{"id":3575,"date":"2026-08-27T11:20:34","date_gmt":"2026-08-27T11:20:34","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3575"},"modified":"2026-08-27T11:20:34","modified_gmt":"2026-08-27T11:20:34","slug":"bis-certification-consultancy-for-fire-resistant-steel-is-151032002-bis-isi-mark-certification","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-consultancy-for-fire-resistant-steel-is-151032002-bis-isi-mark-certification\/","title":{"rendered":"BIS Certification Consultancy for Fire Resistant Steel | IS 15103:2002 | BIS &#038; ISI Mark Certification"},"content":{"rendered":"<div class=\"flex max-w-full flex-col gap-4 grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+&amp;]:mt-1\" dir=\"auto\" tabindex=\"0\" data-message-author-role=\"assistant\" data-message-id=\"f01323b0-386b-45db-a889-65844a40c7b5\" data-turn-start-message=\"true\" data-message-model-slug=\"gpt-5-6-t-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden\">\n<div class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\">\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"13ax1s5\" data-start=\"768\" data-end=\"783\">Introduction<\/h2>\n<p data-start=\"785\" data-end=\"1109\">Fire resistant steel is specially designed for structural applications where steel components may be exposed to elevated temperatures and fluctuations in stress. Unlike ordinary structural steel, fire resistant steel is developed with controlled alloying elements to retain improved strength properties at high temperatures.<\/p>\n<p data-start=\"1111\" data-end=\"1601\">In India, <strong data-start=\"1121\" data-end=\"1177\">IS 15103:2002 \u2013 Fire Resistant Steel \u2013 Specification<\/strong> specifies requirements for fire resistant steel used in structural work. BIS&#8217;s official technical summary states that these steels are intended for structural applications up to a <strong data-start=\"1358\" data-end=\"1424\">maximum temperature of 600\u00b0C for a maximum duration of 3 hours<\/strong>. The standard covers <strong data-start=\"1446\" data-end=\"1483\">plates, strips, sections and bars<\/strong> and identifies two grades: <strong data-start=\"1511\" data-end=\"1534\">FR-Fe 410 (Grade A)<\/strong> and <strong data-start=\"1539\" data-end=\"1562\">FR-Fe 490 (Grade B)<\/strong>.<\/p>\n<p data-start=\"1603\" data-end=\"1935\">The current BIS Product Manual <strong data-start=\"1634\" data-end=\"1648\">PM\/15103\/1<\/strong> provides certification guidance under <strong data-start=\"1687\" data-end=\"1750\">Scheme-I of the BIS Conformity Assessment Regulations, 2018<\/strong>. It identifies product grouping, sampling, testing equipment and the Scheme of Inspection and Testing for manufacturers seeking BIS certification.<\/p>\n<p data-start=\"1937\" data-end=\"2132\">IS 15103:2002 is also specifically included in the <strong data-start=\"1988\" data-end=\"2046\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, with implementation <strong data-start=\"2068\" data-end=\"2093\">with immediate effect<\/strong>.<\/p>\n<p data-start=\"2134\" data-end=\"2445\"><strong data-start=\"2134\" data-end=\"2154\">Qualitance India<\/strong> provides end-to-end BIS Certification Consultancy for Fire Resistant Steel as per <strong data-start=\"2237\" data-end=\"2254\">IS 15103:2002<\/strong>, including product applicability assessment, product grouping, documentation, sample preparation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<h1 data-section-id=\"1aj837j\" data-start=\"2447\" data-end=\"2471\">What is IS 15103:2002?<\/h1>\n<p data-start=\"2473\" data-end=\"2501\"><strong data-start=\"2473\" data-end=\"2490\">IS 15103:2002<\/strong> is titled:<\/p>\n<p data-start=\"2503\" data-end=\"2545\"><strong data-start=\"2503\" data-end=\"2545\">\u201cFire Resistant Steel \u2013 Specification\u201d<\/strong><\/p>\n<p data-start=\"2547\" data-end=\"2921\">The standard specifies requirements for fire resistant steels intended for structural applications where components can be exposed to both fire and fluctuating stresses. BIS explains that fire-resistant properties are achieved through the incorporation of controlled proportions of alloying elements such as <strong data-start=\"2855\" data-end=\"2882\">chromium and molybdenum<\/strong>.<\/p>\n<p data-start=\"2923\" data-end=\"2943\">The standard covers:<\/p>\n<ul data-start=\"2945\" data-end=\"2980\">\n<li data-section-id=\"34nthz\" data-start=\"2945\" data-end=\"2953\">Plates<\/li>\n<li data-section-id=\"66dson\" data-start=\"2954\" data-end=\"2962\">Strips<\/li>\n<li data-section-id=\"m12rle\" data-start=\"2963\" data-end=\"2973\">Sections<\/li>\n<li data-section-id=\"1j423d6\" data-start=\"2974\" data-end=\"2980\">Bars<\/li>\n<\/ul>\n<p data-start=\"2982\" data-end=\"3008\">and identifies two grades:<\/p>\n<ul data-start=\"3010\" data-end=\"3099\">\n<li data-section-id=\"km109s\" data-start=\"3010\" data-end=\"3035\"><strong data-start=\"3012\" data-end=\"3035\">FR-Fe 410 \u2013 Grade A<\/strong><\/li>\n<li data-section-id=\"2pfpti\" data-start=\"3036\" data-end=\"3099\"><strong data-start=\"3038\" data-end=\"3061\">FR-Fe 490 \u2013 Grade B<\/strong><\/li>\n<\/ul>\n<p data-start=\"3101\" data-end=\"3225\">The steel products are rolled from cast material and require control of both chemical composition and mechanical properties.<\/p>\n<h1 data-section-id=\"1cs443v\" data-start=\"3227\" data-end=\"3258\">What is Fire Resistant Steel?<\/h1>\n<p data-start=\"3260\" data-end=\"3394\">Fire resistant steel is structural steel designed to maintain improved strength characteristics when exposed to elevated temperatures.<\/p>\n<p data-start=\"3396\" data-end=\"3485\">BIS&#8217;s technical summary states that IS 15103 steel is intended for structural work up to:<\/p>\n<p data-start=\"3487\" data-end=\"3569\"><strong data-start=\"3487\" data-end=\"3531\">600\u00b0C for a maximum duration of 3 hours.<\/strong><\/p>\n<p data-start=\"3571\" data-end=\"3736\">This type of steel can be useful in structures where fire exposure is a design consideration and retaining structural strength at elevated temperatures is important.<\/p>\n<p data-start=\"3738\" data-end=\"3774\">Fire resistant steel may be used in:<\/p>\n<ul data-start=\"3776\" data-end=\"3964\">\n<li data-section-id=\"16uky0g\" data-start=\"3776\" data-end=\"3798\">Structural buildings<\/li>\n<li data-section-id=\"1gmhlih\" data-start=\"3799\" data-end=\"3822\">Industrial structures<\/li>\n<li data-section-id=\"kscxd5\" data-start=\"3823\" data-end=\"3848\">Infrastructure projects<\/li>\n<li data-section-id=\"xjsb65\" data-start=\"3849\" data-end=\"3863\">Steel frames<\/li>\n<li data-section-id=\"3u31u5\" data-start=\"3864\" data-end=\"3882\">Structural beams<\/li>\n<li data-section-id=\"5wk9d9\" data-start=\"3883\" data-end=\"3892\">Columns<\/li>\n<li data-section-id=\"m12rle\" data-start=\"3893\" data-end=\"3903\">Sections<\/li>\n<li data-section-id=\"1j423d6\" data-start=\"3904\" data-end=\"3910\">Bars<\/li>\n<li data-section-id=\"160tffc\" data-start=\"3911\" data-end=\"3964\">Other structural components covered by the standard<\/li>\n<\/ul>\n<p data-start=\"3966\" data-end=\"4046\">The final application depends on the structural design and project requirements.<\/p>\n<h1 data-section-id=\"l0pr40\" data-start=\"4048\" data-end=\"4083\">Why is Fire Resistant Steel Used?<\/h1>\n<p data-start=\"4085\" data-end=\"4208\">Fire can significantly affect the mechanical properties of steel. As temperature increases, structural strength can reduce.<\/p>\n<p data-start=\"4210\" data-end=\"4369\">Fire resistant steel is designed to provide improved temperature stability through controlled composition and specified high-temperature mechanical properties.<\/p>\n<p data-start=\"4371\" data-end=\"4434\">The technical requirements of IS 15103:2002 therefore focus on:<\/p>\n<ul data-start=\"4436\" data-end=\"4612\">\n<li data-section-id=\"v16bzo\" data-start=\"4436\" data-end=\"4458\">Chemical composition<\/li>\n<li data-section-id=\"i9xgr8\" data-start=\"4459\" data-end=\"4489\">Ambient-temperature strength<\/li>\n<li data-section-id=\"zwid7m\" data-start=\"4490\" data-end=\"4521\">Elevated-temperature strength<\/li>\n<li data-section-id=\"193ooql\" data-start=\"4522\" data-end=\"4540\">Bend performance<\/li>\n<li data-section-id=\"iaa46q\" data-start=\"4541\" data-end=\"4561\">Impact performance<\/li>\n<li data-section-id=\"1g7qg16\" data-start=\"4562\" data-end=\"4584\">Freedom from defects<\/li>\n<li data-section-id=\"1f5i8ey\" data-start=\"4585\" data-end=\"4612\">Dimensions and tolerances<\/li>\n<\/ul>\n<p data-start=\"4614\" data-end=\"4788\">BIS specifically identifies high-temperature tensile testing at <strong data-start=\"4678\" data-end=\"4687\">600\u00b0C<\/strong> as an important part of the standard&#8217;s performance evaluation.<\/p>\n<h1 data-section-id=\"1f8h00l\" data-start=\"4790\" data-end=\"4842\">Grades of Fire Resistant Steel under IS 15103:2002<\/h1>\n<p data-start=\"4844\" data-end=\"4889\">IS 15103:2002 specifies two principal grades.<\/p>\n<h2 data-section-id=\"1s8x1vx\" data-start=\"4891\" data-end=\"4913\">FR-Fe 410 \u2013 Grade A<\/h2>\n<p data-start=\"4915\" data-end=\"4957\">This grade is identified as <strong data-start=\"4943\" data-end=\"4956\">FR-Fe 410<\/strong>.<\/p>\n<h2 data-section-id=\"is7dmu\" data-start=\"4959\" data-end=\"4981\">FR-Fe 490 \u2013 Grade B<\/h2>\n<p data-start=\"4983\" data-end=\"5025\">This grade is identified as <strong data-start=\"5011\" data-end=\"5024\">FR-Fe 490<\/strong>.<\/p>\n<p data-start=\"5027\" data-end=\"5116\">The BIS technical summary further notes colour identification at the ends of the product:<\/p>\n<ul data-start=\"5118\" data-end=\"5196\">\n<li data-section-id=\"1w149dd\" data-start=\"5118\" data-end=\"5138\"><strong data-start=\"5120\" data-end=\"5138\">Grade A \u2013 Blue<\/strong><\/li>\n<li data-section-id=\"g8324i\" data-start=\"5139\" data-end=\"5196\"><strong data-start=\"5141\" data-end=\"5158\">Grade B \u2013 Red<\/strong><\/li>\n<\/ul>\n<p data-start=\"5198\" data-end=\"5314\">Correct grade identification is important when preparing the BIS licence scope and selecting representative samples.<\/p>\n<h1 data-section-id=\"1u8ipg3\" data-start=\"5316\" data-end=\"5340\">Scope of IS 15103:2002<\/h1>\n<p data-start=\"5342\" data-end=\"5362\">The standard covers:<\/p>\n<ul data-start=\"5364\" data-end=\"5415\">\n<li data-section-id=\"1y2jatz\" data-start=\"5364\" data-end=\"5376\"><strong data-start=\"5366\" data-end=\"5376\">Plates<\/strong><\/li>\n<li data-section-id=\"1eudbw7\" data-start=\"5377\" data-end=\"5389\"><strong data-start=\"5379\" data-end=\"5389\">Strips<\/strong><\/li>\n<li data-section-id=\"471ewi\" data-start=\"5390\" data-end=\"5404\"><strong data-start=\"5392\" data-end=\"5404\">Sections<\/strong><\/li>\n<li data-section-id=\"5iqh3e\" data-start=\"5405\" data-end=\"5415\"><strong data-start=\"5407\" data-end=\"5415\">Bars<\/strong><\/li>\n<\/ul>\n<p data-start=\"5417\" data-end=\"5538\">The BIS technical summary states that these products are rolled from cast material.<\/p>\n<p data-start=\"5540\" data-end=\"5783\">The Product Manual provides grouping guidance in <strong data-start=\"5589\" data-end=\"5600\">Annex A<\/strong>, meaning manufacturers intending to cover different product varieties must review the applicable grouping requirements before selecting samples.<\/p>\n<h1 data-section-id=\"a4cngt\" data-start=\"5785\" data-end=\"5843\">Is BIS Certification Mandatory for Fire Resistant Steel?<\/h1>\n<p data-start=\"5845\" data-end=\"5953\"><strong data-start=\"5845\" data-end=\"5953\">Yes. Fire Resistant Steel under IS 15103:2002 is included in the compulsory BIS certification framework.<\/strong><\/p>\n<p data-start=\"5955\" data-end=\"6037\">The <strong data-start=\"5959\" data-end=\"6017\">Steel and Steel Products (Quality Control) Order, 2024<\/strong> specifically lists:<\/p>\n<p data-start=\"6039\" data-end=\"6095\"><strong data-start=\"6039\" data-end=\"6095\">IS 15103:2002 \u2013 Fire resistant steel \u2013 Specification<\/strong><\/p>\n<p data-start=\"6097\" data-end=\"6111\">and specifies:<\/p>\n<p data-start=\"6113\" data-end=\"6181\"><strong data-start=\"6113\" data-end=\"6141\">\u201cWith immediate effect.\u201d<\/strong><\/p>\n<p data-start=\"6183\" data-end=\"6374\">The QCO lists a broad range of ITC (HS) codes for products covered by the standard, including codes covering relevant flat products, bars and sections.<\/p>\n<p data-start=\"6376\" data-end=\"6535\">Manufacturers should still check the latest QCO amendments, exemptions and government notifications applicable to their specific product and business category.<\/p>\n<h1 data-section-id=\"nou85t\" data-start=\"6537\" data-end=\"6585\">Steel and Steel Products Quality Control Order<\/h1>\n<p data-start=\"6587\" data-end=\"6682\">The Steel and Steel Products QCO is important for manufacturers producing fire resistant steel.<\/p>\n<p data-start=\"6684\" data-end=\"6817\">For IS 15103:2002, the order establishes compulsory conformity requirements and links the product to the BIS certification framework.<\/p>\n<p data-start=\"6819\" data-end=\"6961\">The current QCO specifically includes IS 15103:2002 and gives <strong data-start=\"6881\" data-end=\"6901\">immediate effect<\/strong> for implementation.<\/p>\n<p data-start=\"6963\" data-end=\"7144\">This means manufacturers supplying covered fire resistant steel products in India need to ensure the products comply with the applicable standard and BIS certification requirements.<\/p>\n<h1 data-section-id=\"c6n3z\" data-start=\"7146\" data-end=\"7190\">BIS Certification for Fire Resistant Steel<\/h1>\n<p data-start=\"7192\" data-end=\"7345\">BIS certification demonstrates that a manufacturer&#8217;s fire resistant steel product has been assessed against the applicable requirements of IS 15103:2002.<\/p>\n<p data-start=\"7347\" data-end=\"7518\">The BIS Product Manual states that certification is operated under <strong data-start=\"7414\" data-end=\"7477\">Scheme-I of the BIS Conformity Assessment Regulations, 2018<\/strong>.<\/p>\n<p data-start=\"7520\" data-end=\"7749\">After successful conformity assessment and grant of the BIS licence, the manufacturer can use the <strong data-start=\"7618\" data-end=\"7650\">BIS Standard Mark \/ ISI Mark<\/strong> on products covered by the approved licence scope and in accordance with BIS marking requirements.<\/p>\n<h1 data-section-id=\"y9qxft\" data-start=\"7751\" data-end=\"7806\">Who Needs BIS Certification for Fire Resistant Steel?<\/h1>\n<p data-start=\"7808\" data-end=\"7923\">BIS certification is relevant to manufacturers producing fire resistant steel products covered under IS 15103:2002.<\/p>\n<p data-start=\"7925\" data-end=\"7942\">This can include:<\/p>\n<ul data-start=\"7944\" data-end=\"8299\">\n<li data-section-id=\"hdv2em\" data-start=\"7944\" data-end=\"7980\">Fire Resistant Steel Manufacturers<\/li>\n<li data-section-id=\"4wld7e\" data-start=\"7981\" data-end=\"8013\">Structural Steel Manufacturers<\/li>\n<li data-section-id=\"1jzrhgr\" data-start=\"8014\" data-end=\"8041\">Steel Plate Manufacturers<\/li>\n<li data-section-id=\"1vzow97\" data-start=\"8042\" data-end=\"8069\">Steel Strip Manufacturers<\/li>\n<li data-section-id=\"1rtvay6\" data-start=\"8070\" data-end=\"8099\">Steel Section Manufacturers<\/li>\n<li data-section-id=\"wpims6\" data-start=\"8100\" data-end=\"8125\">Steel Bar Manufacturers<\/li>\n<li data-section-id=\"186g85v\" data-start=\"8126\" data-end=\"8161\">Special Grade Steel Manufacturers<\/li>\n<li data-section-id=\"wpb6vy\" data-start=\"8162\" data-end=\"8198\">Structural Component Manufacturers<\/li>\n<li data-section-id=\"107vnwp\" data-start=\"8199\" data-end=\"8220\">Steel Rolling Mills<\/li>\n<li data-section-id=\"1o9sp4u\" data-start=\"8221\" data-end=\"8254\">Engineering Steel Manufacturers<\/li>\n<li data-section-id=\"18qs2tn\" data-start=\"8255\" data-end=\"8274\">OEM Manufacturers<\/li>\n<li data-section-id=\"enlnku\" data-start=\"8275\" data-end=\"8299\">Contract Manufacturers<\/li>\n<\/ul>\n<p data-start=\"8301\" data-end=\"8424\">Importers and businesses supplying covered steel products should separately verify their obligations under the current QCO.<\/p>\n<h1 data-section-id=\"1sebo4n\" data-start=\"8426\" data-end=\"8470\">BIS Certification Eligibility Requirements<\/h1>\n<p data-start=\"8472\" data-end=\"8598\">A manufacturer seeking BIS certification should generally have appropriate production, testing and quality-control facilities.<\/p>\n<p data-start=\"8600\" data-end=\"8618\">These may include:<\/p>\n<ul data-start=\"8620\" data-end=\"9160\">\n<li data-section-id=\"1jol42u\" data-start=\"8620\" data-end=\"8673\">Steelmaking or suitable steel-processing facilities<\/li>\n<li data-section-id=\"c1otn2\" data-start=\"8674\" data-end=\"8694\">Casting facilities<\/li>\n<li data-section-id=\"11iaufq\" data-start=\"8695\" data-end=\"8715\">Rolling facilities<\/li>\n<li data-section-id=\"ajx50z\" data-start=\"8716\" data-end=\"8746\">Product finishing facilities<\/li>\n<li data-section-id=\"tiqty\" data-start=\"8747\" data-end=\"8792\">Heat-treatment facilities, where applicable<\/li>\n<li data-section-id=\"qx98gv\" data-start=\"8793\" data-end=\"8823\">Cutting and sizing equipment<\/li>\n<li data-section-id=\"p1igq8\" data-start=\"8824\" data-end=\"8854\">Chemical-analysis laboratory<\/li>\n<li data-section-id=\"mmhkpn\" data-start=\"8855\" data-end=\"8886\">Mechanical-testing facilities<\/li>\n<li data-section-id=\"105sto5\" data-start=\"8887\" data-end=\"8930\">High-temperature tensile-testing facility<\/li>\n<li data-section-id=\"1hhk463\" data-start=\"8931\" data-end=\"8954\">Bend-testing facility<\/li>\n<li data-section-id=\"1rzzc1g\" data-start=\"8955\" data-end=\"8980\">Impact-testing facility<\/li>\n<li data-section-id=\"sbkotd\" data-start=\"8981\" data-end=\"9015\">Dimensional inspection equipment<\/li>\n<li data-section-id=\"kpeh8n\" data-start=\"9016\" data-end=\"9036\">Calibration system<\/li>\n<li data-section-id=\"y8f4bh\" data-start=\"9037\" data-end=\"9064\">Quality-control personnel<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"9065\" data-end=\"9085\">Production records<\/li>\n<li data-section-id=\"x92i00\" data-start=\"9086\" data-end=\"9100\">Test records<\/li>\n<li data-section-id=\"1eaj5fd\" data-start=\"9101\" data-end=\"9125\">Heat\/cast traceability<\/li>\n<li data-section-id=\"z87z2a\" data-start=\"9126\" data-end=\"9160\">Marking and packing arrangements<\/li>\n<\/ul>\n<p data-start=\"9162\" data-end=\"9254\">The exact requirements depend on the product grade, product form and proposed licence scope.<\/p>\n<h1 data-section-id=\"zpea0k\" data-start=\"9256\" data-end=\"9308\">BIS Certification Process for Fire Resistant Steel<\/h1>\n<h2 data-section-id=\"110du8d\" data-start=\"9310\" data-end=\"9354\">Step 1 \u2013 Product Applicability Assessment<\/h2>\n<p data-start=\"9356\" data-end=\"9421\">The manufacturer&#8217;s product is assessed against <strong data-start=\"9403\" data-end=\"9420\">IS 15103:2002<\/strong>.<\/p>\n<p data-start=\"9423\" data-end=\"9443\">The review includes:<\/p>\n<ul data-start=\"9445\" data-end=\"9548\">\n<li data-section-id=\"1sta8lx\" data-start=\"9445\" data-end=\"9459\">Product form<\/li>\n<li data-section-id=\"170hry5\" data-start=\"9460\" data-end=\"9467\">Grade<\/li>\n<li data-section-id=\"1j4dcvh\" data-start=\"9468\" data-end=\"9474\">Size<\/li>\n<li data-section-id=\"1tgvbw1\" data-start=\"9475\" data-end=\"9496\">Manufacturing route<\/li>\n<li data-section-id=\"dmf8i7\" data-start=\"9497\" data-end=\"9519\">Intended application<\/li>\n<li data-section-id=\"1opo375\" data-start=\"9520\" data-end=\"9548\">Proposed BIS licence scope<\/li>\n<\/ul>\n<h2 data-section-id=\"jinnu1\" data-start=\"9550\" data-end=\"9582\">Step 2 \u2013 Grade Identification<\/h2>\n<p data-start=\"9584\" data-end=\"9635\">The manufacturer determines whether the product is:<\/p>\n<p data-start=\"9637\" data-end=\"9660\"><strong data-start=\"9637\" data-end=\"9660\">FR-Fe 410 \u2013 Grade A<\/strong><\/p>\n<p data-start=\"9662\" data-end=\"9664\">or<\/p>\n<p data-start=\"9666\" data-end=\"9690\"><strong data-start=\"9666\" data-end=\"9689\">FR-Fe 490 \u2013 Grade B<\/strong>.<\/p>\n<h2 data-section-id=\"wuqsdf\" data-start=\"9692\" data-end=\"9720\">Step 3 \u2013 Product Grouping<\/h2>\n<p data-start=\"9722\" data-end=\"9853\">Grouping is reviewed according to the BIS Product Manual and applicable Annex A provisions.<\/p>\n<h2 data-section-id=\"oghbx7\" data-start=\"9855\" data-end=\"9892\">Step 4 \u2013 Documentation Preparation<\/h2>\n<p data-start=\"9894\" data-end=\"9962\">Technical, manufacturing and quality-control documents are prepared.<\/p>\n<h2 data-section-id=\"35v9se\" data-start=\"9964\" data-end=\"9994\">Step 5 \u2013 Sample Preparation<\/h2>\n<p data-start=\"9996\" data-end=\"10029\">The BIS Product Manual specifies:<\/p>\n<p data-start=\"10031\" data-end=\"10066\"><strong data-start=\"10031\" data-end=\"10058\">Mechanical test sample:<\/strong> 1 metre<\/p>\n<p data-start=\"10068\" data-end=\"10164\"><strong data-start=\"10068\" data-end=\"10093\">Chemical test sample:<\/strong> 5 pieces of <strong data-start=\"10106\" data-end=\"10123\">50 mm \u00d7 50 mm<\/strong>.<\/p>\n<p data-start=\"10166\" data-end=\"10283\">Representative samples should be selected according to the proposed licence scope and applicable grouping provisions.<\/p>\n<h2 data-section-id=\"17jzkbr\" data-start=\"10285\" data-end=\"10315\">Step 6 \u2013 Laboratory Testing<\/h2>\n<p data-start=\"10317\" data-end=\"10389\">Samples are tested against the applicable requirements of IS 15103:2002.<\/p>\n<h2 data-section-id=\"mi4tjl\" data-start=\"10391\" data-end=\"10418\">Step 7 \u2013 BIS Application<\/h2>\n<p data-start=\"10420\" data-end=\"10525\">The manufacturer submits the BIS application along with the required technical and factory documentation.<\/p>\n<h2 data-section-id=\"83pfi6\" data-start=\"10527\" data-end=\"10557\">Step 8 \u2013 Factory Assessment<\/h2>\n<p data-start=\"10559\" data-end=\"10667\">BIS assesses the manufacturing facility, testing laboratory, production controls and quality-control system.<\/p>\n<h2 data-section-id=\"itk4y6\" data-start=\"10669\" data-end=\"10700\">Step 9 \u2013 Observation Closure<\/h2>\n<p data-start=\"10702\" data-end=\"10815\">Any observations identified during the assessment are addressed through corrective action and supporting records.<\/p>\n<h2 data-section-id=\"r57vg8\" data-start=\"10817\" data-end=\"10847\">Step 10 \u2013 BIS Licence Grant<\/h2>\n<p data-start=\"10849\" data-end=\"10935\">After successful conformity assessment, BIS grants the licence for the approved scope.<\/p>\n<h2 data-section-id=\"1keafvm\" data-start=\"10937\" data-end=\"10961\">Step 11 \u2013 ISI Marking<\/h2>\n<p data-start=\"10963\" data-end=\"11092\">The manufacturer can apply the BIS Standard Mark to products covered by the licence according to applicable marking requirements.<\/p>\n<h1 data-section-id=\"12o6q79\" data-start=\"11094\" data-end=\"11141\">Testing Requirements for Fire Resistant Steel<\/h1>\n<p data-start=\"11143\" data-end=\"11209\">Testing is a critical part of BIS certification for IS 15103:2002.<\/p>\n<p data-start=\"11211\" data-end=\"11274\">BIS&#8217;s official technical summary identifies the major tests as:<\/p>\n<ul data-start=\"11276\" data-end=\"11468\">\n<li data-section-id=\"fpgw2b\" data-start=\"11276\" data-end=\"11313\">Tensile test at ambient temperature<\/li>\n<li data-section-id=\"1wwgifd\" data-start=\"11314\" data-end=\"11361\">Tensile test at elevated temperature of 600\u00b0C<\/li>\n<li data-section-id=\"4caeur\" data-start=\"11362\" data-end=\"11373\">Bend test<\/li>\n<li data-section-id=\"o1l5ek\" data-start=\"11374\" data-end=\"11387\">Impact test<\/li>\n<li data-section-id=\"1g7qg16\" data-start=\"11388\" data-end=\"11410\">Freedom from defects<\/li>\n<li data-section-id=\"1j3zlok\" data-start=\"11411\" data-end=\"11417\">Mass<\/li>\n<li data-section-id=\"1f5i8ey\" data-start=\"11418\" data-end=\"11445\">Dimensions and tolerances<\/li>\n<li data-section-id=\"v16bzo\" data-start=\"11446\" data-end=\"11468\">Chemical composition<\/li>\n<\/ul>\n<p data-start=\"11470\" data-end=\"11509\">\n<h1 data-section-id=\"46iqze\" data-start=\"11511\" data-end=\"11533\">Chemical Composition<\/h1>\n<p data-start=\"11535\" data-end=\"11623\">Chemical composition is one of the most important requirements for fire resistant steel.<\/p>\n<p data-start=\"11625\" data-end=\"11795\">The BIS technical summary explains that IS 15103 specifies both <strong data-start=\"11689\" data-end=\"11728\">ladle analysis and product analysis<\/strong> for the chemical composition. It identifies controlled limits for:<\/p>\n<ul data-start=\"11797\" data-end=\"11874\">\n<li data-section-id=\"1uyczyz\" data-start=\"11797\" data-end=\"11805\">Carbon<\/li>\n<li data-section-id=\"1nus0t1\" data-start=\"11806\" data-end=\"11815\">Silicon<\/li>\n<li data-section-id=\"t8y5ox\" data-start=\"11816\" data-end=\"11827\">Manganese<\/li>\n<li data-section-id=\"1kt0a2l\" data-start=\"11828\" data-end=\"11837\">Sulphur<\/li>\n<li data-section-id=\"1uyh4rz\" data-start=\"11838\" data-end=\"11850\">Phosphorus<\/li>\n<li data-section-id=\"aooen6\" data-start=\"11851\" data-end=\"11861\">Chromium<\/li>\n<li data-section-id=\"l1ga7e\" data-start=\"11862\" data-end=\"11874\">Molybdenum<\/li>\n<\/ul>\n<p data-start=\"11876\" data-end=\"12039\">These controlled alloying elements help provide the required fire-resistant properties together with necessary weldability.<\/p>\n<p data-start=\"12041\" data-end=\"12217\">The current BIS LIMS testing entry also identifies separate testing charges for these chemical elements under Clauses 6 and 7.1\/Table 1.<\/p>\n<h1 data-section-id=\"6su3it\" data-start=\"12219\" data-end=\"12227\">Carbon<\/h1>\n<p data-start=\"12229\" data-end=\"12269\">Carbon is controlled because it affects:<\/p>\n<ul data-start=\"12271\" data-end=\"12335\">\n<li data-section-id=\"1e9sf8t\" data-start=\"12271\" data-end=\"12281\">Strength<\/li>\n<li data-section-id=\"1rhmjlo\" data-start=\"12282\" data-end=\"12292\">Hardness<\/li>\n<li data-section-id=\"8bckeo\" data-start=\"12293\" data-end=\"12306\">Weldability<\/li>\n<li data-section-id=\"amobpa\" data-start=\"12307\" data-end=\"12335\">High-temperature behaviour<\/li>\n<\/ul>\n<p data-start=\"12337\" data-end=\"12395\">The applicable carbon limit depends on the selected grade.<\/p>\n<h1 data-section-id=\"2lfd3v\" data-start=\"12397\" data-end=\"12406\">Silicon<\/h1>\n<p data-start=\"12408\" data-end=\"12506\">Silicon contributes to steel deoxidation and influences the material&#8217;s mechanical characteristics.<\/p>\n<p data-start=\"12508\" data-end=\"12568\">Its content is controlled according to the applicable grade.<\/p>\n<h1 data-section-id=\"skc4f3\" data-start=\"12570\" data-end=\"12581\">Manganese<\/h1>\n<p data-start=\"12583\" data-end=\"12698\">Manganese contributes to strength and metallurgical performance, but must be maintained within the specified range.<\/p>\n<h1 data-section-id=\"11i8yxr\" data-start=\"12700\" data-end=\"12724\">Sulphur and Phosphorus<\/h1>\n<p data-start=\"12726\" data-end=\"12849\">Sulphur and phosphorus are controlled because excessive levels can affect toughness, weldability and overall steel quality.<\/p>\n<h1 data-section-id=\"nm2okl\" data-start=\"12851\" data-end=\"12876\">Chromium and Molybdenum<\/h1>\n<p data-start=\"12878\" data-end=\"12989\">Chromium and molybdenum are particularly important to the fire-resistant characteristics of this type of steel.<\/p>\n<p data-start=\"12991\" data-end=\"13178\">BIS specifically states that fire resistance is achieved through controlled incorporation of alloying elements such as <strong data-start=\"13110\" data-end=\"13137\">chromium and molybdenum<\/strong>.<\/p>\n<h1 data-section-id=\"1tzx9h9\" data-start=\"13180\" data-end=\"13217\">Tensile Test at Ambient Temperature<\/h1>\n<p data-start=\"13219\" data-end=\"13328\">Ambient-temperature tensile testing evaluates the mechanical properties of the steel under normal conditions.<\/p>\n<p data-start=\"13330\" data-end=\"13359\">Important properties include:<\/p>\n<ul data-start=\"13361\" data-end=\"13420\">\n<li data-section-id=\"1j94mjl\" data-start=\"13361\" data-end=\"13379\">Tensile strength<\/li>\n<li data-section-id=\"1r26z8w\" data-start=\"13380\" data-end=\"13396\">Yield strength<\/li>\n<li data-section-id=\"y2jqxu\" data-start=\"13397\" data-end=\"13420\">Percentage elongation<\/li>\n<\/ul>\n<p data-start=\"13422\" data-end=\"13564\">The BIS technical summary specifically identifies these requirements under the tensile test procedure.<\/p>\n<h1 data-section-id=\"bbtkx8\" data-start=\"13566\" data-end=\"13589\">Tensile Test at 600\u00b0C<\/h1>\n<p data-start=\"13591\" data-end=\"13693\">One of the most important distinguishing features of IS 15103 is elevated-temperature tensile testing.<\/p>\n<p data-start=\"13695\" data-end=\"13728\">The standard requires testing at:<\/p>\n<p data-start=\"13730\" data-end=\"13739\"><strong data-start=\"13730\" data-end=\"13739\">600\u00b0C<\/strong><\/p>\n<p data-start=\"13741\" data-end=\"13860\">The purpose is to determine whether the steel maintains the specified strength characteristics at elevated temperature.<\/p>\n<p data-start=\"13862\" data-end=\"14084\">The BIS technical summary confirms that both tensile strength, yield strength and percentage elongation requirements are evaluated in the relevant high-temperature testing framework.<\/p>\n<p data-start=\"14086\" data-end=\"14231\">The standard also includes a detailed procedure for elevated-temperature tensile testing in its annexure.<\/p>\n<h1 data-section-id=\"e6l0nx\" data-start=\"14233\" data-end=\"14244\">Bend Test<\/h1>\n<p data-start=\"14246\" data-end=\"14319\">The bend test evaluates the ductility and bending behaviour of the steel.<\/p>\n<p data-start=\"14321\" data-end=\"14523\">BIS specifies that the sample is doubled over with an internal diameter of approximately <strong data-start=\"14410\" data-end=\"14449\">2 to 3 times the specimen thickness<\/strong>, and the sample should not crack.<\/p>\n<p data-start=\"14525\" data-end=\"14663\">The current BIS LIMS entry identifies <strong data-start=\"14563\" data-end=\"14588\">Clause 11 \u2013 Bend Test<\/strong> as a specific testing requirement.<\/p>\n<h1 data-section-id=\"gdgeia\" data-start=\"14665\" data-end=\"14678\">Impact Test<\/h1>\n<p data-start=\"14680\" data-end=\"14732\">Impact performance is also an important requirement.<\/p>\n<p data-start=\"14734\" data-end=\"14807\">The BIS technical summary states that the absorbed impact energy must be:<\/p>\n<p data-start=\"14809\" data-end=\"14884\"><strong data-start=\"14809\" data-end=\"14844\">Not less than 27 joules at 0\u00b0C.<\/strong><\/p>\n<p data-start=\"14886\" data-end=\"14985\">Impact testing helps evaluate the toughness of the steel under the specified temperature condition.<\/p>\n<h1 data-section-id=\"axmbes\" data-start=\"14987\" data-end=\"15009\">Freedom from Defects<\/h1>\n<p data-start=\"15011\" data-end=\"15068\">The steel must be free from unacceptable defects such as:<\/p>\n<ul data-start=\"15070\" data-end=\"15149\">\n<li data-section-id=\"1v9yjkz\" data-start=\"15070\" data-end=\"15078\">Cracks<\/li>\n<li data-section-id=\"r35fyq\" data-start=\"15079\" data-end=\"15094\">Surface flaws<\/li>\n<li data-section-id=\"1efam75\" data-start=\"15095\" data-end=\"15108\">Laminations<\/li>\n<li data-section-id=\"188upl2\" data-start=\"15109\" data-end=\"15149\">Other defects affecting serviceability<\/li>\n<\/ul>\n<p data-start=\"15151\" data-end=\"15300\">BIS&#8217;s technical summary specifically identifies freedom from defects as one of the required inspection areas.<\/p>\n<p data-start=\"15302\" data-end=\"15449\">The current BIS LIMS listing also identifies <strong data-start=\"15347\" data-end=\"15383\">Clause 13 \u2013 Freedom from Defects<\/strong> as a testing requirement.<\/p>\n<h1 data-section-id=\"14soil0\" data-start=\"15451\" data-end=\"15484\">Mass, Dimensions and Tolerances<\/h1>\n<p data-start=\"15486\" data-end=\"15561\">The finished products must comply with applicable dimensional requirements.<\/p>\n<p data-start=\"15563\" data-end=\"15590\">This includes the relevant:<\/p>\n<ul data-start=\"15592\" data-end=\"15669\">\n<li data-section-id=\"1kfygu\" data-start=\"15592\" data-end=\"15603\">Thickness<\/li>\n<li data-section-id=\"17b94zy\" data-start=\"15604\" data-end=\"15611\">Width<\/li>\n<li data-section-id=\"1p7clhw\" data-start=\"15612\" data-end=\"15620\">Length<\/li>\n<li data-section-id=\"uw7qsc\" data-start=\"15621\" data-end=\"15649\">Cross-sectional dimensions<\/li>\n<li data-section-id=\"1j3zlok\" data-start=\"15650\" data-end=\"15656\">Mass<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"15657\" data-end=\"15669\">Tolerances<\/li>\n<\/ul>\n<p data-start=\"15671\" data-end=\"15761\">The exact dimensional requirements depend on the form of the fire resistant steel product.<\/p>\n<h1 data-section-id=\"1ueixno\" data-start=\"15763\" data-end=\"15786\">Product Forms Covered<\/h1>\n<p data-start=\"15788\" data-end=\"15809\">IS 15103:2002 covers:<\/p>\n<h3 data-section-id=\"tj2ttl\" data-start=\"15811\" data-end=\"15821\">Plates<\/h3>\n<p data-start=\"15823\" data-end=\"15859\">Flat rolled structural steel plates.<\/p>\n<h3 data-section-id=\"onn7x5\" data-start=\"15861\" data-end=\"15871\">Strips<\/h3>\n<p data-start=\"15873\" data-end=\"15940\">Steel strips manufactured according to the applicable requirements.<\/p>\n<h3 data-section-id=\"1vxk2sc\" data-start=\"15942\" data-end=\"15954\">Sections<\/h3>\n<p data-start=\"15956\" data-end=\"16027\">Structural sections used for construction and engineering applications.<\/p>\n<h3 data-section-id=\"ynd0x0\" data-start=\"16029\" data-end=\"16037\">Bars<\/h3>\n<p data-start=\"16039\" data-end=\"16115\">Steel bars suitable for structural applications within the standard&#8217;s scope.<\/p>\n<p data-start=\"16117\" data-end=\"16217\">The BIS technical summary identifies all four product forms.<\/p>\n<h1 data-section-id=\"1agk8md\" data-start=\"16219\" data-end=\"16246\">Raw Material Requirements<\/h1>\n<p data-start=\"16248\" data-end=\"16278\">The BIS Product Manual states:<\/p>\n<p data-start=\"16280\" data-end=\"16362\"><strong data-start=\"16280\" data-end=\"16322\">Raw Material: No specific requirement.<\/strong><\/p>\n<p data-start=\"16364\" data-end=\"16518\">However, manufacturers must ensure that their production route can consistently achieve the chemical and mechanical properties specified by IS 15103:2002.<\/p>\n<p data-start=\"16520\" data-end=\"16575\">Manufacturers should maintain appropriate control over:<\/p>\n<ul data-start=\"16577\" data-end=\"16732\">\n<li data-section-id=\"19bnmyf\" data-start=\"16577\" data-end=\"16598\">Raw-material source<\/li>\n<li data-section-id=\"hdxszd\" data-start=\"16599\" data-end=\"16617\">Heat\/cast number<\/li>\n<li data-section-id=\"zib2zp\" data-start=\"16618\" data-end=\"16641\">Material certificates<\/li>\n<li data-section-id=\"6a59z6\" data-start=\"16642\" data-end=\"16670\">Input chemical composition<\/li>\n<li data-section-id=\"17dpedi\" data-start=\"16671\" data-end=\"16688\">Melting records<\/li>\n<li data-section-id=\"5wej2r\" data-start=\"16689\" data-end=\"16706\">Casting records<\/li>\n<li data-section-id=\"1hrhnu0\" data-start=\"16707\" data-end=\"16732\">Production traceability<\/li>\n<\/ul>\n<h1 data-section-id=\"1uzred0\" data-start=\"16734\" data-end=\"16782\">Manufacturing Process for Fire Resistant Steel<\/h1>\n<p data-start=\"16784\" data-end=\"16828\">A typical manufacturing process may include:<\/p>\n<ol data-start=\"16830\" data-end=\"17284\">\n<li data-section-id=\"1xjq2ox\" data-start=\"16830\" data-end=\"16857\">Raw-material preparation<\/li>\n<li data-section-id=\"l8ug5l\" data-start=\"16858\" data-end=\"16868\">Melting<\/li>\n<li data-section-id=\"jyh2vf\" data-start=\"16869\" data-end=\"16903\">Chemical composition adjustment<\/li>\n<li data-section-id=\"19jvl49\" data-start=\"16904\" data-end=\"16915\">Refining<\/li>\n<li data-section-id=\"urhato\" data-start=\"16916\" data-end=\"16933\">Ladle analysis<\/li>\n<li data-section-id=\"12jonko\" data-start=\"16934\" data-end=\"16944\">Casting<\/li>\n<li data-section-id=\"i5ld70\" data-start=\"16945\" data-end=\"16971\">Billet\/slab preparation<\/li>\n<li data-section-id=\"9xjj5o\" data-start=\"16972\" data-end=\"16984\">Reheating<\/li>\n<li data-section-id=\"hh49wv\" data-start=\"16985\" data-end=\"16995\">Rolling<\/li>\n<li data-section-id=\"17ptxgj\" data-start=\"16996\" data-end=\"17036\">Controlled cooling, where applicable<\/li>\n<li data-section-id=\"6uuwu5\" data-start=\"17037\" data-end=\"17048\">Cutting<\/li>\n<li data-section-id=\"1wpgwhn\" data-start=\"17049\" data-end=\"17062\">Finishing<\/li>\n<li data-section-id=\"43ndqi\" data-start=\"17063\" data-end=\"17089\">Dimensional inspection<\/li>\n<li data-section-id=\"dbowzc\" data-start=\"17090\" data-end=\"17111\">Chemical analysis<\/li>\n<li data-section-id=\"1mt9nxp\" data-start=\"17112\" data-end=\"17139\">Ambient tensile testing<\/li>\n<li data-section-id=\"hwo3ax\" data-start=\"17140\" data-end=\"17180\">Elevated-temperature tensile testing<\/li>\n<li data-section-id=\"156jmd2\" data-start=\"17181\" data-end=\"17197\">Bend testing<\/li>\n<li data-section-id=\"gibyly\" data-start=\"17198\" data-end=\"17216\">Impact testing<\/li>\n<li data-section-id=\"1a3vp60\" data-start=\"17217\" data-end=\"17239\">Surface inspection<\/li>\n<li data-section-id=\"1m9wlrv\" data-start=\"17240\" data-end=\"17260\">Final inspection<\/li>\n<li data-section-id=\"13fbjpt\" data-start=\"17261\" data-end=\"17272\">Packing<\/li>\n<li data-section-id=\"1nk6lz2\" data-start=\"17273\" data-end=\"17284\">Marking<\/li>\n<\/ol>\n<p data-start=\"17286\" data-end=\"17375\">The actual manufacturing route depends on the product form and manufacturer&#8217;s technology.<\/p>\n<h1 data-section-id=\"19cisod\" data-start=\"17377\" data-end=\"17426\">BIS Factory Inspection for Fire Resistant Steel<\/h1>\n<p data-start=\"17428\" data-end=\"17489\">Factory assessment is an important part of BIS certification.<\/p>\n<p data-start=\"17491\" data-end=\"17525\">During inspection, BIS may assess:<\/p>\n<h3 data-section-id=\"1wm5k84\" data-start=\"17527\" data-end=\"17554\">Steelmaking and Casting<\/h3>\n<p data-start=\"17556\" data-end=\"17672\">Where the manufacturer controls melting and casting, relevant process and traceability arrangements may be examined.<\/p>\n<h3 data-section-id=\"1jymf88\" data-start=\"17674\" data-end=\"17696\">Rolling Facilities<\/h3>\n<p data-start=\"17698\" data-end=\"17761\">Equipment used to manufacture plates, strips, sections or bars.<\/p>\n<h3 data-section-id=\"11lslmi\" data-start=\"17763\" data-end=\"17791\">Heat Treatment \/ Cooling<\/h3>\n<p data-start=\"17793\" data-end=\"17833\">Applicable process-control arrangements.<\/p>\n<h3 data-section-id=\"f8uig1\" data-start=\"17835\" data-end=\"17858\">Chemical Laboratory<\/h3>\n<p data-start=\"17860\" data-end=\"17911\">Facilities for ladle and product chemical analysis.<\/p>\n<h3 data-section-id=\"1dnva1o\" data-start=\"17913\" data-end=\"17932\">Tensile Testing<\/h3>\n<p data-start=\"17934\" data-end=\"18015\">Standard tensile testing equipment for ambient-temperature mechanical properties.<\/p>\n<h3 data-section-id=\"1peopw3\" data-start=\"18017\" data-end=\"18053\">High-Temperature Tensile Testing<\/h3>\n<p data-start=\"18055\" data-end=\"18119\">Suitable facilities for testing tensile properties at <strong data-start=\"18109\" data-end=\"18118\">600\u00b0C<\/strong>.<\/p>\n<h3 data-section-id=\"movvy5\" data-start=\"18121\" data-end=\"18137\">Bend Testing<\/h3>\n<p data-start=\"18139\" data-end=\"18200\">Suitable equipment for carrying out the applicable bend test.<\/p>\n<h3 data-section-id=\"qrgg6q\" data-start=\"18202\" data-end=\"18220\">Impact Testing<\/h3>\n<p data-start=\"18222\" data-end=\"18298\">Suitable impact-testing equipment for the specified temperature requirement.<\/p>\n<h3 data-section-id=\"1if4tad\" data-start=\"18300\" data-end=\"18326\">Dimensional Inspection<\/h3>\n<p data-start=\"18328\" data-end=\"18373\">Appropriate gauges and measuring instruments.<\/p>\n<h3 data-section-id=\"wzkpnw\" data-start=\"18375\" data-end=\"18390\">Calibration<\/h3>\n<p data-start=\"18392\" data-end=\"18475\">The manufacturer should maintain a suitable calibration plan for testing equipment.<\/p>\n<h3 data-section-id=\"1oz01yd\" data-start=\"18477\" data-end=\"18493\">Traceability<\/h3>\n<p data-start=\"18495\" data-end=\"18549\">Heat and production traceability should be maintained.<\/p>\n<h3 data-section-id=\"1kypjpx\" data-start=\"18551\" data-end=\"18570\">Quality Records<\/h3>\n<p data-start=\"18572\" data-end=\"18638\">Production and testing records should be available for assessment.<\/p>\n<h1 data-section-id=\"1i6id4n\" data-start=\"18640\" data-end=\"18677\">Testing Equipment for IS 15103:2002<\/h1>\n<p data-start=\"18679\" data-end=\"18832\">The current BIS Product Manual specifies that applicants should refer to <strong data-start=\"18752\" data-end=\"18763\">Annex B<\/strong> for the test-equipment list.<\/p>\n<p data-start=\"18834\" data-end=\"18889\">Depending on the testing scope, facilities may include:<\/p>\n<ul data-start=\"18891\" data-end=\"19209\">\n<li data-section-id=\"6p76ty\" data-start=\"18891\" data-end=\"18918\">Universal Testing Machine<\/li>\n<li data-section-id=\"1peotfy\" data-start=\"18919\" data-end=\"18965\">High-temperature tensile-testing arrangement<\/li>\n<li data-section-id=\"1skyzg4\" data-start=\"18966\" data-end=\"19023\">Furnace capable of maintaining the required temperature<\/li>\n<li data-section-id=\"14utm8w\" data-start=\"19024\" data-end=\"19050\">Bend-testing arrangement<\/li>\n<li data-section-id=\"1m7yfg4\" data-start=\"19051\" data-end=\"19075\">Impact-testing machine<\/li>\n<li data-section-id=\"rf2v2x\" data-start=\"19076\" data-end=\"19105\">Chemical-analysis equipment<\/li>\n<li data-section-id=\"a7bdfu\" data-start=\"19106\" data-end=\"19124\">Vernier calipers<\/li>\n<li data-section-id=\"ihgwve\" data-start=\"19125\" data-end=\"19138\">Micrometers<\/li>\n<li data-section-id=\"1ubu7tq\" data-start=\"19139\" data-end=\"19157\">Measuring scales<\/li>\n<li data-section-id=\"swlxpz\" data-start=\"19158\" data-end=\"19178\">Dimensional gauges<\/li>\n<li data-section-id=\"niejyc\" data-start=\"19179\" data-end=\"19209\">Surface-inspection equipment<\/li>\n<\/ul>\n<p data-start=\"19211\" data-end=\"19328\">The exact equipment requirement should be established from the current BIS Product Manual and proposed licence scope.<\/p>\n<h1 data-section-id=\"1hwcyhr\" data-start=\"19330\" data-end=\"19366\">Product Grouping for IS 15103:2002<\/h1>\n<p data-start=\"19368\" data-end=\"19470\">Product grouping is important where a manufacturer produces more than one grade, size or product form.<\/p>\n<p data-start=\"19472\" data-end=\"19515\">The BIS Product Manual specifically states:<\/p>\n<p data-start=\"19517\" data-end=\"19603\"><strong data-start=\"19517\" data-end=\"19563\">Grouping Guidelines: Please refer Annex A.<\/strong><\/p>\n<p data-start=\"19605\" data-end=\"19707\">This means the manufacturer should review the applicable grouping provisions before selecting samples.<\/p>\n<p data-start=\"19709\" data-end=\"19744\">Proper grouping can help determine:<\/p>\n<ul data-start=\"19746\" data-end=\"19914\">\n<li data-section-id=\"35y0xo\" data-start=\"19746\" data-end=\"19788\">Which grades need representative testing<\/li>\n<li data-section-id=\"fum8gg\" data-start=\"19789\" data-end=\"19818\">Which sizes can be included<\/li>\n<li data-section-id=\"1qr7ayk\" data-start=\"19819\" data-end=\"19855\">Which product forms can be covered<\/li>\n<li data-section-id=\"1wcueny\" data-start=\"19856\" data-end=\"19914\">Which sample should represent the proposed licence scope<\/li>\n<\/ul>\n<p data-start=\"19916\" data-end=\"20014\">The final licence scope also depends on the manufacturer&#8217;s manufacturing and testing capabilities.<\/p>\n<h1 data-section-id=\"1azfpmh\" data-start=\"20016\" data-end=\"20050\">Scheme of Inspection and Testing<\/h1>\n<p data-start=\"20052\" data-end=\"20177\">The BIS Product Manual provides a Scheme of Inspection and Testing under <strong data-start=\"20125\" data-end=\"20136\">Annex C<\/strong>.<\/p>\n<p data-start=\"20179\" data-end=\"20212\">The manufacturer should maintain:<\/p>\n<ul data-start=\"20214\" data-end=\"20404\">\n<li data-section-id=\"1rbtq55\" data-start=\"20214\" data-end=\"20246\">Suitable laboratory facilities<\/li>\n<li data-section-id=\"lxtaoh\" data-start=\"20247\" data-end=\"20265\">Calibration plan<\/li>\n<li data-section-id=\"1uczpwg\" data-start=\"20266\" data-end=\"20286\">Testing procedures<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"20287\" data-end=\"20307\">Inspection records<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"20308\" data-end=\"20328\">Production records<\/li>\n<li data-section-id=\"zc0p3f\" data-start=\"20329\" data-end=\"20343\">Traceability<\/li>\n<li data-section-id=\"1u5wq3l\" data-start=\"20344\" data-end=\"20377\">Non-conforming product controls<\/li>\n<li data-section-id=\"389kmg\" data-start=\"20378\" data-end=\"20404\">BIS marking arrangements<\/li>\n<\/ul>\n<p data-start=\"20406\" data-end=\"20586\">Because fire resistant steel performance depends heavily on chemical composition and elevated-temperature mechanical properties, consistent batch control is particularly important.<\/p>\n<h1 data-section-id=\"1o74h5k\" data-start=\"20588\" data-end=\"20634\">BIS Testing Charges for Fire Resistant Steel<\/h1>\n<p data-start=\"20636\" data-end=\"20708\">Current BIS LIMS information provides testing charges for IS 15103:2002.<\/p>\n<p data-start=\"20710\" data-end=\"20794\">A current entry from the <strong data-start=\"20735\" data-end=\"20787\">National Institute of Secondary Steel Technology<\/strong> lists:<\/p>\n<p data-start=\"20796\" data-end=\"20823\"><strong data-start=\"20796\" data-end=\"20823\">\u20b911,500 excluding taxes<\/strong><\/p>\n<p data-start=\"20825\" data-end=\"20947\">for <strong data-start=\"20829\" data-end=\"20875\">all grades, all sizes and all designations<\/strong> under the listed testing scope.<\/p>\n<p data-start=\"20949\" data-end=\"21007\">The same listing provides individual test charges such as:<\/p>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"21009\" data-end=\"21351\">\n<thead data-start=\"21009\" data-end=\"21033\">\n<tr data-start=\"21009\" data-end=\"21033\">\n<th class=\"last:pe-10\" data-start=\"21009\" data-end=\"21016\" data-col-size=\"sm\">Test<\/th>\n<th class=\"last:pe-10\" data-start=\"21016\" data-end=\"21033\" data-col-size=\"sm\">Listed Charge<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"21045\" data-end=\"21351\">\n<tr data-start=\"21045\" data-end=\"21082\">\n<td data-start=\"21045\" data-end=\"21072\" data-col-size=\"sm\">Tensile Test \u2013 Clause 10<\/td>\n<td data-start=\"21072\" data-end=\"21082\" data-col-size=\"sm\">\u20b91,500<\/td>\n<\/tr>\n<tr data-start=\"21083\" data-end=\"21115\">\n<td data-start=\"21083\" data-end=\"21107\" data-col-size=\"sm\">Bend Test \u2013 Clause 11<\/td>\n<td data-start=\"21107\" data-end=\"21115\" data-col-size=\"sm\">\u20b9500<\/td>\n<\/tr>\n<tr data-start=\"21116\" data-end=\"21152\">\n<td data-start=\"21116\" data-end=\"21142\" data-col-size=\"sm\">Impact Test \u2013 Clause 12<\/td>\n<td data-start=\"21142\" data-end=\"21152\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21153\" data-end=\"21196\">\n<td data-start=\"21153\" data-end=\"21188\" data-col-size=\"sm\">Freedom from Defects \u2013 Clause 13<\/td>\n<td data-start=\"21188\" data-end=\"21196\" data-col-size=\"sm\">\u20b9500<\/td>\n<\/tr>\n<tr data-start=\"21197\" data-end=\"21216\">\n<td data-start=\"21197\" data-end=\"21206\" data-col-size=\"sm\">Carbon<\/td>\n<td data-start=\"21206\" data-end=\"21216\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21217\" data-end=\"21237\">\n<td data-start=\"21217\" data-end=\"21227\" data-col-size=\"sm\">Silicon<\/td>\n<td data-start=\"21227\" data-end=\"21237\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21238\" data-end=\"21260\">\n<td data-start=\"21238\" data-end=\"21250\" data-col-size=\"sm\">Manganese<\/td>\n<td data-start=\"21250\" data-end=\"21260\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21261\" data-end=\"21284\">\n<td data-start=\"21261\" data-end=\"21274\" data-col-size=\"sm\">Phosphorus<\/td>\n<td data-start=\"21274\" data-end=\"21284\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21285\" data-end=\"21305\">\n<td data-start=\"21285\" data-end=\"21295\" data-col-size=\"sm\">Sulphur<\/td>\n<td data-start=\"21295\" data-end=\"21305\" data-col-size=\"sm\">\u20b91,000<\/td>\n<\/tr>\n<tr data-start=\"21306\" data-end=\"21327\">\n<td data-start=\"21306\" data-end=\"21317\" data-col-size=\"sm\">Chromium<\/td>\n<td data-start=\"21317\" data-end=\"21327\" data-col-size=\"sm\">\u20b91,500<\/td>\n<\/tr>\n<tr data-start=\"21328\" data-end=\"21351\">\n<td data-start=\"21328\" data-end=\"21341\" data-col-size=\"sm\">Molybdenum<\/td>\n<td data-start=\"21341\" data-end=\"21351\" data-col-size=\"sm\">\u20b91,500<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"21353\" data-end=\"21392\">\n<p data-start=\"21394\" data-end=\"21544\">Another current BIS LIMS listing shows a testing charge of <strong data-start=\"21453\" data-end=\"21463\">\u20b98,100<\/strong> for IS 15103:2002 at another laboratory.<\/p>\n<p data-start=\"21546\" data-end=\"21641\">These are laboratory-specific testing charges and <strong data-start=\"21596\" data-end=\"21640\">are not the total BIS certification cost<\/strong>.<\/p>\n<h1 data-section-id=\"e5mxg4\" data-start=\"21643\" data-end=\"21692\">BIS Certification Cost for Fire Resistant Steel<\/h1>\n<p data-start=\"21694\" data-end=\"21775\">There is no single fixed BIS certification cost applicable to every manufacturer.<\/p>\n<p data-start=\"21777\" data-end=\"21806\">The total cost may depend on:<\/p>\n<ul data-start=\"21808\" data-end=\"22103\">\n<li data-section-id=\"qbv4f3\" data-start=\"21808\" data-end=\"21830\">BIS application fees<\/li>\n<li data-section-id=\"khts3h\" data-start=\"21831\" data-end=\"21851\">Laboratory testing<\/li>\n<li data-section-id=\"vmfc4k\" data-start=\"21852\" data-end=\"21870\">Number of grades<\/li>\n<li data-section-id=\"7x08ue\" data-start=\"21871\" data-end=\"21886\">Product forms<\/li>\n<li data-section-id=\"1w40xrm\" data-start=\"21887\" data-end=\"21899\">Size range<\/li>\n<li data-section-id=\"6jtuf\" data-start=\"21900\" data-end=\"21910\">Grouping<\/li>\n<li data-section-id=\"189nvic\" data-start=\"21911\" data-end=\"21945\">Number of representative samples<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"21946\" data-end=\"21966\">Factory assessment<\/li>\n<li data-section-id=\"17e85rw\" data-start=\"21967\" data-end=\"22006\">High-temperature testing arrangements<\/li>\n<li data-section-id=\"hrwpmc\" data-start=\"22007\" data-end=\"22026\">Testing equipment<\/li>\n<li data-section-id=\"zkwwle\" data-start=\"22027\" data-end=\"22040\">Calibration<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"22041\" data-end=\"22056\">Documentation<\/li>\n<li data-section-id=\"w80kxv\" data-start=\"22057\" data-end=\"22081\">Retesting, if required<\/li>\n<li data-section-id=\"1q8f3t4\" data-start=\"22082\" data-end=\"22103\">Consultancy charges<\/li>\n<\/ul>\n<p data-start=\"22105\" data-end=\"22252\">For an accurate quotation, the manufacturer&#8217;s <strong data-start=\"22151\" data-end=\"22217\">grade, product form, size range and proposed BIS licence scope<\/strong> should be assessed before testing.<\/p>\n<h1 data-section-id=\"p3hk5k\" data-start=\"22254\" data-end=\"22296\">Documents Required for BIS Certification<\/h1>\n<p data-start=\"22298\" data-end=\"22328\">Typical documents may include:<\/p>\n<ul data-start=\"22330\" data-end=\"23009\">\n<li data-section-id=\"laj0jm\" data-start=\"22330\" data-end=\"22362\">Company registration documents<\/li>\n<li data-section-id=\"a8o83y\" data-start=\"22363\" data-end=\"22386\">Factory address proof<\/li>\n<li data-section-id=\"17ibqzq\" data-start=\"22387\" data-end=\"22403\">Factory layout<\/li>\n<li data-section-id=\"2qrcjh\" data-start=\"22404\" data-end=\"22438\">Manufacturing process flow chart<\/li>\n<li data-section-id=\"ef1hg\" data-start=\"22439\" data-end=\"22455\">Machinery list<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"22456\" data-end=\"22480\">Product specifications<\/li>\n<li data-section-id=\"7wt11b\" data-start=\"22481\" data-end=\"22496\">Grade details<\/li>\n<li data-section-id=\"1l3bwwn\" data-start=\"22497\" data-end=\"22519\">Product form details<\/li>\n<li data-section-id=\"1w40xrm\" data-start=\"22520\" data-end=\"22532\">Size range<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"22533\" data-end=\"22551\">Product drawings<\/li>\n<li data-section-id=\"cjqh7s\" data-start=\"22552\" data-end=\"22574\">Raw-material details<\/li>\n<li data-section-id=\"45bmzc\" data-start=\"22575\" data-end=\"22594\">Heat\/cast details<\/li>\n<li data-section-id=\"1xxybf7\" data-start=\"22595\" data-end=\"22623\">Material test certificates<\/li>\n<li data-section-id=\"rziqi5\" data-start=\"22624\" data-end=\"22651\">Chemical-analysis records<\/li>\n<li data-section-id=\"1qi33mm\" data-start=\"22652\" data-end=\"22670\">Supplier details<\/li>\n<li data-section-id=\"1fo8gvq\" data-start=\"22671\" data-end=\"22695\">Testing equipment list<\/li>\n<li data-section-id=\"1ymt51g\" data-start=\"22696\" data-end=\"22722\">Calibration certificates<\/li>\n<li data-section-id=\"5vctzt\" data-start=\"22723\" data-end=\"22747\">Quality Assurance Plan<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"22748\" data-end=\"22768\">Inspection records<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"22769\" data-end=\"22789\">Production records<\/li>\n<li data-section-id=\"xl4mzn\" data-start=\"22790\" data-end=\"22804\">Test reports<\/li>\n<li data-section-id=\"ycp573\" data-start=\"22805\" data-end=\"22836\">High-temperature test records<\/li>\n<li data-section-id=\"ke2w7j\" data-start=\"22837\" data-end=\"22858\">Impact-test records<\/li>\n<li data-section-id=\"5imwtc\" data-start=\"22859\" data-end=\"22878\">Bend-test records<\/li>\n<li data-section-id=\"684x8w\" data-start=\"22879\" data-end=\"22900\">Product photographs<\/li>\n<li data-section-id=\"1uio16b\" data-start=\"22901\" data-end=\"22918\">Packing details<\/li>\n<li data-section-id=\"1hcgcf\" data-start=\"22919\" data-end=\"22936\">Marking details<\/li>\n<li data-section-id=\"lp672w\" data-start=\"22937\" data-end=\"22969\">Authorised signatory documents<\/li>\n<li data-section-id=\"8zjtnv\" data-start=\"22970\" data-end=\"23009\">Trademark documents, where applicable<\/li>\n<\/ul>\n<p data-start=\"23011\" data-end=\"23101\">The exact documents depend on the manufacturing facility and proposed certification scope.<\/p>\n<h1 data-section-id=\"7n2au7\" data-start=\"23103\" data-end=\"23125\">Marking Requirements<\/h1>\n<p data-start=\"23127\" data-end=\"23177\">Marking is an important part of BIS certification.<\/p>\n<p data-start=\"23179\" data-end=\"23251\">BIS&#8217;s technical summary identifies the grade end-marking arrangement as:<\/p>\n<p data-start=\"23253\" data-end=\"23283\"><strong data-start=\"23253\" data-end=\"23283\">FR-Fe 410 \/ Grade A \u2013 Blue<\/strong><\/p>\n<p data-start=\"23285\" data-end=\"23355\"><strong data-start=\"23285\" data-end=\"23314\">FR-Fe 490 \/ Grade B \u2013 Red<\/strong>.<\/p>\n<p data-start=\"23357\" data-end=\"23486\">The manufacturer must also follow the applicable BIS requirements for the Standard Mark, product identification and traceability.<\/p>\n<p data-start=\"23488\" data-end=\"23634\">The current marking requirements should be implemented according to the latest edition of the standard, BIS Product Manual and licence conditions.<\/p>\n<h1 data-section-id=\"1ufxuqp\" data-start=\"23636\" data-end=\"23681\">Common Reasons for BIS Certification Delays<\/h1>\n<p data-start=\"23683\" data-end=\"23730\">Manufacturers may experience delays because of:<\/p>\n<ul data-start=\"23732\" data-end=\"24294\">\n<li data-section-id=\"n6hoec\" data-start=\"23732\" data-end=\"23759\">Incorrect grade selection<\/li>\n<li data-section-id=\"54ieek\" data-start=\"23760\" data-end=\"23784\">Incorrect product form<\/li>\n<li data-section-id=\"qnzs1c\" data-start=\"23785\" data-end=\"23810\">Incorrect product scope<\/li>\n<li data-section-id=\"11jbz09\" data-start=\"23811\" data-end=\"23841\">Chemical-composition failure<\/li>\n<li data-section-id=\"xcoyzl\" data-start=\"23842\" data-end=\"23877\">Carbon or alloy-element deviation<\/li>\n<li data-section-id=\"1n7rqdn\" data-start=\"23878\" data-end=\"23912\">High-temperature tensile failure<\/li>\n<li data-section-id=\"kur1jw\" data-start=\"23913\" data-end=\"23938\">Ambient tensile failure<\/li>\n<li data-section-id=\"1f7cs4e\" data-start=\"23939\" data-end=\"23958\">Bend-test failure<\/li>\n<li data-section-id=\"j1skj5\" data-start=\"23959\" data-end=\"23980\">Impact-test failure<\/li>\n<li data-section-id=\"1pcnrsr\" data-start=\"23981\" data-end=\"23998\">Surface defects<\/li>\n<li data-section-id=\"1efam75\" data-start=\"23999\" data-end=\"24012\">Laminations<\/li>\n<li data-section-id=\"1tyl2ef\" data-start=\"24013\" data-end=\"24041\">Dimensional non-conformity<\/li>\n<li data-section-id=\"17p9buv\" data-start=\"24042\" data-end=\"24088\">Inadequate high-temperature testing facility<\/li>\n<li data-section-id=\"jaist4\" data-start=\"24089\" data-end=\"24118\">Missing calibration records<\/li>\n<li data-section-id=\"1wbchiz\" data-start=\"24119\" data-end=\"24148\">Poor heat\/cast traceability<\/li>\n<li data-section-id=\"1ritz6f\" data-start=\"24149\" data-end=\"24177\">Incorrect sample selection<\/li>\n<li data-section-id=\"1lyyp0l\" data-start=\"24178\" data-end=\"24206\">Incorrect product grouping<\/li>\n<li data-section-id=\"1pruwyv\" data-start=\"24207\" data-end=\"24241\">Factory not ready for inspection<\/li>\n<li data-section-id=\"1ks1oyx\" data-start=\"24242\" data-end=\"24274\">Incomplete technical documents<\/li>\n<li data-section-id=\"1q7qwro\" data-start=\"24275\" data-end=\"24294\">Incorrect marking<\/li>\n<\/ul>\n<p data-start=\"24296\" data-end=\"24428\">A pre-certification review of chemistry, product grouping and high-temperature testing capability can help prevent avoidable delays.<\/p>\n<h1 data-section-id=\"18m5xaq\" data-start=\"24430\" data-end=\"24486\">Benefits of BIS Certification for Fire Resistant Steel<\/h1>\n<h3 data-section-id=\"15cgiwz\" data-start=\"24488\" data-end=\"24513\">Regulatory Compliance<\/h3>\n<p data-start=\"24515\" data-end=\"24589\">Helps manufacturers comply with applicable BIS and Steel QCO requirements.<\/p>\n<h3 data-section-id=\"tf1c9s\" data-start=\"24591\" data-end=\"24603\">ISI Mark<\/h3>\n<p data-start=\"24605\" data-end=\"24708\">Allows eligible manufacturers to use the BIS Standard Mark on products covered by the approved licence.<\/p>\n<h3 data-section-id=\"16gol1t\" data-start=\"24710\" data-end=\"24746\">Elevated-Temperature Performance<\/h3>\n<p data-start=\"24748\" data-end=\"24852\">High-temperature tensile testing provides a basis for evaluating the specified performance at <strong data-start=\"24842\" data-end=\"24851\">600\u00b0C<\/strong>.<\/p>\n<h3 data-section-id=\"aju9cw\" data-start=\"24854\" data-end=\"24885\">Consistent Material Quality<\/h3>\n<p data-start=\"24887\" data-end=\"24967\">Chemical and mechanical testing supports consistency between production batches.<\/p>\n<h3 data-section-id=\"1oa4frm\" data-start=\"24969\" data-end=\"24996\">Structural Applications<\/h3>\n<p data-start=\"24998\" data-end=\"25092\">Certified fire resistant steel can be used in structural applications covered by the standard.<\/p>\n<h3 data-section-id=\"k08kti\" data-start=\"25094\" data-end=\"25117\">Customer Confidence<\/h3>\n<p data-start=\"25119\" data-end=\"25229\">BIS certification can strengthen confidence among structural steel buyers, contractors and project developers.<\/p>\n<h3 data-section-id=\"s62ca3\" data-start=\"25231\" data-end=\"25252\">Market Acceptance<\/h3>\n<p data-start=\"25254\" data-end=\"25335\">Certification supports legal market access where BIS certification is compulsory.<\/p>\n<h3 data-section-id=\"jvxxdo\" data-start=\"25337\" data-end=\"25363\">Better Quality Control<\/h3>\n<p data-start=\"25365\" data-end=\"25461\">The certification framework encourages systematic chemical, mechanical and dimensional controls.<\/p>\n<h1 data-section-id=\"18jhjpw\" data-start=\"25463\" data-end=\"25493\">Why Choose Qualitance India?<\/h1>\n<p data-start=\"25495\" data-end=\"25625\"><strong data-start=\"25495\" data-end=\"25515\">Qualitance India<\/strong> provides professional BIS Certification Consultancy for manufacturers seeking BIS and ISI Mark certification.<\/p>\n<p data-start=\"25627\" data-end=\"25714\">For <strong data-start=\"25631\" data-end=\"25676\">Fire Resistant Steel as per IS 15103:2002<\/strong>, our consultancy support can include:<\/p>\n<ul data-start=\"25716\" data-end=\"26315\">\n<li data-section-id=\"1mfdgr4\" data-start=\"25716\" data-end=\"25750\">Product applicability assessment<\/li>\n<li data-section-id=\"vk8wbf\" data-start=\"25751\" data-end=\"25785\">IS 15103:2002 requirement review<\/li>\n<li data-section-id=\"ajx2c9\" data-start=\"25786\" data-end=\"25820\">FR-Fe 410 \/ FR-Fe 490 assessment<\/li>\n<li data-section-id=\"npjs6m\" data-start=\"25821\" data-end=\"25846\">Product-form assessment<\/li>\n<li data-section-id=\"1mqngnd\" data-start=\"25847\" data-end=\"25870\">Size-range assessment<\/li>\n<li data-section-id=\"ykvcbu\" data-start=\"25871\" data-end=\"25898\">Product grouping guidance<\/li>\n<li data-section-id=\"13ne8bc\" data-start=\"25899\" data-end=\"25926\">Sample selection guidance<\/li>\n<li data-section-id=\"1olazsl\" data-start=\"25927\" data-end=\"25958\">Chemical testing coordination<\/li>\n<li data-section-id=\"7knte0\" data-start=\"25959\" data-end=\"25997\">Ambient tensile-testing coordination<\/li>\n<li data-section-id=\"1npb4l6\" data-start=\"25998\" data-end=\"26051\">600\u00b0C high-temperature tensile-testing coordination<\/li>\n<li data-section-id=\"1rn4il8\" data-start=\"26052\" data-end=\"26079\">Bend testing coordination<\/li>\n<li data-section-id=\"7ed86r\" data-start=\"26080\" data-end=\"26109\">Impact testing coordination<\/li>\n<li data-section-id=\"zrfurn\" data-start=\"26110\" data-end=\"26137\">Documentation preparation<\/li>\n<li data-section-id=\"maajyk\" data-start=\"26138\" data-end=\"26166\">BIS application assistance<\/li>\n<li data-section-id=\"sy9ixn\" data-start=\"26167\" data-end=\"26199\">Factory inspection preparation<\/li>\n<li data-section-id=\"14qpm0y\" data-start=\"26200\" data-end=\"26228\">Testing equipment guidance<\/li>\n<li data-section-id=\"1bxrev1\" data-start=\"26229\" data-end=\"26260\">Quality-control documentation<\/li>\n<li data-section-id=\"3i8g1g\" data-start=\"26261\" data-end=\"26290\">Observation closure support<\/li>\n<li data-section-id=\"kobqql\" data-start=\"26291\" data-end=\"26315\">BIS licence assistance<\/li>\n<\/ul>\n<p data-start=\"26317\" data-end=\"26513\">Our support is designed to help manufacturers manage the certification process from initial product assessment through laboratory testing, BIS application, factory assessment and licence approval.<\/p>\n<h3 data-section-id=\"16z2skw\" data-start=\"26515\" data-end=\"26543\">Contact Qualitance India<\/h3>\n<p data-start=\"26545\" data-end=\"26644\"><strong data-start=\"26545\" data-end=\"26555\">Phone:<\/strong> +91 93106 15170<br data-start=\"26571\" data-end=\"26574\" \/><strong data-start=\"26574\" data-end=\"26584\">Email:<\/strong> <a class=\"decorated-link\" href=\"mailto:info@qualitanceindia.com\" rel=\"noopener\" data-start=\"26585\" data-end=\"26609\">info@qualitanceindia.com<\/a><br data-start=\"26609\" data-end=\"26612\" \/><strong data-start=\"26612\" data-end=\"26624\">Website:<\/strong> qualitanceindia.com<\/p>\n<h1 data-section-id=\"cco78p\" data-start=\"26646\" data-end=\"26686\">BIS Certification Process \u2013 Quick Flow<\/h1>\n<p data-start=\"26688\" data-end=\"27384\"><strong data-start=\"26688\" data-end=\"26714\">Product Identification<\/strong><br data-start=\"26714\" data-end=\"26717\" \/>\u2193<br data-start=\"26718\" data-end=\"26721\" \/><strong data-start=\"26721\" data-end=\"26757\">IS 15103:2002 Requirement Review<\/strong><br data-start=\"26757\" data-end=\"26760\" \/>\u2193<br data-start=\"26761\" data-end=\"26764\" \/><strong data-start=\"26764\" data-end=\"26812\">Grade Identification \u2013 FR-Fe 410 \/ FR-Fe 490<\/strong><br data-start=\"26812\" data-end=\"26815\" \/>\u2193<br data-start=\"26816\" data-end=\"26819\" \/><strong data-start=\"26819\" data-end=\"26863\">Plate \/ Strip \/ Section \/ Bar Assessment<\/strong><br data-start=\"26863\" data-end=\"26866\" \/>\u2193<br data-start=\"26867\" data-end=\"26870\" \/><strong data-start=\"26870\" data-end=\"26897\">Size &amp; Product Grouping<\/strong><br data-start=\"26897\" data-end=\"26900\" \/>\u2193<br data-start=\"26901\" data-end=\"26904\" \/><strong data-start=\"26904\" data-end=\"26934\">Licence Scope Finalisation<\/strong><br data-start=\"26934\" data-end=\"26937\" \/>\u2193<br data-start=\"26938\" data-end=\"26941\" \/><strong data-start=\"26941\" data-end=\"26970\">Documentation Preparation<\/strong><br data-start=\"26970\" data-end=\"26973\" \/>\u2193<br data-start=\"26974\" data-end=\"26977\" \/><strong data-start=\"26977\" data-end=\"27014\">Representative Sample Preparation<\/strong><br data-start=\"27014\" data-end=\"27017\" \/>\u2193<br data-start=\"27018\" data-end=\"27021\" \/><strong data-start=\"27021\" data-end=\"27053\">Chemical Composition Testing<\/strong><br data-start=\"27053\" data-end=\"27056\" \/>\u2193<br data-start=\"27057\" data-end=\"27060\" \/><strong data-start=\"27060\" data-end=\"27096\">Ambient Temperature Tensile Test<\/strong><br data-start=\"27096\" data-end=\"27099\" \/>\u2193<br data-start=\"27100\" data-end=\"27103\" \/><strong data-start=\"27103\" data-end=\"27146\">600\u00b0C Elevated Temperature Tensile Test<\/strong><br data-start=\"27146\" data-end=\"27149\" \/>\u2193<br data-start=\"27150\" data-end=\"27153\" \/><strong data-start=\"27153\" data-end=\"27166\">Bend Test<\/strong><br data-start=\"27166\" data-end=\"27169\" \/>\u2193<br data-start=\"27170\" data-end=\"27173\" \/><strong data-start=\"27173\" data-end=\"27188\">Impact Test<\/strong><br data-start=\"27188\" data-end=\"27191\" \/>\u2193<br data-start=\"27192\" data-end=\"27195\" \/><strong data-start=\"27195\" data-end=\"27214\">BIS Application<\/strong><br data-start=\"27214\" data-end=\"27217\" \/>\u2193<br data-start=\"27218\" data-end=\"27221\" \/><strong data-start=\"27221\" data-end=\"27245\">Application Scrutiny<\/strong><br data-start=\"27245\" data-end=\"27248\" \/>\u2193<br data-start=\"27249\" data-end=\"27252\" \/><strong data-start=\"27252\" data-end=\"27274\">Factory Assessment<\/strong><br data-start=\"27274\" data-end=\"27277\" \/>\u2193<br data-start=\"27278\" data-end=\"27281\" \/><strong data-start=\"27281\" data-end=\"27304\">Observation Closure<\/strong><br data-start=\"27304\" data-end=\"27307\" \/>\u2193<br data-start=\"27308\" data-end=\"27311\" \/><strong data-start=\"27311\" data-end=\"27332\">BIS Licence Grant<\/strong><br data-start=\"27332\" data-end=\"27335\" \/>\u2193<br data-start=\"27336\" data-end=\"27339\" \/><strong data-start=\"27339\" data-end=\"27384\">ISI Mark on Approved Fire Resistant Steel<\/strong><\/p>\n<h1 data-section-id=\"hkd5a4\" data-start=\"27386\" data-end=\"27414\">Frequently Asked Questions<\/h1>\n<h2 data-section-id=\"vcxco3\" data-start=\"27416\" data-end=\"27444\">1. What is IS 15103:2002?<\/h2>\n<p data-start=\"27446\" data-end=\"27531\">IS 15103:2002 is the Indian Standard titled <strong data-start=\"27490\" data-end=\"27530\">Fire Resistant Steel \u2013 Specification<\/strong>.<\/p>\n<h2 data-section-id=\"q1zkgk\" data-start=\"27533\" data-end=\"27568\">2. What is fire resistant steel?<\/h2>\n<p data-start=\"27570\" data-end=\"27829\">Fire resistant steel is structural steel designed to provide specified strength performance at elevated temperatures. IS 15103 covers steel intended for structural work up to <strong data-start=\"27745\" data-end=\"27788\">600\u00b0C for a maximum duration of 3 hours<\/strong>.<\/p>\n<h2 data-section-id=\"ibxw45\" data-start=\"27831\" data-end=\"27876\">3. What grades are covered under IS 15103?<\/h2>\n<p data-start=\"27878\" data-end=\"27913\">The standard identifies two grades:<\/p>\n<p data-start=\"27915\" data-end=\"27938\"><strong data-start=\"27915\" data-end=\"27938\">FR-Fe 410 \u2013 Grade A<\/strong><\/p>\n<p data-start=\"27940\" data-end=\"28004\"><strong data-start=\"27940\" data-end=\"27963\">FR-Fe 490 \u2013 Grade B<\/strong>.<\/p>\n<h2 data-section-id=\"1ehmmug\" data-start=\"28006\" data-end=\"28038\">4. What products are covered?<\/h2>\n<p data-start=\"28040\" data-end=\"28138\">The standard covers <strong data-start=\"28060\" data-end=\"28097\">plates, strips, sections and bars<\/strong>.<\/p>\n<h2 data-section-id=\"pogks\" data-start=\"28140\" data-end=\"28177\">5. Is BIS certification mandatory?<\/h2>\n<p data-start=\"28179\" data-end=\"28358\">Yes. IS 15103:2002 is specifically listed in the <strong data-start=\"28228\" data-end=\"28286\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, with immediate implementation.<\/p>\n<h2 data-section-id=\"kbre2l\" data-start=\"28360\" data-end=\"28404\">6. What chemical elements are controlled?<\/h2>\n<p data-start=\"28406\" data-end=\"28561\">Important controlled elements include <strong data-start=\"28444\" data-end=\"28520\">carbon, silicon, manganese, sulphur, phosphorus, chromium and molybdenum<\/strong>.<\/p>\n<h2 data-section-id=\"1apzo0m\" data-start=\"28563\" data-end=\"28611\">7. Why are chromium and molybdenum important?<\/h2>\n<p data-start=\"28613\" data-end=\"28789\">BIS explains that controlled alloying elements such as chromium and molybdenum contribute to the fire-resistant properties of the steel.<\/p>\n<h2 data-section-id=\"kajpo2\" data-start=\"28791\" data-end=\"28845\">8. Is tensile testing required at high temperature?<\/h2>\n<p data-start=\"28847\" data-end=\"28967\">Yes. IS 15103 includes tensile testing at <strong data-start=\"28889\" data-end=\"28898\">600\u00b0C<\/strong> as an important requirement.<\/p>\n<h2 data-section-id=\"1tezl9m\" data-start=\"28969\" data-end=\"29022\">9. What properties are checked in tensile testing?<\/h2>\n<p data-start=\"29024\" data-end=\"29161\">The relevant requirements include <strong data-start=\"29058\" data-end=\"29120\">tensile strength, yield strength and percentage elongation<\/strong>.<\/p>\n<h2 data-section-id=\"30ky4a\" data-start=\"29163\" data-end=\"29206\">10. What is the impact-test requirement?<\/h2>\n<p data-start=\"29208\" data-end=\"29344\">The BIS technical summary states that impact energy shall be <strong data-start=\"29269\" data-end=\"29303\">not less than 27 joules at 0\u00b0C<\/strong>.<\/p>\n<h2 data-section-id=\"1lvw27o\" data-start=\"29346\" data-end=\"29387\">11. What is the bend-test requirement?<\/h2>\n<p data-start=\"29389\" data-end=\"29564\">The test piece is doubled over with an internal diameter of approximately <strong data-start=\"29463\" data-end=\"29490\">2\u20133 times the thickness<\/strong>, and the sample should not crack.<\/p>\n<h2 data-section-id=\"tf1bj9\" data-start=\"29566\" data-end=\"29601\">12. What is the BIS sample size?<\/h2>\n<p data-start=\"29603\" data-end=\"29758\">The Product Manual specifies <strong data-start=\"29632\" data-end=\"29664\">1 metre for mechanical tests<\/strong> and <strong data-start=\"29669\" data-end=\"29717\">five 50 mm \u00d7 50 mm pieces for chemical tests<\/strong>.<\/p>\n<h2 data-section-id=\"1otrrwn\" data-start=\"29760\" data-end=\"29809\">13. Are product-grouping guidelines available?<\/h2>\n<p data-start=\"29811\" data-end=\"29937\">Yes. The BIS Product Manual directs applicants to <strong data-start=\"29861\" data-end=\"29872\">Annex A<\/strong> for grouping guidelines.<\/p>\n<h2 data-section-id=\"uyoum1\" data-start=\"29939\" data-end=\"29991\">14. Is there a specific raw-material requirement?<\/h2>\n<p data-start=\"29993\" data-end=\"30110\">The BIS Product Manual states <strong data-start=\"30023\" data-end=\"30052\">\u201cNo specific requirement\u201d<\/strong> for raw material.<\/p>\n<h2 data-section-id=\"7tet9g\" data-start=\"30112\" data-end=\"30158\">15. What is the current BIS testing charge?<\/h2>\n<p data-start=\"30160\" data-end=\"30405\">A current BIS LIMS entry lists <strong data-start=\"30191\" data-end=\"30218\">\u20b911,500 excluding taxes<\/strong> for all grades, sizes and designations at the National Institute of Secondary Steel Technology. Another current laboratory entry lists <strong data-start=\"30354\" data-end=\"30364\">\u20b98,100<\/strong>.<\/p>\n<h2 data-section-id=\"i04yoa\" data-start=\"30407\" data-end=\"30445\">16. Is factory inspection required?<\/h2>\n<p data-start=\"30447\" data-end=\"30524\">Yes. Factory assessment forms part of the BIS Scheme-I certification process.<\/p>\n<h2 data-section-id=\"yk3an5\" data-start=\"30526\" data-end=\"30560\">17. What equipment is required?<\/h2>\n<p data-start=\"30562\" data-end=\"30838\">The BIS Product Manual directs applicants to Annex B for testing equipment. Facilities can include tensile-testing, high-temperature tensile-testing, bend-testing, impact-testing, chemical-analysis and dimensional-measurement equipment.<\/p>\n<h2 data-section-id=\"1m1bryh\" data-start=\"30840\" data-end=\"30907\">18. Can both FR-Fe 410 and FR-Fe 490 be included in the licence?<\/h2>\n<p data-start=\"30909\" data-end=\"31123\">The applicable licence scope and grouping depend on the current BIS Product Manual and the manufacturer&#8217;s manufacturing and testing capabilities. Grade-specific representative testing should be planned accordingly.<\/p>\n<h2 data-section-id=\"1r8kum8\" data-start=\"31125\" data-end=\"31169\">19. How long does BIS certification take?<\/h2>\n<p data-start=\"31171\" data-end=\"31338\">The timeline depends on product scope, grouping, documentation, laboratory availability, testing, application scrutiny, factory assessment and closure of observations.<\/p>\n<h2 data-section-id=\"v858mp\" data-start=\"31340\" data-end=\"31406\">20. Can Qualitance India help with IS 15103:2002 certification?<\/h2>\n<p data-start=\"31408\" data-end=\"31585\">Yes. Qualitance India provides product assessment, grouping guidance, documentation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<h1 data-section-id=\"g38lxp\" data-start=\"31587\" data-end=\"31604\">People Also Ask<\/h1>\n<h3 data-section-id=\"6diowg\" data-start=\"31606\" data-end=\"31661\">What is BIS certification for fire resistant steel?<\/h3>\n<p data-start=\"31663\" data-end=\"31834\">BIS certification for fire resistant steel is the conformity-assessment process for demonstrating compliance with <strong data-start=\"31777\" data-end=\"31833\">IS 15103:2002 \u2013 Fire Resistant Steel \u2013 Specification<\/strong>.<\/p>\n<h3 data-section-id=\"1ov47up\" data-start=\"31836\" data-end=\"31869\">Is IS 15103:2002 under a QCO?<\/h3>\n<p data-start=\"31871\" data-end=\"32052\">Yes. IS 15103:2002 is specifically listed under the <strong data-start=\"31923\" data-end=\"31981\">Steel and Steel Products (Quality Control) Order, 2024<\/strong> with immediate implementation.<\/p>\n<h3 data-section-id=\"1aqy23u\" data-start=\"32054\" data-end=\"32108\">What is the BIS standard for fire resistant steel?<\/h3>\n<p data-start=\"32110\" data-end=\"32201\">The applicable Indian Standard is <strong data-start=\"32144\" data-end=\"32200\">IS 15103:2002 \u2013 Fire Resistant Steel \u2013 Specification<\/strong>.<\/p>\n<h3 data-section-id=\"tjjbkh\" data-start=\"32203\" data-end=\"32251\">What are the grades of fire resistant steel?<\/h3>\n<p data-start=\"32253\" data-end=\"32369\">The standard identifies <strong data-start=\"32277\" data-end=\"32300\">FR-Fe 410 (Grade A)<\/strong> and <strong data-start=\"32305\" data-end=\"32328\">FR-Fe 490 (Grade B)<\/strong>.<\/p>\n<h3 data-section-id=\"1tehyfj\" data-start=\"32371\" data-end=\"32427\">What is the maximum temperature covered by IS 15103?<\/h3>\n<p data-start=\"32429\" data-end=\"32611\">The BIS technical summary states that the covered products are intended for structural work up to <strong data-start=\"32527\" data-end=\"32570\">600\u00b0C for a maximum duration of 3 hours<\/strong>.<\/p>\n<h3 data-section-id=\"h6olom\" data-start=\"32613\" data-end=\"32655\">What products are covered by IS 15103?<\/h3>\n<p data-start=\"32657\" data-end=\"32743\">Plates, strips, sections and bars are covered.<\/p>\n<h3 data-section-id=\"cnnyb4\" data-start=\"32745\" data-end=\"32798\">What tests are required for fire resistant steel?<\/h3>\n<p data-start=\"32800\" data-end=\"32975\">Major requirements include chemical composition, ambient-temperature tensile testing, 600\u00b0C tensile testing, bend test, impact test, freedom from defects, mass and dimensions.<\/p>\n<h3 data-section-id=\"842ve5\" data-start=\"32977\" data-end=\"33031\">How do I get an ISI Mark for fire resistant steel?<\/h3>\n<p data-start=\"33033\" data-end=\"33206\">A manufacturer must obtain the applicable BIS licence for IS 15103:2002 and comply with BIS requirements for testing, inspection, Standard Marking and continuing conformity.<\/p>\n<h1 data-section-id=\"okqknw\" data-start=\"33208\" data-end=\"33238\">Frequently Searched Keywords<\/h1>\n<ul data-start=\"33240\" data-end=\"33764\">\n<li data-section-id=\"84frqp\" data-start=\"33240\" data-end=\"33284\">BIS Certification for Fire Resistant Steel<\/li>\n<li data-section-id=\"1ynlu65\" data-start=\"33285\" data-end=\"33338\">BIS Certification for Fire Resistant Steel IS 15103<\/li>\n<li data-section-id=\"lighty\" data-start=\"33339\" data-end=\"33368\">IS 15103:2002 Certification<\/li>\n<li data-section-id=\"16qrxhe\" data-start=\"33369\" data-end=\"33407\">BIS Licence for Fire Resistant Steel<\/li>\n<li data-section-id=\"1odyrxm\" data-start=\"33408\" data-end=\"33448\">Fire Resistant Steel BIS Certification<\/li>\n<li data-section-id=\"r44oh8\" data-start=\"33449\" data-end=\"33480\">Fire Resistant Steel ISI Mark<\/li>\n<li data-section-id=\"trsrnb\" data-start=\"33481\" data-end=\"33503\">IS 15103 BIS Licence<\/li>\n<li data-section-id=\"1fzh3p8\" data-start=\"33504\" data-end=\"33534\">Fire Resistant Steel Testing<\/li>\n<li data-section-id=\"1bbt13b\" data-start=\"33535\" data-end=\"33564\">FR-Fe 410 BIS Certification<\/li>\n<li data-section-id=\"1hfyztb\" data-start=\"33565\" data-end=\"33594\">FR-Fe 490 BIS Certification<\/li>\n<li data-section-id=\"6he5h3\" data-start=\"33595\" data-end=\"33621\">Fire Resistant Steel QCO<\/li>\n<li data-section-id=\"x9hd1y\" data-start=\"33622\" data-end=\"33647\">Steel QCO 2024 IS 15103<\/li>\n<li data-section-id=\"18of9wh\" data-start=\"33648\" data-end=\"33679\">BIS Certification Consultancy<\/li>\n<li data-section-id=\"1fn20i6\" data-start=\"33680\" data-end=\"33721\">BIS Consultant for Fire Resistant Steel<\/li>\n<li data-section-id=\"w6qph3\" data-start=\"33722\" data-end=\"33764\">600\u00b0C Fire Resistant Steel Certification<\/li>\n<\/ul>\n<h1 data-section-id=\"fphl3b\" data-start=\"33766\" data-end=\"33802\">Related BIS Certification Services<\/h1>\n<ul data-start=\"33804\" data-end=\"34333\">\n<li data-section-id=\"1gr9s8z\" data-start=\"33804\" data-end=\"33878\">BIS Certification for Structural Weather Resistant Steel \u2013 IS 11587:1986<\/li>\n<li data-section-id=\"n7a7ka\" data-start=\"33879\" data-end=\"33929\">BIS Certification for Structural Steel \u2013 IS 2062<\/li>\n<li data-section-id=\"oq6evu\" data-start=\"33930\" data-end=\"34019\">BIS Certification for Structural Steel with Improved Seismic Resistance \u2013 IS 15962:2012<\/li>\n<li data-section-id=\"jccq4\" data-start=\"34020\" data-end=\"34087\">BIS Certification for Galvanized Structural Steel \u2013 IS 16732:2019<\/li>\n<li data-section-id=\"1of5nce\" data-start=\"34088\" data-end=\"34142\">BIS Certification for High Strength Structural Steel<\/li>\n<li data-section-id=\"1mjt252\" data-start=\"34143\" data-end=\"34192\">BIS Certification for Steel Plates and Sections<\/li>\n<li data-section-id=\"12dqj6p\" data-start=\"34193\" data-end=\"34239\">BIS Certification for Special Steel Products<\/li>\n<li data-section-id=\"1rizx3c\" data-start=\"34240\" data-end=\"34270\">BIS &amp; ISI Mark Certification<\/li>\n<li data-section-id=\"1rdhe7w\" data-start=\"34271\" data-end=\"34306\">BIS Factory Inspection Assistance<\/li>\n<li data-section-id=\"284mi1\" data-start=\"34307\" data-end=\"34333\">BIS Testing Coordination<\/li>\n<\/ul>\n<h1 data-section-id=\"fsb6xx\" data-start=\"34335\" data-end=\"34347\">Conclusion<\/h1>\n<p data-start=\"34349\" data-end=\"34743\"><strong data-start=\"34349\" data-end=\"34405\">IS 15103:2002 \u2013 Fire Resistant Steel \u2013 Specification<\/strong> establishes requirements for fire resistant steel used in structural applications where steel may be exposed to elevated temperatures and fluctuating stresses. The standard covers <strong data-start=\"34586\" data-end=\"34623\">plates, strips, sections and bars<\/strong> and identifies two grades: <strong data-start=\"34651\" data-end=\"34674\">FR-Fe 410 (Grade A)<\/strong> and <strong data-start=\"34679\" data-end=\"34702\">FR-Fe 490 (Grade B)<\/strong>.<\/p>\n<p data-start=\"34745\" data-end=\"35084\">One of the most important features of IS 15103 is its requirement for evaluating steel performance at <strong data-start=\"34847\" data-end=\"34856\">600\u00b0C<\/strong>, in addition to ambient-temperature mechanical properties. The standard also covers <strong data-start=\"34941\" data-end=\"35043\">chemical composition, bend performance, impact strength, freedom from defects, mass and dimensions<\/strong>.<\/p>\n<p data-start=\"35086\" data-end=\"35403\">The BIS Product Manual specifies <strong data-start=\"35119\" data-end=\"35205\">1 metre mechanical-test samples and five 50 mm \u00d7 50 mm pieces for chemical testing<\/strong>, provides grouping guidance through <strong data-start=\"35242\" data-end=\"35253\">Annex A<\/strong>, testing-equipment guidance through <strong data-start=\"35290\" data-end=\"35301\">Annex B<\/strong> and the Scheme of Inspection and Testing through <strong data-start=\"35351\" data-end=\"35362\">Annex C<\/strong>.<\/p>\n<p data-start=\"35405\" data-end=\"35569\">IS 15103:2002 is also included in the <strong data-start=\"35443\" data-end=\"35501\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, with <strong data-start=\"35508\" data-end=\"35528\">immediate effect<\/strong>.<\/p>\n<p data-start=\"35571\" data-end=\"35917\">Manufacturers should therefore pay particular attention to <strong data-start=\"35630\" data-end=\"35878\">FR-Fe 410 \/ FR-Fe 490 grade selection, chemical composition, chromium and molybdenum control, ambient and 600\u00b0C tensile properties, impact strength, bend performance, dimensional accuracy, defect control, product grouping and testing capability<\/strong> before applying for BIS certification.<\/p>\n<p data-start=\"35919\" data-end=\"36189\">Current BIS LIMS information shows laboratory testing availability for IS 15103:2002, with listed charges varying by laboratory and scope; one current entry shows <strong data-start=\"36082\" data-end=\"36109\">\u20b911,500 excluding taxes<\/strong> for all grades, sizes and designations.<\/p>\n<p data-start=\"36191\" data-end=\"36513\"><strong data-start=\"36191\" data-end=\"36211\">Qualitance India<\/strong> provides end-to-end <strong data-start=\"36232\" data-end=\"36311\">BIS Certification Consultancy for Fire Resistant Steel as per IS 15103:2002<\/strong>, including product assessment, grade and scope review, grouping guidance, documentation, sample preparation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<p data-start=\"36515\" data-end=\"36623\"><strong data-start=\"36515\" data-end=\"36623\">For BIS Certification and ISI Mark Consultancy for Fire Resistant Steel, contact Qualitance India today.<\/strong><\/p>\n<p data-start=\"36625\" data-end=\"36724\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"36625\" data-end=\"36635\">Phone:<\/strong> +91 93106 15170<br data-start=\"36651\" data-end=\"36654\" \/><strong data-start=\"36654\" data-end=\"36664\">Email:<\/strong> <a class=\"decorated-link\" href=\"mailto:info@qualitanceindia.com\" rel=\"noopener\" data-start=\"36665\" data-end=\"36689\">info@qualitanceindia.com<\/a><br data-start=\"36689\" data-end=\"36692\" \/><strong data-start=\"36692\" data-end=\"36704\">Website:<\/strong> qualitanceindia.com<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Fire resistant steel is specially designed for structural applications where steel components may be exposed to elevated temperatures and fluctuations in stress. Unlike ordinary structural steel, fire resistant steel is developed with controlled alloying elements to retain improved strength properties at high temperatures. In India, IS 15103:2002 \u2013 Fire Resistant Steel \u2013 Specification specifies [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3576,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"inline_featured_image":false,"slim_seo":{"title":"BIS Certification Consultancy for Fire Resistant Steel | IS 15103:2002 | BIS & ISI Mark Certification - Qualitance India","description":"Introduction Fire resistant steel is specially designed for structural applications where steel components may be exposed to elevated temperatures and fluctuati"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3575","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3575"}],"version-history":[{"count":1,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3575\/revisions"}],"predecessor-version":[{"id":3577,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3575\/revisions\/3577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3576"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3575"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3575"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a4cebdea01328942bf8f471. Config Timestamp: 2026-07-07 12:06:54 UTC, Cached Timestamp: 2026-09-10 15:55:42 UTC, Optimization Time: 2.27ms -->