{"id":4239,"date":"2026-10-24T11:06:13","date_gmt":"2026-10-24T11:06:13","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=4239"},"modified":"2026-10-24T09:40:23","modified_gmt":"2026-10-24T09:40:23","slug":"bis-certification-consultancy-for-ether-is-3362021-qualitance-india","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-consultancy-for-ether-is-3362021-qualitance-india\/","title":{"rendered":"BIS Certification Consultancy  for Ether | IS 336:2021 \u2013 Qualitance India"},"content":{"rendered":"<h2>Introduction: BIS Certification for Ether in India<\/h2>\n<p>Ether is a chemical product used in industrial, laboratory, pharmaceutical and other specialised applications. Depending on its grade, it may be used as a solvent or for anaesthetic applications. Because ether is highly volatile and flammable, manufacturers must pay particular attention to product quality, testing, safe handling, packaging and applicable regulatory requirements.<\/p>\n<p>In India, Ether is covered under the <strong>Ether (Quality Control) Order, 2020<\/strong>, notified by the Department of Chemicals and Petrochemicals under the Ministry of Chemicals and Fertilizers. The order requires covered products to conform to the applicable Indian Standard and bear the BIS Standard Mark under a valid licence, subject to the order&#8217;s provisions and exemptions. &lt;Cite refs={[&#8220;turn520834search42&#8243;,&#8221;turn520834search6&#8221;]}\/&gt;<\/p>\n<p>An important point for manufacturers is that the original Quality Control Order and the government\u2019s online listing refer to <strong>IS 336:1973<\/strong>, while BIS has issued a product manual and granted a licence under <strong>IS 336:2021 \u2013 Ether: Specification<\/strong>. Manufacturers should therefore confirm the current applicable standard and regulatory position before filing an application. &lt;Cite refs={[&#8220;turn379506view0&#8243;,&#8221;turn379506view2&#8243;,&#8221;turn379506view3&#8221;]}\/&gt;<\/p>\n<p>Qualitance India provides BIS certification consultancy to help chemical manufacturers understand the applicable requirements, prepare technical documentation, coordinate product testing and navigate the BIS licensing process.<\/p>\n<h2>1. What Is Ether?<\/h2>\n<p>Ether is a chemical compound used in different industrial and specialised applications. The product standard identifies two grades of ether for certification purposes:<\/p>\n<ul>\n<li><strong>Solvent grade<\/strong><\/li>\n<li><strong>Anaesthetic grade<\/strong><\/li>\n<\/ul>\n<p>The manufacturer must declare the grade intended to be covered under the licence. BIS requires samples of each proposed grade to be tested for consideration of the licence or inclusion of that grade in the existing licence scope. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<p>The intended application, grade, manufacturing process and product specifications should be clearly identified before initiating certification.<\/p>\n<h2>2. Applicable Indian Standard for Ether Certification<\/h2>\n<p>The key standard and regulatory references are summarised below.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Particular<\/th>\n<th>Details<\/th>\n<\/tr>\n<tr>\n<td>Product<\/td>\n<td>Ether<\/td>\n<\/tr>\n<tr>\n<td>Earlier standard referenced in the QCO listing<\/td>\n<td>IS 336:1973<\/td>\n<\/tr>\n<tr>\n<td>Revised standard covered by the BIS Product Manual<\/td>\n<td>IS 336:2021<\/td>\n<\/tr>\n<tr>\n<td>Standard title<\/td>\n<td>Ether \u2013 Specification<\/td>\n<\/tr>\n<tr>\n<td>Certification scheme<\/td>\n<td>BIS Scheme-I, ISI Mark Scheme<\/td>\n<\/tr>\n<tr>\n<td>Quality Control Order<\/td>\n<td>Ether (Quality Control) Order, 2020<\/td>\n<\/tr>\n<tr>\n<td>Regulatory authority<\/td>\n<td>Bureau of Indian Standards (BIS)<\/td>\n<\/tr>\n<tr>\n<td>Department responsible for the QCO<\/td>\n<td>Department of Chemicals and Petrochemicals<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The BIS Product Manual PM\/IS 336\/1, dated October 2023, specifies the certification requirements according to IS 336:2021. BIS also announced the grant of an All India First Licence under IS 336:2021 on 14 November 2023. &lt;Cite refs={[&#8220;turn379506view0&#8243;,&#8221;turn379506view3&#8221;]}\/&gt;<\/p>\n<h3>Important clarification about IS 336:1973<\/h3>\n<p>The government\u2019s online petrochemicals QCO listing continues to display IS 336:1973, while the BIS Product Manual covers IS 336:2021. These references should not be treated as interchangeable without verification.<\/p>\n<p>Before applying, manufacturers should confirm the current standard edition, applicable amendments and the implementation of any revision under the Ether Quality Control Order with BIS or the relevant regulatory authority.<\/p>\n<h2>3. Is BIS Certification Mandatory for Ether?<\/h2>\n<p>The Ether (Quality Control) Order, 2020 requires the products covered by the order to conform to the corresponding Indian Standard and bear the Standard Mark under a BIS licence in accordance with Scheme-I of the BIS (Conformity Assessment) Regulations, 2018. The order excludes goods or articles meant for export from its application. &lt;Cite refs={[&#8220;turn520834search42&#8221;]}\/&gt;<\/p>\n<p>The Department of Chemicals and Petrochemicals lists the Ether QCO with its original notification and subsequent amendments. The government\u2019s implementation listing records 25 December 2021 as the enforcement date following amendments. &lt;Cite refs={[&#8220;turn379506view2&#8243;,&#8221;turn520834search11&#8221;]}\/&gt;<\/p>\n<p>Businesses should assess the following before manufacturing, importing, distributing or selling ether in India:<\/p>\n<ul>\n<li>Whether the product falls within the scope of the applicable standard and QCO.<\/li>\n<li>Which edition of IS 336 applies to the proposed certification.<\/li>\n<li>Whether the intended grade is solvent or anaesthetic.<\/li>\n<li>Whether a specific exemption applies to the product or transaction.<\/li>\n<li>Whether the manufacturing facility and testing arrangements meet the applicable BIS requirements.<\/li>\n<\/ul>\n<p>Manufacturers should not assume that certification is optional simply because the product is supplied to another business or sold for industrial use.<\/p>\n<h2>4. Grades of Ether Covered Under BIS Certification<\/h2>\n<p>The BIS Product Manual for IS 336:2021 identifies two grades: solvent and anaesthetic. The manufacturer must declare which grade or grades it intends to include in the licence scope. Samples of each grade must be drawn and tested for grant of licence or inclusion of the grade. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Grade<\/th>\n<th>Certification consideration<\/th>\n<\/tr>\n<tr>\n<td>Solvent grade<\/td>\n<td>The manufacturer must demonstrate conformity with the applicable specification for this grade.<\/td>\n<\/tr>\n<tr>\n<td>Anaesthetic grade<\/td>\n<td>The manufacturer must demonstrate conformity with the applicable specification for this grade.<\/td>\n<\/tr>\n<tr>\n<td>Both grades<\/td>\n<td>Each proposed grade must be addressed in the testing and licence-scope assessment.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The manufacturer should identify all intended grades at the outset. The final scope of the BIS licence depends on the applicable standard, testing results and BIS assessment.<\/p>\n<h2>5. Key Quality and Testing Requirements Under IS 336:2021<\/h2>\n<p>The BIS Product Manual identifies several tests and related equipment for evaluating ether. The exact acceptance limits and methods must be taken from the applicable edition of IS 336 and its amendments.<\/p>\n<p>Key parameters identified in the product manual include:<\/p>\n<h3>A. Description and odour<\/h3>\n<p>The product is examined for the specified description and odour characteristics.<\/p>\n<h3>B. Solubility<\/h3>\n<p>Solubility is evaluated using the reagents and method prescribed in the standard.<\/p>\n<h3>C. Relative density<\/h3>\n<p>Relative density is determined using the specified apparatus and temperature conditions.<\/p>\n<h3>D. Peroxides<\/h3>\n<p>The product is tested for peroxides in accordance with the prescribed test method.<\/p>\n<h3>E. Distillation range<\/h3>\n<p>The distillation range is evaluated using the specified distillation apparatus and relevant measurement equipment.<\/p>\n<h3>F. Residue on evaporation<\/h3>\n<p>The product is assessed for residue remaining after evaporation using the prescribed method.<\/p>\n<h3>G. Methyl alcohol<\/h3>\n<p>The standard includes a test for methyl alcohol.<\/p>\n<h3>H. Aldehydes and acetone<\/h3>\n<p>The applicable testing programme includes checks for aldehydes and acetone.<\/p>\n<h3>I. Sulphurous acid and other free acids<\/h3>\n<p>The product is evaluated for the specified acidic impurities. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<p>Manufacturers should establish a testing plan that covers every applicable requirement. A product should not be considered compliant solely on the basis of a supplier certificate or a limited set of routine tests.<\/p>\n<h2>6. BIS Sample Quantity for Ether<\/h2>\n<p>According to the BIS Product Manual PM\/IS 336\/1, the specified sample quantity is <strong>one litre<\/strong>. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Requirement<\/th>\n<th>Details<\/th>\n<\/tr>\n<tr>\n<td>Product<\/td>\n<td>Ether<\/td>\n<\/tr>\n<tr>\n<td>Sample quantity listed in the manual<\/td>\n<td>1 litre<\/td>\n<\/tr>\n<tr>\n<td>Grade selection<\/td>\n<td>Solvent and\/or anaesthetic<\/td>\n<\/tr>\n<tr>\n<td>Testing approach<\/td>\n<td>Applicable tests for the declared grade<\/td>\n<\/tr>\n<tr>\n<td>Additional requirement<\/td>\n<td>Confirm sampling, packaging and dispatch instructions before sending the sample<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The manufacturer should confirm the current sampling procedure and dispatch instructions with the relevant BIS office or laboratory before submitting the sample.<\/p>\n<p>Because ether is volatile and highly flammable, the sample must be handled, packed, labelled and transported in accordance with applicable safety requirements. Use an authorised and suitably equipped facility for sampling and testing.<\/p>\n<h2>7. Documents Required for BIS Certification of Ether<\/h2>\n<p>A successful application requires accurate business, manufacturing, technical and quality-control information. The final document checklist should be prepared against the latest BIS application requirements and the applicable product manual.<\/p>\n<h3>A. Company and manufacturing documents<\/h3>\n<ul>\n<li>Company registration or constitution documents.<\/li>\n<li>Manufacturer\u2019s name and registered address.<\/li>\n<li>Manufacturing facility address.<\/li>\n<li>Details of the authorised signatory.<\/li>\n<li>Applicable identity and address documents.<\/li>\n<li>Details of the manufacturing unit and production capacity.<\/li>\n<\/ul>\n<h3>B. Product and technical documents<\/h3>\n<ul>\n<li>Product description and proposed licence scope.<\/li>\n<li>Declaration of the intended ether grade.<\/li>\n<li>Applicable Indian Standard details.<\/li>\n<li>Product specification and quality parameters.<\/li>\n<li>Manufacturing process flow chart.<\/li>\n<li>Raw-material details and supplier information.<\/li>\n<li>Product packaging and labelling information.<\/li>\n<li>Details of any stabiliser used, where applicable.<\/li>\n<\/ul>\n<p>The BIS Product Manual requires an undertaking concerning the material being essentially diethyl ether and provides for declaration on the container label when a suitable stabiliser is used within the prescribed limit. The precise requirements must be checked against the current standard. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<h3>C. Machinery and testing facilities<\/h3>\n<ul>\n<li>List of manufacturing equipment.<\/li>\n<li>List of testing equipment and instruments.<\/li>\n<li>Equipment specifications and identification details.<\/li>\n<li>Calibration plan and relevant calibration records.<\/li>\n<li>Details of testing facilities and personnel.<\/li>\n<li>External testing arrangements, where permitted by the applicable requirements.<\/li>\n<\/ul>\n<h3>D. Quality-control documents<\/h3>\n<ul>\n<li>Quality-control procedures.<\/li>\n<li>Raw-material inspection records.<\/li>\n<li>In-process inspection procedures.<\/li>\n<li>Finished-product testing formats.<\/li>\n<li>Batch identification and traceability records.<\/li>\n<li>Procedures for handling non-conforming products.<\/li>\n<li>Product release and record-retention procedures.<\/li>\n<\/ul>\n<h3>E. Safety, packaging and labelling information<\/h3>\n<ul>\n<li>Applicable product labels.<\/li>\n<li>Packaging details.<\/li>\n<li>Flammability warning and relevant hazard information.<\/li>\n<li>Storage and handling arrangements.<\/li>\n<li>Any additional declarations or undertakings required by BIS.<\/li>\n<\/ul>\n<p>This is a preparation checklist rather than an exhaustive list of mandatory documents for every application. BIS may require additional documents based on the facility, proposed licence scope and applicable certification procedure.<\/p>\n<h2>8. BIS Certification Process for Ether<\/h2>\n<p>The process generally involves the following stages.<\/p>\n<h3>Step 1: Regulatory and standard applicability assessment<\/h3>\n<p>The manufacturer\u2019s product and intended grade are reviewed against the applicable Indian Standard and Ether Quality Control Order. The discrepancy between the older QCO reference and the revised BIS product manual should be resolved before proceeding.<\/p>\n<h3>Step 2: Manufacturing facility assessment<\/h3>\n<p>The manufacturing process, raw materials, production controls, testing equipment, quality-control arrangements and safety provisions are reviewed to identify compliance gaps.<\/p>\n<h3>Step 3: Documentation preparation<\/h3>\n<p>The relevant business and technical documents are compiled. The product description, declared grade, manufacturing details and proposed licence scope are checked for consistency.<\/p>\n<h3>Step 4: BIS application submission<\/h3>\n<p>The application is prepared and submitted through the applicable BIS procedure, along with the required information and prescribed fees.<\/p>\n<h3>Step 5: Factory inspection<\/h3>\n<p>BIS assesses the manufacturing infrastructure, process controls, quality-control arrangements and testing capabilities as required by the applicable certification procedure. BIS explains that licensing decisions are based on assessment of the manufacturing premises and conformity of the product to the relevant standard. &lt;Cite refs={[&#8220;turn520834search10&#8221;]}\/&gt;<\/p>\n<h3>Step 6: Product sampling and testing<\/h3>\n<p>The applicable sample is drawn or submitted and tested against the relevant requirements. Each grade proposed for inclusion must be addressed in the testing plan.<\/p>\n<h3>Step 7: Closure of observations<\/h3>\n<p>Any observations or non-conformities identified during assessment or testing must be addressed with appropriate corrective actions and supporting evidence.<\/p>\n<h3>Step 8: Grant of BIS licence<\/h3>\n<p>If BIS is satisfied that all applicable requirements have been met, it may grant the licence. The manufacturer must comply with the licence scope, marking provisions and continuing obligations.<\/p>\n<p>The timeline depends on documentation readiness, inspection scheduling, testing and closure of observations. Application submission does not guarantee approval or a fixed grant date.<\/p>\n<h2>9. Manufacturing, Testing and Quality-Control Requirements<\/h2>\n<p>The BIS Product Manual sets out requirements relating to laboratory facilities, calibration planning, test records, packing, marking, control units and levels of control. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<p>Manufacturers should pay particular attention to the following areas.<\/p>\n<p><strong>Laboratory facilities:<\/strong> Maintain suitable equipment and trained personnel for the tests required by the applicable standard.<\/p>\n<p><strong>Calibration:<\/strong> Prepare and implement a calibration plan for relevant testing equipment.<\/p>\n<p><strong>Batch identification:<\/strong> Establish a control-unit and batch traceability system consistent with the applicable Scheme of Inspection and Testing.<\/p>\n<p><strong>Testing records:<\/strong> Maintain documented records showing that production conforms to the applicable requirements.<\/p>\n<p><strong>Packaging and marking:<\/strong> Ensure that containers meet the applicable packaging and marking provisions, including the licence number and required information.<\/p>\n<p><strong>Flammability warnings:<\/strong> The product manual specifies a \u201cFLAMMABLE\u201d caution label with the corresponding dangerous-goods symbol as prescribed in the referenced standard. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<p><strong>Non-conforming products:<\/strong> Establish a documented process for identifying and disposing of products that do not meet the requirements, without violating applicable legal provisions.<\/p>\n<p>Because ether is highly flammable, operational safety measures must be established alongside quality-control procedures. Certification preparation should not replace applicable fire-safety, chemical-handling, storage, transport or other statutory obligations.<\/p>\n<h2>10. BIS Certification Fees for Ether<\/h2>\n<p>The total cost of BIS certification depends on the applicable fee schedule, testing requirements, facility readiness and consultancy scope.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Cost component<\/th>\n<th>Description<\/th>\n<\/tr>\n<tr>\n<td>BIS application fees<\/td>\n<td>Prescribed fees under the current BIS schedule<\/td>\n<\/tr>\n<tr>\n<td>Product testing charges<\/td>\n<td>Charges for applicable tests and laboratory services<\/td>\n<\/tr>\n<tr>\n<td>Inspection-related expenses<\/td>\n<td>Expenses associated with applicable assessments<\/td>\n<\/tr>\n<tr>\n<td>Consultancy charges<\/td>\n<td>Professional support for documentation and certification preparation<\/td>\n<\/tr>\n<tr>\n<td>Testing equipment<\/td>\n<td>Costs of procuring or upgrading required equipment<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>Costs associated with maintaining measurement and testing equipment<\/td>\n<\/tr>\n<tr>\n<td>Corrective actions<\/td>\n<td>Expenses for closing identified compliance gaps<\/td>\n<\/tr>\n<tr>\n<td>Licence-related fees<\/td>\n<td>Applicable licence, marking or renewal-related charges<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The BIS Laboratory Information Management System provides laboratory and testing information, but fees and availability should be confirmed directly before preparing a project budget. &lt;Cite refs={[&#8220;turn520834search8&#8221;]}\/&gt;<\/p>\n<p>For an accurate quotation, manufacturers should identify the grade or grades, the facility location, the existing testing capabilities and the intended licence scope.<\/p>\n<h2>11. Common Challenges in Ether BIS Certification<\/h2>\n<p>Manufacturers may face delays when the product scope, testing arrangements or documentation are incomplete.<\/p>\n<p>Common challenges include:<\/p>\n<p><strong>Using an outdated standard reference:<\/strong> The original QCO listing and revised product manual refer to different editions. The applicable standard should be confirmed before filing.<\/p>\n<p><strong>Incomplete testing facilities:<\/strong> The manufacturing unit may not have the required equipment, calibration arrangements or trained personnel.<\/p>\n<p><strong>Insufficient batch records:<\/strong> Test results may not be adequately linked to the relevant production batches.<\/p>\n<p><strong>Unclear grade declaration:<\/strong> The intended solvent or anaesthetic grade may not be clearly defined in the proposed licence scope.<\/p>\n<p><strong>Incorrect packaging or marking:<\/strong> Container labels may omit mandatory information or applicable flammability warnings.<\/p>\n<p><strong>Inadequate safety arrangements:<\/strong> Storage, handling, sampling and transportation arrangements may not be appropriate for a highly flammable product.<\/p>\n<p>A pre-assessment can help identify these gaps and organise corrective actions before the formal certification process.<\/p>\n<h2>12. Why Choose Qualitance India for Ether BIS Certification Consultancy?<\/h2>\n<p>Qualitance India provides consultancy support for BIS product certification, regulatory compliance and laboratory-related requirements.<\/p>\n<p>Our support can include:<\/p>\n<ul>\n<li>Initial assessment of Ether BIS certification requirements.<\/li>\n<li>Review of IS 336:2021 and applicable QCO references.<\/li>\n<li>Assistance in identifying the appropriate licence scope.<\/li>\n<li>Preparation and review of application documentation.<\/li>\n<li>Review of manufacturing and quality-control arrangements.<\/li>\n<li>Testing coordination and sample-submission guidance.<\/li>\n<li>Factory inspection preparation.<\/li>\n<li>Support in responding to observations and addressing documentation gaps.<\/li>\n<li>Guidance on product marking and continuing compliance obligations.<\/li>\n<\/ul>\n<p>Our approach is tailored to the manufacturer&#8217;s product grade, facility readiness and project requirements. Statutory fees, testing charges and other third-party expenses should be identified separately in the commercial proposal.<\/p>\n<h2>13. Frequently Asked Questions (FAQs)<\/h2>\n<h3>Q1. Which Indian Standard applies to Ether BIS certification?<\/h3>\n<p>BIS has issued a product manual for Ether under IS 336:2021. The original Ether Quality Control Order and the government\u2019s online listing reference IS 336:1973, so manufacturers should verify the applicable edition and regulatory position before applying. &lt;Cite refs={[&#8220;turn379506view0&#8243;,&#8221;turn379506view2&#8221;]}\/&gt;<\/p>\n<h3>Q2. Is BIS certification mandatory for Ether in India?<\/h3>\n<p>The Ether Quality Control Order, 2020 makes BIS certification compulsory for products covered by the order, subject to its provisions and exemptions. The original order excludes goods or articles meant for export. &lt;Cite refs={[&#8220;turn520834search42&#8221;]}\/&gt;<\/p>\n<h3>Q3. What are the grades of Ether under IS 336:2021?<\/h3>\n<p>The BIS Product Manual identifies solvent and anaesthetic grades. The manufacturer must declare the grade or grades intended to be included in the licence scope. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<h3>Q4. What is the sample quantity for Ether certification?<\/h3>\n<p>The BIS Product Manual lists a sample quantity of one litre. The manufacturer should confirm the current sampling and dispatch instructions with the relevant BIS office or laboratory. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<h3>Q5. What tests are relevant to Ether certification?<\/h3>\n<p>The product manual identifies tests including description, odour, solubility, relative density, peroxides, distillation range, residue on evaporation, methyl alcohol, aldehydes and acetone, and sulphurous acid and other free acids. The exact requirements and limits must be checked against the applicable standard. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<h3>Q6. Can a manufacturer obtain a licence for both grades?<\/h3>\n<p>Both grades can be proposed for inclusion, but each grade must be declared and tested as required. BIS determines the final scope of the licence in accordance with the applicable requirements. &lt;Cite refs={[&#8220;turn379506view0&#8221;]}\/&gt;<\/p>\n<h3>Q7. How long does Ether BIS certification take?<\/h3>\n<p>The timeline depends on the application, manufacturing readiness, inspection, sample testing and closure of any observations. A realistic estimate should be prepared after reviewing the facility and current BIS requirements.<\/p>\n<h3>Q8. What is the cost of Ether BIS certification?<\/h3>\n<p>The cost depends on applicable BIS fees, testing charges, consultancy scope, equipment readiness and the number of grades proposed for certification. A project-specific quotation is recommended.<\/p>\n<h3>Q9. Does BIS certification remove the need for chemical safety compliance?<\/h3>\n<p>No. BIS certification does not automatically replace applicable requirements for chemical storage, fire safety, transport, workplace safety or other statutory approvals.<\/p>\n<h3>Q10. Where can manufacturers check official Ether certification information?<\/h3>\n<p>Manufacturers can consult the BIS Scheme-I compulsory-certification listing, the BIS Product Manual for IS 336:2021, the Ether Quality Control Order and the Department of Chemicals and Petrochemicals&#8217; QCO listings.<\/p>\n<h2>Official References<\/h2>\n<ol start=\"1\">\n<li><strong>BIS Product Manual for Ether \u2013 IS 336:2021:<\/strong> <a href=\"https:\/\/www.bis.gov.in\/wp-content\/uploads\/2023\/10\/PM-IS-336-final.pdf\">https:\/\/www.bis.gov.in\/wp-content\/uploads\/2023\/10\/PM-IS-336-final.pdf<\/a><\/li>\n<li><strong>Ether Quality Control Order, 2020:<\/strong> <a href=\"https:\/\/www.bis.gov.in\/wp-content\/uploads\/2020\/07\/QCO-Ether-DCPC.pdf\">https:\/\/www.bis.gov.in\/wp-content\/uploads\/2020\/07\/QCO-Ether-DCPC.pdf<\/a><\/li>\n<li><strong>Department of Chemicals and Petrochemicals \u2013 Petrochemicals Quality Control Orders:<\/strong> <a href=\"https:\/\/chemicals.gov.in\/petrochemicals-quality-control-orders\">https:\/\/chemicals.gov.in\/petrochemicals-quality-control-orders<\/a><\/li>\n<li><strong>BIS Circular \u2013 All India First Licence for Ether under IS 336:2021:<\/strong> <a href=\"https:\/\/www.bis.gov.in\/wp-content\/uploads\/2023\/11\/IS-336.pdf\">https:\/\/www.bis.gov.in\/wp-content\/uploads\/2023\/11\/IS-336.pdf<\/a><\/li>\n<li><strong>BIS Products Under Compulsory Certification:<\/strong> <a href=\"https:\/\/www.bis.gov.in\/products-under-compulsory-certification\/scheme-1\/?lang=en\">https:\/\/www.bis.gov.in\/products-under-compulsory-certification\/scheme-1\/?lang=en<\/a><\/li>\n<li><strong>BIS Laboratory Information Management System:<\/strong> <a href=\"https:\/\/lims.bis.gov.in\/\">https:\/\/lims.bis.gov.in\/<\/a><\/li>\n<\/ol>\n<div>\n<hr \/>\n<\/div>\n<h2>Contact Qualitance India for BIS Certification Consultancy for Ether<\/h2>\n<p>Are you a manufacturer of Ether looking to obtain BIS certification and comply with the applicable Indian Standard?<\/p>\n<p><strong>Qualitance India<\/strong> assists manufacturers with BIS certification consultancy, technical documentation, product testing coordination, factory assessment preparation and regulatory compliance support.<\/p>\n<p>Contact our team to discuss your manufacturing facility, product grade, proposed licence scope and the current requirements applicable to Ether certification.<\/p>\n<p><strong>Qualitance India \u2013 Improving Quality &amp; Competence<\/strong><\/p>\n<ul>\n<li><strong>Phone \/ WhatsApp:<\/strong> +91 9310615170<\/li>\n<li><strong>Email:<\/strong> <a href=\"mailto:info@qualitanceindia.com\">info@qualitanceindia.com<\/a><\/li>\n<li><strong>Website:<\/strong> <a href=\"https:\/\/qualitanceindia.com\/\">https:\/\/qualitanceindia.com<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Introduction: BIS Certification for Ether in India Ether is a chemical product used in industrial, laboratory, pharmaceutical and other specialised applications. Depending on its grade, it may be used as a solvent or for anaesthetic applications. Because ether is highly volatile and flammable, manufacturers must pay particular attention to product quality, testing, safe handling, packaging [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4240,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_forum_subforum_count":0,"inline_featured_image":false,"slim_seo":{"title":"BIS Certification Consultancy for Ether | IS 336:2021 \u2013 Qualitance India - Qualitance India","description":"Introduction: BIS Certification for Ether in India Ether is a chemical product used in industrial, laboratory, pharmaceutical and other specialised applications"},"_slim_seo_primary_term_category":1,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4239","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/4239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=4239"}],"version-history":[{"count":1,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/4239\/revisions"}],"predecessor-version":[{"id":4241,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/4239\/revisions\/4241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/4240"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=4239"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=4239"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=4239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}