{"id":3421,"date":"2026-08-14T10:34:03","date_gmt":"2026-08-14T10:34:03","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3421"},"modified":"2026-08-14T10:34:03","modified_gmt":"2026-08-14T10:34:03","slug":"bis-certification-for-butterfly-valves-for-general-purposes-is-130951991","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-for-butterfly-valves-for-general-purposes-is-130951991\/","title":{"rendered":"BIS Certification for Butterfly Valves for General Purposes | IS 13095:1991"},"content":{"rendered":"<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"tje7mo\" data-start=\"2924\" data-end=\"2957\">Introduction<\/h1>\n<p data-start=\"2959\" data-end=\"3214\"><strong data-start=\"2959\" data-end=\"3001\">BIS Certification for Butterfly Valves<\/strong> is an important compliance consideration for manufacturers whose butterfly valves fall under the applicable BIS certification requirements. <strong data-start=\"3142\" data-end=\"3159\">IS 13095:1991<\/strong> is titled <strong data-start=\"3170\" data-end=\"3214\">\u201cButterfly Valves for General Purposes.\u201d<\/strong><\/p>\n<p data-start=\"3216\" data-end=\"3560\">The standard covers double-flanged and wafer-type butterfly valves, including metal-seated and resilient-seated valves made from materials such as cast iron, ductile iron and carbon steel, as well as lined butterfly valves. The valves may be manually, pneumatically, hydraulically or electrically operated.<\/p>\n<p data-start=\"3562\" data-end=\"3804\">The original 1991 standard covers valves up to nominal pressure designations of <strong data-start=\"3642\" data-end=\"3665\">4 MPa and Class 300<\/strong>, with nominal sizes from <strong data-start=\"3691\" data-end=\"3711\">DN 40 to DN 2000<\/strong>, subject to the detailed requirements of the standard.<\/p>\n<p data-start=\"3806\" data-end=\"4154\"><strong data-start=\"3806\" data-end=\"3838\">Important for manufacturers:<\/strong> BIS has subsequently published <strong data-start=\"3870\" data-end=\"3944\">IS 13095:2020 \u2013 Butterfly Valves for General Purposes (First Revision)<\/strong>. Therefore, before filing a new BIS application, the manufacturer should verify the latest applicable standard and BIS certification requirements for the specific product.<\/p>\n<hr data-start=\"4156\" data-end=\"4159\" \/>\n<h1 data-section-id=\"2mban7\" data-start=\"4161\" data-end=\"4185\">About Butterfly Valves<\/h1>\n<p data-start=\"4187\" data-end=\"4320\">A <strong data-start=\"4189\" data-end=\"4208\">butterfly valve<\/strong> is a quarter-turn valve used to control, regulate or shut off the flow of liquids and gases through a pipeline.<\/p>\n<p data-start=\"4322\" data-end=\"4347\">It generally consists of:<\/p>\n<ul data-start=\"4349\" data-end=\"4444\">\n<li data-section-id=\"1l2yu40\" data-start=\"4349\" data-end=\"4361\">Valve body<\/li>\n<li data-section-id=\"1j40gs5\" data-start=\"4362\" data-end=\"4368\">Disc<\/li>\n<li data-section-id=\"178kucg\" data-start=\"4369\" data-end=\"4376\">Shaft<\/li>\n<li data-section-id=\"19d8fod\" data-start=\"4377\" data-end=\"4393\">Seat or lining<\/li>\n<li data-section-id=\"1awk08f\" data-start=\"4394\" data-end=\"4404\">Bearings<\/li>\n<li data-section-id=\"e6kycu\" data-start=\"4405\" data-end=\"4426\">Operating mechanism<\/li>\n<li data-section-id=\"1msbo3m\" data-start=\"4427\" data-end=\"4444\">End connections<\/li>\n<\/ul>\n<p data-start=\"4446\" data-end=\"4603\">Butterfly valves are widely used because of their relatively compact design, simple operation and suitability for different industrial pipeline applications.<\/p>\n<p data-start=\"4605\" data-end=\"4664\">They may be operated manually or through actuators such as:<\/p>\n<ul data-start=\"4666\" data-end=\"4730\">\n<li data-section-id=\"11vqbcj\" data-start=\"4666\" data-end=\"4686\">Electric actuators<\/li>\n<li data-section-id=\"tthwr0\" data-start=\"4687\" data-end=\"4708\">Pneumatic actuators<\/li>\n<li data-section-id=\"ilx32d\" data-start=\"4709\" data-end=\"4730\">Hydraulic actuators<\/li>\n<\/ul>\n<p data-start=\"4732\" data-end=\"4862\">IS 13095:1991 specifically recognizes manual, pneumatic, hydraulic and electrical operation.<\/p>\n<hr data-start=\"4864\" data-end=\"4867\" \/>\n<h1 data-section-id=\"mhwjhl\" data-start=\"4869\" data-end=\"4897\">What is BIS Certification?<\/h1>\n<p data-start=\"4899\" data-end=\"5015\"><strong data-start=\"4899\" data-end=\"4920\">BIS Certification<\/strong> is a conformity assessment mechanism administered by the <strong data-start=\"4978\" data-end=\"5014\">Bureau of Indian Standards (BIS)<\/strong>.<\/p>\n<p data-start=\"5017\" data-end=\"5252\">Where a product is covered by a compulsory BIS certification requirement, the manufacturer must demonstrate conformity with the applicable Indian Standard and comply with BIS certification conditions before using the BIS Standard Mark.<\/p>\n<p data-start=\"5254\" data-end=\"5426\">For manufacturers dealing with regulated industrial valves, determining the <strong data-start=\"5330\" data-end=\"5398\">correct applicable Indian Standard and current regulatory status<\/strong> is an essential first step.<\/p>\n<hr data-start=\"5428\" data-end=\"5431\" \/>\n<h1 data-section-id=\"uqnd5j\" data-start=\"5433\" data-end=\"5457\">What is IS 13095:1991?<\/h1>\n<p data-start=\"5459\" data-end=\"5507\"><strong data-start=\"5459\" data-end=\"5476\">IS 13095:1991<\/strong> is the Indian Standard titled:<\/p>\n<h3 data-section-id=\"1mwu7e7\" data-start=\"5509\" data-end=\"5552\">\u201cButterfly Valves for General Purposes\u201d<\/h3>\n<p data-start=\"5554\" data-end=\"5789\">The BIS Product Manual for this standard was prepared for certification under <strong data-start=\"5632\" data-end=\"5644\">Scheme-I<\/strong> and is intended to guide BIS offices, existing licensees and prospective applicants seeking certification.<\/p>\n<p data-start=\"5791\" data-end=\"5821\">The Product Manual identifies:<\/p>\n<ul data-start=\"5823\" data-end=\"5970\">\n<li data-section-id=\"86wxwj\" data-start=\"5823\" data-end=\"5838\">Product title<\/li>\n<li data-section-id=\"1sewvxo\" data-start=\"5839\" data-end=\"5861\">Product raw material<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"5862\" data-end=\"5880\">Product grouping<\/li>\n<li data-section-id=\"1qq4tya\" data-start=\"5881\" data-end=\"5902\">Sample requirements<\/li>\n<li data-section-id=\"1nr9ac4\" data-start=\"5903\" data-end=\"5919\">Test equipment<\/li>\n<li data-section-id=\"e0w5yv\" data-start=\"5920\" data-end=\"5954\">Scheme of Inspection and Testing<\/li>\n<li data-section-id=\"d8ihd5\" data-start=\"5955\" data-end=\"5970\">Licence scope<\/li>\n<\/ul>\n<p data-start=\"5972\" data-end=\"6072\">The product manual specifies <strong data-start=\"6001\" data-end=\"6014\">one valve<\/strong> as the sample size.<\/p>\n<hr data-start=\"6074\" data-end=\"6077\" \/>\n<h1 data-section-id=\"skygl7\" data-start=\"6079\" data-end=\"6103\">Scope of IS 13095:1991<\/h1>\n<p data-start=\"6105\" data-end=\"6126\">IS 13095:1991 covers:<\/p>\n<ul data-start=\"6128\" data-end=\"6377\">\n<li data-section-id=\"x1ttuj\" data-start=\"6128\" data-end=\"6161\">Double-flanged butterfly valves<\/li>\n<li data-section-id=\"ukcb5e\" data-start=\"6162\" data-end=\"6191\">Wafer-type butterfly valves<\/li>\n<li data-section-id=\"135lcm6\" data-start=\"6192\" data-end=\"6223\">Metal-seated butterfly valves<\/li>\n<li data-section-id=\"kox260\" data-start=\"6224\" data-end=\"6259\">Resilient-seated butterfly valves<\/li>\n<li data-section-id=\"1trrxxb\" data-start=\"6260\" data-end=\"6288\">Cast iron butterfly valves<\/li>\n<li data-section-id=\"1l8r870\" data-start=\"6289\" data-end=\"6320\">Ductile iron butterfly valves<\/li>\n<li data-section-id=\"1752vqw\" data-start=\"6321\" data-end=\"6352\">Carbon steel butterfly valves<\/li>\n<li data-section-id=\"635sdm\" data-start=\"6353\" data-end=\"6377\">Lined butterfly valves<\/li>\n<\/ul>\n<p data-start=\"6379\" data-end=\"6397\">The valves may be:<\/p>\n<ul data-start=\"6399\" data-end=\"6492\">\n<li data-section-id=\"1l2n9ej\" data-start=\"6399\" data-end=\"6418\">Manually operated<\/li>\n<li data-section-id=\"1dilsg\" data-start=\"6419\" data-end=\"6443\">Pneumatically operated<\/li>\n<li data-section-id=\"105o0xl\" data-start=\"6444\" data-end=\"6468\">Hydraulically operated<\/li>\n<li data-section-id=\"1y4gafj\" data-start=\"6469\" data-end=\"6492\">Electrically operated<\/li>\n<\/ul>\n<p data-start=\"6494\" data-end=\"6712\">The standard covers nominal pressure designations up to and including <strong data-start=\"6564\" data-end=\"6587\">4 MPa and Class 300<\/strong> and nominal sizes <strong data-start=\"6606\" data-end=\"6626\">DN 40 to DN 2000<\/strong>, subject to the standard&#8217;s detailed provisions.<\/p>\n<hr data-start=\"6714\" data-end=\"6717\" \/>\n<h1 data-section-id=\"1ud7n4i\" data-start=\"6719\" data-end=\"6737\">Products Covered<\/h1>\n<p data-start=\"6739\" data-end=\"6830\">Depending upon the applicable standard and licence scope, the product category may include:<\/p>\n<h3 data-section-id=\"iba07p\" data-start=\"6832\" data-end=\"6867\">Double-Flanged Butterfly Valves<\/h3>\n<p data-start=\"6869\" data-end=\"6927\">Butterfly valves having flanged connections on both sides.<\/p>\n<h3 data-section-id=\"185w10p\" data-start=\"6929\" data-end=\"6955\">Wafer Butterfly Valves<\/h3>\n<p data-start=\"6957\" data-end=\"7010\">Valves designed to be installed between pipe flanges.<\/p>\n<h3 data-section-id=\"19cyu4w\" data-start=\"7012\" data-end=\"7045\">Metal-Seated Butterfly Valves<\/h3>\n<p data-start=\"7047\" data-end=\"7100\">Butterfly valves using metallic seating arrangements.<\/p>\n<h3 data-section-id=\"18znu9i\" data-start=\"7102\" data-end=\"7139\">Resilient-Seated Butterfly Valves<\/h3>\n<p data-start=\"7141\" data-end=\"7190\">Valves incorporating resilient seating materials.<\/p>\n<h3 data-section-id=\"fqnu9w\" data-start=\"7192\" data-end=\"7218\">Lined Butterfly Valves<\/h3>\n<p data-start=\"7220\" data-end=\"7292\">Butterfly valves incorporating lining suitable for the intended service.<\/p>\n<h3 data-section-id=\"6rvsoj\" data-start=\"7294\" data-end=\"7330\">Different Operating Arrangements<\/h3>\n<ul data-start=\"7332\" data-end=\"7375\">\n<li data-section-id=\"1tkp1zm\" data-start=\"7332\" data-end=\"7340\">Manual<\/li>\n<li data-section-id=\"10wk6ok\" data-start=\"7341\" data-end=\"7352\">Pneumatic<\/li>\n<li data-section-id=\"4ytixp\" data-start=\"7353\" data-end=\"7364\">Hydraulic<\/li>\n<li data-section-id=\"8w94bv\" data-start=\"7365\" data-end=\"7375\">Electric<\/li>\n<\/ul>\n<p data-start=\"7377\" data-end=\"7503\">The exact product scope should be finalized according to the applicable BIS standard, product design and licence requirements.<\/p>\n<hr data-start=\"7505\" data-end=\"7508\" \/>\n<h1 data-section-id=\"1pgearx\" data-start=\"7510\" data-end=\"7565\">IS 13095:1991 and Current Revision \u2013 Important Update<\/h1>\n<p data-start=\"7567\" data-end=\"7633\">This section is <strong data-start=\"7583\" data-end=\"7632\">very important for SEO and technical accuracy<\/strong>.<\/p>\n<p data-start=\"7635\" data-end=\"7918\">Although the requested product page is based on <strong data-start=\"7683\" data-end=\"7700\">IS 13095:1991<\/strong>, BIS has subsequently issued <strong data-start=\"7730\" data-end=\"7804\">IS 13095:2020 \u2013 Butterfly Valves for General Purposes (First Revision)<\/strong>. BIS&#8217;s later product manual provides licence scope under the 2020 revision.<\/p>\n<p data-start=\"7920\" data-end=\"7981\">The 2020 revision&#8217;s product scope includes materials such as:<\/p>\n<ul data-start=\"7983\" data-end=\"8054\">\n<li data-section-id=\"bqmyl3\" data-start=\"7983\" data-end=\"7994\">Cast iron<\/li>\n<li data-section-id=\"1y7y6wk\" data-start=\"7995\" data-end=\"8009\">Ductile iron<\/li>\n<li data-section-id=\"1gs0y5s\" data-start=\"8010\" data-end=\"8024\">Carbon steel<\/li>\n<li data-section-id=\"18g4t1n\" data-start=\"8025\" data-end=\"8042\">Stainless steel<\/li>\n<li data-section-id=\"fto2i3\" data-start=\"8043\" data-end=\"8054\">Aluminium<\/li>\n<\/ul>\n<p data-start=\"8056\" data-end=\"8106\">It also identifies service applications including:<\/p>\n<ul data-start=\"8108\" data-end=\"8170\">\n<li data-section-id=\"ln31w6\" data-start=\"8108\" data-end=\"8124\">Tight shut-off<\/li>\n<li data-section-id=\"nqo2gk\" data-start=\"8125\" data-end=\"8137\">Regulating<\/li>\n<li data-section-id=\"1h8bg8s\" data-start=\"8138\" data-end=\"8151\">Low leakage<\/li>\n<li data-section-id=\"ts1ate\" data-start=\"8152\" data-end=\"8170\">Vacuum condition<\/li>\n<\/ul>\n<p data-start=\"8172\" data-end=\"8347\">and nominal sizes from <strong data-start=\"8195\" data-end=\"8209\">40 to 2000<\/strong>, nominal pressures from <strong data-start=\"8234\" data-end=\"8255\">PN 0.25 to PN 4.0<\/strong>, and Class 125, Class 150 and Class 300 designations.<\/p>\n<p data-start=\"8349\" data-end=\"8554\">Therefore, a manufacturer should <strong data-start=\"8382\" data-end=\"8475\">not automatically assume that IS 13095:1991 is the correct standard for a new application<\/strong>. Product applicability should be verified against the latest BIS requirements.<\/p>\n<hr data-start=\"8556\" data-end=\"8559\" \/>\n<h1 data-section-id=\"cm6iln\" data-start=\"8561\" data-end=\"8598\">Enforcement \/ Implementation Status<\/h1>\n<p data-start=\"8600\" data-end=\"8738\">For a website article, avoid publishing an unsupported statement such as \u201cIS 13095:1991 is currently mandatory for every butterfly valve.\u201d<\/p>\n<p data-start=\"8740\" data-end=\"8766\">The BIS records show that:<\/p>\n<ul data-start=\"8768\" data-end=\"9037\">\n<li data-section-id=\"d6l816\" data-start=\"8768\" data-end=\"8809\">IS 13095:1991 has a BIS Product Manual.<\/li>\n<li data-section-id=\"1m6h3z3\" data-start=\"8810\" data-end=\"8876\">BIS LIMS continues to show testing facilities for IS 13095:1991.<\/li>\n<li data-section-id=\"m02lvm\" data-start=\"8877\" data-end=\"8930\">BIS also lists IS 13095:2020 as the first revision.<\/li>\n<li data-section-id=\"qrccwx\" data-start=\"8931\" data-end=\"9037\">Amendment No. 2 to IS 13095:2020 was published in February 2025.<\/li>\n<\/ul>\n<p data-start=\"9039\" data-end=\"9071\"><strong data-start=\"9039\" data-end=\"9071\">Recommended website wording:<\/strong><\/p>\n<blockquote data-start=\"9073\" data-end=\"9300\">\n<p data-start=\"9075\" data-end=\"9300\">\u201cManufacturers should verify the latest BIS notification, certification scheme and applicable Indian Standard before applying for certification, particularly because IS 13095:2020 is the subsequent revision of IS 13095:1991.\u201d<\/p>\n<\/blockquote>\n<p data-start=\"9302\" data-end=\"9385\">This wording is safer and more accurate for a professional BIS consultancy website.<\/p>\n<hr data-start=\"9387\" data-end=\"9390\" \/>\n<h1 data-section-id=\"12jv47o\" data-start=\"9392\" data-end=\"9416\">Applicable QCO Details<\/h1>\n<p data-start=\"9418\" data-end=\"9581\">Before publishing a definitive QCO statement for this product, the manufacturer&#8217;s exact product category and latest BIS regulatory notification should be verified.<\/p>\n<p data-start=\"9583\" data-end=\"9657\">For BIS certification purposes, the applicable requirements may depend on:<\/p>\n<ul data-start=\"9659\" data-end=\"9843\">\n<li data-section-id=\"1stkp7f\" data-start=\"9659\" data-end=\"9673\">Product type<\/li>\n<li data-section-id=\"v2almr\" data-start=\"9674\" data-end=\"9684\">Material<\/li>\n<li data-section-id=\"fgz13f\" data-start=\"9685\" data-end=\"9699\">Nominal size<\/li>\n<li data-section-id=\"fhz65e\" data-start=\"9700\" data-end=\"9722\">Pressure designation<\/li>\n<li data-section-id=\"nb0hox\" data-start=\"9723\" data-end=\"9739\">End connection<\/li>\n<li data-section-id=\"1imlt9r\" data-start=\"9740\" data-end=\"9761\">Service application<\/li>\n<li data-section-id=\"e6kycu\" data-start=\"9762\" data-end=\"9783\">Operating mechanism<\/li>\n<li data-section-id=\"1ucp8qq\" data-start=\"9784\" data-end=\"9806\">Current BIS standard<\/li>\n<li data-section-id=\"1o8gvf4\" data-start=\"9807\" data-end=\"9843\">Applicable regulatory notification<\/li>\n<\/ul>\n<p data-start=\"9845\" data-end=\"9945\"><strong data-start=\"9845\" data-end=\"9945\">Qualitance India can perform a product applicability assessment before the application is filed.<\/strong><\/p>\n<hr data-start=\"9947\" data-end=\"9950\" \/>\n<h1 data-section-id=\"2uzze8\" data-start=\"9952\" data-end=\"9982\">Who Needs BIS Certification?<\/h1>\n<p data-start=\"9984\" data-end=\"10023\">The relevant manufacturers may include:<\/p>\n<ul data-start=\"10025\" data-end=\"10376\">\n<li data-section-id=\"11otkgn\" data-start=\"10025\" data-end=\"10056\">Butterfly valve manufacturers<\/li>\n<li data-section-id=\"rsic0z\" data-start=\"10057\" data-end=\"10089\">Industrial valve manufacturers<\/li>\n<li data-section-id=\"1l979mu\" data-start=\"10090\" data-end=\"10120\">Pipeline valve manufacturers<\/li>\n<li data-section-id=\"1vvm0bc\" data-start=\"10121\" data-end=\"10158\">Water-treatment valve manufacturers<\/li>\n<li data-section-id=\"ujllw8\" data-start=\"10159\" data-end=\"10185\">HVAC valve manufacturers<\/li>\n<li data-section-id=\"hmflko\" data-start=\"10186\" data-end=\"10224\">Process-industry valve manufacturers<\/li>\n<li data-section-id=\"1ksac4b\" data-start=\"10225\" data-end=\"10256\">Cast iron valve manufacturers<\/li>\n<li data-section-id=\"4tvirc\" data-start=\"10257\" data-end=\"10291\">Ductile iron valve manufacturers<\/li>\n<li data-section-id=\"17dmpo\" data-start=\"10292\" data-end=\"10326\">Carbon steel valve manufacturers<\/li>\n<li data-section-id=\"15nsph9\" data-start=\"10327\" data-end=\"10376\">Valve manufacturers supplying regulated markets<\/li>\n<\/ul>\n<p data-start=\"10378\" data-end=\"10516\">Foreign manufacturers supplying products into India may also need to evaluate the applicable BIS foreign-manufacturer certification route.<\/p>\n<hr data-start=\"10518\" data-end=\"10521\" \/>\n<h1 data-section-id=\"1wrw5ko\" data-start=\"10523\" data-end=\"10545\">Eligibility Criteria<\/h1>\n<p data-start=\"10547\" data-end=\"10610\">A manufacturer seeking BIS certification should generally have:<\/p>\n<ul data-start=\"10612\" data-end=\"10991\">\n<li data-section-id=\"k244lq\" data-start=\"10612\" data-end=\"10636\">Manufacturing premises<\/li>\n<li data-section-id=\"1snwsnz\" data-start=\"10637\" data-end=\"10677\">Suitable valve manufacturing machinery<\/li>\n<li data-section-id=\"zjlmnv\" data-start=\"10678\" data-end=\"10722\">Testing facilities or testing arrangements<\/li>\n<li data-section-id=\"pwhw22\" data-start=\"10723\" data-end=\"10747\">Quality-control system<\/li>\n<li data-section-id=\"dcf414\" data-start=\"10748\" data-end=\"10777\">Trained technical personnel<\/li>\n<li data-section-id=\"m8bl2o\" data-start=\"10778\" data-end=\"10812\">Calibrated measuring instruments<\/li>\n<li data-section-id=\"p4vzjy\" data-start=\"10813\" data-end=\"10836\">Raw-material controls<\/li>\n<li data-section-id=\"6l58qf\" data-start=\"10837\" data-end=\"10869\">Manufacturing process controls<\/li>\n<li data-section-id=\"1t9gfqt\" data-start=\"10870\" data-end=\"10893\">Inspection facilities<\/li>\n<li data-section-id=\"ym346k\" data-start=\"10894\" data-end=\"10925\">Product identification system<\/li>\n<li data-section-id=\"x92i00\" data-start=\"10926\" data-end=\"10940\">Test records<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"10941\" data-end=\"10961\">Production records<\/li>\n<li data-section-id=\"1ax674z\" data-start=\"10962\" data-end=\"10991\">Suitable storage facilities<\/li>\n<\/ul>\n<p data-start=\"10993\" data-end=\"11079\">The exact requirements depend on the applicable BIS certification scheme and standard.<\/p>\n<hr data-start=\"11081\" data-end=\"11084\" \/>\n<h1 data-section-id=\"3hamjo\" data-start=\"11086\" data-end=\"11122\">Complete BIS Certification Process<\/h1>\n<h2 data-section-id=\"5ubjzc\" data-start=\"11124\" data-end=\"11154\">Step 1 \u2013 Product Assessment<\/h2>\n<p data-start=\"11156\" data-end=\"11228\">First, identify the exact butterfly valve manufactured by the applicant.<\/p>\n<h2 data-section-id=\"1c0g148\" data-start=\"11230\" data-end=\"11264\">Step 2 \u2013 Standard Applicability<\/h2>\n<p data-start=\"11266\" data-end=\"11387\">Determine whether the product should be assessed against <strong data-start=\"11323\" data-end=\"11386\">IS 13095:1991, IS 13095:2020 or another applicable standard<\/strong>.<\/p>\n<h2 data-section-id=\"wc00dc\" data-start=\"11389\" data-end=\"11425\">Step 3 \u2013 Product Scope Assessment<\/h2>\n<p data-start=\"11427\" data-end=\"11436\">Identify:<\/p>\n<ul data-start=\"11438\" data-end=\"11566\">\n<li data-section-id=\"1l397p4\" data-start=\"11438\" data-end=\"11450\">Valve type<\/li>\n<li data-section-id=\"v2almr\" data-start=\"11451\" data-end=\"11461\">Material<\/li>\n<li data-section-id=\"fgz13f\" data-start=\"11462\" data-end=\"11476\">Nominal size<\/li>\n<li data-section-id=\"146ujl7\" data-start=\"11477\" data-end=\"11495\">Nominal pressure<\/li>\n<li data-section-id=\"638cmh\" data-start=\"11496\" data-end=\"11515\">Class designation<\/li>\n<li data-section-id=\"nb0hox\" data-start=\"11516\" data-end=\"11532\">End connection<\/li>\n<li data-section-id=\"1imlt9r\" data-start=\"11533\" data-end=\"11554\">Service application<\/li>\n<li data-section-id=\"1dpaqql\" data-start=\"11555\" data-end=\"11566\">Operation<\/li>\n<\/ul>\n<h2 data-section-id=\"btt0s2\" data-start=\"11568\" data-end=\"11598\">Step 4 \u2013 Factory Assessment<\/h2>\n<p data-start=\"11600\" data-end=\"11699\">Evaluate the manufacturing facility, machinery, testing equipment and quality-control arrangements.<\/p>\n<h2 data-section-id=\"16mjvk3\" data-start=\"11701\" data-end=\"11726\">Step 5 \u2013 Documentation<\/h2>\n<p data-start=\"11728\" data-end=\"11770\">Prepare the BIS application documentation.<\/p>\n<h2 data-section-id=\"1t4bp2l\" data-start=\"11772\" data-end=\"11802\">Step 6 \u2013 Sample Preparation<\/h2>\n<p data-start=\"11804\" data-end=\"11874\">Prepare the representative valve\/sample according to BIS requirements.<\/p>\n<h2 data-section-id=\"1bh4pl2\" data-start=\"11876\" data-end=\"11906\">Step 7 \u2013 Laboratory Testing<\/h2>\n<p data-start=\"11908\" data-end=\"11967\">Testing is carried out against the applicable requirements.<\/p>\n<h2 data-section-id=\"pat1r2\" data-start=\"11969\" data-end=\"11996\">Step 8 \u2013 BIS Application<\/h2>\n<p data-start=\"11998\" data-end=\"12083\">Submit the application and supporting documents through the applicable BIS procedure.<\/p>\n<h2 data-section-id=\"1l6b2e2\" data-start=\"12085\" data-end=\"12117\">Step 9 \u2013 Application Scrutiny<\/h2>\n<p data-start=\"12119\" data-end=\"12173\">BIS reviews the application and technical information.<\/p>\n<h2 data-section-id=\"80dr\" data-start=\"12175\" data-end=\"12206\">Step 10 \u2013 Factory Inspection<\/h2>\n<p data-start=\"12208\" data-end=\"12274\">BIS may assess the manufacturing facility and production controls.<\/p>\n<h2 data-section-id=\"4mmf4d\" data-start=\"12276\" data-end=\"12311\">Step 11 \u2013 Testing &amp; Verification<\/h2>\n<p data-start=\"12313\" data-end=\"12382\">Product testing and factory verification are completed as applicable.<\/p>\n<h2 data-section-id=\"mrnmic\" data-start=\"12384\" data-end=\"12416\">Step 12 \u2013 Observation Closure<\/h2>\n<p data-start=\"12418\" data-end=\"12469\">Any observations or non-conformities are addressed.<\/p>\n<h2 data-section-id=\"1ej0yr\" data-start=\"12471\" data-end=\"12497\">Step 13 \u2013 Licence Grant<\/h2>\n<p data-start=\"12499\" data-end=\"12587\">After satisfactory completion of the applicable requirements, BIS may grant the licence.<\/p>\n<h2 data-section-id=\"1liwrfe\" data-start=\"12589\" data-end=\"12621\">Step 14 \u2013 ISI Mark Compliance<\/h2>\n<p data-start=\"12623\" data-end=\"12703\">The manufacturer uses the BIS Standard Mark according to the licence conditions.<\/p>\n<h2 data-section-id=\"z9jsz8\" data-start=\"12705\" data-end=\"12736\">Step 15 \u2013 Ongoing Compliance<\/h2>\n<p data-start=\"12738\" data-end=\"12810\">The manufacturer continues to maintain quality and testing requirements.<\/p>\n<hr data-start=\"12812\" data-end=\"12815\" \/>\n<h1 data-section-id=\"183y3g3\" data-start=\"12817\" data-end=\"12837\">Required Documents<\/h1>\n<p data-start=\"12839\" data-end=\"12873\">Typical documentation may include:<\/p>\n<ul data-start=\"12875\" data-end=\"13413\">\n<li data-section-id=\"laj0jm\" data-start=\"12875\" data-end=\"12907\">Company registration documents<\/li>\n<li data-section-id=\"1b2i29\" data-start=\"12908\" data-end=\"12940\">Factory registration documents<\/li>\n<li data-section-id=\"a8o83y\" data-start=\"12941\" data-end=\"12964\">Factory address proof<\/li>\n<li data-section-id=\"17ibqzq\" data-start=\"12965\" data-end=\"12981\">Factory layout<\/li>\n<li data-section-id=\"2qrcjh\" data-start=\"12982\" data-end=\"13016\">Manufacturing process flow chart<\/li>\n<li data-section-id=\"ef1hg\" data-start=\"13017\" data-end=\"13033\">Machinery list<\/li>\n<li data-section-id=\"1fo8gvq\" data-start=\"13034\" data-end=\"13058\">Testing equipment list<\/li>\n<li data-section-id=\"1ymt51g\" data-start=\"13059\" data-end=\"13085\">Calibration certificates<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"13086\" data-end=\"13104\">Product drawings<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"13105\" data-end=\"13129\">Product specifications<\/li>\n<li data-section-id=\"1gfhsh8\" data-start=\"13130\" data-end=\"13148\">Valve datasheets<\/li>\n<li data-section-id=\"cjqh7s\" data-start=\"13149\" data-end=\"13171\">Raw-material details<\/li>\n<li data-section-id=\"zib2zp\" data-start=\"13172\" data-end=\"13195\">Material certificates<\/li>\n<li data-section-id=\"ku0u1o\" data-start=\"13196\" data-end=\"13218\">Quality-control plan<\/li>\n<li data-section-id=\"16dybms\" data-start=\"13219\" data-end=\"13242\">Internal test reports<\/li>\n<li data-section-id=\"684x8w\" data-start=\"13243\" data-end=\"13264\">Product photographs<\/li>\n<li data-section-id=\"74k6c5\" data-start=\"13265\" data-end=\"13284\">Packaging details<\/li>\n<li data-section-id=\"1hcgcf\" data-start=\"13285\" data-end=\"13302\">Marking details<\/li>\n<li data-section-id=\"dk8bdz\" data-start=\"13303\" data-end=\"13324\">Trademark documents<\/li>\n<li data-section-id=\"1gg3gcx\" data-start=\"13325\" data-end=\"13357\">Authorized signatory documents<\/li>\n<li data-section-id=\"ghz2vj\" data-start=\"13358\" data-end=\"13381\">BIS application forms<\/li>\n<li data-section-id=\"1tblks5\" data-start=\"13382\" data-end=\"13413\">Declarations and undertakings<\/li>\n<\/ul>\n<p data-start=\"13415\" data-end=\"13523\">The final document list should be prepared according to the applicable BIS standard and certification route.<\/p>\n<hr data-start=\"13525\" data-end=\"13528\" \/>\n<h1 data-section-id=\"1dr8hy4\" data-start=\"13530\" data-end=\"13552\">Testing Requirements<\/h1>\n<p data-start=\"13554\" data-end=\"13754\">BIS LIMS currently provides testing information for <strong data-start=\"13606\" data-end=\"13623\">IS 13095:1991<\/strong>. The listed test areas include several important performance and dimensional requirements.<\/p>\n<p data-start=\"13756\" data-end=\"13788\">Important testing areas include:<\/p>\n<h3 data-section-id=\"xhtipw\" data-start=\"13790\" data-end=\"13815\">Valve End Connections<\/h3>\n<p data-start=\"13817\" data-end=\"13876\">Verification of the applicable end connection requirements.<\/p>\n<h3 data-section-id=\"e5zi7m\" data-start=\"13878\" data-end=\"13902\">Service Applications<\/h3>\n<p data-start=\"13904\" data-end=\"13962\">Assessment according to the specified service application.<\/p>\n<h3 data-section-id=\"xb16ae\" data-start=\"13964\" data-end=\"13981\">Nominal Sizes<\/h3>\n<p data-start=\"13983\" data-end=\"14030\">Verification of applicable nominal valve sizes.<\/p>\n<h3 data-section-id=\"tbdmat\" data-start=\"14032\" data-end=\"14052\">Nominal Pressure<\/h3>\n<p data-start=\"14054\" data-end=\"14091\">Verification of pressure designation.<\/p>\n<h3 data-section-id=\"1v7oron\" data-start=\"14093\" data-end=\"14114\">Class Designation<\/h3>\n<p data-start=\"14116\" data-end=\"14158\">Applicable class designation requirements.<\/p>\n<h3 data-section-id=\"47wcu6\" data-start=\"14160\" data-end=\"14187\">Face-to-Face Dimensions<\/h3>\n<p data-start=\"14189\" data-end=\"14225\">Verification of required dimensions.<\/p>\n<h3 data-section-id=\"fgt34g\" data-start=\"14227\" data-end=\"14237\">Bodies<\/h3>\n<p data-start=\"14239\" data-end=\"14277\">Evaluation of valve body requirements.<\/p>\n<h3 data-section-id=\"zx9vug\" data-start=\"14279\" data-end=\"14297\">Disc and Shaft<\/h3>\n<p data-start=\"14299\" data-end=\"14341\">Assessment of disc and shaft requirements.<\/p>\n<h3 data-section-id=\"1f9sara\" data-start=\"14343\" data-end=\"14366\">Seating and Linings<\/h3>\n<p data-start=\"14368\" data-end=\"14416\">Verification of seating and lining requirements.<\/p>\n<h3 data-section-id=\"1uie7i9\" data-start=\"14418\" data-end=\"14430\">Bearings<\/h3>\n<p data-start=\"14432\" data-end=\"14478\">Applicable bearing requirements are evaluated.<\/p>\n<h3 data-section-id=\"bjb1kj\" data-start=\"14480\" data-end=\"14493\">Operation<\/h3>\n<p data-start=\"14495\" data-end=\"14529\">Operation of the valve is checked.<\/p>\n<h3 data-section-id=\"1nubl4\" data-start=\"14531\" data-end=\"14554\">Performance Testing<\/h3>\n<p data-start=\"14556\" data-end=\"14636\">Performance testing is an important part of the applicable product requirements.<\/p>\n<h3 data-section-id=\"sgdr28\" data-start=\"14638\" data-end=\"14651\">Body Test<\/h3>\n<p data-start=\"14653\" data-end=\"14717\">The valve body is subjected to the applicable test requirements.<\/p>\n<h3 data-section-id=\"7gu7sj\" data-start=\"14719\" data-end=\"14732\">Seat Test<\/h3>\n<p data-start=\"14734\" data-end=\"14786\">Seat leakage\/performance requirements are evaluated.<\/p>\n<h3 data-section-id=\"1jbq31k\" data-start=\"14788\" data-end=\"14810\">Disc Strength Test<\/h3>\n<p data-start=\"14812\" data-end=\"14879\">Disc strength is evaluated according to the applicable requirement.<\/p>\n<p data-start=\"14881\" data-end=\"15060\">BIS LIMS specifically lists <strong data-start=\"14909\" data-end=\"14977\">performance testing, body test, seat test and disc strength test<\/strong> among the testing scope for IS 13095:1991.<\/p>\n<hr data-start=\"15062\" data-end=\"15065\" \/>\n<h1 data-section-id=\"19ixn4b\" data-start=\"15067\" data-end=\"15091\">BIS Testing Laboratory<\/h1>\n<p data-start=\"15093\" data-end=\"15174\">BIS LIMS currently lists laboratories having testing scope for <strong data-start=\"15156\" data-end=\"15173\">IS 13095:1991<\/strong>.<\/p>\n<p data-start=\"15176\" data-end=\"15334\">For example, BIS LIMS shows testing facilities for this standard at <strong data-start=\"15244\" data-end=\"15270\">BIS Central Laboratory<\/strong> and other laboratories.<\/p>\n<p data-start=\"15336\" data-end=\"15376\">The current LIMS information also shows:<\/p>\n<ul data-start=\"15378\" data-end=\"15708\">\n<li data-section-id=\"18wz22x\" data-start=\"15378\" data-end=\"15531\">A listed testing charge of <strong data-start=\"15407\" data-end=\"15433\">\u20b93,300 excluding taxes<\/strong> for one IS 13095:1991 scope at certain listed facilities.<\/li>\n<li data-section-id=\"1vhg1cq\" data-start=\"15532\" data-end=\"15708\"><strong data-start=\"15534\" data-end=\"15559\">Unique Test House LLP<\/strong> lists IS 13095:1991 for butterfly valves up to 500 mm with a displayed charge of <strong data-start=\"15641\" data-end=\"15667\">\u20b94,500 excluding taxes<\/strong>.<\/li>\n<\/ul>\n<p data-start=\"15710\" data-end=\"15893\">These figures should <strong data-start=\"15731\" data-end=\"15785\">not be presented as the universal BIS testing cost<\/strong>, because laboratory charges can vary based on scope, exclusions, size, testing requirements and laboratory.<\/p>\n<hr data-start=\"15895\" data-end=\"15898\" \/>\n<h1 data-section-id=\"1jye7rh\" data-start=\"15900\" data-end=\"15924\">BIS Certification Cost<\/h1>\n<p data-start=\"15926\" data-end=\"15970\">The total BIS certification cost depends on:<\/p>\n<ul data-start=\"15972\" data-end=\"16213\">\n<li data-section-id=\"qbv4f3\" data-start=\"15972\" data-end=\"15994\">BIS application fees<\/li>\n<li data-section-id=\"xel55g\" data-start=\"15995\" data-end=\"16023\">Laboratory testing charges<\/li>\n<li data-section-id=\"1edb8s5\" data-start=\"16024\" data-end=\"16045\">Inspection expenses<\/li>\n<li data-section-id=\"860kvd\" data-start=\"16046\" data-end=\"16061\">Product scope<\/li>\n<li data-section-id=\"1rptq06\" data-start=\"16062\" data-end=\"16082\">Number of variants<\/li>\n<li data-section-id=\"117j9ee\" data-start=\"16083\" data-end=\"16096\">Valve sizes<\/li>\n<li data-section-id=\"p7x5p1\" data-start=\"16097\" data-end=\"16115\">Pressure classes<\/li>\n<li data-section-id=\"v2almr\" data-start=\"16116\" data-end=\"16126\">Material<\/li>\n<li data-section-id=\"10w0ysy\" data-start=\"16127\" data-end=\"16149\">Testing requirements<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"16150\" data-end=\"16165\">Documentation<\/li>\n<li data-section-id=\"1yxwnu5\" data-start=\"16166\" data-end=\"16191\">Retesting, if necessary<\/li>\n<li data-section-id=\"1q8f3t4\" data-start=\"16192\" data-end=\"16213\">Consultancy charges<\/li>\n<\/ul>\n<p data-start=\"16215\" data-end=\"16327\">Therefore, there is <strong data-start=\"16235\" data-end=\"16277\">no single fixed BIS certification cost<\/strong> applicable to every butterfly valve manufacturer.<\/p>\n<hr data-start=\"16329\" data-end=\"16332\" \/>\n<h1 data-section-id=\"18r0ejr\" data-start=\"16334\" data-end=\"16362\">Factory Inspection Process<\/h1>\n<p data-start=\"16364\" data-end=\"16411\">During the factory assessment, BIS may examine:<\/p>\n<h3 data-section-id=\"ihy9m0\" data-start=\"16413\" data-end=\"16440\">Manufacturing Machinery<\/h3>\n<p data-start=\"16442\" data-end=\"16504\">Valve body, disc, shaft and assembly manufacturing facilities.<\/p>\n<h3 data-section-id=\"vosynu\" data-start=\"16506\" data-end=\"16523\">Raw Materials<\/h3>\n<p data-start=\"16525\" data-end=\"16578\">Incoming material identification and quality control.<\/p>\n<h3 data-section-id=\"5sl7zi\" data-start=\"16580\" data-end=\"16602\">Production Process<\/h3>\n<p data-start=\"16604\" data-end=\"16640\">Manufacturing and assembly controls.<\/p>\n<h3 data-section-id=\"1y0dmwj\" data-start=\"16642\" data-end=\"16664\">Testing Facilities<\/h3>\n<p data-start=\"16666\" data-end=\"16723\">Availability of required testing and measuring equipment.<\/p>\n<h3 data-section-id=\"wzkpnw\" data-start=\"16725\" data-end=\"16740\">Calibration<\/h3>\n<p data-start=\"16742\" data-end=\"16785\">Calibration status of relevant instruments.<\/p>\n<h3 data-section-id=\"l6hv9v\" data-start=\"16787\" data-end=\"16809\">Product Inspection<\/h3>\n<p data-start=\"16811\" data-end=\"16851\">Inspection of finished butterfly valves.<\/p>\n<h3 data-section-id=\"1kypjpx\" data-start=\"16853\" data-end=\"16872\">Quality Records<\/h3>\n<p data-start=\"16874\" data-end=\"16905\">Production and testing records.<\/p>\n<h3 data-section-id=\"1oz01yd\" data-start=\"16907\" data-end=\"16923\">Traceability<\/h3>\n<p data-start=\"16925\" data-end=\"16979\">Identification of raw materials and finished products.<\/p>\n<h3 data-section-id=\"1l1laoj\" data-start=\"16981\" data-end=\"16992\">Marking<\/h3>\n<p data-start=\"16994\" data-end=\"17045\">Product marking and BIS Standard Mark arrangements.<\/p>\n<hr data-start=\"17047\" data-end=\"17050\" \/>\n<h1 data-section-id=\"p8zpte\" data-start=\"17052\" data-end=\"17103\">Common Reasons for Application Rejection or Delay<\/h1>\n<ul data-start=\"17105\" data-end=\"17586\">\n<li data-section-id=\"1yswlkp\" data-start=\"17105\" data-end=\"17130\">Wrong standard selected<\/li>\n<li data-section-id=\"qnzs1c\" data-start=\"17131\" data-end=\"17156\">Incorrect product scope<\/li>\n<li data-section-id=\"1gg5wq7\" data-start=\"17157\" data-end=\"17189\">Incorrect valve classification<\/li>\n<li data-section-id=\"bvdcok\" data-start=\"17190\" data-end=\"17216\">Incomplete documentation<\/li>\n<li data-section-id=\"k408p1\" data-start=\"17217\" data-end=\"17242\">Failed performance test<\/li>\n<li data-section-id=\"1wve1bh\" data-start=\"17243\" data-end=\"17261\">Failed body test<\/li>\n<li data-section-id=\"15p3vdq\" data-start=\"17262\" data-end=\"17280\">Failed seat test<\/li>\n<li data-section-id=\"fc6ww2\" data-start=\"17281\" data-end=\"17311\">Disc strength non-conformity<\/li>\n<li data-section-id=\"1tyl2ef\" data-start=\"17312\" data-end=\"17340\">Dimensional non-conformity<\/li>\n<li data-section-id=\"xcvj8b\" data-start=\"17341\" data-end=\"17373\">Incorrect pressure designation<\/li>\n<li data-section-id=\"ovpwef\" data-start=\"17374\" data-end=\"17404\">Inadequate testing equipment<\/li>\n<li data-section-id=\"165gqyi\" data-start=\"17405\" data-end=\"17427\">Calibration problems<\/li>\n<li data-section-id=\"1k944kv\" data-start=\"17428\" data-end=\"17455\">Poor raw-material control<\/li>\n<li data-section-id=\"12u41ty\" data-start=\"17456\" data-end=\"17487\">Incomplete inspection records<\/li>\n<li data-section-id=\"fsvgb3\" data-start=\"17488\" data-end=\"17515\">Incorrect product marking<\/li>\n<li data-section-id=\"1pruwyv\" data-start=\"17516\" data-end=\"17550\">Factory not ready for inspection<\/li>\n<li data-section-id=\"ydlmj0\" data-start=\"17551\" data-end=\"17586\">Failure to close BIS observations<\/li>\n<\/ul>\n<hr data-start=\"17588\" data-end=\"17591\" \/>\n<h1 data-section-id=\"1evq9p\" data-start=\"17593\" data-end=\"17603\">Timeline<\/h1>\n<p data-start=\"17605\" data-end=\"17643\">The certification timeline depends on:<\/p>\n<ul data-start=\"17645\" data-end=\"17817\">\n<li data-section-id=\"r86jf7\" data-start=\"17645\" data-end=\"17664\">Product readiness<\/li>\n<li data-section-id=\"1213b4c\" data-start=\"17665\" data-end=\"17684\">Factory readiness<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"17685\" data-end=\"17700\">Documentation<\/li>\n<li data-section-id=\"1n720d6\" data-start=\"17701\" data-end=\"17726\">Laboratory availability<\/li>\n<li data-section-id=\"2xn0ck\" data-start=\"17727\" data-end=\"17744\">Testing results<\/li>\n<li data-section-id=\"czyv2v\" data-start=\"17745\" data-end=\"17771\">BIS application scrutiny<\/li>\n<li data-section-id=\"131dffa\" data-start=\"17772\" data-end=\"17795\">Inspection scheduling<\/li>\n<li data-section-id=\"2xyyqj\" data-start=\"17796\" data-end=\"17817\">Observation closure<\/li>\n<\/ul>\n<p data-start=\"17819\" data-end=\"17934\">Therefore, manufacturers should obtain a product-specific assessment before committing to a certification timeline.<\/p>\n<hr data-start=\"17936\" data-end=\"17939\" \/>\n<h1 data-section-id=\"wv2e8b\" data-start=\"17941\" data-end=\"17972\">Benefits of BIS Certification<\/h1>\n<h3 data-section-id=\"15cgiwz\" data-start=\"17974\" data-end=\"17999\">Regulatory Compliance<\/h3>\n<p data-start=\"18001\" data-end=\"18054\">Supports compliance with applicable BIS requirements.<\/p>\n<h3 data-section-id=\"1s6jna8\" data-start=\"18056\" data-end=\"18075\">Product Quality<\/h3>\n<p data-start=\"18077\" data-end=\"18129\">Helps establish systematic product-quality controls.<\/p>\n<h3 data-section-id=\"k08kti\" data-start=\"18131\" data-end=\"18154\">Customer Confidence<\/h3>\n<p data-start=\"18156\" data-end=\"18225\">Improves confidence among industrial customers and procurement teams.<\/p>\n<h3 data-section-id=\"s62ca3\" data-start=\"18227\" data-end=\"18248\">Market Acceptance<\/h3>\n<p data-start=\"18250\" data-end=\"18310\">Supports access to markets where BIS compliance is required.<\/p>\n<h3 data-section-id=\"dqc9ev\" data-start=\"18312\" data-end=\"18333\">Brand Credibility<\/h3>\n<p data-start=\"18335\" data-end=\"18424\">The BIS Standard Mark can strengthen product credibility when used under a valid licence.<\/p>\n<h3 data-section-id=\"gr3tzg\" data-start=\"18426\" data-end=\"18445\">Quality Control<\/h3>\n<p data-start=\"18447\" data-end=\"18503\">Encourages documented inspection and testing procedures.<\/p>\n<hr data-start=\"18505\" data-end=\"18508\" \/>\n<h1 data-section-id=\"18jhjpw\" data-start=\"18510\" data-end=\"18540\">Why Choose Qualitance India?<\/h1>\n<p data-start=\"18542\" data-end=\"18655\"><strong data-start=\"18542\" data-end=\"18562\">Qualitance India<\/strong> provides professional BIS Certification Consultancy for industrial and engineering products.<\/p>\n<p data-start=\"18657\" data-end=\"18716\">For butterfly valve manufacturers, our support can include:<\/p>\n<p data-start=\"18718\" data-end=\"19141\">\u2713 Product Applicability Assessment<br data-start=\"18752\" data-end=\"18755\" \/>\u2713 IS 13095 Standard Assessment<br data-start=\"18785\" data-end=\"18788\" \/>\u2713 Current Revision Verification<br data-start=\"18819\" data-end=\"18822\" \/>\u2713 Product Scope Assessment<br data-start=\"18848\" data-end=\"18851\" \/>\u2713 Documentation Support<br data-start=\"18874\" data-end=\"18877\" \/>\u2713 Testing Laboratory Coordination<br data-start=\"18910\" data-end=\"18913\" \/>\u2713 Sample Preparation Guidance<br data-start=\"18942\" data-end=\"18945\" \/>\u2713 BIS Application Assistance<br data-start=\"18973\" data-end=\"18976\" \/>\u2713 Factory Inspection Preparation<br data-start=\"19008\" data-end=\"19011\" \/>\u2713 Quality-Control Documentation<br data-start=\"19042\" data-end=\"19045\" \/>\u2713 Observation Closure Support<br data-start=\"19074\" data-end=\"19077\" \/>\u2713 ISI Mark Guidance<br data-start=\"19096\" data-end=\"19099\" \/>\u2713 End-to-End BIS Certification Consultancy<\/p>\n<h3 data-section-id=\"16z2skw\" data-start=\"19143\" data-end=\"19171\">Contact Qualitance India<\/h3>\n<p data-start=\"19173\" data-end=\"19273\"><strong data-start=\"19173\" data-end=\"19183\">Phone:<\/strong> +91-9310-615-170<br data-start=\"19200\" data-end=\"19203\" \/><strong data-start=\"19203\" data-end=\"19213\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"19214\" data-end=\"19238\">info@qualitanceindia.com<\/a><br data-start=\"19238\" data-end=\"19241\" \/><strong data-start=\"19241\" data-end=\"19253\">Website:<\/strong> qualitanceindia.com<\/p>\n<p data-start=\"19275\" data-end=\"19330\"><strong data-start=\"19275\" data-end=\"19330\">QUALITANCE INDIA \u2013 IMPROVING QUALITY AND COMPETENCE<\/strong><\/p>\n<hr data-start=\"19332\" data-end=\"19335\" \/>\n<h1 data-section-id=\"y9bcby\" data-start=\"19337\" data-end=\"19376\">Step-by-Step Flow Chart \u2013 Text Format<\/h1>\n<p data-start=\"19378\" data-end=\"19888\"><strong data-start=\"19378\" data-end=\"19420\">Butterfly Valve Product Identification<\/strong><br data-start=\"19420\" data-end=\"19423\" \/>\u2193<br data-start=\"19424\" data-end=\"19427\" \/><strong data-start=\"19427\" data-end=\"19459\">Material &amp; Design Assessment<\/strong><br data-start=\"19459\" data-end=\"19462\" \/>\u2193<br data-start=\"19463\" data-end=\"19466\" \/><strong data-start=\"19466\" data-end=\"19505\">Applicable IS Standard Verification<\/strong><br data-start=\"19505\" data-end=\"19508\" \/>\u2193<br data-start=\"19509\" data-end=\"19512\" \/><strong data-start=\"19512\" data-end=\"19541\">IS 13095 Scope Assessment<\/strong><br data-start=\"19541\" data-end=\"19544\" \/>\u2193<br data-start=\"19545\" data-end=\"19548\" \/><strong data-start=\"19548\" data-end=\"19580\">Factory Readiness Assessment<\/strong><br data-start=\"19580\" data-end=\"19583\" \/>\u2193<br data-start=\"19584\" data-end=\"19587\" \/><strong data-start=\"19587\" data-end=\"19616\">Documentation Preparation<\/strong><br data-start=\"19616\" data-end=\"19619\" \/>\u2193<br data-start=\"19620\" data-end=\"19623\" \/><strong data-start=\"19623\" data-end=\"19645\">Sample Preparation<\/strong><br data-start=\"19645\" data-end=\"19648\" \/>\u2193<br data-start=\"19649\" data-end=\"19652\" \/><strong data-start=\"19652\" data-end=\"19674\">Laboratory Testing<\/strong><br data-start=\"19674\" data-end=\"19677\" \/>\u2193<br data-start=\"19678\" data-end=\"19681\" \/><strong data-start=\"19681\" data-end=\"19711\">BIS Application Submission<\/strong><br data-start=\"19711\" data-end=\"19714\" \/>\u2193<br data-start=\"19715\" data-end=\"19718\" \/><strong data-start=\"19718\" data-end=\"19742\">Application Scrutiny<\/strong><br data-start=\"19742\" data-end=\"19745\" \/>\u2193<br data-start=\"19746\" data-end=\"19749\" \/><strong data-start=\"19749\" data-end=\"19771\">Factory Inspection<\/strong><br data-start=\"19771\" data-end=\"19774\" \/>\u2193<br data-start=\"19775\" data-end=\"19778\" \/><strong data-start=\"19778\" data-end=\"19801\">Observation Closure<\/strong><br data-start=\"19801\" data-end=\"19804\" \/>\u2193<br data-start=\"19805\" data-end=\"19808\" \/><strong data-start=\"19808\" data-end=\"19829\">BIS Licence Grant<\/strong><br data-start=\"19829\" data-end=\"19832\" \/>\u2193<br data-start=\"19833\" data-end=\"19836\" \/><strong data-start=\"19836\" data-end=\"19859\">ISI Mark Compliance<\/strong><br data-start=\"19859\" data-end=\"19862\" \/>\u2193<br data-start=\"19863\" data-end=\"19866\" \/><strong data-start=\"19866\" data-end=\"19888\">Ongoing Compliance<\/strong><\/p>\n<hr data-start=\"19890\" data-end=\"19893\" \/>\n<h1 data-section-id=\"sukx0d\" data-start=\"19895\" data-end=\"19908\">25 SEO FAQs<\/h1>\n<h3 data-section-id=\"1qcm5s8\" data-start=\"19910\" data-end=\"19939\">1. What is IS 13095:1991?<\/h3>\n<p data-start=\"19941\" data-end=\"20069\">IS 13095:1991 is the Indian Standard titled <strong data-start=\"19985\" data-end=\"20029\">\u201cButterfly Valves for General Purposes.\u201d<\/strong><\/p>\n<h3 data-section-id=\"3ivbjv\" data-start=\"20071\" data-end=\"20124\">2. What products are covered under IS 13095:1991?<\/h3>\n<p data-start=\"20126\" data-end=\"20333\">The standard covers double-flanged and wafer-type metal-seated, resilient-seated cast iron, ductile iron, carbon steel and lined butterfly valves for general purposes.<\/p>\n<h3 data-section-id=\"1isbjqb\" data-start=\"20335\" data-end=\"20378\">3. What types of operation are covered?<\/h3>\n<p data-start=\"20380\" data-end=\"20512\">The standard covers manually, pneumatically, hydraulically and electrically operated valves.<\/p>\n<h3 data-section-id=\"1kbzoib\" data-start=\"20514\" data-end=\"20564\">4. What sizes are covered under IS 13095:1991?<\/h3>\n<p data-start=\"20566\" data-end=\"20713\">The original standard covers nominal sizes from <strong data-start=\"20614\" data-end=\"20634\">DN 40 to DN 2000<\/strong>, subject to its detailed requirements.<\/p>\n<h3 data-section-id=\"yvrero\" data-start=\"20715\" data-end=\"20753\">5. What pressure range is covered?<\/h3>\n<p data-start=\"20755\" data-end=\"20898\">The original standard covers nominal pressure designations up to and including <strong data-start=\"20834\" data-end=\"20857\">4 MPa and Class 300<\/strong>.<\/p>\n<h3 data-section-id=\"1h5wwkh\" data-start=\"20900\" data-end=\"20958\">6. Is BIS Certification required for butterfly valves?<\/h3>\n<p data-start=\"20960\" data-end=\"21123\">The requirement depends on the applicable regulatory framework and product category. Manufacturers should verify the current BIS\/QCO applicability before applying.<\/p>\n<h3 data-section-id=\"3teunn\" data-start=\"21125\" data-end=\"21175\">7. Is IS 13095:1991 still the latest standard?<\/h3>\n<p data-start=\"21177\" data-end=\"21327\">No. BIS has subsequently published <strong data-start=\"21212\" data-end=\"21286\">IS 13095:2020 \u2013 Butterfly Valves for General Purposes (First Revision)<\/strong>.<\/p>\n<h3 data-section-id=\"1b1sxs1\" data-start=\"21329\" data-end=\"21358\">8. What is IS 13095:2020?<\/h3>\n<p data-start=\"21360\" data-end=\"21528\">It is the first revision of the butterfly-valve standard and provides updated product requirements and licence-scope parameters.<\/p>\n<h3 data-section-id=\"15vzn3h\" data-start=\"21530\" data-end=\"21582\">9. What tests are required for butterfly valves?<\/h3>\n<p data-start=\"21584\" data-end=\"21780\">Testing can include dimensional checks, body testing, seat testing, performance testing and disc strength testing, along with other applicable requirements.<\/p>\n<h3 data-section-id=\"1r340ar\" data-start=\"21782\" data-end=\"21815\">10. Is body testing required?<\/h3>\n<p data-start=\"21817\" data-end=\"21930\">Yes, body testing is included in the BIS testing scope for IS 13095:1991.<\/p>\n<h3 data-section-id=\"r31dv5\" data-start=\"21932\" data-end=\"21965\">11. Is seat testing required?<\/h3>\n<p data-start=\"21967\" data-end=\"22069\">Yes, seat testing is included in the listed BIS testing scope.<\/p>\n<h3 data-section-id=\"nvrh7t\" data-start=\"22071\" data-end=\"22113\">12. Is disc strength testing required?<\/h3>\n<p data-start=\"22115\" data-end=\"22226\">Yes, disc strength testing is included in the applicable testing scope.<\/p>\n<h3 data-section-id=\"dg0go8\" data-start=\"22228\" data-end=\"22268\">13. Is performance testing required?<\/h3>\n<p data-start=\"22270\" data-end=\"22393\">Yes, performance testing is listed in the BIS LIMS testing scope for IS 13095:1991.<\/p>\n<h3 data-section-id=\"1qhkevq\" data-start=\"22395\" data-end=\"22449\">14. What sample is required for BIS certification?<\/h3>\n<p data-start=\"22451\" data-end=\"22575\">The BIS Product Manual for IS 13095:1991 specifies <strong data-start=\"22502\" data-end=\"22515\">one valve<\/strong> as the sample size.<\/p>\n<h3 data-section-id=\"1b8iybf\" data-start=\"22577\" data-end=\"22612\">15. What materials are covered?<\/h3>\n<p data-start=\"22614\" data-end=\"22761\">The 1991 standard covers cast iron, ductile iron and carbon steel valves and lined valves within its scope.<\/p>\n<h3 data-section-id=\"zwxy5f\" data-start=\"22763\" data-end=\"22803\">16. What are wafer butterfly valves?<\/h3>\n<p data-start=\"22805\" data-end=\"22885\">Wafer butterfly valves are designed to be accommodated between pipework flanges.<\/p>\n<h3 data-section-id=\"of06im\" data-start=\"22887\" data-end=\"22936\">17. What are double-flanged butterfly valves?<\/h3>\n<p data-start=\"22938\" data-end=\"23010\">These are butterfly valves having flanged end connections on both sides.<\/p>\n<h3 data-section-id=\"1p37bny\" data-start=\"23012\" data-end=\"23063\">18. What is BIS testing cost for IS 13095:1991?<\/h3>\n<p data-start=\"23065\" data-end=\"23271\">Current BIS LIMS listings show different charges depending on the laboratory and testing scope. For example, some listed scopes show \u20b93,300 or \u20b94,500 excluding taxes.<\/p>\n<h3 data-section-id=\"1nccose\" data-start=\"23273\" data-end=\"23342\">19. Is the laboratory charge the complete BIS certification cost?<\/h3>\n<p data-start=\"23344\" data-end=\"23467\">No. Testing is only one component. BIS application, inspection, documentation and other applicable expenses may also apply.<\/p>\n<h3 data-section-id=\"1xcb9gn\" data-start=\"23469\" data-end=\"23527\">20. What documents are required for BIS certification?<\/h3>\n<p data-start=\"23529\" data-end=\"23702\">Documents generally include factory details, manufacturing process, machinery, product specifications, testing facilities, calibration records and quality-control documents.<\/p>\n<h3 data-section-id=\"1usuu99\" data-start=\"23704\" data-end=\"23743\">21. Is factory inspection required?<\/h3>\n<p data-start=\"23745\" data-end=\"23820\">Factory assessment may be part of the applicable BIS certification process.<\/p>\n<h3 data-section-id=\"2fj7i6\" data-start=\"23822\" data-end=\"23881\">22. Can foreign manufacturers obtain BIS certification?<\/h3>\n<p data-start=\"23883\" data-end=\"23994\">Eligible foreign manufacturers can apply under the applicable BIS foreign-manufacturer certification framework.<\/p>\n<h3 data-section-id=\"1vpekvg\" data-start=\"23996\" data-end=\"24056\">23. Can one BIS licence cover all butterfly valve sizes?<\/h3>\n<p data-start=\"24058\" data-end=\"24224\">The licence scope depends on BIS grouping and the approved scope. Different sizes, pressure classes, materials and configurations may need to be specifically covered.<\/p>\n<h3 data-section-id=\"1p764xa\" data-start=\"24226\" data-end=\"24264\">24. What is the BIS Standard Mark?<\/h3>\n<p data-start=\"24266\" data-end=\"24368\">The BIS Standard Mark is used by a licensee according to the conditions of the applicable BIS licence.<\/p>\n<h3 data-section-id=\"19ozsjp\" data-start=\"24370\" data-end=\"24432\">25. Can Qualitance India help with IS 13095 certification?<\/h3>\n<p data-start=\"24434\" data-end=\"24582\">Yes. Qualitance India can support applicability assessment, documentation, testing coordination, BIS application and factory inspection preparation.<\/p>\n<hr data-start=\"24584\" data-end=\"24587\" \/>\n<h1 data-section-id=\"zvs7pk\" data-start=\"24589\" data-end=\"24609\">FAQ Schema Content<\/h1>\n<p data-start=\"24611\" data-end=\"24653\">Use these FAQs in the website FAQ section:<\/p>\n<ul data-start=\"24655\" data-end=\"25385\">\n<li data-section-id=\"10qlxcp\" data-start=\"24655\" data-end=\"24679\">What is IS 13095:1991?<\/li>\n<li data-section-id=\"atmc89\" data-start=\"24680\" data-end=\"24728\">What products are covered under IS 13095:1991?<\/li>\n<li data-section-id=\"ietbg7\" data-start=\"24729\" data-end=\"24782\">Is BIS Certification required for Butterfly Valves?<\/li>\n<li data-section-id=\"10poajd\" data-start=\"24783\" data-end=\"24807\">What is IS 13095:2020?<\/li>\n<li data-section-id=\"e7ia1c\" data-start=\"24808\" data-end=\"24844\">Is IS 13095:1991 still applicable?<\/li>\n<li data-section-id=\"sltfpw\" data-start=\"24845\" data-end=\"24892\">What tests are required for Butterfly Valves?<\/li>\n<li data-section-id=\"1lh9kwy\" data-start=\"24893\" data-end=\"24920\">Is body testing required?<\/li>\n<li data-section-id=\"1o6h169\" data-start=\"24921\" data-end=\"24948\">Is seat testing required?<\/li>\n<li data-section-id=\"1qeuy0a\" data-start=\"24949\" data-end=\"24985\">Is disc strength testing required?<\/li>\n<li data-section-id=\"t62oq2\" data-start=\"24986\" data-end=\"25020\">Is performance testing required?<\/li>\n<li data-section-id=\"jjofzc\" data-start=\"25021\" data-end=\"25047\">What sample is required?<\/li>\n<li data-section-id=\"1smx3b2\" data-start=\"25048\" data-end=\"25078\">What documents are required?<\/li>\n<li data-section-id=\"1hg6sd7\" data-start=\"25079\" data-end=\"25110\">What is the BIS testing cost?<\/li>\n<li data-section-id=\"yaj966\" data-start=\"25111\" data-end=\"25144\">Is factory inspection required?<\/li>\n<li data-section-id=\"1u6f3su\" data-start=\"25145\" data-end=\"25198\">Can foreign manufacturers obtain BIS Certification?<\/li>\n<li data-section-id=\"1t345hb\" data-start=\"25199\" data-end=\"25238\">Can one licence cover multiple sizes?<\/li>\n<li data-section-id=\"10p4ii\" data-start=\"25239\" data-end=\"25273\">What is a wafer butterfly valve?<\/li>\n<li data-section-id=\"tmhahy\" data-start=\"25274\" data-end=\"25317\">What is a double-flanged butterfly valve?<\/li>\n<li data-section-id=\"1v8nyp2\" data-start=\"25318\" data-end=\"25352\">What is the BIS licence process?<\/li>\n<li data-section-id=\"cgp9m4\" data-start=\"25353\" data-end=\"25385\">How can Qualitance India help?<\/li>\n<\/ul>\n<hr data-start=\"25387\" data-end=\"25390\" \/>\n<h1 data-section-id=\"170ztja\" data-start=\"25392\" data-end=\"25419\">Service Schema Suggestion<\/h1>\n<p data-start=\"25421\" data-end=\"25489\"><strong data-start=\"25421\" data-end=\"25438\">Service Name:<\/strong> BIS Certification Consultancy for Butterfly Valves<\/p>\n<p data-start=\"25491\" data-end=\"25538\"><strong data-start=\"25491\" data-end=\"25508\">Service Type:<\/strong> BIS Certification Consultancy<\/p>\n<p data-start=\"25540\" data-end=\"25608\"><strong data-start=\"25540\" data-end=\"25564\">Applicable Standard:<\/strong> IS 13095:1991 \/ applicable current revision<\/p>\n<p data-start=\"25610\" data-end=\"25660\"><strong data-start=\"25610\" data-end=\"25622\">Product:<\/strong> Butterfly Valves for General Purposes<\/p>\n<p data-start=\"25662\" data-end=\"25692\"><strong data-start=\"25662\" data-end=\"25675\">Provider:<\/strong> Qualitance India<\/p>\n<p data-start=\"25694\" data-end=\"25716\"><strong data-start=\"25694\" data-end=\"25710\">Area Served:<\/strong> India<\/p>\n<p data-start=\"25718\" data-end=\"25941\"><strong data-start=\"25718\" data-end=\"25734\">Description:<\/strong> Professional BIS Certification Consultancy for Butterfly Valves, including standard applicability assessment, documentation, testing coordination, BIS application support and factory inspection preparation.<\/p>\n<hr data-start=\"25943\" data-end=\"25946\" \/>\n<h1 data-section-id=\"1hya0ow\" data-start=\"25948\" data-end=\"25980\">Organization Schema Suggestion<\/h1>\n<p data-start=\"25982\" data-end=\"26021\"><strong data-start=\"25982\" data-end=\"26004\">Organization Name:<\/strong> Qualitance India<\/p>\n<p data-start=\"26023\" data-end=\"26068\"><strong data-start=\"26023\" data-end=\"26035\">Tagline:<\/strong> Improving Quality and Competence<\/p>\n<p data-start=\"26070\" data-end=\"26097\"><strong data-start=\"26070\" data-end=\"26080\">Phone:<\/strong> +91-9310-615-170<\/p>\n<p data-start=\"26099\" data-end=\"26134\"><strong data-start=\"26099\" data-end=\"26109\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"26110\" data-end=\"26134\">info@qualitanceindia.com<\/a><\/p>\n<p data-start=\"26136\" data-end=\"26168\"><strong data-start=\"26136\" data-end=\"26148\">Website:<\/strong> qualitanceindia.com<\/p>\n<hr data-start=\"26170\" data-end=\"26173\" \/>\n<h1 data-section-id=\"1q6ylnk\" data-start=\"26175\" data-end=\"26205\">Breadcrumb Schema Suggestion<\/h1>\n<p data-start=\"26207\" data-end=\"26290\"><strong data-start=\"26207\" data-end=\"26290\">Home \u2192 BIS Certification \u2192 Industrial Valves \u2192 Butterfly Valves \u2192 IS 13095:1991<\/strong><\/p>\n<hr data-start=\"26292\" data-end=\"26295\" \/>\n<h1 data-section-id=\"1jvka9r\" data-start=\"26297\" data-end=\"26324\">Article Schema Suggestion<\/h1>\n<p data-start=\"26326\" data-end=\"26365\"><strong data-start=\"26326\" data-end=\"26343\">Article Type:<\/strong> Article \/ BlogPosting<\/p>\n<p data-start=\"26367\" data-end=\"26456\"><strong data-start=\"26367\" data-end=\"26380\">Headline:<\/strong> BIS Certification for Butterfly Valves for General Purposes \u2013 IS 13095:1991<\/p>\n<p data-start=\"26458\" data-end=\"26486\"><strong data-start=\"26458\" data-end=\"26469\">Author:<\/strong> Qualitance India<\/p>\n<p data-start=\"26488\" data-end=\"26519\"><strong data-start=\"26488\" data-end=\"26502\">Publisher:<\/strong> Qualitance India<\/p>\n<p data-start=\"26521\" data-end=\"26592\"><strong data-start=\"26521\" data-end=\"26541\">Article Section:<\/strong> BIS Certification \/ Industrial Valve Certification<\/p>\n<p data-start=\"26594\" data-end=\"26708\"><strong data-start=\"26594\" data-end=\"26607\">Keywords:<\/strong> BIS Certification for Butterfly Valves, IS 13095:1991, Butterfly Valve BIS Licence, IS 13095 Testing<\/p>\n<hr data-start=\"26710\" data-end=\"26713\" \/>\n<h1 data-section-id=\"rt25q1\" data-start=\"26715\" data-end=\"26731\">Image ALT Tags<\/h1>\n<ol data-start=\"26733\" data-end=\"27309\">\n<li data-section-id=\"10bvwa1\" data-start=\"26733\" data-end=\"26774\">BIS Certification for Butterfly Valves<\/li>\n<li data-section-id=\"1o20ox3\" data-start=\"26775\" data-end=\"26809\">IS 13095:1991 BIS Certification<\/li>\n<li data-section-id=\"3ak2cw\" data-start=\"26810\" data-end=\"26840\">Butterfly Valve BIS Licence<\/li>\n<li data-section-id=\"1zfiiq\" data-start=\"26841\" data-end=\"26868\">Butterfly Valve ISI Mark<\/li>\n<li data-section-id=\"lgu721\" data-start=\"26869\" data-end=\"26911\">BIS Certification for Industrial Valves<\/li>\n<li data-section-id=\"1j09ovo\" data-start=\"26912\" data-end=\"26947\">IS 13095 Butterfly Valve Testing<\/li>\n<li data-section-id=\"3r8hpd\" data-start=\"26948\" data-end=\"26983\">BIS Testing for Butterfly Valves<\/li>\n<li data-section-id=\"af03vz\" data-start=\"26984\" data-end=\"27026\">Wafer Butterfly Valve BIS Certification<\/li>\n<li data-section-id=\"140z4tb\" data-start=\"27027\" data-end=\"27078\">Double Flanged Butterfly Valve BIS Certification<\/li>\n<li data-section-id=\"14x4vjp\" data-start=\"27079\" data-end=\"27123\">Butterfly Valve Manufacturer BIS Licence<\/li>\n<li data-section-id=\"1xse23m\" data-start=\"27124\" data-end=\"27159\">IS 13095 BIS Testing Laboratory<\/li>\n<li data-section-id=\"107jpdh\" data-start=\"27160\" data-end=\"27189\">Butterfly Valve Body Test<\/li>\n<li data-section-id=\"1sfcpif\" data-start=\"27190\" data-end=\"27219\">Butterfly Valve Seat Test<\/li>\n<li data-section-id=\"1etofwb\" data-start=\"27220\" data-end=\"27258\">Butterfly Valve Disc Strength Test<\/li>\n<li data-section-id=\"8e9kr4\" data-start=\"27259\" data-end=\"27309\">Qualitance India BIS Certification Consultancy<\/li>\n<\/ol>\n<hr data-start=\"27311\" data-end=\"27314\" \/>\n<h1 data-section-id=\"1nvnzyy\" data-start=\"27316\" data-end=\"27343\">Internal Linking Strategy<\/h1>\n<p data-start=\"27345\" data-end=\"27409\">Is blog ko website ke following pages se internally link karein:<\/p>\n<ul data-start=\"27411\" data-end=\"27764\">\n<li data-section-id=\"18of9wh\" data-start=\"27411\" data-end=\"27442\">BIS Certification Consultancy<\/li>\n<li data-section-id=\"wihhr7\" data-start=\"27443\" data-end=\"27470\">BIS Certification Process<\/li>\n<li data-section-id=\"12xzhqb\" data-start=\"27471\" data-end=\"27495\">BIS Certification Cost<\/li>\n<li data-section-id=\"1y3ly1g\" data-start=\"27496\" data-end=\"27525\">BIS Certification Documents<\/li>\n<li data-section-id=\"oaqr2l\" data-start=\"27526\" data-end=\"27547\">BIS Product Testing<\/li>\n<li data-section-id=\"ffrh22\" data-start=\"27548\" data-end=\"27572\">BIS Factory Inspection<\/li>\n<li data-section-id=\"nf47x2\" data-start=\"27573\" data-end=\"27597\">ISI Mark Certification<\/li>\n<li data-section-id=\"30r38\" data-start=\"27598\" data-end=\"27636\">Industrial Product BIS Certification<\/li>\n<li data-section-id=\"se1cch\" data-start=\"27637\" data-end=\"27665\">QCO Compliance Consultancy<\/li>\n<li data-section-id=\"qe41tt\" data-start=\"27666\" data-end=\"27706\">Foreign Manufacturer BIS Certification<\/li>\n<li data-section-id=\"9bkvo8\" data-start=\"27707\" data-end=\"27728\">Valve Certification<\/li>\n<li data-section-id=\"qqj1sy\" data-start=\"27729\" data-end=\"27764\">Engineering Product Certification<\/li>\n<\/ul>\n<h3 data-section-id=\"kwi7h3\" data-start=\"27766\" data-end=\"27793\">Recommended Anchor Text<\/h3>\n<ul data-start=\"27795\" data-end=\"28041\">\n<li data-section-id=\"wihhr7\" data-start=\"27795\" data-end=\"27822\">BIS Certification Process<\/li>\n<li data-section-id=\"12xzhqb\" data-start=\"27823\" data-end=\"27847\">BIS Certification Cost<\/li>\n<li data-section-id=\"1emcsx4\" data-start=\"27848\" data-end=\"27870\">BIS Testing Services<\/li>\n<li data-section-id=\"ffrh22\" data-start=\"27871\" data-end=\"27895\">BIS Factory Inspection<\/li>\n<li data-section-id=\"nf47x2\" data-start=\"27896\" data-end=\"27920\">ISI Mark Certification<\/li>\n<li data-section-id=\"1s3yp6n\" data-start=\"27921\" data-end=\"27953\">Industrial Valve Certification<\/li>\n<li data-section-id=\"l1ko6c\" data-start=\"27954\" data-end=\"27985\">BIS Licence for Manufacturers<\/li>\n<li data-section-id=\"yzfkkb\" data-start=\"27986\" data-end=\"28012\">Product Testing Services<\/li>\n<li data-section-id=\"se1cch\" data-start=\"28013\" data-end=\"28041\">QCO Compliance Consultancy<\/li>\n<\/ul>\n<hr data-start=\"28043\" data-end=\"28046\" \/>\n<h1 data-section-id=\"18sbunm\" data-start=\"28048\" data-end=\"28079\">External Authority References<\/h1>\n<p data-start=\"28081\" data-end=\"28143\">Website ke E-E-A-T ke liye official BIS references use karein:<\/p>\n<p data-start=\"28145\" data-end=\"28225\"><strong data-start=\"28145\" data-end=\"28183\">BIS Product Manual \u2013 IS 13095:1991<\/strong><br data-start=\"28183\" data-end=\"28186\" \/><span class=\"contents\" data-content-reference-start=\"27714\" data-content-reference-end=\"27822\"><span class=\"\" data-state=\"closed\"><a class=\"decorated-link\" href=\"https:\/\/www.bis.gov.in\/wp-content\/uploads\/2019\/03\/PM-IS-13095.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">BIS Product Manual for IS 13095:1991<\/a><\/span><\/span><\/p>\n<p data-start=\"28227\" data-end=\"28309\"><strong data-start=\"28227\" data-end=\"28267\">BIS Standard Preview \u2013 IS 13095:1991<\/strong><br data-start=\"28267\" data-end=\"28270\" \/><span class=\"contents\" data-content-reference-start=\"27867\" data-content-reference-end=\"27955\"><span class=\"\" data-state=\"closed\"><a class=\"decorated-link\" href=\"https:\/\/services.bis.gov.in\/tmp\/SR13095.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">BIS Standard Preview for IS 13095:1991<\/a><\/span><\/span><\/p>\n<p data-start=\"28311\" data-end=\"28396\"><strong data-start=\"28311\" data-end=\"28354\">BIS LIMS \u2013 IS 13095 Testing Information<\/strong><br data-start=\"28354\" data-end=\"28357\" \/><span class=\"contents\" data-content-reference-start=\"28003\" data-content-reference-end=\"28108\"><span class=\"\" data-state=\"closed\"><a class=\"decorated-link\" href=\"https:\/\/lims.bis.gov.in\/home\/search_is_number\/?is_number__doc_no=13095&amp;utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">BIS LIMS Testing Information<\/a><\/span><\/span><\/p>\n<p data-start=\"28398\" data-end=\"28478\"><strong data-start=\"28398\" data-end=\"28436\">BIS Product Manual \u2013 IS 13095:2020<\/strong><br data-start=\"28436\" data-end=\"28439\" \/><span class=\"contents\" data-content-reference-start=\"28151\" data-content-reference-end=\"28275\"><span class=\"\" data-state=\"closed\"><a class=\"decorated-link\" href=\"https:\/\/www.bis.gov.in\/wp-content\/uploads\/2022\/02\/PM-IS-13095-Second-revision.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">BIS Product Manual for IS 13095:2020<\/a><\/span><\/span><\/p>\n<hr data-start=\"28480\" data-end=\"28483\" \/>\n<h1 data-section-id=\"i4bqxr\" data-start=\"28485\" data-end=\"28507\">Related BIS Services<\/h1>\n<ol data-start=\"28509\" data-end=\"28929\">\n<li data-section-id=\"10bvwa1\" data-start=\"28509\" data-end=\"28550\">BIS Certification for Butterfly Valves<\/li>\n<li data-section-id=\"tjr2zi\" data-start=\"28551\" data-end=\"28593\">BIS Certification for Industrial Valves<\/li>\n<li data-section-id=\"15sv9in\" data-start=\"28594\" data-end=\"28630\">BIS Certification for Gate Valves<\/li>\n<li data-section-id=\"6xyrwc\" data-start=\"28631\" data-end=\"28667\">BIS Certification for Ball Valves<\/li>\n<li data-section-id=\"1xcpq6w\" data-start=\"28668\" data-end=\"28705\">BIS Certification for Check Valves<\/li>\n<li data-section-id=\"r73izi\" data-start=\"28706\" data-end=\"28743\">BIS Certification for Globe Valves<\/li>\n<li data-section-id=\"keuhl5\" data-start=\"28744\" data-end=\"28781\">BIS Certification for Water Valves<\/li>\n<li data-section-id=\"sqf0gm\" data-start=\"28782\" data-end=\"28804\">BIS Product Testing<\/li>\n<li data-section-id=\"ntdbgm\" data-start=\"28805\" data-end=\"28841\">BIS Factory Inspection Assistance<\/li>\n<li data-section-id=\"1cfvx2n\" data-start=\"28842\" data-end=\"28871\">BIS Documentation Support<\/li>\n<li data-section-id=\"1ij9aqd\" data-start=\"28872\" data-end=\"28898\">ISI Mark Certification<\/li>\n<li data-section-id=\"1jbydj5\" data-start=\"28899\" data-end=\"28929\">QCO Compliance Consultancy<\/li>\n<\/ol>\n<hr data-start=\"28931\" data-end=\"28934\" \/>\n<h1 data-section-id=\"10fksa8\" data-start=\"28936\" data-end=\"28962\">Related Blog Suggestions<\/h1>\n<ol data-start=\"28964\" data-end=\"29750\">\n<li data-section-id=\"q3qv7t\" data-start=\"28964\" data-end=\"29026\"><strong data-start=\"28967\" data-end=\"29026\">BIS Certification for Butterfly Valves \u2013 Complete Guide<\/strong><\/li>\n<li data-section-id=\"gfe60m\" data-start=\"29027\" data-end=\"29084\"><strong data-start=\"29030\" data-end=\"29084\">IS 13095:1991 \u2013 Complete BIS Certification Process<\/strong><\/li>\n<li data-section-id=\"slj0xc\" data-start=\"29085\" data-end=\"29144\"><strong data-start=\"29088\" data-end=\"29144\">IS 13095:1991 vs IS 13095:2020 \u2013 Complete Difference<\/strong><\/li>\n<li data-section-id=\"t3jsab\" data-start=\"29145\" data-end=\"29199\"><strong data-start=\"29148\" data-end=\"29199\">Butterfly Valve Testing Requirements as per BIS<\/strong><\/li>\n<li data-section-id=\"noesg6\" data-start=\"29200\" data-end=\"29250\"><strong data-start=\"29203\" data-end=\"29250\">BIS Certification Cost for Butterfly Valves<\/strong><\/li>\n<li data-section-id=\"az35ew\" data-start=\"29251\" data-end=\"29314\"><strong data-start=\"29254\" data-end=\"29314\">Documents Required for Butterfly Valve BIS Certification<\/strong><\/li>\n<li data-section-id=\"1bn9ate\" data-start=\"29315\" data-end=\"29365\"><strong data-start=\"29318\" data-end=\"29365\">BIS Testing Laboratory for Butterfly Valves<\/strong><\/li>\n<li data-section-id=\"2hl06n\" data-start=\"29366\" data-end=\"29412\"><strong data-start=\"29369\" data-end=\"29412\">Wafer Butterfly Valve BIS Certification<\/strong><\/li>\n<li data-section-id=\"3ixk4f\" data-start=\"29413\" data-end=\"29468\"><strong data-start=\"29416\" data-end=\"29468\">Double Flanged Butterfly Valve BIS Certification<\/strong><\/li>\n<li data-section-id=\"lciwl6\" data-start=\"29469\" data-end=\"29529\"><strong data-start=\"29473\" data-end=\"29529\">BIS Certification for Industrial Valve Manufacturers<\/strong><\/li>\n<li data-section-id=\"1ipmef0\" data-start=\"29530\" data-end=\"29571\"><strong data-start=\"29534\" data-end=\"29571\">BIS Certification for Gate Valves<\/strong><\/li>\n<li data-section-id=\"ru0vxn\" data-start=\"29572\" data-end=\"29613\"><strong data-start=\"29576\" data-end=\"29613\">BIS Certification for Ball Valves<\/strong><\/li>\n<li data-section-id=\"i8sizz\" data-start=\"29614\" data-end=\"29656\"><strong data-start=\"29618\" data-end=\"29656\">BIS Certification for Check Valves<\/strong><\/li>\n<li data-section-id=\"bssai5\" data-start=\"29657\" data-end=\"29699\"><strong data-start=\"29661\" data-end=\"29699\">BIS Certification for Globe Valves<\/strong><\/li>\n<li data-section-id=\"1jd0tr7\" data-start=\"29700\" data-end=\"29750\"><strong data-start=\"29704\" data-end=\"29750\">Latest BIS Standards for Industrial Valves<\/strong><\/li>\n<\/ol>\n<hr data-start=\"29752\" data-end=\"29755\" \/>\n<h1 data-section-id=\"o5tkrt\" data-start=\"29757\" data-end=\"29785\">Strong Lead Generation CTA<\/h1>\n<h2 data-section-id=\"vy6mar\" data-start=\"29787\" data-end=\"29834\">Need BIS Certification for Butterfly Valves?<\/h2>\n<p data-start=\"29836\" data-end=\"30009\">Are you a <strong data-start=\"29846\" data-end=\"29978\">Butterfly Valve Manufacturer, Industrial Valve Manufacturer, Pipeline Equipment Manufacturer or Engineering Product Manufacturer<\/strong> looking for BIS Certification?<\/p>\n<p data-start=\"30011\" data-end=\"30091\"><strong data-start=\"30011\" data-end=\"30031\">Qualitance India<\/strong> can assist you with the complete BIS certification process.<\/p>\n<h3 data-section-id=\"jnsw6s\" data-start=\"30093\" data-end=\"30118\">Our Support Includes:<\/h3>\n<p data-start=\"30120\" data-end=\"30500\">\u2713 Product Applicability Assessment<br data-start=\"30154\" data-end=\"30157\" \/>\u2713 IS 13095 Standard Assessment<br data-start=\"30187\" data-end=\"30190\" \/>\u2713 Current Revision Verification<br data-start=\"30221\" data-end=\"30224\" \/>\u2713 Product Scope Assessment<br data-start=\"30250\" data-end=\"30253\" \/>\u2713 Documentation Support<br data-start=\"30276\" data-end=\"30279\" \/>\u2713 Laboratory Testing Coordination<br data-start=\"30312\" data-end=\"30315\" \/>\u2713 Sample Preparation Guidance<br data-start=\"30344\" data-end=\"30347\" \/>\u2713 BIS Application Assistance<br data-start=\"30375\" data-end=\"30378\" \/>\u2713 Factory Inspection Preparation<br data-start=\"30410\" data-end=\"30413\" \/>\u2713 Quality-Control Documentation<br data-start=\"30444\" data-end=\"30447\" \/>\u2713 Observation Closure Support<br data-start=\"30476\" data-end=\"30479\" \/>\u2713 ISI Mark Guidance<\/p>\n<h3 data-section-id=\"16z2skw\" data-start=\"30502\" data-end=\"30530\">Contact Qualitance India<\/h3>\n<p data-start=\"30532\" data-end=\"30618\"><strong data-start=\"30532\" data-end=\"30555\">\ud83d\udcde +91-9310-615-170<\/strong><br data-start=\"30555\" data-end=\"30558\" \/><strong data-start=\"30558\" data-end=\"30589\">\ud83d\udce7 <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"30563\" data-end=\"30587\">info@qualitanceindia.com<\/a><\/strong><br data-start=\"30589\" data-end=\"30592\" \/><strong data-start=\"30592\" data-end=\"30618\">\ud83c\udf10 qualitanceindia.com<\/strong><\/p>\n<p data-start=\"30620\" data-end=\"30675\"><strong data-start=\"30620\" data-end=\"30675\">QUALITANCE INDIA \u2013 IMPROVING QUALITY AND COMPETENCE<\/strong><\/p>\n<hr data-start=\"30677\" data-end=\"30680\" \/>\n<h1 data-section-id=\"1xjcl0s\" data-start=\"30682\" data-end=\"30708\">SEO-Optimized Conclusion<\/h1>\n<p data-start=\"30710\" data-end=\"30943\"><strong data-start=\"30710\" data-end=\"30794\">BIS Certification for Butterfly Valves for General Purposes as per IS 13095:1991<\/strong> involves evaluating the applicable valve design, material, dimensions, pressure designation, end connection, operation and performance requirements.<\/p>\n<p data-start=\"30945\" data-end=\"31206\">IS 13095:1991 covers a broad range of general-purpose butterfly valves, including <strong data-start=\"31027\" data-end=\"31165\">double-flanged and wafer-type valves, metal-seated and resilient-seated valves, cast iron, ductile iron, carbon steel and lined valves<\/strong>.<\/p>\n<p data-start=\"31208\" data-end=\"31423\">The BIS Product Manual identifies important certification elements including product grouping, sample requirements, testing equipment and the Scheme of Inspection and Testing.<\/p>\n<p data-start=\"31425\" data-end=\"31758\">However, because <strong data-start=\"31442\" data-end=\"31492\">IS 13095:2020 is the subsequent first revision<\/strong>, manufacturers should verify the current applicable standard before submitting a fresh BIS application. BIS has also published amendments to the 2020 standard, making current applicability verification particularly important.<\/p>\n<p data-start=\"31760\" data-end=\"32012\">For professional assistance with <strong data-start=\"31793\" data-end=\"31946\">BIS Certification for Butterfly Valves, IS 13095 applicability, laboratory testing, documentation, BIS application and factory inspection preparation<\/strong>, <strong data-start=\"31948\" data-end=\"31968\">Qualitance India<\/strong> can provide end-to-end consultancy support.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction BIS Certification for Butterfly Valves is an important compliance consideration for manufacturers whose butterfly valves fall under the applicable BIS certification requirements. IS 13095:1991 is titled \u201cButterfly Valves for General Purposes.\u201d The standard covers double-flanged and wafer-type butterfly valves, including metal-seated and resilient-seated valves made from materials such as cast iron, ductile iron and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3422,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"inline_featured_image":false,"slim_seo":{"title":"BIS Certification for Butterfly Valves for General Purposes | IS 13095:1991 - Qualitance India","description":"Introduction BIS Certification for Butterfly Valves is an important compliance consideration for manufacturers whose butterfly valves fall under the applicable"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3421","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3421","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3421"}],"version-history":[{"count":1,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3421\/revisions"}],"predecessor-version":[{"id":3423,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3421\/revisions\/3423"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3422"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3421"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3421"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3421"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a4cebdea01328942bf8f471. Config Timestamp: 2026-07-07 12:06:54 UTC, Cached Timestamp: 2026-09-11 20:20:23 UTC, Optimization Time: 2.09ms -->