{"rendered":"<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"12q1sue\" data-start=\"1289\" data-end=\"1303\">Introduction<\/h1>\n<p data-start=\"1305\" data-end=\"1668\">Hexagon Head Bolts are widely used fastening components in <strong data-start=\"1364\" data-end=\"1493\">construction, engineering, automobile manufacturing, machinery, fabrication, industrial equipment and structural applications<\/strong>. Their six-sided head allows tightening with a suitable wrench or socket, making them suitable for applications where a reliable and secure mechanical connection is required.<\/p>\n<p data-start=\"1670\" data-end=\"1924\"><strong data-start=\"1670\" data-end=\"1695\">IS 1363 (Part 1):2023<\/strong> specifies requirements for <strong data-start=\"1723\" data-end=\"1773\">Hexagon Head Bolts in the size range M5 to M64<\/strong>, belonging to Product Grade C. The current standard is the sixth revision and is aligned with <strong data-start=\"1868\" data-end=\"1885\">ISO 4016:2022<\/strong>.<\/p>\n<p data-start=\"1926\" data-end=\"2247\">BIS currently lists this product under the <strong data-start=\"1969\" data-end=\"1998\">Bolts, Nuts and Fasteners<\/strong> category in its Scheme-I product certification framework. The applicable regulatory framework includes the <strong data-start=\"2106\" data-end=\"2165\">Bolts, Nuts and Fasteners (Quality Control) Order, 2023<\/strong>, as amended\/supplemented by the 2024 Order.<\/p>\n<p data-start=\"2249\" data-end=\"2442\">For manufacturers of Hexagon Head Bolts, understanding the standard, product grouping, testing requirements and BIS application process is therefore important before applying for a BIS licence.<\/p>\n<hr data-start=\"2444\" data-end=\"2447\" \/>\n<h1 data-section-id=\"75334n\" data-start=\"2449\" data-end=\"2475\">About Hexagon Head Bolts<\/h1>\n<p data-start=\"2477\" data-end=\"2592\">A Hexagon Head Bolt is a mechanical fastening component with a <strong data-start=\"2540\" data-end=\"2591\">six-sided head and an externally threaded shank<\/strong>.<\/p>\n<p data-start=\"2594\" data-end=\"2668\">The hexagonal head provides a convenient surface for applying torque with:<\/p>\n<ul data-start=\"2670\" data-end=\"2716\">\n<li data-section-id=\"oxds5q\" data-start=\"2670\" data-end=\"2680\">Spanners<\/li>\n<li data-section-id=\"h2vymz\" data-start=\"2681\" data-end=\"2691\">Wrenches<\/li>\n<li data-section-id=\"1riy0fy\" data-start=\"2692\" data-end=\"2701\">Sockets<\/li>\n<li data-section-id=\"9qnte3\" data-start=\"2702\" data-end=\"2716\">Torque tools<\/li>\n<\/ul>\n<p data-start=\"2718\" data-end=\"2764\">Hexagon Head Bolts are available in different:<\/p>\n<ul data-start=\"2766\" data-end=\"2853\">\n<li data-section-id=\"yxi9c\" data-start=\"2766\" data-end=\"2780\">Thread sizes<\/li>\n<li data-section-id=\"uve61z\" data-start=\"2781\" data-end=\"2790\">Lengths<\/li>\n<li data-section-id=\"1nakryv\" data-start=\"2791\" data-end=\"2809\">Property classes<\/li>\n<li data-section-id=\"uo524w\" data-start=\"2810\" data-end=\"2821\">Materials<\/li>\n<li data-section-id=\"1a0ybtp\" data-start=\"2822\" data-end=\"2842\">Surface conditions<\/li>\n<li data-section-id=\"1dgn7wi\" data-start=\"2843\" data-end=\"2853\">Coatings<\/li>\n<\/ul>\n<p data-start=\"2855\" data-end=\"2987\">IS 1363 (Part 1):2023 specifically covers <strong data-start=\"2897\" data-end=\"2910\">M5 to M64<\/strong> Hexagon Head Bolts of Product Grade C.<\/p>\n<hr data-start=\"2989\" data-end=\"2992\" \/>\n<h1 data-section-id=\"5p84y2\" data-start=\"2994\" data-end=\"3026\">What is IS 1363 (Part 1):2023?<\/h1>\n<p data-start=\"3028\" data-end=\"3064\"><strong data-start=\"3028\" data-end=\"3053\">IS 1363 (Part 1):2023<\/strong> is titled:<\/p>\n<p data-start=\"3066\" data-end=\"3176\"><strong data-start=\"3066\" data-end=\"3176\">Hexagon Head Bolts, Screws and Nuts of Product Grade C \u2013 Part 1 Hexagon Head Bolts (Size Range M5 to M64).<\/strong><\/p>\n<p data-start=\"3178\" data-end=\"3395\">The standard specifies the characteristics and requirements for Hexagon Head Bolts made from steel, having metric coarse-pitch threads from <strong data-start=\"3318\" data-end=\"3336\">M5 through M64<\/strong> and Product Grade C.<\/p>\n<p data-start=\"3397\" data-end=\"3439\">The current BIS Product Manual identifies:<\/p>\n<ul data-start=\"3441\" data-end=\"3625\">\n<li data-section-id=\"1tiafan\" data-start=\"3441\" data-end=\"3463\">Product Grade: <strong data-start=\"3458\" data-end=\"3463\">C<\/strong><\/li>\n<li data-section-id=\"1r1opey\" data-start=\"3464\" data-end=\"3498\">Thread Size Range: <strong data-start=\"3485\" data-end=\"3498\">M5 to M64<\/strong><\/li>\n<li data-section-id=\"zkeanr\" data-start=\"3499\" data-end=\"3560\">Property Class: <strong data-start=\"3517\" data-end=\"3560\">4.6 \/ 4.8 \/ as declared by manufacturer<\/strong><\/li>\n<li data-section-id=\"1e4f470\" data-start=\"3561\" data-end=\"3625\">Sample Size: <strong data-start=\"3576\" data-end=\"3587\">6 bolts<\/strong><\/li>\n<\/ul>\n<hr data-start=\"3627\" data-end=\"3630\" \/>\n<h1 data-section-id=\"oyeus0\" data-start=\"3632\" data-end=\"3652\">Size Range Covered<\/h1>\n<p data-start=\"3654\" data-end=\"3674\">The standard covers:<\/p>\n<p data-start=\"3676\" data-end=\"3689\"><strong data-start=\"3676\" data-end=\"3689\">M5 to M64<\/strong><\/p>\n<p data-start=\"3691\" data-end=\"3871\">This means manufacturers producing Hexagon Head Bolts within this metric coarse-thread size range can seek certification according to the applicable requirements and licence scope.<\/p>\n<p data-start=\"3873\" data-end=\"4006\">The exact sizes included in a manufacturer&#8217;s licence depend on the applicable product grouping and the manufacturer&#8217;s approved scope.<\/p>\n<hr data-start=\"4008\" data-end=\"4011\" \/>\n<h1 data-section-id=\"1rny8l4\" data-start=\"4013\" data-end=\"4028\">Product Grade<\/h1>\n<p data-start=\"4030\" data-end=\"4059\">IS 1363 (Part 1):2023 covers:<\/p>\n<p data-start=\"4061\" data-end=\"4080\"><strong data-start=\"4061\" data-end=\"4080\">Product Grade C<\/strong><\/p>\n<p data-start=\"4082\" data-end=\"4237\">Grade C is intended for general-purpose fastening applications where the dimensional and performance requirements specified by the standard are applicable.<\/p>\n<p data-start=\"4239\" data-end=\"4368\">The manufacturer should clearly define the applicable product grade and property class while preparing the product documentation.<\/p>\n<hr data-start=\"4370\" data-end=\"4373\" \/>\n<h1 data-section-id=\"1xv390h\" data-start=\"4375\" data-end=\"4417\">BIS Certification for Hexagon Head Bolts<\/h1>\n<p data-start=\"4419\" data-end=\"4535\">BIS Certification confirms that the manufacturer&#8217;s product has been assessed against the applicable Indian Standard.<\/p>\n<p data-start=\"4537\" data-end=\"4834\">IS 1363 (Part 1) is currently included by BIS under <strong data-start=\"4589\" data-end=\"4601\">Scheme-I<\/strong> in the <strong data-start=\"4609\" data-end=\"4638\">Bolts, Nuts and Fasteners<\/strong> category. BIS&#8217;s current listing identifies the product as <strong data-start=\"4697\" data-end=\"4741\">Hexagon Head Bolts, Size Range M5 to M64<\/strong> and links it to the applicable Quality Control Orders.<\/p>\n<p data-start=\"4836\" data-end=\"4881\">The certification process generally involves:<\/p>\n<ul data-start=\"4883\" data-end=\"5063\">\n<li data-section-id=\"1u7zdn9\" data-start=\"4883\" data-end=\"4903\">Product assessment<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"4904\" data-end=\"4922\">Product grouping<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"4923\" data-end=\"4938\">Documentation<\/li>\n<li data-section-id=\"qc4jjs\" data-start=\"4939\" data-end=\"4955\">Sample testing<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"4956\" data-end=\"4976\">Factory assessment<\/li>\n<li data-section-id=\"1ubhgl2\" data-start=\"4977\" data-end=\"5007\">Quality-control verification<\/li>\n<li data-section-id=\"u5eurx\" data-start=\"5008\" data-end=\"5022\">BIS scrutiny<\/li>\n<li data-section-id=\"1g5zxie\" data-start=\"5023\" data-end=\"5047\">Test report evaluation<\/li>\n<li data-section-id=\"d08cwd\" data-start=\"5048\" data-end=\"5063\">Licence grant<\/li>\n<\/ul>\n<p data-start=\"5065\" data-end=\"5176\">After certification, the manufacturer must use the BIS Standard Mark in accordance with the licence conditions.<\/p>\n<hr data-start=\"5178\" data-end=\"5181\" \/>\n<h1 data-section-id=\"1n47csv\" data-start=\"5183\" data-end=\"5217\">Applicable Quality Control Order<\/h1>\n<p data-start=\"5219\" data-end=\"5328\">Hexagon Head Bolts under IS 1363 (Part 1) fall within the <strong data-start=\"5277\" data-end=\"5306\">Bolts, Nuts and Fasteners<\/strong> regulatory framework.<\/p>\n<p data-start=\"5330\" data-end=\"5567\">BIS&#8217;s current Scheme-I listing identifies <strong data-start=\"5372\" data-end=\"5397\">IS 1363 (Part 1):2019<\/strong> in the applicable product list and associates it with the <strong data-start=\"5456\" data-end=\"5515\">Bolts, Nuts and Fasteners (Quality Control) Order, 2023<\/strong> and <strong data-start=\"5520\" data-end=\"5528\">2024<\/strong>.<\/p>\n<p data-start=\"5569\" data-end=\"5769\">The current Indian Standard has subsequently been revised to <strong data-start=\"5630\" data-end=\"5655\">IS 1363 (Part 1):2023<\/strong>. BIS&#8217;s current standard database identifies the 2023 version as <strong data-start=\"5720\" data-end=\"5730\">Active<\/strong>.<\/p>\n<p data-start=\"5771\" data-end=\"5898\">Manufacturers should therefore verify the latest BIS\/QCO requirements applicable to their product before making an application.<\/p>\n<hr data-start=\"5900\" data-end=\"5903\" \/>\n<h1 data-section-id=\"1ud7n4i\" data-start=\"5905\" data-end=\"5923\">Products Covered<\/h1>\n<p data-start=\"5925\" data-end=\"5948\">The product covered is:<\/p>\n<p data-start=\"5950\" data-end=\"5972\"><strong data-start=\"5950\" data-end=\"5972\">Hexagon Head Bolts<\/strong><\/p>\n<p data-start=\"5974\" data-end=\"5996\">within the applicable:<\/p>\n<ul data-start=\"5998\" data-end=\"6131\">\n<li data-section-id=\"1b1q8ou\" data-start=\"5998\" data-end=\"6020\">M5 to M64 size range<\/li>\n<li data-section-id=\"1lr0qdx\" data-start=\"6021\" data-end=\"6038\">Product Grade C<\/li>\n<li data-section-id=\"114j0u2\" data-start=\"6039\" data-end=\"6068\">Applicable property classes<\/li>\n<li data-section-id=\"1uqcptc\" data-start=\"6069\" data-end=\"6100\">Applicable surface conditions<\/li>\n<li data-section-id=\"7lgts5\" data-start=\"6101\" data-end=\"6131\">Applicable finishes\/coatings<\/li>\n<\/ul>\n<p data-start=\"6133\" data-end=\"6235\">The final licence scope depends on the product grouping and approved manufacturing\/testing capability.<\/p>\n<hr data-start=\"6237\" data-end=\"6240\" \/>\n<h1 data-section-id=\"iw8fkq\" data-start=\"6242\" data-end=\"6278\">Applications of Hexagon Head Bolts<\/h1>\n<p data-start=\"6280\" data-end=\"6320\">Hexagon Head Bolts are commonly used in:<\/p>\n<ul data-start=\"6322\" data-end=\"6603\">\n<li data-section-id=\"13mj4o7\" data-start=\"6322\" data-end=\"6348\">Automobile manufacturing<\/li>\n<li data-section-id=\"d4k3ep\" data-start=\"6349\" data-end=\"6371\">Industrial machinery<\/li>\n<li data-section-id=\"1cdd6sf\" data-start=\"6372\" data-end=\"6396\">Construction equipment<\/li>\n<li data-section-id=\"dkkb7x\" data-start=\"6397\" data-end=\"6421\">Engineering industries<\/li>\n<li data-section-id=\"n0knt4\" data-start=\"6422\" data-end=\"6435\">Fabrication<\/li>\n<li data-section-id=\"1ls1u7z\" data-start=\"6436\" data-end=\"6460\">Agricultural machinery<\/li>\n<li data-section-id=\"16wih39\" data-start=\"6461\" data-end=\"6483\">Industrial equipment<\/li>\n<li data-section-id=\"1c6zwwd\" data-start=\"6484\" data-end=\"6507\">Structural assemblies<\/li>\n<li data-section-id=\"pq5ogs\" data-start=\"6508\" data-end=\"6530\">Manufacturing plants<\/li>\n<li data-section-id=\"1p0pfaz\" data-start=\"6531\" data-end=\"6554\">Mechanical assemblies<\/li>\n<li data-section-id=\"11pur2f\" data-start=\"6555\" data-end=\"6576\">General engineering<\/li>\n<li data-section-id=\"1nrcn5o\" data-start=\"6577\" data-end=\"6603\">Maintenance applications<\/li>\n<\/ul>\n<p data-start=\"6605\" data-end=\"6709\">Their hexagonal head makes them convenient for applications requiring controlled tightening and removal.<\/p>\n<hr data-start=\"6711\" data-end=\"6714\" \/>\n<h1 data-section-id=\"q6znlx\" data-start=\"6716\" data-end=\"6728\">Dimensions<\/h1>\n<p data-start=\"6730\" data-end=\"6813\">Dimensional conformity is one of the important requirements for Hexagon Head Bolts.<\/p>\n<p data-start=\"6815\" data-end=\"6890\">Depending on the applicable requirements, dimensional inspection can cover:<\/p>\n<ul data-start=\"6892\" data-end=\"7065\">\n<li data-section-id=\"1xk1xc9\" data-start=\"6892\" data-end=\"6910\">Nominal diameter<\/li>\n<li data-section-id=\"1reilxd\" data-start=\"6911\" data-end=\"6924\">Bolt length<\/li>\n<li data-section-id=\"j3rkhv\" data-start=\"6925\" data-end=\"6942\">Head dimensions<\/li>\n<li data-section-id=\"xjnttr\" data-start=\"6943\" data-end=\"6956\">Head height<\/li>\n<li data-section-id=\"1d6krb1\" data-start=\"6957\" data-end=\"6977\">Width across flats<\/li>\n<li data-section-id=\"nj7lga\" data-start=\"6978\" data-end=\"6993\">Thread length<\/li>\n<li data-section-id=\"1f6zig1\" data-start=\"6994\" data-end=\"7011\">Thread diameter<\/li>\n<li data-section-id=\"15uuc6l\" data-start=\"7012\" data-end=\"7040\">Other specified dimensions<\/li>\n<li data-section-id=\"wv2yjz\" data-start=\"7041\" data-end=\"7065\">Dimensional tolerances<\/li>\n<\/ul>\n<p data-start=\"7067\" data-end=\"7215\">The current BIS Product Manual identifies <strong data-start=\"7109\" data-end=\"7123\">Dimensions<\/strong> as a specific testing requirement under the standard.<\/p>\n<hr data-start=\"7217\" data-end=\"7220\" \/>\n<h1 data-section-id=\"1n9ejqc\" data-start=\"7222\" data-end=\"7243\">Thread Requirements<\/h1>\n<p data-start=\"7245\" data-end=\"7327\">The threaded portion must comply with the applicable requirements of the standard.<\/p>\n<p data-start=\"7329\" data-end=\"7367\">Thread-related inspection can include:<\/p>\n<ul data-start=\"7369\" data-end=\"7478\">\n<li data-section-id=\"1wwol0j\" data-start=\"7369\" data-end=\"7382\">Thread size<\/li>\n<li data-section-id=\"rq81pp\" data-start=\"7383\" data-end=\"7399\">Thread profile<\/li>\n<li data-section-id=\"y83fk\" data-start=\"7400\" data-end=\"7414\">Thread pitch<\/li>\n<li data-section-id=\"13sg0mn\" data-start=\"7415\" data-end=\"7433\">Thread tolerance<\/li>\n<li data-section-id=\"ntkjah\" data-start=\"7434\" data-end=\"7459\">Thread gauge inspection<\/li>\n<li data-section-id=\"8zdr5h\" data-start=\"7460\" data-end=\"7478\">Thread condition<\/li>\n<\/ul>\n<p data-start=\"7480\" data-end=\"7627\">BIS laboratory information identifies <strong data-start=\"7518\" data-end=\"7528\">Thread<\/strong> as one of the applicable testing areas for IS 1363 Part 1.<\/p>\n<hr data-start=\"7629\" data-end=\"7632\" \/>\n<h1 data-section-id=\"3h8jos\" data-start=\"7634\" data-end=\"7657\">Mechanical Properties<\/h1>\n<p data-start=\"7659\" data-end=\"7788\">Mechanical properties are important because Hexagon Head Bolts must withstand the loads experienced during fastening and service.<\/p>\n<p data-start=\"7790\" data-end=\"7828\">The applicable evaluation can include:<\/p>\n<ul data-start=\"7830\" data-end=\"7952\">\n<li data-section-id=\"r8mtb9\" data-start=\"7830\" data-end=\"7850\">Tensile properties<\/li>\n<li data-section-id=\"14ei53e\" data-start=\"7851\" data-end=\"7863\">Proof load<\/li>\n<li data-section-id=\"1rhmjlo\" data-start=\"7864\" data-end=\"7874\">Hardness<\/li>\n<li data-section-id=\"9exjoh\" data-start=\"7875\" data-end=\"7909\">Strength-related characteristics<\/li>\n<li data-section-id=\"vqufuu\" data-start=\"7910\" data-end=\"7952\">Other applicable mechanical requirements<\/li>\n<\/ul>\n<p data-start=\"7954\" data-end=\"8124\">The current BIS Product Manual identifies <strong data-start=\"7996\" data-end=\"8039\">4.6 \/ 4.8 \/ as declared by manufacturer<\/strong> as the property-class scope for the product.<\/p>\n<hr data-start=\"8126\" data-end=\"8129\" \/>\n<h1 data-section-id=\"1h75g00\" data-start=\"8131\" data-end=\"8150\">Surface Condition<\/h1>\n<p data-start=\"8152\" data-end=\"8233\">The surface condition of the bolt should comply with the applicable requirements.<\/p>\n<p data-start=\"8235\" data-end=\"8263\">The evaluation may consider:<\/p>\n<ul data-start=\"8265\" data-end=\"8370\">\n<li data-section-id=\"15mzun7\" data-start=\"8265\" data-end=\"8285\">Surface appearance<\/li>\n<li data-section-id=\"1nivxwu\" data-start=\"8286\" data-end=\"8295\">Defects<\/li>\n<li data-section-id=\"gfvd5k\" data-start=\"8296\" data-end=\"8322\">Corrosion-related issues<\/li>\n<li data-section-id=\"1sy1q1a\" data-start=\"8323\" data-end=\"8344\">Manufacturing marks<\/li>\n<li data-section-id=\"1g88xqd\" data-start=\"8345\" data-end=\"8370\">Surface discontinuities<\/li>\n<\/ul>\n<p data-start=\"8372\" data-end=\"8505\">BIS laboratory information includes <strong data-start=\"8408\" data-end=\"8429\">Surface Condition<\/strong> among the applicable testing areas.<\/p>\n<hr data-start=\"8507\" data-end=\"8510\" \/>\n<h1 data-section-id=\"10rt22c\" data-start=\"8512\" data-end=\"8531\">Surface Integrity<\/h1>\n<p data-start=\"8533\" data-end=\"8658\">Surface integrity is particularly important for fasteners because cracks and other defects can negatively affect performance.<\/p>\n<p data-start=\"8660\" data-end=\"8705\">Possible defects that need attention include:<\/p>\n<ul data-start=\"8707\" data-end=\"8796\">\n<li data-section-id=\"1v9yjkz\" data-start=\"8707\" data-end=\"8715\">Cracks<\/li>\n<li data-section-id=\"178os2p\" data-start=\"8716\" data-end=\"8723\">Seams<\/li>\n<li data-section-id=\"1j3uhhi\" data-start=\"8724\" data-end=\"8730\">Laps<\/li>\n<li data-section-id=\"170jnyy\" data-start=\"8731\" data-end=\"8738\">Folds<\/li>\n<li data-section-id=\"1d1mj1y\" data-start=\"8739\" data-end=\"8751\">Tool marks<\/li>\n<li data-section-id=\"qsx768\" data-start=\"8752\" data-end=\"8796\">Other unacceptable surface discontinuities<\/li>\n<\/ul>\n<p data-start=\"8798\" data-end=\"8926\">The BIS testing information identifies <strong data-start=\"8837\" data-end=\"8858\">Surface Integrity<\/strong> as a separate testing area.<\/p>\n<hr data-start=\"8928\" data-end=\"8931\" \/>\n<h1 data-section-id=\"ilew58\" data-start=\"8933\" data-end=\"8945\">Tolerances<\/h1>\n<p data-start=\"8947\" data-end=\"9046\">Manufacturing tolerances must be maintained within the applicable limits specified by the standard.<\/p>\n<p data-start=\"9048\" data-end=\"9065\">This can involve:<\/p>\n<ul data-start=\"9067\" data-end=\"9193\">\n<li data-section-id=\"wv2yjz\" data-start=\"9067\" data-end=\"9091\">Dimensional tolerances<\/li>\n<li data-section-id=\"yinla4\" data-start=\"9092\" data-end=\"9111\">Thread tolerances<\/li>\n<li data-section-id=\"l608ze\" data-start=\"9112\" data-end=\"9129\">Head tolerances<\/li>\n<li data-section-id=\"128yg5q\" data-start=\"9130\" data-end=\"9149\">Length tolerances<\/li>\n<li data-section-id=\"1i880d7\" data-start=\"9150\" data-end=\"9193\">Other applicable manufacturing tolerances<\/li>\n<\/ul>\n<p data-start=\"9195\" data-end=\"9327\">BIS laboratory information specifically lists <strong data-start=\"9241\" data-end=\"9255\">Tolerances<\/strong> among the testing requirements.<\/p>\n<hr data-start=\"9329\" data-end=\"9332\" \/>\n<h1 data-section-id=\"9oqsy\" data-start=\"9334\" data-end=\"9362\">Surface Finish and Coating<\/h1>\n<p data-start=\"9364\" data-end=\"9454\">Hexagon Head Bolts may be supplied with different surface finishes or protective coatings.<\/p>\n<p data-start=\"9456\" data-end=\"9513\">Depending on the product specification, this can include:<\/p>\n<ul data-start=\"9515\" data-end=\"9610\">\n<li data-section-id=\"7yd7pe\" data-start=\"9515\" data-end=\"9542\">Electrolytic zinc coating<\/li>\n<li data-section-id=\"1au6q7p\" data-start=\"9543\" data-end=\"9581\">Other applicable protective finishes<\/li>\n<li data-section-id=\"1pjotcd\" data-start=\"9582\" data-end=\"9610\">Uncoated surface condition<\/li>\n<\/ul>\n<p data-start=\"9612\" data-end=\"9716\">The applicable finish should be clearly identified in the product specification and certification scope.<\/p>\n<hr data-start=\"9718\" data-end=\"9721\" \/>\n<h1 data-section-id=\"9dutwa\" data-start=\"9723\" data-end=\"9738\">Raw Materials<\/h1>\n<p data-start=\"9740\" data-end=\"9854\">Suitable steel raw material should be selected to achieve the required dimensional and mechanical characteristics.<\/p>\n<p data-start=\"9856\" data-end=\"9906\">Manufacturers should maintain proper control over:<\/p>\n<ul data-start=\"9908\" data-end=\"10045\">\n<li data-section-id=\"1z01t38\" data-start=\"9908\" data-end=\"9937\">Raw-material specifications<\/li>\n<li data-section-id=\"zib2zp\" data-start=\"9938\" data-end=\"9961\">Material certificates<\/li>\n<li data-section-id=\"17zuqtc\" data-start=\"9962\" data-end=\"9976\">Heat numbers<\/li>\n<li data-section-id=\"pi9avy\" data-start=\"9977\" data-end=\"9999\">Batch identification<\/li>\n<li data-section-id=\"m8jnps\" data-start=\"10000\" data-end=\"10021\">Incoming inspection<\/li>\n<li data-section-id=\"mgc2ww\" data-start=\"10022\" data-end=\"10045\">Material traceability<\/li>\n<\/ul>\n<p data-start=\"10047\" data-end=\"10178\">Raw-material requirements should be verified against the latest applicable standard and the manufacturer&#8217;s declared property class.<\/p>\n<hr data-start=\"10180\" data-end=\"10183\" \/>\n<h1 data-section-id=\"mkkw31\" data-start=\"10185\" data-end=\"10208\">Manufacturing Process<\/h1>\n<p data-start=\"10210\" data-end=\"10272\">A typical Hexagon Head Bolt manufacturing process can include:<\/p>\n<h3 data-section-id=\"5l2bhl\" data-start=\"10274\" data-end=\"10300\">Raw Material Selection<\/h3>\n<p data-start=\"10302\" data-end=\"10338\">Suitable steel wire\/rod is selected.<\/p>\n<h3 data-section-id=\"11ewydy\" data-start=\"10340\" data-end=\"10360\">Wire Preparation<\/h3>\n<p data-start=\"10362\" data-end=\"10430\">The raw material is prepared according to the manufacturing process.<\/p>\n<h3 data-section-id=\"gdyiy6\" data-start=\"10432\" data-end=\"10443\">Heading<\/h3>\n<p data-start=\"10445\" data-end=\"10479\">The hexagonal bolt head is formed.<\/p>\n<h3 data-section-id=\"1hbv283\" data-start=\"10481\" data-end=\"10501\">Thread Formation<\/h3>\n<p data-start=\"10503\" data-end=\"10582\">Threads are produced through rolling or another suitable manufacturing process.<\/p>\n<h3 data-section-id=\"19ra7lm\" data-start=\"10584\" data-end=\"10602\">Heat Treatment<\/h3>\n<p data-start=\"10604\" data-end=\"10698\">Where applicable, heat treatment is carried out to achieve the required mechanical properties.<\/p>\n<h3 data-section-id=\"f063uf\" data-start=\"10700\" data-end=\"10721\">Surface Treatment<\/h3>\n<p data-start=\"10723\" data-end=\"10775\">The bolt may undergo cleaning, coating or finishing.<\/p>\n<h3 data-section-id=\"j96rjs\" data-start=\"10777\" data-end=\"10791\">Inspection<\/h3>\n<p data-start=\"10793\" data-end=\"10859\">Dimensions, threads, surface condition and appearance are checked.<\/p>\n<h3 data-section-id=\"zp2zu8\" data-start=\"10861\" data-end=\"10872\">Testing<\/h3>\n<p data-start=\"10874\" data-end=\"10940\">Representative samples are tested against applicable requirements.<\/p>\n<h3 data-section-id=\"1btpd0f\" data-start=\"10942\" data-end=\"10953\">Packing<\/h3>\n<p data-start=\"10955\" data-end=\"11014\">The finished bolts are identified and packed appropriately.<\/p>\n<hr data-start=\"11016\" data-end=\"11019\" \/>\n<h1 data-section-id=\"1dr8hy4\" data-start=\"11021\" data-end=\"11043\">Testing Requirements<\/h1>\n<p data-start=\"11045\" data-end=\"11078\">Testing and evaluation can cover:<\/p>\n<ul data-start=\"11080\" data-end=\"11255\">\n<li data-section-id=\"zy1zez\" data-start=\"11080\" data-end=\"11092\">Dimensions<\/li>\n<li data-section-id=\"hmln76\" data-start=\"11093\" data-end=\"11115\">General requirements<\/li>\n<li data-section-id=\"5mooh2\" data-start=\"11116\" data-end=\"11124\">Thread<\/li>\n<li data-section-id=\"14djerm\" data-start=\"11125\" data-end=\"11148\">Mechanical properties<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"11149\" data-end=\"11161\">Tolerances<\/li>\n<li data-section-id=\"a05w8e\" data-start=\"11162\" data-end=\"11181\">Surface condition<\/li>\n<li data-section-id=\"uzpaze\" data-start=\"11182\" data-end=\"11201\">Surface integrity<\/li>\n<li data-section-id=\"1o565d6\" data-start=\"11202\" data-end=\"11217\">Acceptability<\/li>\n<li data-section-id=\"17r594s\" data-start=\"11218\" data-end=\"11241\">Marking and labelling<\/li>\n<li data-section-id=\"1rta8av\" data-start=\"11242\" data-end=\"11255\">Designation<\/li>\n<\/ul>\n<p data-start=\"11257\" data-end=\"11396\">Current BIS LIMS information lists these testing areas for the active IS 1363 Part 1 product entry.<\/p>\n<hr data-start=\"11398\" data-end=\"11401\" \/>\n<h1 data-section-id=\"li0iq3\" data-start=\"11403\" data-end=\"11427\">BIS Laboratory Testing<\/h1>\n<p data-start=\"11429\" data-end=\"11524\">BIS LIMS currently lists laboratories providing testing facilities for <strong data-start=\"11500\" data-end=\"11523\">IS 1363 Part 1:2023<\/strong>.<\/p>\n<p data-start=\"11526\" data-end=\"11773\">For example, one current listing shows a testing charge of <strong data-start=\"11585\" data-end=\"11612\">\u20b914,000 excluding taxes<\/strong> for a specified complete scope. Another laboratory listing shows <strong data-start=\"11678\" data-end=\"11705\">\u20b915,000 excluding taxes<\/strong> for testing up to M33 size.<\/p>\n<p data-start=\"11775\" data-end=\"11824\">Individual testing charges may vary depending on:<\/p>\n<ul data-start=\"11826\" data-end=\"11932\">\n<li data-section-id=\"nyga17\" data-start=\"11826\" data-end=\"11838\">Laboratory<\/li>\n<li data-section-id=\"1stk9wm\" data-start=\"11839\" data-end=\"11853\">Product size<\/li>\n<li data-section-id=\"1ymix4k\" data-start=\"11854\" data-end=\"11869\">Testing scope<\/li>\n<li data-section-id=\"18o2w9t\" data-start=\"11870\" data-end=\"11886\">Property class<\/li>\n<li data-section-id=\"a05w8e\" data-start=\"11887\" data-end=\"11906\">Surface condition<\/li>\n<li data-section-id=\"uda59l\" data-start=\"11907\" data-end=\"11932\">Applicable requirements<\/li>\n<\/ul>\n<p data-start=\"11934\" data-end=\"12042\">Therefore, the final testing cost should be confirmed for the exact product scope before submitting samples.<\/p>\n<hr data-start=\"12044\" data-end=\"12047\" \/>\n<h1 data-section-id=\"1vg11y7\" data-start=\"12049\" data-end=\"12069\">Sample Requirement<\/h1>\n<p data-start=\"12071\" data-end=\"12112\">The current BIS Product Manual specifies:<\/p>\n<p data-start=\"12114\" data-end=\"12138\"><strong data-start=\"12114\" data-end=\"12138\">Sample Size: 6 Bolts<\/strong><\/p>\n<p data-start=\"12140\" data-end=\"12206\">for IS 1363 (Part 1):2023.<\/p>\n<p data-start=\"12208\" data-end=\"12345\">The actual sampling procedure should always be confirmed against the latest BIS Product Manual and applicable certification instructions.<\/p>\n<hr data-start=\"12347\" data-end=\"12350\" \/>\n<h1 data-section-id=\"u9b84y\" data-start=\"12352\" data-end=\"12370\">Product Grouping<\/h1>\n<p data-start=\"12372\" data-end=\"12475\">Product grouping is an important part of BIS certification because a manufacturer may produce multiple:<\/p>\n<ul data-start=\"12477\" data-end=\"12535\">\n<li data-section-id=\"178ffjy\" data-start=\"12477\" data-end=\"12484\">Sizes<\/li>\n<li data-section-id=\"1nakryv\" data-start=\"12485\" data-end=\"12503\">Property classes<\/li>\n<li data-section-id=\"1a0ybtp\" data-start=\"12504\" data-end=\"12524\">Surface conditions<\/li>\n<li data-section-id=\"1eo0vyl\" data-start=\"12525\" data-end=\"12535\">Finishes<\/li>\n<\/ul>\n<p data-start=\"12537\" data-end=\"12659\">The current Product Manual provides product grouping guidelines under <strong data-start=\"12607\" data-end=\"12618\">Annex A<\/strong>.<\/p>\n<p data-start=\"12661\" data-end=\"12774\">Proper grouping can help determine which representative samples need to be tested for a particular licence scope.<\/p>\n<p data-start=\"12776\" data-end=\"12935\">Manufacturers should not assume that testing one size automatically covers every size and variant. The applicable BIS grouping requirements should be followed.<\/p>\n<hr data-start=\"12937\" data-end=\"12940\" \/>\n<h1 data-section-id=\"2uzze8\" data-start=\"12942\" data-end=\"12972\">Who Needs BIS Certification?<\/h1>\n<p data-start=\"12974\" data-end=\"13108\">The certification requirements may apply to manufacturers producing Hexagon Head Bolts covered by the applicable regulatory framework.<\/p>\n<p data-start=\"13110\" data-end=\"13127\">This can include:<\/p>\n<ul data-start=\"13129\" data-end=\"13418\">\n<li data-section-id=\"8n8vps\" data-start=\"13129\" data-end=\"13153\">Fastener manufacturers<\/li>\n<li data-section-id=\"ugqgl5\" data-start=\"13154\" data-end=\"13174\">Bolt manufacturers<\/li>\n<li data-section-id=\"1u81vw7\" data-start=\"13175\" data-end=\"13210\">Industrial fastener manufacturers<\/li>\n<li data-section-id=\"1m9fgjw\" data-start=\"13211\" data-end=\"13247\">Automobile component manufacturers<\/li>\n<li data-section-id=\"179bi4a\" data-start=\"13248\" data-end=\"13285\">Engineering component manufacturers<\/li>\n<li data-section-id=\"1tnqu88\" data-start=\"13286\" data-end=\"13301\">OEM suppliers<\/li>\n<li data-section-id=\"kib2oi\" data-start=\"13302\" data-end=\"13326\">Hardware manufacturers<\/li>\n<li data-section-id=\"12nxk5p\" data-start=\"13327\" data-end=\"13362\">Machinery component manufacturers<\/li>\n<li data-section-id=\"1ci7zxu\" data-start=\"13363\" data-end=\"13418\">Manufacturers supplying bolts to industrial customers<\/li>\n<\/ul>\n<p data-start=\"13420\" data-end=\"13519\">Importers and other businesses should separately verify their obligations under the applicable QCO.<\/p>\n<hr data-start=\"13521\" data-end=\"13524\" \/>\n<h1 data-section-id=\"1jwi5nr\" data-start=\"13526\" data-end=\"13552\">Eligibility Requirements<\/h1>\n<p data-start=\"13554\" data-end=\"13600\">A manufacturer should generally have suitable:<\/p>\n<ul data-start=\"13602\" data-end=\"13993\">\n<li data-section-id=\"k244lq\" data-start=\"13602\" data-end=\"13626\">Manufacturing premises<\/li>\n<li data-section-id=\"pqp7u6\" data-start=\"13627\" data-end=\"13646\">Heading machinery<\/li>\n<li data-section-id=\"vwmvoo\" data-start=\"13647\" data-end=\"13668\">Threading machinery<\/li>\n<li data-section-id=\"10rvd8a\" data-start=\"13669\" data-end=\"13713\">Heat-treatment facilities where applicable<\/li>\n<li data-section-id=\"1nj2rav\" data-start=\"13714\" data-end=\"13761\">Surface-treatment facilities where applicable<\/li>\n<li data-section-id=\"l7womr\" data-start=\"13762\" data-end=\"13785\">Measuring instruments<\/li>\n<li data-section-id=\"8kswp\" data-start=\"13786\" data-end=\"13840\">Testing facilities or permitted testing arrangements<\/li>\n<li data-section-id=\"pwhw22\" data-start=\"13841\" data-end=\"13865\">Quality-control system<\/li>\n<li data-section-id=\"kpeh8n\" data-start=\"13866\" data-end=\"13886\">Calibration system<\/li>\n<li data-section-id=\"hzbrql\" data-start=\"13887\" data-end=\"13909\">Raw-material control<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"13910\" data-end=\"13930\">Production records<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"13931\" data-end=\"13951\">Inspection records<\/li>\n<li data-section-id=\"rkxeqa\" data-start=\"13952\" data-end=\"13972\">Storage facilities<\/li>\n<li data-section-id=\"46vb5e\" data-start=\"13973\" data-end=\"13993\">Packing facilities<\/li>\n<\/ul>\n<hr data-start=\"13995\" data-end=\"13998\" \/>\n<h1 data-section-id=\"14s1v1v\" data-start=\"14000\" data-end=\"14020\">Documents Required<\/h1>\n<p data-start=\"14022\" data-end=\"14092\">Documents commonly required for the certification process can include:<\/p>\n<ul data-start=\"14094\" data-end=\"14617\">\n<li data-section-id=\"laj0jm\" data-start=\"14094\" data-end=\"14126\">Company registration documents<\/li>\n<li data-section-id=\"a8o83y\" data-start=\"14127\" data-end=\"14150\">Factory address proof<\/li>\n<li data-section-id=\"17ibqzq\" data-start=\"14151\" data-end=\"14167\">Factory layout<\/li>\n<li data-section-id=\"18vosvl\" data-start=\"14168\" data-end=\"14196\">Manufacturing process flow<\/li>\n<li data-section-id=\"ef1hg\" data-start=\"14197\" data-end=\"14213\">Machinery list<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"14214\" data-end=\"14232\">Product drawings<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"14233\" data-end=\"14257\">Product specifications<\/li>\n<li data-section-id=\"1t9reql\" data-start=\"14258\" data-end=\"14278\">Size-range details<\/li>\n<li data-section-id=\"i6943y\" data-start=\"14279\" data-end=\"14303\">Property-class details<\/li>\n<li data-section-id=\"1z01t38\" data-start=\"14304\" data-end=\"14333\">Raw-material specifications<\/li>\n<li data-section-id=\"1xxybf7\" data-start=\"14334\" data-end=\"14362\">Material test certificates<\/li>\n<li data-section-id=\"1fo8gvq\" data-start=\"14363\" data-end=\"14387\">Testing equipment list<\/li>\n<li data-section-id=\"1ymt51g\" data-start=\"14388\" data-end=\"14414\">Calibration certificates<\/li>\n<li data-section-id=\"16dybms\" data-start=\"14415\" data-end=\"14438\">Internal test reports<\/li>\n<li data-section-id=\"1vbfc8h\" data-start=\"14439\" data-end=\"14464\">Quality-control records<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"14465\" data-end=\"14485\">Inspection records<\/li>\n<li data-section-id=\"684x8w\" data-start=\"14486\" data-end=\"14507\">Product photographs<\/li>\n<li data-section-id=\"74k6c5\" data-start=\"14508\" data-end=\"14527\">Packaging details<\/li>\n<li data-section-id=\"1hcgcf\" data-start=\"14528\" data-end=\"14545\">Marking details<\/li>\n<li data-section-id=\"75qyjr\" data-start=\"14546\" data-end=\"14584\">Trademark documents where applicable<\/li>\n<li data-section-id=\"1gg3gcx\" data-start=\"14585\" data-end=\"14617\">Authorized signatory documents<\/li>\n<\/ul>\n<p data-start=\"14619\" data-end=\"14686\">The exact document list depends on the applicant and product scope.<\/p>\n<hr data-start=\"14688\" data-end=\"14691\" \/>\n<h1 data-section-id=\"ayo1bh\" data-start=\"14693\" data-end=\"14720\">BIS Certification Process<\/h1>\n<h2 data-section-id=\"f8b1ob\" data-start=\"14722\" data-end=\"14750\">1. Product Identification<\/h2>\n<p data-start=\"14752\" data-end=\"14803\">The product and applicable standard are identified.<\/p>\n<h2 data-section-id=\"1m0fddk\" data-start=\"14805\" data-end=\"14826\">2. Standard Review<\/h2>\n<p data-start=\"14828\" data-end=\"14872\">Requirements of IS 1363 Part 1 are reviewed.<\/p>\n<h2 data-section-id=\"1l59o4a\" data-start=\"14874\" data-end=\"14898\">3. Factory Assessment<\/h2>\n<p data-start=\"14900\" data-end=\"14972\">Manufacturing facilities and quality-control arrangements are evaluated.<\/p>\n<h2 data-section-id=\"p3p9nv\" data-start=\"14974\" data-end=\"14996\">4. Product Grouping<\/h2>\n<p data-start=\"14998\" data-end=\"15056\">Applicable size and property-class grouping is determined.<\/p>\n<h2 data-section-id=\"1gu3t2k\" data-start=\"15058\" data-end=\"15077\">5. Documentation<\/h2>\n<p data-start=\"15079\" data-end=\"15122\">Technical and legal documents are prepared.<\/p>\n<h2 data-section-id=\"c7i3gi\" data-start=\"15124\" data-end=\"15148\">6. Sample Preparation<\/h2>\n<p data-start=\"15150\" data-end=\"15186\">Representative samples are prepared.<\/p>\n<h2 data-section-id=\"1p3gw3t\" data-start=\"15188\" data-end=\"15212\">7. Laboratory Testing<\/h2>\n<p data-start=\"15214\" data-end=\"15265\">Samples are tested against applicable requirements.<\/p>\n<h2 data-section-id=\"13vsh01\" data-start=\"15267\" data-end=\"15288\">8. BIS Application<\/h2>\n<p data-start=\"15290\" data-end=\"15366\">The application is submitted through the applicable BIS certification route.<\/p>\n<h2 data-section-id=\"mwthh3\" data-start=\"15368\" data-end=\"15386\">9. BIS Scrutiny<\/h2>\n<p data-start=\"15388\" data-end=\"15430\">BIS reviews the application and documents.<\/p>\n<h2 data-section-id=\"6i3jz4\" data-start=\"15432\" data-end=\"15457\">10. Factory Inspection<\/h2>\n<p data-start=\"15459\" data-end=\"15510\">The manufacturing facility is assessed as required.<\/p>\n<h2 data-section-id=\"axqbb9\" data-start=\"15512\" data-end=\"15541\">11. Test Report Evaluation<\/h2>\n<p data-start=\"15543\" data-end=\"15572\">Testing results are reviewed.<\/p>\n<h2 data-section-id=\"16ykyqj\" data-start=\"15574\" data-end=\"15600\">12. Observation Closure<\/h2>\n<p data-start=\"15602\" data-end=\"15653\">Any observations or non-conformities are addressed.<\/p>\n<h2 data-section-id=\"2iy2zw\" data-start=\"15655\" data-end=\"15675\">13. Licence Grant<\/h2>\n<p data-start=\"15677\" data-end=\"15763\">The BIS licence is granted after successful completion of the applicable requirements.<\/p>\n<h2 data-section-id=\"caj334\" data-start=\"15765\" data-end=\"15785\">14. Standard Mark<\/h2>\n<p data-start=\"15787\" data-end=\"15849\">The Standard Mark is used according to the licence conditions.<\/p>\n<hr data-start=\"15851\" data-end=\"15854\" \/>\n<h1 data-section-id=\"1mfuv2k\" data-start=\"15856\" data-end=\"15876\">Factory Inspection<\/h1>\n<p data-start=\"15878\" data-end=\"15937\">During the factory assessment, important areas can include:<\/p>\n<h3 data-section-id=\"11jvbvt\" data-start=\"15939\" data-end=\"15955\">Raw Material<\/h3>\n<p data-start=\"15957\" data-end=\"16014\">Verification of material specifications and traceability.<\/p>\n<h3 data-section-id=\"ihy9m0\" data-start=\"16016\" data-end=\"16043\">Manufacturing Machinery<\/h3>\n<p data-start=\"16045\" data-end=\"16119\">Inspection of heading, threading, heat treatment and finishing facilities.<\/p>\n<h3 data-section-id=\"5sl7zi\" data-start=\"16121\" data-end=\"16143\">Production Process<\/h3>\n<p data-start=\"16145\" data-end=\"16178\">Review of manufacturing controls.<\/p>\n<h3 data-section-id=\"1bp206y\" data-start=\"16180\" data-end=\"16201\">Testing Equipment<\/h3>\n<p data-start=\"16203\" data-end=\"16260\">Verification of relevant measuring and testing equipment.<\/p>\n<h3 data-section-id=\"wzkpnw\" data-start=\"16262\" data-end=\"16277\">Calibration<\/h3>\n<p data-start=\"16279\" data-end=\"16309\">Review of calibration records.<\/p>\n<h3 data-section-id=\"gr3tzg\" data-start=\"16311\" data-end=\"16330\">Quality Control<\/h3>\n<p data-start=\"16332\" data-end=\"16407\">Inspection of incoming, in-process and finished-product inspection systems.<\/p>\n<h3 data-section-id=\"1oz01yd\" data-start=\"16409\" data-end=\"16425\">Traceability<\/h3>\n<p data-start=\"16427\" data-end=\"16461\">Checking batch\/lot identification.<\/p>\n<h3 data-section-id=\"1l1laoj\" data-start=\"16463\" data-end=\"16474\">Marking<\/h3>\n<p data-start=\"16476\" data-end=\"16519\">Verification of applicable product marking.<\/p>\n<h3 data-section-id=\"1btpd0f\" data-start=\"16521\" data-end=\"16532\">Packing<\/h3>\n<p data-start=\"16534\" data-end=\"16581\">Inspection of storage and packing arrangements.<\/p>\n<hr data-start=\"16583\" data-end=\"16586\" \/>\n<h1 data-section-id=\"100aerd\" data-start=\"16588\" data-end=\"16629\">Common Reasons for Certification Delays<\/h1>\n<p data-start=\"16631\" data-end=\"16674\">Manufacturers may experience delays due to:<\/p>\n<ul data-start=\"16676\" data-end=\"17119\">\n<li data-section-id=\"h0xmh6\" data-start=\"16676\" data-end=\"16706\">Incorrect standard selection<\/li>\n<li data-section-id=\"1itxzfo\" data-start=\"16707\" data-end=\"16735\">Using an outdated standard<\/li>\n<li data-section-id=\"1lyyp0l\" data-start=\"16736\" data-end=\"16764\">Incorrect product grouping<\/li>\n<li data-section-id=\"khr81q\" data-start=\"16765\" data-end=\"16794\">Incomplete product drawings<\/li>\n<li data-section-id=\"17yomeq\" data-start=\"16795\" data-end=\"16817\">Incorrect dimensions<\/li>\n<li data-section-id=\"t4hz78\" data-start=\"16818\" data-end=\"16841\">Thread non-conformity<\/li>\n<li data-section-id=\"1j8b6id\" data-start=\"16842\" data-end=\"16867\">Mechanical test failure<\/li>\n<li data-section-id=\"1pcnrsr\" data-start=\"16868\" data-end=\"16885\">Surface defects<\/li>\n<li data-section-id=\"1cscbei\" data-start=\"16886\" data-end=\"16911\">Improper heat treatment<\/li>\n<li data-section-id=\"1la5v9l\" data-start=\"16912\" data-end=\"16930\">Coating problems<\/li>\n<li data-section-id=\"hedlgh\" data-start=\"16931\" data-end=\"16962\">Missing material certificates<\/li>\n<li data-section-id=\"jaist4\" data-start=\"16963\" data-end=\"16992\">Missing calibration records<\/li>\n<li data-section-id=\"1ry1on3\" data-start=\"16993\" data-end=\"17029\">Incomplete quality-control records<\/li>\n<li data-section-id=\"1q7qwro\" data-start=\"17030\" data-end=\"17049\">Incorrect marking<\/li>\n<li data-section-id=\"1pruwyv\" data-start=\"17050\" data-end=\"17084\">Factory not ready for inspection<\/li>\n<li data-section-id=\"o0rwlc\" data-start=\"17085\" data-end=\"17119\">Incomplete application documents<\/li>\n<\/ul>\n<p data-start=\"17121\" data-end=\"17189\">Proper preparation before application can reduce unnecessary delays.<\/p>\n<hr data-start=\"17191\" data-end=\"17194\" \/>\n<h1 data-section-id=\"1jye7rh\" data-start=\"17196\" data-end=\"17220\">BIS Certification Cost<\/h1>\n<p data-start=\"17222\" data-end=\"17248\">The total cost depends on:<\/p>\n<ul data-start=\"17250\" data-end=\"17496\">\n<li data-section-id=\"wndo83\" data-start=\"17250\" data-end=\"17275\">BIS application charges<\/li>\n<li data-section-id=\"khts3h\" data-start=\"17276\" data-end=\"17296\">Laboratory testing<\/li>\n<li data-section-id=\"1stk9wm\" data-start=\"17297\" data-end=\"17311\">Product size<\/li>\n<li data-section-id=\"1rptq06\" data-start=\"17312\" data-end=\"17332\">Number of variants<\/li>\n<li data-section-id=\"18o2w9t\" data-start=\"17333\" data-end=\"17349\">Property class<\/li>\n<li data-section-id=\"a05w8e\" data-start=\"17350\" data-end=\"17369\">Surface condition<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"17370\" data-end=\"17388\">Product grouping<\/li>\n<li data-section-id=\"1ci9n36\" data-start=\"17389\" data-end=\"17409\">Factory inspection<\/li>\n<li data-section-id=\"3z5tc\" data-start=\"17410\" data-end=\"17433\">Sample transportation<\/li>\n<li data-section-id=\"w80kxv\" data-start=\"17434\" data-end=\"17458\">Retesting, if required<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"17459\" data-end=\"17474\">Documentation<\/li>\n<li data-section-id=\"1q8f3t4\" data-start=\"17475\" data-end=\"17496\">Consultancy charges<\/li>\n<\/ul>\n<p data-start=\"17498\" data-end=\"17769\">Current BIS LIMS listings show different testing costs depending on laboratory and scope. For example, current listings include <strong data-start=\"17626\" data-end=\"17637\">\u20b914,000<\/strong> for one complete listed scope and <strong data-start=\"17672\" data-end=\"17683\">\u20b915,000<\/strong> for another scope up to M33, excluding taxes.<\/p>\n<p data-start=\"17771\" data-end=\"17890\">The actual certification cost should therefore be calculated after reviewing the manufacturer&#8217;s complete product range.<\/p>\n<hr data-start=\"17892\" data-end=\"17895\" \/>\n<h1 data-section-id=\"1a3o6ed\" data-start=\"17897\" data-end=\"17921\">Certification Timeline<\/h1>\n<p data-start=\"17923\" data-end=\"17952\">The time required depends on:<\/p>\n<ul data-start=\"17954\" data-end=\"18131\">\n<li data-section-id=\"r60riv\" data-start=\"17954\" data-end=\"17974\">Document readiness<\/li>\n<li data-section-id=\"1213b4c\" data-start=\"17975\" data-end=\"17994\">Factory readiness<\/li>\n<li data-section-id=\"xjlpof\" data-start=\"17995\" data-end=\"18016\">Sample availability<\/li>\n<li data-section-id=\"m9rre6\" data-start=\"18017\" data-end=\"18038\">Laboratory schedule<\/li>\n<li data-section-id=\"19quzku\" data-start=\"18039\" data-end=\"18048\">Testing<\/li>\n<li data-section-id=\"u5eurx\" data-start=\"18049\" data-end=\"18063\">BIS scrutiny<\/li>\n<li data-section-id=\"1ci9n36\" data-start=\"18064\" data-end=\"18084\">Factory inspection<\/li>\n<li data-section-id=\"1g5zxie\" data-start=\"18085\" data-end=\"18109\">Test report evaluation<\/li>\n<li data-section-id=\"2xyyqj\" data-start=\"18110\" data-end=\"18131\">Observation closure<\/li>\n<\/ul>\n<p data-start=\"18133\" data-end=\"18224\">A product-specific timeline can be estimated after reviewing the factory and product scope.<\/p>\n<hr data-start=\"18226\" data-end=\"18229\" \/>\n<h1 data-section-id=\"wv2e8b\" data-start=\"18231\" data-end=\"18262\">Benefits of BIS Certification<\/h1>\n<h3 data-section-id=\"15cgiwz\" data-start=\"18264\" data-end=\"18289\">Regulatory Compliance<\/h3>\n<p data-start=\"18291\" data-end=\"18380\">Helps manufacturers meet applicable requirements under the relevant regulatory framework.<\/p>\n<h3 data-section-id=\"1s6jna8\" data-start=\"18382\" data-end=\"18401\">Product Quality<\/h3>\n<p data-start=\"18403\" data-end=\"18454\">Encourages consistent manufacturing and inspection.<\/p>\n<h3 data-section-id=\"k08kti\" data-start=\"18456\" data-end=\"18479\">Customer Confidence<\/h3>\n<p data-start=\"18481\" data-end=\"18554\">The BIS Standard Mark provides additional assurance regarding conformity.<\/p>\n<h3 data-section-id=\"s62ca3\" data-start=\"18556\" data-end=\"18577\">Market Acceptance<\/h3>\n<p data-start=\"18579\" data-end=\"18652\">Supports supply of certified products where BIS compliance is applicable.<\/p>\n<h3 data-section-id=\"1pnrp5h\" data-start=\"18654\" data-end=\"18677\">Better Traceability<\/h3>\n<p data-start=\"18679\" data-end=\"18749\">Quality-control documentation improves product and batch traceability.<\/p>\n<h3 data-section-id=\"517a1m\" data-start=\"18751\" data-end=\"18775\">Business Credibility<\/h3>\n<p data-start=\"18777\" data-end=\"18863\">BIS certification can strengthen confidence among industrial and institutional buyers.<\/p>\n<hr data-start=\"18865\" data-end=\"18868\" \/>\n<h1 data-section-id=\"18jhjpw\" data-start=\"18870\" data-end=\"18900\">Why Choose Qualitance India?<\/h1>\n<p data-start=\"18902\" data-end=\"19039\"><strong data-start=\"18902\" data-end=\"18922\">Qualitance India<\/strong> provides BIS certification consultancy services for manufacturers dealing with products covered by Indian Standards.<\/p>\n<p data-start=\"19041\" data-end=\"19121\">For <strong data-start=\"19045\" data-end=\"19096\">Hexagon Head Bolts as per IS 1363 (Part 1):2023<\/strong>, assistance can include:<\/p>\n<ul data-start=\"19123\" data-end=\"19511\">\n<li data-section-id=\"1mfdgr4\" data-start=\"19123\" data-end=\"19157\">Product applicability assessment<\/li>\n<li data-section-id=\"pkfmba\" data-start=\"19158\" data-end=\"19187\">Standard requirement review<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"19188\" data-end=\"19206\">Product grouping<\/li>\n<li data-section-id=\"1mqngnd\" data-start=\"19207\" data-end=\"19230\">Size-range assessment<\/li>\n<li data-section-id=\"oxstve\" data-start=\"19231\" data-end=\"19258\">Property-class assessment<\/li>\n<li data-section-id=\"16jeez9\" data-start=\"19259\" data-end=\"19282\">Documentation support<\/li>\n<li data-section-id=\"1kzgx2c\" data-start=\"19283\" data-end=\"19308\">Laboratory coordination<\/li>\n<li data-section-id=\"1vcb8rl\" data-start=\"19309\" data-end=\"19338\">Sample preparation guidance<\/li>\n<li data-section-id=\"hive5h\" data-start=\"19339\" data-end=\"19364\">BIS application support<\/li>\n<li data-section-id=\"sy9ixn\" data-start=\"19365\" data-end=\"19397\">Factory inspection preparation<\/li>\n<li data-section-id=\"1bxrev1\" data-start=\"19398\" data-end=\"19429\">Quality-control documentation<\/li>\n<li data-section-id=\"7nbtgf\" data-start=\"19430\" data-end=\"19456\">Test report coordination<\/li>\n<li data-section-id=\"1dssdod\" data-start=\"19457\" data-end=\"19489\">Observation closure assistance<\/li>\n<li data-section-id=\"1imghg4\" data-start=\"19490\" data-end=\"19511\">BIS licence support<\/li>\n<\/ul>\n<p data-start=\"19513\" data-end=\"19533\"><strong data-start=\"19513\" data-end=\"19533\">Qualitance India<\/strong><\/p>\n<p data-start=\"19535\" data-end=\"19664\"><strong data-start=\"19535\" data-end=\"19545\">Phone:<\/strong> +91-9310-615-170<br data-start=\"19562\" data-end=\"19565\" \/><strong data-start=\"19565\" data-end=\"19575\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"19576\" data-end=\"19600\">info@qualitanceindia.com<\/a><br data-start=\"19600\" data-end=\"19603\" \/><strong data-start=\"19603\" data-end=\"19615\">Website:<\/strong> <a class=\"decorated-link\" href=\"https:\/\/qualitanceindia.com\/\" target=\"_new\" rel=\"noopener\" data-start=\"19616\" data-end=\"19664\">Qualitance India<\/a><\/p>\n<hr data-start=\"19666\" data-end=\"19669\" \/>\n<h1 data-section-id=\"fjm0j9\" data-start=\"19671\" data-end=\"19694\">Certification Process<\/h1>\n<p data-start=\"19696\" data-end=\"20114\"><strong data-start=\"19696\" data-end=\"19722\">Product Identification<\/strong><br data-start=\"19722\" data-end=\"19725\" \/>\u2193<br data-start=\"19726\" data-end=\"19729\" \/><strong data-start=\"19729\" data-end=\"19766\">IS 1363 Part 1 Requirement Review<\/strong><br data-start=\"19766\" data-end=\"19769\" \/>\u2193<br data-start=\"19770\" data-end=\"19773\" \/><strong data-start=\"19773\" data-end=\"19795\">Factory Assessment<\/strong><br data-start=\"19795\" data-end=\"19798\" \/>\u2193<br data-start=\"19799\" data-end=\"19802\" \/><strong data-start=\"19802\" data-end=\"19831\">Documentation Preparation<\/strong><br data-start=\"19831\" data-end=\"19834\" \/>\u2193<br data-start=\"19835\" data-end=\"19838\" \/><strong data-start=\"19838\" data-end=\"19858\">Product Grouping<\/strong><br data-start=\"19858\" data-end=\"19861\" \/>\u2193<br data-start=\"19862\" data-end=\"19865\" \/><strong data-start=\"19865\" data-end=\"19887\">Sample Preparation<\/strong><br data-start=\"19887\" data-end=\"19890\" \/>\u2193<br data-start=\"19891\" data-end=\"19894\" \/><strong data-start=\"19894\" data-end=\"19916\">Laboratory Testing<\/strong><br data-start=\"19916\" data-end=\"19919\" \/>\u2193<br data-start=\"19920\" data-end=\"19923\" \/><strong data-start=\"19923\" data-end=\"19942\">BIS Application<\/strong><br data-start=\"19942\" data-end=\"19945\" \/>\u2193<br data-start=\"19946\" data-end=\"19949\" \/><strong data-start=\"19949\" data-end=\"19965\">BIS Scrutiny<\/strong><br data-start=\"19965\" data-end=\"19968\" \/>\u2193<br data-start=\"19969\" data-end=\"19972\" \/><strong data-start=\"19972\" data-end=\"19994\">Factory Inspection<\/strong><br data-start=\"19994\" data-end=\"19997\" \/>\u2193<br data-start=\"19998\" data-end=\"20001\" \/><strong data-start=\"20001\" data-end=\"20027\">Test Report Evaluation<\/strong><br data-start=\"20027\" data-end=\"20030\" \/>\u2193<br data-start=\"20031\" data-end=\"20034\" \/><strong data-start=\"20034\" data-end=\"20057\">Observation Closure<\/strong><br data-start=\"20057\" data-end=\"20060\" \/>\u2193<br data-start=\"20061\" data-end=\"20064\" \/><strong data-start=\"20064\" data-end=\"20079\">BIS Licence<\/strong><br data-start=\"20079\" data-end=\"20082\" \/>\u2193<br data-start=\"20083\" data-end=\"20086\" \/><strong data-start=\"20086\" data-end=\"20114\">Standard Mark Compliance<\/strong><\/p>\n<hr data-start=\"20116\" data-end=\"20119\" \/>\n<h1 data-section-id=\"hkd5a4\" data-start=\"20121\" data-end=\"20149\">Frequently Asked Questions<\/h1>\n<h3 data-section-id=\"1ov2php\" data-start=\"20151\" data-end=\"20181\">1. What is IS 1363 Part 1?<\/h3>\n<p data-start=\"20183\" data-end=\"20377\">IS 1363 Part 1 is the Indian Standard for <strong data-start=\"20225\" data-end=\"20286\">Hexagon Head Bolts, Product Grade C, Size Range M5 to M64<\/strong>. The current version is <strong data-start=\"20311\" data-end=\"20336\">IS 1363 (Part 1):2023<\/strong>.<\/p>\n<h3 data-section-id=\"1r3jrmi\" data-start=\"20379\" data-end=\"20417\">2. What is the size range covered?<\/h3>\n<p data-start=\"20419\" data-end=\"20493\">The standard covers <strong data-start=\"20439\" data-end=\"20452\">M5 to M64<\/strong>.<\/p>\n<h3 data-section-id=\"1040b52\" data-start=\"20495\" data-end=\"20532\">3. What product grade is covered?<\/h3>\n<p data-start=\"20534\" data-end=\"20633\">The standard covers <strong data-start=\"20554\" data-end=\"20573\">Product Grade C<\/strong> Hexagon Head Bolts.<\/p>\n<h3 data-section-id=\"16svimk\" data-start=\"20635\" data-end=\"20676\">4. What property classes are covered?<\/h3>\n<p data-start=\"20678\" data-end=\"20844\">The current Product Manual identifies <strong data-start=\"20716\" data-end=\"20763\">4.6, 4.8 or as declared by the manufacturer<\/strong>, subject to the applicable requirements.<\/p>\n<h3 data-section-id=\"6m0y0m\" data-start=\"20846\" data-end=\"20906\">5. Is BIS Certification required for Hexagon Head Bolts?<\/h3>\n<p data-start=\"20908\" data-end=\"21098\">IS 1363 Part 1 is listed by BIS under Scheme-I in the Bolts, Nuts and Fasteners category and is associated with the applicable Quality Control Orders.<\/p>\n<h3 data-section-id=\"ds9wmo\" data-start=\"21100\" data-end=\"21151\">6. What is the current version of the standard?<\/h3>\n<p data-start=\"21153\" data-end=\"21272\">The current BIS standard database identifies <strong data-start=\"21198\" data-end=\"21221\">IS 1363 Part 1:2023<\/strong> as active.<\/p>\n<h3 data-section-id=\"lvswxt\" data-start=\"21274\" data-end=\"21311\">7. How many samples are required?<\/h3>\n<p data-start=\"21313\" data-end=\"21421\">The current Product Manual specifies <strong data-start=\"21350\" data-end=\"21361\">6 bolts<\/strong> as the sample size.<\/p>\n<h3 data-section-id=\"qj9qqu\" data-start=\"21423\" data-end=\"21455\">8. What tests are performed?<\/h3>\n<p data-start=\"21457\" data-end=\"21669\">Testing can cover dimensions, general requirements, thread, mechanical properties, tolerances, surface condition, surface integrity, acceptability, marking and designation.<\/p>\n<h3 data-section-id=\"7pkdb9\" data-start=\"21671\" data-end=\"21705\">9. Is thread testing required?<\/h3>\n<p data-start=\"21707\" data-end=\"21810\">Yes. Thread is included in the applicable testing requirements.<\/p>\n<h3 data-section-id=\"rhu63h\" data-start=\"21812\" data-end=\"21853\">10. Are mechanical properties tested?<\/h3>\n<p data-start=\"21855\" data-end=\"21969\">Yes. Mechanical properties are included among the applicable requirements.<\/p>\n<h3 data-section-id=\"1doubtk\" data-start=\"21971\" data-end=\"22008\">11. Is surface integrity checked?<\/h3>\n<p data-start=\"22010\" data-end=\"22124\">Yes. Surface integrity is one of the testing areas identified by BIS LIMS.<\/p>\n<h3 data-section-id=\"p7sueq\" data-start=\"22126\" data-end=\"22154\">12. Is marking required?<\/h3>\n<p data-start=\"22156\" data-end=\"22224\">Yes. Applicable marking and labelling requirements must be followed.<\/p>\n<h3 data-section-id=\"16u5xky\" data-start=\"22226\" data-end=\"22275\">13. Can M5 to M64 be included in one licence?<\/h3>\n<p data-start=\"22277\" data-end=\"22521\">The licence scope depends on applicable BIS product grouping, representative sampling, property class and manufacturing\/testing capabilities. The Product Manual provides grouping guidelines under Annex A.<\/p>\n<h3 data-section-id=\"q2k4u6\" data-start=\"22523\" data-end=\"22560\">14. What is the BIS testing cost?<\/h3>\n<p data-start=\"22562\" data-end=\"22760\">Testing costs vary according to the laboratory and scope. Current BIS LIMS listings show examples of \u20b914,000 and \u20b915,000 excluding taxes for specified scopes.<\/p>\n<h3 data-section-id=\"eaj1m\" data-start=\"22762\" data-end=\"22801\">15. Is factory inspection required?<\/h3>\n<p data-start=\"22803\" data-end=\"22880\">Factory assessment can form part of the applicable BIS certification process.<\/p>\n<h3 data-section-id=\"8ugzp5\" data-start=\"22882\" data-end=\"22918\">16. What documents are required?<\/h3>\n<p data-start=\"22920\" data-end=\"23091\">Documents can include factory details, product drawings, machinery information, raw-material details, testing equipment, calibration records and quality-control documents.<\/p>\n<h3 data-section-id=\"i29dui\" data-start=\"23093\" data-end=\"23133\">17. Who can apply for certification?<\/h3>\n<p data-start=\"23135\" data-end=\"23262\">Eligible manufacturers producing the applicable Hexagon Head Bolts can apply under the relevant BIS certification requirements.<\/p>\n<h3 data-section-id=\"b6kqkq\" data-start=\"23264\" data-end=\"23303\">18. Can different sizes be covered?<\/h3>\n<p data-start=\"23305\" data-end=\"23414\">Different sizes can be included according to the applicable grouping requirements and approved licence scope.<\/p>\n<h3 data-section-id=\"zh5exe\" data-start=\"23416\" data-end=\"23448\">19. What is Product Grade C?<\/h3>\n<p data-start=\"23450\" data-end=\"23550\">Product Grade C is the product grade specified for the Hexagon Head Bolts covered by IS 1363 Part 1.<\/p>\n<h3 data-section-id=\"5217r0\" data-start=\"23552\" data-end=\"23609\">20. Can Qualitance India help with BIS certification?<\/h3>\n<p data-start=\"23611\" data-end=\"23786\">Yes. Qualitance India can assist with product assessment, documentation, product grouping, laboratory testing coordination, BIS application and factory inspection preparation.<\/p>\n<hr data-start=\"23788\" data-end=\"23791\" \/>\n<h1 data-section-id=\"g38lxp\" data-start=\"23793\" data-end=\"23810\">People Also Ask<\/h1>\n<h3 data-section-id=\"a8118y\" data-start=\"23812\" data-end=\"23839\">What is IS 1363 Part 1?<\/h3>\n<p data-start=\"23841\" data-end=\"23967\">It is the Indian Standard covering <strong data-start=\"23876\" data-end=\"23926\">Hexagon Head Bolts, Product Grade C, M5 to M64<\/strong>.<\/p>\n<h3 data-section-id=\"1krtoyg\" data-start=\"23969\" data-end=\"24030\">What is the difference between IS 1363 Part 1 and Part 2?<\/h3>\n<p data-start=\"24032\" data-end=\"24249\"><strong data-start=\"24032\" data-end=\"24042\">Part 1<\/strong> covers Hexagon Head Bolts, while <strong data-start=\"24076\" data-end=\"24086\">Part 2<\/strong> covers Hexagon Head Screws in the M5 to M64 range. BIS lists both separately under the Bolts, Nuts and Fasteners category.<\/p>\n<h3 data-section-id=\"1iy5zgs\" data-start=\"24251\" data-end=\"24299\">What sizes are covered under IS 1363 Part 1?<\/h3>\n<p data-start=\"24301\" data-end=\"24344\">The applicable size range is <strong data-start=\"24330\" data-end=\"24343\">M5 to M64<\/strong>.<\/p>\n<h3 data-section-id=\"1ld5hbh\" data-start=\"24346\" data-end=\"24386\">What grade are IS 1363 Part 1 bolts?<\/h3>\n<p data-start=\"24388\" data-end=\"24447\">The standard covers <strong data-start=\"24408\" data-end=\"24427\">Product Grade C<\/strong> Hexagon Head Bolts.<\/p>\n<h3 data-section-id=\"wmgjdb\" data-start=\"24449\" data-end=\"24498\">Is ISI Mark applicable to Hexagon Head Bolts?<\/h3>\n<p data-start=\"24500\" data-end=\"24647\">The product is listed under BIS Scheme-I and the applicable Bolts, Nuts and Fasteners regulatory framework.<\/p>\n<h3 data-section-id=\"teeb0u\" data-start=\"24649\" data-end=\"24700\">What tests are required for Hexagon Head Bolts?<\/h3>\n<p data-start=\"24702\" data-end=\"24900\">Testing can include dimensions, threads, mechanical properties, tolerances, surface condition and surface integrity, along with other applicable requirements.<\/p>\n<hr data-start=\"24902\" data-end=\"24905\" \/>\n<h1 data-section-id=\"m4n0jr\" data-start=\"24907\" data-end=\"24927\">Website Image Text<\/h1>\n<p data-start=\"24929\" data-end=\"24951\"><strong data-start=\"24929\" data-end=\"24951\">HEXAGON HEAD BOLTS<\/strong><\/p>\n<p data-start=\"24953\" data-end=\"24978\"><strong data-start=\"24953\" data-end=\"24978\">IS 1363 (PART 1):2023<\/strong><\/p>\n<p data-start=\"24980\" data-end=\"25005\"><strong data-start=\"24980\" data-end=\"25005\">SIZE RANGE: M5 TO M64<\/strong><\/p>\n<p data-start=\"25007\" data-end=\"25026\"><strong data-start=\"25007\" data-end=\"25026\">PRODUCT GRADE C<\/strong><\/p>\n<p data-start=\"25028\" data-end=\"25061\"><strong data-start=\"25028\" data-end=\"25061\">BIS CERTIFICATION CONSULTANCY<\/strong><\/p>\n<p data-start=\"25063\" data-end=\"25151\"><strong data-start=\"25063\" data-end=\"25083\">Qualitance India<\/strong><br data-start=\"25083\" data-end=\"25086\" \/>+91-9310-615-170<br data-start=\"25102\" data-end=\"25105\" \/><a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"25105\" data-end=\"25129\">info@qualitanceindia.com<\/a><br data-start=\"25129\" data-end=\"25132\" \/>qualitanceindia.com<\/p>\n<hr data-start=\"25153\" data-end=\"25156\" \/>\n<h1 data-section-id=\"rt22h1\" data-start=\"25158\" data-end=\"25174\">Image ALT Text<\/h1>\n<ol data-start=\"25176\" data-end=\"25747\">\n<li data-section-id=\"s76snx\" data-start=\"25176\" data-end=\"25219\">BIS Certification for Hexagon Head Bolts<\/li>\n<li data-section-id=\"174idi6\" data-start=\"25220\" data-end=\"25256\">Hexagon Head Bolts IS 1363 Part 1<\/li>\n<li data-section-id=\"fmh7mw\" data-start=\"25257\" data-end=\"25288\">Hexagon Head Bolts M5 to M64<\/li>\n<li data-section-id=\"1maf7sb\" data-start=\"25289\" data-end=\"25326\">BIS Licence for Hexagon Head Bolts<\/li>\n<li data-section-id=\"lnmux0\" data-start=\"25327\" data-end=\"25363\">IS 1363 Part 1:2023 Certification<\/li>\n<li data-section-id=\"1ok7lvg\" data-start=\"25364\" data-end=\"25401\">Product Grade C Hexagon Head Bolts<\/li>\n<li data-section-id=\"2rf8cb\" data-start=\"25402\" data-end=\"25435\">Hexagon Bolt BIS Certification<\/li>\n<li data-section-id=\"p259re\" data-start=\"25436\" data-end=\"25464\">Hexagon Head Bolt Testing<\/li>\n<li data-section-id=\"1ususzf\" data-start=\"25465\" data-end=\"25494\">Hexagon Head Bolt ISI Mark<\/li>\n<li data-section-id=\"14ucuq8\" data-start=\"25495\" data-end=\"25530\">Hexagon Bolt Mechanical Testing<\/li>\n<li data-section-id=\"1ffwwok\" data-start=\"25531\" data-end=\"25562\">Hexagon Bolt Thread Testing<\/li>\n<li data-section-id=\"680gvf\" data-start=\"25563\" data-end=\"25605\">Hexagon Bolt Surface Integrity Testing<\/li>\n<li data-section-id=\"vqzxef\" data-start=\"25606\" data-end=\"25652\">Bolts Nuts and Fasteners BIS Certification<\/li>\n<li data-section-id=\"1qiefwl\" data-start=\"25653\" data-end=\"25699\">Hexagon Head Bolt Manufacturer BIS Licence<\/li>\n<li data-section-id=\"1pfdmu\" data-start=\"25700\" data-end=\"25747\">Qualitance India Hexagon Bolt Certification<\/li>\n<\/ol>\n<hr data-start=\"25749\" data-end=\"25752\" \/>\n<h1 data-section-id=\"1mk48w7\" data-start=\"25754\" data-end=\"25772\">Related Services<\/h1>\n<ul data-start=\"25774\" data-end=\"26076\">\n<li data-section-id=\"18of9wh\" data-start=\"25774\" data-end=\"25805\">BIS Certification Consultancy<\/li>\n<li data-section-id=\"1iysnjj\" data-start=\"25806\" data-end=\"25833\">BIS Licence for Fasteners<\/li>\n<li data-section-id=\"4q33qt\" data-start=\"25834\" data-end=\"25863\">BIS Certification for Bolts<\/li>\n<li data-section-id=\"402knk\" data-start=\"25864\" data-end=\"25894\">BIS Certification for Screws<\/li>\n<li data-section-id=\"ua870v\" data-start=\"25895\" data-end=\"25923\">BIS Certification for Nuts<\/li>\n<li data-section-id=\"oaqr2l\" data-start=\"25924\" data-end=\"25945\">BIS Product Testing<\/li>\n<li data-section-id=\"ffrh22\" data-start=\"25946\" data-end=\"25970\">BIS Factory Inspection<\/li>\n<li data-section-id=\"nf47x2\" data-start=\"25971\" data-end=\"25995\">ISI Mark Certification<\/li>\n<li data-section-id=\"1cux2uk\" data-start=\"25996\" data-end=\"26020\">Fastener Certification<\/li>\n<li data-section-id=\"1ijpc3z\" data-start=\"26021\" data-end=\"26076\">BIS Certification under Bolts, Nuts and Fasteners QCO<\/li>\n<\/ul>\n<hr data-start=\"26078\" data-end=\"26081\" \/>\n<h1 data-section-id=\"vp4xr1\" data-start=\"26083\" data-end=\"26104\">Related Blog Topics<\/h1>\n<ol data-start=\"26106\" data-end=\"26707\">\n<li data-section-id=\"1w1pw9f\" data-start=\"26106\" data-end=\"26167\">BIS Certification for Hexagon Head Screws \u2013 IS 1363 Part 2<\/li>\n<li data-section-id=\"1klwdqe\" data-start=\"26168\" data-end=\"26222\">BIS Certification for Hexagon Nuts \u2013 IS 1363 Part 3<\/li>\n<li data-section-id=\"1p4i4am\" data-start=\"26223\" data-end=\"26298\">BIS Certification for Hexagon Head Bolts Grades A and B \u2013 IS 1364 Part 1<\/li>\n<li data-section-id=\"1pciqwh\" data-start=\"26299\" data-end=\"26360\">BIS Certification for Hexagon Head Screws \u2013 IS 1364 Part 2<\/li>\n<li data-section-id=\"1rwx8yo\" data-start=\"26361\" data-end=\"26407\">BIS Certification for Step Bolts \u2013 IS 10238<\/li>\n<li data-section-id=\"1c9zjx2\" data-start=\"26408\" data-end=\"26468\">BIS Certification for Transmission Tower Bolts \u2013 IS 12427<\/li>\n<li data-section-id=\"1ukbxco\" data-start=\"26469\" data-end=\"26534\">BIS Certification for High Strength Structural Bolts \u2013 IS 3757<\/li>\n<li data-section-id=\"1eheqiy\" data-start=\"26535\" data-end=\"26599\">BIS Certification for High Strength Structural Nuts \u2013 IS 6623<\/li>\n<li data-section-id=\"j7c0q\" data-start=\"26600\" data-end=\"26655\">BIS Certification Process for Fastener Manufacturers<\/li>\n<li data-section-id=\"1pxu4f0\" data-start=\"26656\" data-end=\"26707\">Bolts, Nuts and Fasteners Quality Control Order<\/li>\n<\/ol>\n<hr data-start=\"26709\" data-end=\"26712\" \/>\n<h1 data-section-id=\"1fwdris\" data-start=\"26714\" data-end=\"26762\">Need BIS Certification for Hexagon Head Bolts?<\/h1>\n<p data-start=\"26764\" data-end=\"27013\">If you manufacture <strong data-start=\"26783\" data-end=\"26820\">Hexagon Head Bolts from M5 to M64<\/strong> and require assistance with BIS certification, product grouping, testing, documentation or factory inspection preparation, <strong data-start=\"26944\" data-end=\"26964\">Qualitance India<\/strong> can assist throughout the certification process.<\/p>\n<p data-start=\"27015\" data-end=\"27147\"><strong data-start=\"27015\" data-end=\"27025\">Phone:<\/strong> +91-9310-615-170<br data-start=\"27042\" data-end=\"27045\" \/><strong data-start=\"27045\" data-end=\"27055\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"27056\" data-end=\"27080\">info@qualitanceindia.com<\/a><br data-start=\"27080\" data-end=\"27083\" \/><strong data-start=\"27083\" data-end=\"27095\">Website:<\/strong> <a class=\"decorated-link\" href=\"https:\/\/qualitanceindia.com\/\" target=\"_new\" rel=\"noopener\" data-start=\"27096\" data-end=\"27147\">qualitanceindia.com<\/a><\/p>\n<hr data-start=\"27149\" data-end=\"27152\" \/>\n<h1 data-section-id=\"fsb6xx\" data-start=\"27154\" data-end=\"27166\">Conclusion<\/h1>\n<p data-start=\"27168\" data-end=\"27469\">Hexagon Head Bolts are widely used fastening components across engineering, automobile, construction, machinery and industrial applications. <strong data-start=\"27309\" data-end=\"27334\">IS 1363 (Part 1):2023<\/strong> specifies requirements for <strong data-start=\"27362\" data-end=\"27428\">Product Grade C Hexagon Head Bolts in the M5 to M64 size range<\/strong>.<\/p>\n<p data-start=\"27471\" data-end=\"27711\">The certification requirements cover important areas such as <strong data-start=\"27532\" data-end=\"27670\">dimensions, thread, mechanical properties, tolerances, surface condition, surface integrity, marking and other applicable requirements<\/strong>.<\/p>\n<p data-start=\"27713\" data-end=\"27969\">BIS currently includes this product within the <strong data-start=\"27760\" data-end=\"27789\">Bolts, Nuts and Fasteners<\/strong> category under Scheme-I. Manufacturers should therefore carefully review the latest standard, applicable QCO requirements, product grouping and testing provisions before applying.<\/p>\n<p data-start=\"27971\" data-end=\"28216\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"27971\" data-end=\"27991\">Qualitance India<\/strong> can support manufacturers with product assessment, documentation, product grouping, laboratory testing coordination, BIS application and factory inspection preparation for Hexagon Head Bolts as per <strong data-start=\"28190\" data-end=\"28215\">IS 1363 (Part 1):2023<\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Hexagon Head Bolts are widely used fastening components in construction, engineering, automobile manufacturing, machinery, fabrication, industrial equipment and structural applications. Their six-sided head allows tightening with a suitable wrench or socket, making them suitable for applications where a reliable and secure mechanical connection is required. IS 1363 (Part 1):2023 specifies requirements for Hexagon Head [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3453,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"inline_featured_image":false,"slim_seo":{"title":"BIS Certification for Hexagon Head Bolts \u2013 IS 1363 (Part 1) - Qualitance India","description":"Introduction Hexagon Head Bolts are widely used fastening components in construction, engineering, automobile manufacturing, machinery, fabrication, industrial"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3452","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3452"}],"version-history":[{"count":2,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3452\/revisions"}],"predecessor-version":[{"id":3455,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3452\/revisions\/3455"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3453"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3452"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3452"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a4cebdea01328942bf8f471. Config Timestamp: 2026-07-07 12:06:54 UTC, Cached Timestamp: 2026-09-11 19:21:43 UTC, Optimization Time: 2.1ms -->