{"id":3578,"date":"2026-08-27T11:24:39","date_gmt":"2026-08-27T11:24:39","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3578"},"modified":"2026-08-27T11:24:39","modified_gmt":"2026-08-27T11:24:39","slug":"bis-certification-consultancy-for-structural-weather-resistant-steel-is-115871986-bis-isi-mark-certification","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-consultancy-for-structural-weather-resistant-steel-is-115871986-bis-isi-mark-certification\/","title":{"rendered":"BIS Certification Consultancy for Structural Weather Resistant Steel | IS 11587:1986 | BIS &#038; ISI Mark Certification"},"content":{"rendered":"<div class=\"flex max-w-full flex-col gap-4 grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+&amp;]:mt-1\" dir=\"auto\" tabindex=\"0\" data-message-author-role=\"assistant\" data-message-id=\"f96e17a5-beea-4435-a2d4-b432dff728f1\" data-turn-start-message=\"true\" data-message-model-slug=\"gpt-5-6-t-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden\">\n<div class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\">\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"12q1sue\" data-start=\"866\" data-end=\"880\">Introduction<\/h1>\n<p data-start=\"882\" data-end=\"1206\">Structural weather resistant steel is a type of high-strength low-alloy structural steel developed to provide improved resistance to atmospheric corrosion. It is intended for structural applications where steel is exposed to outdoor atmospheric conditions and where improved durability and reduced maintenance are important.<\/p>\n<p data-start=\"1208\" data-end=\"1759\">In India, <strong data-start=\"1218\" data-end=\"1290\">IS 11587:1986 \u2013 Specification for Structural Weather Resistant Steel<\/strong> covers weather-resistant structural steels in the form of <strong data-start=\"1349\" data-end=\"1417\">plates, sheets, strips, sections, bars and other specified forms<\/strong>. The standard is intended for welded, riveted or bolted construction requiring atmospheric corrosion resistance. BIS&#8217;s technical summary explains that the standard addresses chemical composition, mechanical properties, dimensional requirements and bend-test requirements for the different product forms.<\/p>\n<p data-start=\"1761\" data-end=\"2106\">The current BIS Product Manual <strong data-start=\"1792\" data-end=\"1822\">PM\/11587\/1, September 2022<\/strong> provides certification guidance under <strong data-start=\"1861\" data-end=\"1924\">Scheme-I of the BIS Conformity Assessment Regulations, 2018<\/strong>. It identifies the applicable grades, product forms, grouping guidelines, sample sizes, testing equipment and Scheme of Inspection and Testing.<\/p>\n<p data-start=\"2108\" data-end=\"2366\">IS 11587:1986 is also specifically included in the <strong data-start=\"2159\" data-end=\"2217\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, where it is listed as <strong data-start=\"2241\" data-end=\"2279\">Structural Weather Resistant Steel<\/strong> with implementation <strong data-start=\"2300\" data-end=\"2328\">\u201cWith immediate effect.\u201d<\/strong><\/p>\n<p data-start=\"2368\" data-end=\"2691\"><strong data-start=\"2368\" data-end=\"2388\">Qualitance India<\/strong> provides end-to-end BIS Certification Consultancy for Structural Weather Resistant Steel as per <strong data-start=\"2485\" data-end=\"2502\">IS 11587:1986<\/strong>, including product assessment, grade and product-form review, grouping guidance, documentation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<hr data-start=\"2693\" data-end=\"2696\" \/>\n<h1 data-section-id=\"1pd0lhx\" data-start=\"2698\" data-end=\"2722\">What is IS 11587:1986?<\/h1>\n<p data-start=\"2724\" data-end=\"2752\"><strong data-start=\"2724\" data-end=\"2741\">IS 11587:1986<\/strong> is titled:<\/p>\n<p data-start=\"2754\" data-end=\"2812\"><strong data-start=\"2754\" data-end=\"2812\">\u201cSpecification for Structural Weather Resistant Steel\u201d<\/strong><\/p>\n<p data-start=\"2814\" data-end=\"3011\">BIS&#8217;s Product Manual identifies it as the applicable Indian Standard and records <strong data-start=\"2895\" data-end=\"2912\">one amendment<\/strong>. The certification framework is operated under <strong data-start=\"2960\" data-end=\"2972\">Scheme-I<\/strong>.<\/p>\n<p data-start=\"3013\" data-end=\"3159\">The standard provides requirements for weather-resistant structural steel used in construction where atmospheric corrosion resistance is required.<\/p>\n<p data-start=\"3161\" data-end=\"3209\">Important areas covered by the standard include:<\/p>\n<ul data-start=\"3211\" data-end=\"3438\">\n<li data-section-id=\"v16bzo\" data-start=\"3211\" data-end=\"3233\">Chemical composition<\/li>\n<li data-section-id=\"8bckeo\" data-start=\"3234\" data-end=\"3247\">Weldability<\/li>\n<li data-section-id=\"r8mtb9\" data-start=\"3248\" data-end=\"3268\">Tensile properties<\/li>\n<li data-section-id=\"1r26z8w\" data-start=\"3269\" data-end=\"3285\">Yield strength<\/li>\n<li data-section-id=\"15qwr16\" data-start=\"3286\" data-end=\"3298\">Elongation<\/li>\n<li data-section-id=\"4caeur\" data-start=\"3299\" data-end=\"3310\">Bend test<\/li>\n<li data-section-id=\"o1l5ek\" data-start=\"3311\" data-end=\"3324\">Impact test<\/li>\n<li data-section-id=\"sjph9u\" data-start=\"3325\" data-end=\"3360\">Flattening test, where applicable<\/li>\n<li data-section-id=\"1g7qg16\" data-start=\"3361\" data-end=\"3383\">Freedom from defects<\/li>\n<li data-section-id=\"zy1zez\" data-start=\"3384\" data-end=\"3396\">Dimensions<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"3397\" data-end=\"3409\">Tolerances<\/li>\n<li data-section-id=\"1j3zlok\" data-start=\"3410\" data-end=\"3416\">Mass<\/li>\n<li data-section-id=\"11fistr\" data-start=\"3417\" data-end=\"3438\">Marking and packing<\/li>\n<\/ul>\n<p data-start=\"3440\" data-end=\"3573\">The BIS Product Manual identifies these requirements through its testing and inspection scheme.<\/p>\n<hr data-start=\"3575\" data-end=\"3578\" \/>\n<h1 data-section-id=\"zf6tee\" data-start=\"3580\" data-end=\"3625\">What is Structural Weather Resistant Steel?<\/h1>\n<p data-start=\"3627\" data-end=\"3757\">Structural weather resistant steel is steel developed to withstand atmospheric exposure better than conventional structural steel.<\/p>\n<p data-start=\"3759\" data-end=\"4107\">Its improved atmospheric corrosion resistance is achieved through controlled chemical composition and alloying. BIS&#8217;s summary explains that the standard covers <strong data-start=\"3919\" data-end=\"3982\">high-strength low-alloy weather-resistant structural steels<\/strong> for welded, riveted or bolted construction requiring atmospheric corrosion resistance.<\/p>\n<p data-start=\"4109\" data-end=\"4224\">The objective is to improve structural durability in environments where the steel is exposed to weather conditions.<\/p>\n<p data-start=\"4226\" data-end=\"4259\">Such steel may be considered for:<\/p>\n<ul data-start=\"4261\" data-end=\"4481\">\n<li data-section-id=\"122uwas\" data-start=\"4261\" data-end=\"4270\">Bridges<\/li>\n<li data-section-id=\"1gmhlih\" data-start=\"4271\" data-end=\"4294\">Industrial structures<\/li>\n<li data-section-id=\"ehxygn\" data-start=\"4295\" data-end=\"4315\">Railway structures<\/li>\n<li data-section-id=\"18bv650\" data-start=\"4316\" data-end=\"4342\">Outdoor steel frameworks<\/li>\n<li data-section-id=\"kscxd5\" data-start=\"4343\" data-end=\"4368\">Infrastructure projects<\/li>\n<li data-section-id=\"luc74p\" data-start=\"4369\" data-end=\"4391\">Structural platforms<\/li>\n<li data-section-id=\"j44qt1\" data-start=\"4392\" data-end=\"4434\">Storage and material-handling structures<\/li>\n<li data-section-id=\"p2xpzz\" data-start=\"4435\" data-end=\"4481\">Buildings and other exposed steel structures<\/li>\n<\/ul>\n<p data-start=\"4483\" data-end=\"4583\">The actual suitability depends on structural design, exposure conditions and project specifications.<\/p>\n<hr data-start=\"4585\" data-end=\"4588\" \/>\n<h1 data-section-id=\"xqa8dc\" data-start=\"4590\" data-end=\"4628\">Why is Weather Resistant Steel Used?<\/h1>\n<p data-start=\"4630\" data-end=\"4691\">Atmospheric exposure can cause corrosion of structural steel.<\/p>\n<p data-start=\"4693\" data-end=\"4921\">Weather resistant steels are designed with controlled chemistry to provide improved resistance to atmospheric corrosion. This can help reduce corrosion-related deterioration and maintenance requirements in suitable applications.<\/p>\n<p data-start=\"4923\" data-end=\"5142\">The BIS technical summary specifically describes the purpose of IS 11587 as providing structural weather-resistant steel for applications requiring atmospheric corrosion resistance.<\/p>\n<p data-start=\"5144\" data-end=\"5361\">However, weather resistant steel should not automatically be considered corrosion-proof. The actual performance depends on exposure conditions, design, surface condition, drainage, detailing and environmental factors.<\/p>\n<hr data-start=\"5363\" data-end=\"5366\" \/>\n<h1 data-section-id=\"1dgu309\" data-start=\"5368\" data-end=\"5392\">Scope of IS 11587:1986<\/h1>\n<p data-start=\"5394\" data-end=\"5481\">The BIS Product Manual defines the licence scope using product grades, forms and sizes.<\/p>\n<p data-start=\"5483\" data-end=\"5531\">The grades identified in the Product Manual are:<\/p>\n<ul data-start=\"5533\" data-end=\"5616\">\n<li data-section-id=\"1557fha\" data-start=\"5533\" data-end=\"5549\"><strong data-start=\"5535\" data-end=\"5549\">WR-Fe 480A<\/strong><\/li>\n<li data-section-id=\"1557d3x\" data-start=\"5550\" data-end=\"5566\"><strong data-start=\"5552\" data-end=\"5566\">WR-Fe 480B<\/strong><\/li>\n<li data-section-id=\"1534k9i\" data-start=\"5567\" data-end=\"5583\"><strong data-start=\"5569\" data-end=\"5583\">WR-Fe 490H<\/strong><\/li>\n<li data-section-id=\"1534o7x\" data-start=\"5584\" data-end=\"5600\"><strong data-start=\"5586\" data-end=\"5600\">WR-Fe 490C<\/strong><\/li>\n<li data-section-id=\"9sl8c6\" data-start=\"5601\" data-end=\"5616\"><strong data-start=\"5603\" data-end=\"5616\">WR-Fe 500<\/strong><\/li>\n<\/ul>\n<p data-start=\"5618\" data-end=\"5672\">The Product Manual identifies product forms including:<\/p>\n<ul data-start=\"5674\" data-end=\"5740\">\n<li data-section-id=\"1756g9w\" data-start=\"5674\" data-end=\"5681\">Plate<\/li>\n<li data-section-id=\"178kxmv\" data-start=\"5682\" data-end=\"5689\">Sheet<\/li>\n<li data-section-id=\"178i5c4\" data-start=\"5690\" data-end=\"5697\">Strip<\/li>\n<li data-section-id=\"m12rle\" data-start=\"5698\" data-end=\"5708\">Sections<\/li>\n<li data-section-id=\"1j423d6\" data-start=\"5709\" data-end=\"5715\">Bars<\/li>\n<li data-section-id=\"10lgshw\" data-start=\"5716\" data-end=\"5740\">Other applicable forms<\/li>\n<\/ul>\n<p data-start=\"5742\" data-end=\"5880\">It also requires the applicable shapes and nominal size range to be identified in the licence scope.<\/p>\n<hr data-start=\"5882\" data-end=\"5885\" \/>\n<h1 data-section-id=\"1orv3bq\" data-start=\"5887\" data-end=\"5933\">Grades of Structural Weather Resistant Steel<\/h1>\n<h2 data-section-id=\"9yo103\" data-start=\"5935\" data-end=\"5948\">WR-Fe 480A<\/h2>\n<p data-start=\"5950\" data-end=\"6013\">WR-Fe 480A is one of the grades identified under IS 11587:1986.<\/p>\n<h2 data-section-id=\"9yo100\" data-start=\"6015\" data-end=\"6028\">WR-Fe 480B<\/h2>\n<p data-start=\"6030\" data-end=\"6105\">WR-Fe 480B is another grade included in the Product Manual&#8217;s licence scope.<\/p>\n<h2 data-section-id=\"9yo3h7\" data-start=\"6107\" data-end=\"6120\">WR-Fe 490H<\/h2>\n<p data-start=\"6122\" data-end=\"6208\">WR-Fe 490H is a higher-strength weather resistant steel grade covered by the standard.<\/p>\n<p data-start=\"6210\" data-end=\"6468\">The Product Manual notes a special condition for <strong data-start=\"6259\" data-end=\"6316\">WR-Fe 490H steel sheet and strip below 3 mm thickness<\/strong>, where a tensile strength of <strong data-start=\"6346\" data-end=\"6367\">510 N\/mm\u00b2 or more<\/strong> may apply by agreement between the purchaser and manufacturer.<\/p>\n<h2 data-section-id=\"9yo3gw\" data-start=\"6470\" data-end=\"6483\">WR-Fe 490C<\/h2>\n<p data-start=\"6485\" data-end=\"6526\">WR-Fe 490C is also included in the scope.<\/p>\n<p data-start=\"6528\" data-end=\"6718\">The inspection scheme specifically states that the bend test for this grade is <strong data-start=\"6607\" data-end=\"6619\">optional<\/strong> and is to be performed only when specified by the purchaser.<\/p>\n<h2 data-section-id=\"6rbzmj\" data-start=\"6720\" data-end=\"6732\">WR-Fe 500<\/h2>\n<p data-start=\"6734\" data-end=\"6854\">WR-Fe 500 is also identified in the Product Manual as part of the licence scope.<\/p>\n<hr data-start=\"6856\" data-end=\"6859\" \/>\n<h1 data-section-id=\"8h8m34\" data-start=\"6861\" data-end=\"6933\">Is BIS Certification Mandatory for Structural Weather Resistant Steel?<\/h1>\n<p data-start=\"6935\" data-end=\"7056\"><strong data-start=\"6935\" data-end=\"7056\">Yes. Structural Weather Resistant Steel under IS 11587:1986 is covered by the compulsory BIS certification framework.<\/strong><\/p>\n<p data-start=\"7058\" data-end=\"7140\">The <strong data-start=\"7062\" data-end=\"7120\">Steel and Steel Products (Quality Control) Order, 2024<\/strong> specifically lists:<\/p>\n<p data-start=\"7142\" data-end=\"7196\"><strong data-start=\"7142\" data-end=\"7196\">IS 11587:1986 \u2013 Structural Weather resistant steel<\/strong><\/p>\n<p data-start=\"7198\" data-end=\"7212\">and specifies:<\/p>\n<p data-start=\"7214\" data-end=\"7296\"><strong data-start=\"7214\" data-end=\"7256\">Implementation: With immediate effect.<\/strong><\/p>\n<p data-start=\"7298\" data-end=\"7443\">The current BIS Product Manual also provides certification guidance for IS 11587:1986 under <strong data-start=\"7390\" data-end=\"7402\">Scheme-I<\/strong>.<\/p>\n<p data-start=\"7445\" data-end=\"7598\">Manufacturers supplying covered products in India should therefore ensure that their products meet the applicable BIS certification and QCO requirements.<\/p>\n<p data-start=\"7600\" data-end=\"7743\">Manufacturers should also verify the latest amendments, exemptions and government notifications before making a final regulatory determination.<\/p>\n<hr data-start=\"7745\" data-end=\"7748\" \/>\n<h1 data-section-id=\"1j0p80p\" data-start=\"7750\" data-end=\"7804\">Steel and Steel Products Quality Control Order, 2024<\/h1>\n<p data-start=\"7806\" data-end=\"7925\">The 2024 Steel and Steel Products QCO specifically includes Structural Weather Resistant Steel under <strong data-start=\"7907\" data-end=\"7924\">IS 11587:1986<\/strong>.<\/p>\n<p data-start=\"7927\" data-end=\"8093\">The QCO lists a wide range of ITC (HS) classifications associated with the product and specifies <strong data-start=\"8024\" data-end=\"8052\">immediate implementation<\/strong>.<\/p>\n<p data-start=\"8095\" data-end=\"8240\">This makes BIS certification an important regulatory requirement for manufacturers supplying covered weather-resistant structural steel products.<\/p>\n<p data-start=\"8242\" data-end=\"8393\">The QCO framework also requires covered steel products to comply with their corresponding Indian Standards and applicable BIS certification provisions.<\/p>\n<hr data-start=\"8395\" data-end=\"8398\" \/>\n<h1 data-section-id=\"1heq6v6\" data-start=\"8400\" data-end=\"8458\">BIS Certification for Structural Weather Resistant Steel<\/h1>\n<p data-start=\"8460\" data-end=\"8635\">BIS Certification demonstrates that a manufacturer&#8217;s structural weather resistant steel has been assessed for conformity with the applicable requirements of <strong data-start=\"8617\" data-end=\"8634\">IS 11587:1986<\/strong>.<\/p>\n<p data-start=\"8637\" data-end=\"8806\">The Product Manual confirms that certification is operated under <strong data-start=\"8702\" data-end=\"8765\">Scheme-I of the BIS Conformity Assessment Regulations, 2018<\/strong>.<\/p>\n<p data-start=\"8808\" data-end=\"9006\">After successful conformity assessment and grant of the BIS licence, the manufacturer can use the applicable <strong data-start=\"8917\" data-end=\"8949\">BIS Standard Mark \/ ISI Mark<\/strong> on covered products according to the licence conditions.<\/p>\n<hr data-start=\"9008\" data-end=\"9011\" \/>\n<h1 data-section-id=\"17dlbqh\" data-start=\"9013\" data-end=\"9071\">Who Needs BIS Certification for Weather Resistant Steel?<\/h1>\n<p data-start=\"9073\" data-end=\"9190\">BIS certification is relevant to manufacturers producing Structural Weather Resistant Steel covered by IS 11587:1986.<\/p>\n<p data-start=\"9192\" data-end=\"9209\">This can include:<\/p>\n<ul data-start=\"9211\" data-end=\"9612\">\n<li data-section-id=\"vyqk7i\" data-start=\"9211\" data-end=\"9250\">Weather Resistant Steel Manufacturers<\/li>\n<li data-section-id=\"4wld7e\" data-start=\"9251\" data-end=\"9283\">Structural Steel Manufacturers<\/li>\n<li data-section-id=\"1jzrhgr\" data-start=\"9284\" data-end=\"9311\">Steel Plate Manufacturers<\/li>\n<li data-section-id=\"puw1xk\" data-start=\"9312\" data-end=\"9339\">Steel Sheet Manufacturers<\/li>\n<li data-section-id=\"1vzow97\" data-start=\"9340\" data-end=\"9367\">Steel Strip Manufacturers<\/li>\n<li data-section-id=\"1iem0s8\" data-start=\"9368\" data-end=\"9402\">Structural Section Manufacturers<\/li>\n<li data-section-id=\"wpims6\" data-start=\"9403\" data-end=\"9428\">Steel Bar Manufacturers<\/li>\n<li data-section-id=\"1oeknf3\" data-start=\"9429\" data-end=\"9474\">High Strength Low Alloy Steel Manufacturers<\/li>\n<li data-section-id=\"1o9sp4u\" data-start=\"9475\" data-end=\"9508\">Engineering Steel Manufacturers<\/li>\n<li data-section-id=\"1padg2o\" data-start=\"9509\" data-end=\"9545\">Infrastructure Steel Manufacturers<\/li>\n<li data-section-id=\"107vnwp\" data-start=\"9546\" data-end=\"9567\">Steel Rolling Mills<\/li>\n<li data-section-id=\"18qs2tn\" data-start=\"9568\" data-end=\"9587\">OEM Manufacturers<\/li>\n<li data-section-id=\"enlnku\" data-start=\"9588\" data-end=\"9612\">Contract Manufacturers<\/li>\n<\/ul>\n<p data-start=\"9614\" data-end=\"9749\">Importers and other businesses dealing with covered steel products should separately verify their obligations under the applicable QCO.<\/p>\n<hr data-start=\"9751\" data-end=\"9754\" \/>\n<h1 data-section-id=\"1sebo4n\" data-start=\"9756\" data-end=\"9800\">BIS Certification Eligibility Requirements<\/h1>\n<p data-start=\"9802\" data-end=\"9928\">A manufacturer seeking BIS certification should generally have suitable manufacturing, testing and quality-control facilities.<\/p>\n<p data-start=\"9930\" data-end=\"9948\">These may include:<\/p>\n<ul data-start=\"9950\" data-end=\"10488\">\n<li data-section-id=\"b34v57\" data-start=\"9950\" data-end=\"9992\">Steelmaking facilities, where applicable<\/li>\n<li data-section-id=\"c1otn2\" data-start=\"9993\" data-end=\"10013\">Casting facilities<\/li>\n<li data-section-id=\"11iaufq\" data-start=\"10014\" data-end=\"10034\">Rolling facilities<\/li>\n<li data-section-id=\"1uxjr27\" data-start=\"10035\" data-end=\"10070\">Section\/bar production facilities<\/li>\n<li data-section-id=\"h3k86m\" data-start=\"10071\" data-end=\"10138\">Heat-treatment or controlled cooling facilities, where applicable<\/li>\n<li data-section-id=\"1o42w6d\" data-start=\"10139\" data-end=\"10173\">Cutting and finishing facilities<\/li>\n<li data-section-id=\"p1igq8\" data-start=\"10174\" data-end=\"10204\">Chemical-analysis laboratory<\/li>\n<li data-section-id=\"8sfg9m\" data-start=\"10205\" data-end=\"10231\">Tensile-testing facility<\/li>\n<li data-section-id=\"1hhk463\" data-start=\"10232\" data-end=\"10255\">Bend-testing facility<\/li>\n<li data-section-id=\"1rzzc1g\" data-start=\"10256\" data-end=\"10281\">Impact-testing facility<\/li>\n<li data-section-id=\"sbkotd\" data-start=\"10282\" data-end=\"10316\">Dimensional inspection equipment<\/li>\n<li data-section-id=\"184x4v2\" data-start=\"10317\" data-end=\"10343\">Mass-measuring equipment<\/li>\n<li data-section-id=\"kpeh8n\" data-start=\"10344\" data-end=\"10364\">Calibration system<\/li>\n<li data-section-id=\"y8f4bh\" data-start=\"10365\" data-end=\"10392\">Quality-control personnel<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"10393\" data-end=\"10413\">Production records<\/li>\n<li data-section-id=\"x92i00\" data-start=\"10414\" data-end=\"10428\">Test records<\/li>\n<li data-section-id=\"1eaj5fd\" data-start=\"10429\" data-end=\"10453\">Heat\/cast traceability<\/li>\n<li data-section-id=\"z87z2a\" data-start=\"10454\" data-end=\"10488\">Marking and packing arrangements<\/li>\n<\/ul>\n<p data-start=\"10490\" data-end=\"10596\">The exact facilities required depend on the grades and product forms included in the proposed BIS licence.<\/p>\n<hr data-start=\"10598\" data-end=\"10601\" \/>\n<h1 data-section-id=\"10yduh5\" data-start=\"10603\" data-end=\"10669\">BIS Certification Process for Structural Weather Resistant Steel<\/h1>\n<h2 data-section-id=\"110du8d\" data-start=\"10671\" data-end=\"10715\">Step 1 \u2013 Product Applicability Assessment<\/h2>\n<p data-start=\"10717\" data-end=\"10778\">The manufacturer&#8217;s product is assessed against IS 11587:1986.<\/p>\n<p data-start=\"10780\" data-end=\"10804\">The assessment includes:<\/p>\n<ul data-start=\"10806\" data-end=\"10911\">\n<li data-section-id=\"170hry5\" data-start=\"10806\" data-end=\"10813\">Grade<\/li>\n<li data-section-id=\"1sta8lx\" data-start=\"10814\" data-end=\"10828\">Product form<\/li>\n<li data-section-id=\"178ku07\" data-start=\"10829\" data-end=\"10836\">Shape<\/li>\n<li data-section-id=\"1j4dcvh\" data-start=\"10837\" data-end=\"10843\">Size<\/li>\n<li data-section-id=\"1mm45vn\" data-start=\"10844\" data-end=\"10867\">Manufacturing process<\/li>\n<li data-section-id=\"18as0l2\" data-start=\"10868\" data-end=\"10882\">Intended use<\/li>\n<li data-section-id=\"1opo375\" data-start=\"10883\" data-end=\"10911\">Proposed BIS licence scope<\/li>\n<\/ul>\n<h2 data-section-id=\"1morawz\" data-start=\"10913\" data-end=\"10940\">Step 2 \u2013 Grade Selection<\/h2>\n<p data-start=\"10942\" data-end=\"10989\">The manufacturer identifies the required grade:<\/p>\n<p data-start=\"10991\" data-end=\"11056\"><strong data-start=\"10991\" data-end=\"11056\">WR-Fe 480A \/ WR-Fe 480B \/ WR-Fe 490H \/ WR-Fe 490C \/ WR-Fe 500<\/strong><\/p>\n<h2 data-section-id=\"28zgfw\" data-start=\"11058\" data-end=\"11093\">Step 3 \u2013 Product Form Assessment<\/h2>\n<p data-start=\"11095\" data-end=\"11159\">The manufacturer determines whether the proposed scope includes:<\/p>\n<ul data-start=\"11161\" data-end=\"11238\">\n<li data-section-id=\"34nthz\" data-start=\"11161\" data-end=\"11169\">Plates<\/li>\n<li data-section-id=\"68xqhg\" data-start=\"11170\" data-end=\"11178\">Sheets<\/li>\n<li data-section-id=\"66dson\" data-start=\"11179\" data-end=\"11187\">Strips<\/li>\n<li data-section-id=\"m12rle\" data-start=\"11188\" data-end=\"11198\">Sections<\/li>\n<li data-section-id=\"1j423d6\" data-start=\"11199\" data-end=\"11205\">Bars<\/li>\n<li data-section-id=\"11a47u7\" data-start=\"11206\" data-end=\"11238\">Other applicable product forms<\/li>\n<\/ul>\n<h2 data-section-id=\"161qqdg\" data-start=\"11240\" data-end=\"11268\">Step 4 \u2013 Product Grouping<\/h2>\n<p data-start=\"11270\" data-end=\"11337\">Grouping is assessed according to the Product Manual&#8217;s <strong data-start=\"11325\" data-end=\"11336\">Annex A<\/strong>.<\/p>\n<p data-start=\"11339\" data-end=\"11490\">The Product Manual provides separate grouping categories for flat products, sections, hollow sections and bars.<\/p>\n<h2 data-section-id=\"w3d716\" data-start=\"11492\" data-end=\"11529\">Step 5 \u2013 Documentation Preparation<\/h2>\n<p data-start=\"11531\" data-end=\"11602\">Technical, manufacturing and quality-control documentation is prepared.<\/p>\n<h2 data-section-id=\"1t4bp2l\" data-start=\"11604\" data-end=\"11634\">Step 6 \u2013 Sample Preparation<\/h2>\n<p data-start=\"11636\" data-end=\"11665\">The Product Manual specifies:<\/p>\n<p data-start=\"11667\" data-end=\"11705\"><strong data-start=\"11667\" data-end=\"11697\">Mechanical testing sample:<\/strong> 1 metre<\/p>\n<p data-start=\"11707\" data-end=\"11831\"><strong data-start=\"11707\" data-end=\"11735\">Chemical testing sample:<\/strong> five pieces of <strong data-start=\"11751\" data-end=\"11768\">50 mm \u00d7 50 mm<\/strong> or <strong data-start=\"11772\" data-end=\"11790\">100 g drilling<\/strong>.<\/p>\n<h2 data-section-id=\"1bh4pl2\" data-start=\"11833\" data-end=\"11863\">Step 7 \u2013 Laboratory Testing<\/h2>\n<p data-start=\"11865\" data-end=\"11935\">Representative samples are tested against the applicable requirements.<\/p>\n<h2 data-section-id=\"pat1r2\" data-start=\"11937\" data-end=\"11964\">Step 8 \u2013 BIS Application<\/h2>\n<p data-start=\"11966\" data-end=\"12066\">The manufacturer submits the BIS application with the required documents and supporting information.<\/p>\n<h2 data-section-id=\"x11gpr\" data-start=\"12068\" data-end=\"12098\">Step 9 \u2013 Factory Assessment<\/h2>\n<p data-start=\"12100\" data-end=\"12188\">BIS assesses manufacturing facilities, testing arrangements and quality-control systems.<\/p>\n<h2 data-section-id=\"1t4dkm\" data-start=\"12190\" data-end=\"12222\">Step 10 \u2013 Observation Closure<\/h2>\n<p data-start=\"12224\" data-end=\"12329\">Any observations raised during assessment are addressed through corrective action and supporting records.<\/p>\n<h2 data-section-id=\"12hjy2h\" data-start=\"12331\" data-end=\"12361\">Step 11 \u2013 BIS Licence Grant<\/h2>\n<p data-start=\"12363\" data-end=\"12449\">After successful conformity assessment, BIS grants the licence for the approved scope.<\/p>\n<h2 data-section-id=\"1b3m2u9\" data-start=\"12451\" data-end=\"12475\">Step 12 \u2013 ISI Marking<\/h2>\n<p data-start=\"12477\" data-end=\"12566\">The manufacturer can apply the Standard Mark to products covered by the approved licence.<\/p>\n<hr data-start=\"12568\" data-end=\"12571\" \/>\n<h1 data-section-id=\"1o6lj2z\" data-start=\"12573\" data-end=\"12613\">Testing Requirements for IS 11587:1986<\/h1>\n<p data-start=\"12615\" data-end=\"12702\">Testing is a critical part of BIS certification for weather resistant structural steel.<\/p>\n<p data-start=\"12704\" data-end=\"12764\">The BIS Product Manual identifies the following major tests:<\/p>\n<ul data-start=\"12766\" data-end=\"12919\">\n<li data-section-id=\"v16bzo\" data-start=\"12766\" data-end=\"12788\">Chemical composition<\/li>\n<li data-section-id=\"8bckeo\" data-start=\"12789\" data-end=\"12802\">Weldability<\/li>\n<li data-section-id=\"sudhwy\" data-start=\"12803\" data-end=\"12817\">Tensile test<\/li>\n<li data-section-id=\"4caeur\" data-start=\"12818\" data-end=\"12829\">Bend test<\/li>\n<li data-section-id=\"o1l5ek\" data-start=\"12830\" data-end=\"12843\">Impact test<\/li>\n<li data-section-id=\"18858xq\" data-start=\"12844\" data-end=\"12861\">Flattening test<\/li>\n<li data-section-id=\"1g7qg16\" data-start=\"12862\" data-end=\"12884\">Freedom from defects<\/li>\n<li data-section-id=\"1f5i8ey\" data-start=\"12885\" data-end=\"12912\">Dimensions and tolerances<\/li>\n<li data-section-id=\"1j3zlok\" data-start=\"12913\" data-end=\"12919\">Mass<\/li>\n<\/ul>\n<p data-start=\"12921\" data-end=\"13039\">The actual tests applicable to a product depend on its grade and product form.<\/p>\n<hr data-start=\"13041\" data-end=\"13044\" \/>\n<h1 data-section-id=\"xjen0p\" data-start=\"13046\" data-end=\"13084\">Chemical Composition and Weldability<\/h1>\n<p data-start=\"13086\" data-end=\"13176\">Chemical composition is one of the most important requirements of weather resistant steel.<\/p>\n<p data-start=\"13178\" data-end=\"13371\">BIS&#8217;s technical summary states that IS 11587 specifies the chemical composition of the different grades and includes requirements related to weldability.<\/p>\n<p data-start=\"13373\" data-end=\"13425\">The Product Manual identifies chemical analysis for:<\/p>\n<ul data-start=\"13427\" data-end=\"13509\">\n<li data-section-id=\"1uyczyz\" data-start=\"13427\" data-end=\"13435\">Carbon<\/li>\n<li data-section-id=\"1kt0a2l\" data-start=\"13436\" data-end=\"13445\">Sulphur<\/li>\n<li data-section-id=\"1nus0t1\" data-start=\"13446\" data-end=\"13455\">Silicon<\/li>\n<li data-section-id=\"t8y5ox\" data-start=\"13456\" data-end=\"13467\">Manganese<\/li>\n<li data-section-id=\"1uyh4rz\" data-start=\"13468\" data-end=\"13480\">Phosphorus<\/li>\n<li data-section-id=\"aooen6\" data-start=\"13481\" data-end=\"13491\">Chromium<\/li>\n<li data-section-id=\"1t8ebim\" data-start=\"13492\" data-end=\"13500\">Nickel<\/li>\n<li data-section-id=\"1uwt7rn\" data-start=\"13501\" data-end=\"13509\">Copper<\/li>\n<\/ul>\n<p data-start=\"13511\" data-end=\"13559\">The exact limits depend on the applicable grade.<\/p>\n<p data-start=\"13561\" data-end=\"13629\">The laboratory equipment list includes instrumental methods such as:<\/p>\n<ul data-start=\"13631\" data-end=\"13800\">\n<li data-section-id=\"1jzhacv\" data-start=\"13631\" data-end=\"13663\">Atomic absorption spectrometry<\/li>\n<li data-section-id=\"17r569g\" data-start=\"13664\" data-end=\"13708\">Inductively coupled plasma atomic emission<\/li>\n<li data-section-id=\"1mzxl9z\" data-start=\"13709\" data-end=\"13755\">Inductively coupled plasma mass spectrometry<\/li>\n<li data-section-id=\"mtz968\" data-start=\"13756\" data-end=\"13800\">Spark source optical emission spectrometry<\/li>\n<\/ul>\n<p data-start=\"13802\" data-end=\"13882\">as well as established chemical methods.<\/p>\n<hr data-start=\"13884\" data-end=\"13887\" \/>\n<h1 data-section-id=\"6su3it\" data-start=\"13889\" data-end=\"13897\">Carbon<\/h1>\n<p data-start=\"13899\" data-end=\"13949\">Carbon affects strength, hardness and weldability.<\/p>\n<p data-start=\"13951\" data-end=\"14080\">Because IS 11587 is intended for structural applications, carbon content has to be controlled along with other alloying elements.<\/p>\n<p data-start=\"14082\" data-end=\"14140\">The applicable carbon limit depends on the selected grade.<\/p>\n<hr data-start=\"14142\" data-end=\"14145\" \/>\n<h1 data-section-id=\"rx0j0p\" data-start=\"14147\" data-end=\"14170\">Silicon and Manganese<\/h1>\n<p data-start=\"14172\" data-end=\"14251\">Silicon and manganese are important constituents of structural steel chemistry.<\/p>\n<p data-start=\"14253\" data-end=\"14393\">Their concentrations are controlled according to the specified grade to achieve the required balance of strength, toughness and weldability.<\/p>\n<hr data-start=\"14395\" data-end=\"14398\" \/>\n<h1 data-section-id=\"11i8yxr\" data-start=\"14400\" data-end=\"14424\">Sulphur and Phosphorus<\/h1>\n<p data-start=\"14426\" data-end=\"14559\">Sulphur and phosphorus are controlled because excessive levels can adversely affect toughness, weldability and general steel quality.<\/p>\n<p data-start=\"14561\" data-end=\"14643\">The applicable limits must be checked against the relevant grade in IS 11587:1986.<\/p>\n<hr data-start=\"14645\" data-end=\"14648\" \/>\n<h1 data-section-id=\"1wp0wdy\" data-start=\"14650\" data-end=\"14679\">Chromium, Nickel and Copper<\/h1>\n<p data-start=\"14681\" data-end=\"14772\">Chromium, nickel and copper are particularly relevant to weather-resistant steel chemistry.<\/p>\n<p data-start=\"14774\" data-end=\"14889\">Controlled alloying contributes to the steel&#8217;s atmospheric corrosion resistance and required structural properties.<\/p>\n<p data-start=\"14891\" data-end=\"15050\">The BIS Product Manual specifically identifies these elements in the chemical-analysis equipment and testing framework.<\/p>\n<hr data-start=\"15052\" data-end=\"15055\" \/>\n<h1 data-section-id=\"1ilafks\" data-start=\"15057\" data-end=\"15071\">Tensile Test<\/h1>\n<p data-start=\"15073\" data-end=\"15164\">Tensile testing is required to determine the mechanical properties of the structural steel.<\/p>\n<p data-start=\"15166\" data-end=\"15200\">The BIS Product Manual identifies:<\/p>\n<p data-start=\"15202\" data-end=\"15241\"><strong data-start=\"15202\" data-end=\"15241\">Universal Testing Machine (UTM\/TTM)<\/strong><\/p>\n<p data-start=\"15243\" data-end=\"15263\">for tensile testing.<\/p>\n<p data-start=\"15265\" data-end=\"15292\">The test is carried out on:<\/p>\n<p data-start=\"15294\" data-end=\"15364\"><strong data-start=\"15294\" data-end=\"15323\">1 sample per control unit<\/strong>.<\/p>\n<p data-start=\"15366\" data-end=\"15413\">Mechanical properties include requirements for:<\/p>\n<ul data-start=\"15415\" data-end=\"15463\">\n<li data-section-id=\"1r26z8w\" data-start=\"15415\" data-end=\"15431\">Yield strength<\/li>\n<li data-section-id=\"1j94mjl\" data-start=\"15432\" data-end=\"15450\">Tensile strength<\/li>\n<li data-section-id=\"15qwr16\" data-start=\"15451\" data-end=\"15463\">Elongation<\/li>\n<\/ul>\n<p data-start=\"15465\" data-end=\"15618\">BIS&#8217;s technical summary confirms that these mechanical properties are specified for the various forms of product.<\/p>\n<hr data-start=\"15620\" data-end=\"15623\" \/>\n<h1 data-section-id=\"1gqh4jh\" data-start=\"15625\" data-end=\"15661\">Special Requirement for WR-Fe 490H<\/h1>\n<p data-start=\"15663\" data-end=\"15914\">For <strong data-start=\"15667\" data-end=\"15724\">WR-Fe 490H steel sheet and strip below 3 mm thickness<\/strong>, the BIS Product Manual specifies that a tensile strength of <strong data-start=\"15786\" data-end=\"15807\">510 N\/mm\u00b2 or over<\/strong> is applicable by agreement between the purchaser and manufacturer.<\/p>\n<p data-start=\"15916\" data-end=\"16005\">This is an important point for manufacturers supplying thin sheet or strip in this grade.<\/p>\n<hr data-start=\"16007\" data-end=\"16010\" \/>\n<h1 data-section-id=\"e6l0nx\" data-start=\"16012\" data-end=\"16023\">Bend Test<\/h1>\n<p data-start=\"16025\" data-end=\"16099\">Bend testing evaluates the ductility and bending performance of the steel.<\/p>\n<p data-start=\"16101\" data-end=\"16130\">The Product Manual specifies:<\/p>\n<p data-start=\"16132\" data-end=\"16219\"><strong data-start=\"16132\" data-end=\"16161\">1 sample per control unit<\/strong> for bend testing.<\/p>\n<p data-start=\"16221\" data-end=\"16395\">The BIS technical summary explains that the standard specifies bending angle and internal bend diameter for the various product forms.<\/p>\n<p data-start=\"16397\" data-end=\"16567\">For <strong data-start=\"16401\" data-end=\"16415\">WR-Fe 490C<\/strong>, the Product Manual states that bend testing is optional and is performed only when specified by the purchaser.<\/p>\n<hr data-start=\"16569\" data-end=\"16572\" \/>\n<h1 data-section-id=\"gdgeia\" data-start=\"16574\" data-end=\"16587\">Impact Test<\/h1>\n<p data-start=\"16589\" data-end=\"16660\">Impact testing evaluates toughness under the specified test conditions.<\/p>\n<p data-start=\"16662\" data-end=\"16690\">The Product Manual requires:<\/p>\n<p data-start=\"16692\" data-end=\"16722\"><strong data-start=\"16692\" data-end=\"16722\">3 samples per control unit<\/strong><\/p>\n<p data-start=\"16724\" data-end=\"16784\">for the impact test.<\/p>\n<p data-start=\"16786\" data-end=\"16903\">For <strong data-start=\"16790\" data-end=\"16819\">WR-Fe 480A and WR-Fe 480B<\/strong>, the impact test is carried out when agreed between the purchaser and manufacturer.<\/p>\n<p data-start=\"16905\" data-end=\"17056\">For <strong data-start=\"16909\" data-end=\"16923\">WR-Fe 490H<\/strong>, the impact values and acceptance criteria are to be agreed between the contracting parties.<\/p>\n<p data-start=\"17058\" data-end=\"17176\">Therefore, manufacturers should clearly understand the applicable contractual and product requirements before testing.<\/p>\n<hr data-start=\"17178\" data-end=\"17181\" \/>\n<h1 data-section-id=\"ulkahc\" data-start=\"17183\" data-end=\"17200\">Flattening Test<\/h1>\n<p data-start=\"17202\" data-end=\"17285\">The Product Manual identifies <strong data-start=\"17232\" data-end=\"17254\">flattening testing<\/strong> under Clause 11 and specifies:<\/p>\n<p data-start=\"17287\" data-end=\"17357\"><strong data-start=\"17287\" data-end=\"17316\">1 sample per control unit<\/strong>.<\/p>\n<p data-start=\"17359\" data-end=\"17446\">The exact applicability depends on the relevant product form and standard requirements.<\/p>\n<hr data-start=\"17448\" data-end=\"17451\" \/>\n<h1 data-section-id=\"axmbes\" data-start=\"17453\" data-end=\"17475\">Freedom from Defects<\/h1>\n<p data-start=\"17477\" data-end=\"17540\">The steel product must be appropriately controlled for defects.<\/p>\n<p data-start=\"17542\" data-end=\"17571\">The Product Manual specifies:<\/p>\n<p data-start=\"17573\" data-end=\"17598\"><strong data-start=\"17573\" data-end=\"17598\">Each item \u2013 Each item<\/strong><\/p>\n<p data-start=\"17600\" data-end=\"17676\">for freedom-from-defects inspection.<\/p>\n<p data-start=\"17678\" data-end=\"17726\">Inspection can include identifying unacceptable:<\/p>\n<ul data-start=\"17728\" data-end=\"17800\">\n<li data-section-id=\"1v9yjkz\" data-start=\"17728\" data-end=\"17736\">Cracks<\/li>\n<li data-section-id=\"1pcnrsr\" data-start=\"17737\" data-end=\"17754\">Surface defects<\/li>\n<li data-section-id=\"1efam75\" data-start=\"17755\" data-end=\"17768\">Laminations<\/li>\n<li data-section-id=\"1frrk65\" data-start=\"17769\" data-end=\"17800\">Other harmful discontinuities<\/li>\n<\/ul>\n<p data-start=\"17802\" data-end=\"17867\">The exact acceptance criteria should be taken from IS 11587:1986.<\/p>\n<hr data-start=\"17869\" data-end=\"17872\" \/>\n<h1 data-section-id=\"1qxdss4\" data-start=\"17874\" data-end=\"17901\">Dimensions and Tolerances<\/h1>\n<p data-start=\"17903\" data-end=\"18053\">Dimensional accuracy is essential for structural steel because the finished material must match the requirements of structural design and fabrication.<\/p>\n<p data-start=\"18055\" data-end=\"18183\">The BIS Product Manual identifies dimensions and tolerances under Clauses 13 and 14 and references relevant standards including:<\/p>\n<ul data-start=\"18185\" data-end=\"18299\">\n<li data-section-id=\"by68fw\" data-start=\"18185\" data-end=\"18194\">IS 1852<\/li>\n<li data-section-id=\"135xt0o\" data-start=\"18195\" data-end=\"18205\">IS 12779<\/li>\n<li data-section-id=\"1qs7876\" data-start=\"18206\" data-end=\"18214\">IS 808<\/li>\n<li data-section-id=\"by62ie\" data-start=\"18215\" data-end=\"18224\">IS 1173<\/li>\n<li data-section-id=\"by601i\" data-start=\"18225\" data-end=\"18234\">IS 1252<\/li>\n<li data-section-id=\"by646v\" data-start=\"18235\" data-end=\"18244\">IS 1730<\/li>\n<li data-section-id=\"by646t\" data-start=\"18245\" data-end=\"18254\">IS 1732<\/li>\n<li data-section-id=\"by68da\" data-start=\"18255\" data-end=\"18264\">IS 1863<\/li>\n<li data-section-id=\"by5cba\" data-start=\"18265\" data-end=\"18274\">IS 2314<\/li>\n<li data-section-id=\"by4ptl\" data-start=\"18275\" data-end=\"18284\">IS 3954<\/li>\n<li data-section-id=\"amw8oq\" data-start=\"18285\" data-end=\"18299\">IS\/ISO 16162<\/li>\n<\/ul>\n<p data-start=\"18301\" data-end=\"18408\">The inspection requirement is specified as <strong data-start=\"18344\" data-end=\"18367\">adequate inspection<\/strong>.<\/p>\n<hr data-start=\"18410\" data-end=\"18413\" \/>\n<h1 data-section-id=\"1hth5u2\" data-start=\"18415\" data-end=\"18421\">Mass<\/h1>\n<p data-start=\"18423\" data-end=\"18475\">Mass is also identified as a product characteristic.<\/p>\n<p data-start=\"18477\" data-end=\"18592\">The Product Manual specifies a <strong data-start=\"18508\" data-end=\"18528\">weighing machine<\/strong> for mass determination.<\/p>\n<p data-start=\"18594\" data-end=\"18722\">Accurate mass and dimensional records are important for product identification and commercial as well as technical requirements.<\/p>\n<hr data-start=\"18724\" data-end=\"18727\" \/>\n<h1 data-section-id=\"1yo68z9\" data-start=\"18729\" data-end=\"18765\">Product Grouping for IS 11587:1986<\/h1>\n<p data-start=\"18767\" data-end=\"18895\">Product grouping is important when a manufacturer wants to include multiple product forms, grades and sizes under a BIS licence.<\/p>\n<p data-start=\"18897\" data-end=\"19000\">The BIS Product Manual provides four major grouping categories.<\/p>\n<h2 data-section-id=\"3o9p3z\" data-start=\"19002\" data-end=\"19028\">Group 1 \u2013 Flat Products<\/h2>\n<p data-start=\"19030\" data-end=\"19044\">This includes:<\/p>\n<ul data-start=\"19046\" data-end=\"19151\">\n<li data-section-id=\"34nthz\" data-start=\"19046\" data-end=\"19054\">Plates<\/li>\n<li data-section-id=\"68xqhg\" data-start=\"19055\" data-end=\"19063\">Sheets<\/li>\n<li data-section-id=\"66dson\" data-start=\"19064\" data-end=\"19072\">Strips<\/li>\n<li data-section-id=\"1k5q55p\" data-start=\"19073\" data-end=\"19085\">Bulb flats<\/li>\n<li data-section-id=\"a5b1k7\" data-start=\"19086\" data-end=\"19122\">Flat plate for ship-hull structure<\/li>\n<li data-section-id=\"4l0yzs\" data-start=\"19123\" data-end=\"19151\">Other listed flat products<\/li>\n<\/ul>\n<p data-start=\"19153\" data-end=\"19261\">For flat products, <strong data-start=\"19172\" data-end=\"19203\">one sample of any size\/type<\/strong> can be drawn to cover all sizes\/types being manufactured.<\/p>\n<p data-start=\"19263\" data-end=\"19375\">However, <strong data-start=\"19272\" data-end=\"19302\">one sample from each grade<\/strong> is required to cover that grade.<\/p>\n<h2 data-section-id=\"1frjqrl\" data-start=\"19377\" data-end=\"19398\">Group 2 \u2013 Sections<\/h2>\n<p data-start=\"19400\" data-end=\"19437\">This group includes products such as:<\/p>\n<ul data-start=\"19439\" data-end=\"19607\">\n<li data-section-id=\"16y6kz4\" data-start=\"19439\" data-end=\"19446\">Beams<\/li>\n<li data-section-id=\"5wk9d9\" data-start=\"19447\" data-end=\"19456\">Columns<\/li>\n<li data-section-id=\"1ynjms8\" data-start=\"19457\" data-end=\"19467\">Channels<\/li>\n<li data-section-id=\"1w6bc8q\" data-start=\"19468\" data-end=\"19476\">Angles<\/li>\n<li data-section-id=\"5y6g4j\" data-start=\"19477\" data-end=\"19490\">Bulb angles<\/li>\n<li data-section-id=\"1brtqw5\" data-start=\"19491\" data-end=\"19514\">Sheet-piling sections<\/li>\n<li data-section-id=\"mzbr64\" data-start=\"19515\" data-end=\"19536\">Track shoe sections<\/li>\n<li data-section-id=\"6mimcv\" data-start=\"19537\" data-end=\"19572\">Parallel beam and column sections<\/li>\n<li data-section-id=\"rwjshq\" data-start=\"19573\" data-end=\"19583\">Tee bars<\/li>\n<li data-section-id=\"dtvrh1\" data-start=\"19584\" data-end=\"19607\">Other listed sections<\/li>\n<\/ul>\n<p data-start=\"19609\" data-end=\"19815\">One sample of any size\/type of section can be drawn to cover all sizes\/types being manufactured, while <strong data-start=\"19712\" data-end=\"19742\">one sample from each grade<\/strong> is required to cover that grade.<\/p>\n<h2 data-section-id=\"1ois7y7\" data-start=\"19817\" data-end=\"19845\">Group 3 \u2013 Hollow Sections<\/h2>\n<p data-start=\"19847\" data-end=\"20018\">For hollow sections, the Product Manual provides similar grouping based on one representative size\/type and grade-specific testing.<\/p>\n<h2 data-section-id=\"1fkafnj\" data-start=\"20020\" data-end=\"20037\">Group 4 \u2013 Bars<\/h2>\n<p data-start=\"20039\" data-end=\"20059\">This group includes:<\/p>\n<ul data-start=\"20061\" data-end=\"20087\">\n<li data-section-id=\"tejtwo\" data-start=\"20061\" data-end=\"20073\">Round bars<\/li>\n<li data-section-id=\"1620ouj\" data-start=\"20074\" data-end=\"20087\">Square bars<\/li>\n<\/ul>\n<p data-start=\"20089\" data-end=\"20302\">One sample of any size and shape of bars can be drawn to cover all sizes and shapes being manufactured, while <strong data-start=\"20199\" data-end=\"20229\">one sample from each grade<\/strong> is required to cover that grade.<\/p>\n<p data-start=\"20304\" data-end=\"20624\">The Product Manual further states that while granting or adding varieties, requisite manufacturing facilities and testing equipment must be available. During licence operation, samples of varieties covered by the licence are to be drawn for testing in rotation as far as possible.<\/p>\n<hr data-start=\"20626\" data-end=\"20629\" \/>\n<h1 data-section-id=\"1agk8md\" data-start=\"20631\" data-end=\"20658\">Raw Material Requirements<\/h1>\n<p data-start=\"20660\" data-end=\"20690\">The BIS Product Manual states:<\/p>\n<p data-start=\"20692\" data-end=\"20774\"><strong data-start=\"20692\" data-end=\"20734\">Raw Material: No specific requirement.<\/strong><\/p>\n<p data-start=\"20776\" data-end=\"20841\">This does not mean manufacturers can ignore raw-material control.<\/p>\n<p data-start=\"20843\" data-end=\"20890\">Manufacturers should maintain records covering:<\/p>\n<ul data-start=\"20892\" data-end=\"21060\">\n<li data-section-id=\"19bnmyf\" data-start=\"20892\" data-end=\"20913\">Raw-material source<\/li>\n<li data-section-id=\"hdxszd\" data-start=\"20914\" data-end=\"20932\">Heat\/cast number<\/li>\n<li data-section-id=\"12qimu\" data-start=\"20933\" data-end=\"20955\">Material certificate<\/li>\n<li data-section-id=\"m8jnps\" data-start=\"20956\" data-end=\"20977\">Incoming inspection<\/li>\n<li data-section-id=\"v16bzo\" data-start=\"20978\" data-end=\"21000\">Chemical composition<\/li>\n<li data-section-id=\"gu762l\" data-start=\"21001\" data-end=\"21019\">Purchase records<\/li>\n<li data-section-id=\"zc0p3f\" data-start=\"21020\" data-end=\"21034\">Traceability<\/li>\n<li data-section-id=\"1or2dfx\" data-start=\"21035\" data-end=\"21060\">Production heat records<\/li>\n<\/ul>\n<p data-start=\"21062\" data-end=\"21160\">Such controls are essential for maintaining consistent steel chemistry and mechanical performance.<\/p>\n<hr data-start=\"21162\" data-end=\"21165\" \/>\n<h1 data-section-id=\"9gfi2x\" data-start=\"21167\" data-end=\"21229\">Manufacturing Process for Structural Weather Resistant Steel<\/h1>\n<p data-start=\"21231\" data-end=\"21275\">A typical manufacturing process may include:<\/p>\n<ol data-start=\"21277\" data-end=\"21648\">\n<li data-section-id=\"1xjq2ox\" data-start=\"21277\" data-end=\"21304\">Raw-material preparation<\/li>\n<li data-section-id=\"l8ug5l\" data-start=\"21305\" data-end=\"21315\">Melting<\/li>\n<li data-section-id=\"jyh2vf\" data-start=\"21316\" data-end=\"21350\">Chemical composition adjustment<\/li>\n<li data-section-id=\"19jvl49\" data-start=\"21351\" data-end=\"21362\">Refining<\/li>\n<li data-section-id=\"urhato\" data-start=\"21363\" data-end=\"21380\">Ladle analysis<\/li>\n<li data-section-id=\"12jonko\" data-start=\"21381\" data-end=\"21391\">Casting<\/li>\n<li data-section-id=\"1q5pp70\" data-start=\"21392\" data-end=\"21418\">Slab\/billet preparation<\/li>\n<li data-section-id=\"9xjj5o\" data-start=\"21419\" data-end=\"21431\">Reheating<\/li>\n<li data-section-id=\"hh49wv\" data-start=\"21432\" data-end=\"21442\">Rolling<\/li>\n<li data-section-id=\"17ptxgj\" data-start=\"21443\" data-end=\"21483\">Controlled cooling, where applicable<\/li>\n<li data-section-id=\"6uuwu5\" data-start=\"21484\" data-end=\"21495\">Cutting<\/li>\n<li data-section-id=\"1wpgwhn\" data-start=\"21496\" data-end=\"21509\">Finishing<\/li>\n<li data-section-id=\"43ndqi\" data-start=\"21510\" data-end=\"21536\">Dimensional inspection<\/li>\n<li data-section-id=\"lbfb0\" data-start=\"21537\" data-end=\"21557\">Chemical testing<\/li>\n<li data-section-id=\"1nhk2oi\" data-start=\"21558\" data-end=\"21580\">Mechanical testing<\/li>\n<li data-section-id=\"1svsgiv\" data-start=\"21581\" data-end=\"21603\">Surface inspection<\/li>\n<li data-section-id=\"2ezlun\" data-start=\"21604\" data-end=\"21624\">Final inspection<\/li>\n<li data-section-id=\"g5tgor\" data-start=\"21625\" data-end=\"21636\">Packing<\/li>\n<li data-section-id=\"1lq9onq\" data-start=\"21637\" data-end=\"21648\">Marking<\/li>\n<\/ol>\n<p data-start=\"21650\" data-end=\"21727\">The actual process depends on the manufacturer&#8217;s technology and product form.<\/p>\n<hr data-start=\"21729\" data-end=\"21732\" \/>\n<h1 data-section-id=\"1k69l65\" data-start=\"21734\" data-end=\"21786\">BIS Factory Inspection for Weather Resistant Steel<\/h1>\n<p data-start=\"21788\" data-end=\"21849\">Factory assessment is an important part of BIS certification.<\/p>\n<p data-start=\"21851\" data-end=\"21894\">During factory inspection, BIS may examine:<\/p>\n<h3 data-section-id=\"1wm5k84\" data-start=\"21896\" data-end=\"21923\">Steelmaking and Casting<\/h3>\n<p data-start=\"21925\" data-end=\"22022\">Where applicable, the manufacturer should demonstrate suitable process controls and traceability.<\/p>\n<h3 data-section-id=\"1jymf88\" data-start=\"22024\" data-end=\"22046\">Rolling Facilities<\/h3>\n<p data-start=\"22048\" data-end=\"22119\">Machinery used to manufacture plates, sheets, strips, sections or bars.<\/p>\n<h3 data-section-id=\"nysxfa\" data-start=\"22121\" data-end=\"22145\">Finishing Facilities<\/h3>\n<p data-start=\"22147\" data-end=\"22203\">Cutting, sizing, straightening and finishing operations.<\/p>\n<h3 data-section-id=\"f8uig1\" data-start=\"22205\" data-end=\"22228\">Chemical Laboratory<\/h3>\n<p data-start=\"22230\" data-end=\"22295\">Facilities for chemical analysis and weldability-related testing.<\/p>\n<h3 data-section-id=\"13u8mbc\" data-start=\"22297\" data-end=\"22330\">Mechanical Testing Laboratory<\/h3>\n<p data-start=\"22332\" data-end=\"22559\">The Product Manual identifies a Universal Testing Machine for tensile testing, mandrels for bend tests, a Charpy impact tester for impact testing and UTM attachments for flattening tests.<\/p>\n<h3 data-section-id=\"1if4tad\" data-start=\"22561\" data-end=\"22587\">Dimensional Inspection<\/h3>\n<p data-start=\"22589\" data-end=\"22639\">The Product Manual identifies equipment including:<\/p>\n<ul data-start=\"22641\" data-end=\"22830\">\n<li data-section-id=\"1x6r6op\" data-start=\"22641\" data-end=\"22658\">Vernier caliper<\/li>\n<li data-section-id=\"2pnjll\" data-start=\"22659\" data-end=\"22671\">Micrometer<\/li>\n<li data-section-id=\"oxqnnf\" data-start=\"22672\" data-end=\"22685\">Steel scale<\/li>\n<li data-section-id=\"1mabdrq\" data-start=\"22686\" data-end=\"22698\">Try square<\/li>\n<li data-section-id=\"bvr08i\" data-start=\"22699\" data-end=\"22714\">Radius gauges<\/li>\n<li data-section-id=\"btej02\" data-start=\"22715\" data-end=\"22730\">Filler gauges<\/li>\n<li data-section-id=\"1ta9z3b\" data-start=\"22731\" data-end=\"22745\">Depth gauges<\/li>\n<li data-section-id=\"1crhxfi\" data-start=\"22746\" data-end=\"22762\">Straight edges<\/li>\n<li data-section-id=\"cwxxus\" data-start=\"22763\" data-end=\"22781\">Magnetic V-block<\/li>\n<li data-section-id=\"jhbthl\" data-start=\"22782\" data-end=\"22800\">Angle protractor<\/li>\n<li data-section-id=\"1yahezd\" data-start=\"22801\" data-end=\"22830\">Inside and outside calipers<\/li>\n<\/ul>\n<p data-start=\"22832\" data-end=\"22871\">\n<h3 data-section-id=\"1e1028w\" data-start=\"22873\" data-end=\"22893\">Mass Measurement<\/h3>\n<p data-start=\"22895\" data-end=\"22989\">A weighing machine is identified for mass measurement.<\/p>\n<h3 data-section-id=\"wzkpnw\" data-start=\"22991\" data-end=\"23006\">Calibration<\/h3>\n<p data-start=\"23008\" data-end=\"23187\">All applicable testing equipment and measuring instruments must be appropriately checked, verified and calibrated, with records maintained.<\/p>\n<h3 data-section-id=\"1kypjpx\" data-start=\"23189\" data-end=\"23208\">Quality Records<\/h3>\n<p data-start=\"23210\" data-end=\"23340\">The manufacturer must maintain test records for tests carried out to establish conformity.<\/p>\n<hr data-start=\"23342\" data-end=\"23345\" \/>\n<h1 data-section-id=\"1azfpmh\" data-start=\"23347\" data-end=\"23381\">Scheme of Inspection and Testing<\/h1>\n<p data-start=\"23383\" data-end=\"23459\">The BIS Product Manual includes a detailed Scheme of Inspection and Testing.<\/p>\n<p data-start=\"23461\" data-end=\"23473\">It requires:<\/p>\n<ul data-start=\"23475\" data-end=\"23736\">\n<li data-section-id=\"17q1xr6\" data-start=\"23475\" data-end=\"23519\">A suitably equipped and staffed laboratory<\/li>\n<li data-section-id=\"aahac5\" data-start=\"23520\" data-end=\"23576\">Periodic checking and calibration of testing equipment<\/li>\n<li data-section-id=\"13q15as\" data-start=\"23577\" data-end=\"23606\">Maintenance of test records<\/li>\n<li data-section-id=\"19tywva\" data-start=\"23607\" data-end=\"23625\">Standard Marking<\/li>\n<li data-section-id=\"1697yor\" data-start=\"23626\" data-end=\"23642\">Proper packing<\/li>\n<li data-section-id=\"18ox2q6\" data-start=\"23643\" data-end=\"23672\">Control-unit identification<\/li>\n<li data-section-id=\"dzo0ww\" data-start=\"23673\" data-end=\"23690\">Routine testing<\/li>\n<li data-section-id=\"1ff0vxd\" data-start=\"23691\" data-end=\"23736\">Proper treatment of non-conforming products<\/li>\n<\/ul>\n<p data-start=\"23738\" data-end=\"23785\">The Product Manual defines the control unit as:<\/p>\n<p data-start=\"23787\" data-end=\"23990\"><strong data-start=\"23787\" data-end=\"23950\">The entire quantity of Structural Weather Resistant Steel of the same grade and form, manufactured from the same cast\/heat under identical conditions in a day.<\/strong><\/p>\n<p data-start=\"23992\" data-end=\"24065\">This definition is important for production planning and routine testing.<\/p>\n<hr data-start=\"24067\" data-end=\"24070\" \/>\n<h1 data-section-id=\"1kjqkle\" data-start=\"24072\" data-end=\"24102\">Routine Testing Requirements<\/h1>\n<p data-start=\"24104\" data-end=\"24157\">The Product Manual identifies the following controls:<\/p>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"24159\" data-end=\"24630\">\n<thead data-start=\"24159\" data-end=\"24197\">\n<tr data-start=\"24159\" data-end=\"24197\">\n<th class=\"last:pe-10\" data-start=\"24159\" data-end=\"24173\" data-col-size=\"sm\">Requirement<\/th>\n<th class=\"last:pe-10\" data-start=\"24173\" data-end=\"24197\" data-col-size=\"md\">Sampling \/ Frequency<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"24208\" data-end=\"24630\">\n<tr data-start=\"24208\" data-end=\"24288\">\n<td data-start=\"24208\" data-end=\"24225\" data-col-size=\"sm\">Ladle Analysis<\/td>\n<td data-start=\"24225\" data-end=\"24288\" data-col-size=\"md\">One each heat for manufacturers with steelmaking facilities<\/td>\n<\/tr>\n<tr data-start=\"24289\" data-end=\"24355\">\n<td data-start=\"24289\" data-end=\"24308\" data-col-size=\"sm\">Product Analysis<\/td>\n<td data-start=\"24308\" data-end=\"24355\" data-col-size=\"md\">Applicable according to manufacturing route<\/td>\n<\/tr>\n<tr data-start=\"24356\" data-end=\"24402\">\n<td data-start=\"24356\" data-end=\"24371\" data-col-size=\"sm\">Tensile Test<\/td>\n<td data-start=\"24371\" data-end=\"24402\" data-col-size=\"md\">1 sample every control unit<\/td>\n<\/tr>\n<tr data-start=\"24403\" data-end=\"24446\">\n<td data-start=\"24403\" data-end=\"24415\" data-col-size=\"sm\">Bend Test<\/td>\n<td data-start=\"24415\" data-end=\"24446\" data-col-size=\"md\">1 sample every control unit<\/td>\n<\/tr>\n<tr data-start=\"24447\" data-end=\"24493\">\n<td data-start=\"24447\" data-end=\"24461\" data-col-size=\"sm\">Impact Test<\/td>\n<td data-start=\"24461\" data-end=\"24493\" data-col-size=\"md\">3 samples every control unit<\/td>\n<\/tr>\n<tr data-start=\"24494\" data-end=\"24543\">\n<td data-start=\"24494\" data-end=\"24512\" data-col-size=\"sm\">Flattening Test<\/td>\n<td data-start=\"24512\" data-end=\"24543\" data-col-size=\"md\">1 sample every control unit<\/td>\n<\/tr>\n<tr data-start=\"24544\" data-end=\"24580\">\n<td data-start=\"24544\" data-end=\"24567\" data-col-size=\"sm\">Freedom from Defects<\/td>\n<td data-start=\"24567\" data-end=\"24580\" data-col-size=\"md\">Each item<\/td>\n<\/tr>\n<tr data-start=\"24581\" data-end=\"24630\">\n<td data-start=\"24581\" data-end=\"24607\" data-col-size=\"sm\">Dimensions &amp; Tolerances<\/td>\n<td data-start=\"24607\" data-end=\"24630\" data-col-size=\"md\">Adequate inspection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"24632\" data-end=\"24671\">\n<p data-start=\"24673\" data-end=\"24897\">The Product Manual also notes that the levels of control are recommendatory in nature and that a manufacturer may submit its own justified levels of control for approval by the Bureau.<\/p>\n<hr data-start=\"24899\" data-end=\"24902\" \/>\n<h1 data-section-id=\"1ubl5u8\" data-start=\"24904\" data-end=\"24932\">Chemical Testing Frequency<\/h1>\n<p data-start=\"24934\" data-end=\"25044\">For manufacturers with steelmaking facilities, the Product Manual identifies <strong data-start=\"25011\" data-end=\"25043\">ladle analysis for each heat<\/strong>.<\/p>\n<p data-start=\"25046\" data-end=\"25116\">Product analysis requirements depend on the manufacturing arrangement:<\/p>\n<ul data-start=\"25118\" data-end=\"25374\">\n<li data-section-id=\"1e7yted\" data-start=\"25118\" data-end=\"25219\">No product analysis requirement in the specified case for manufacturers with steelmaking facilities<\/li>\n<li data-section-id=\"eapj1z\" data-start=\"25220\" data-end=\"25374\">One product-analysis sample from each cast for manufacturers feeding rolling mills through reheating furnaces, subject to the note in the Product Manual<\/li>\n<\/ul>\n<p data-start=\"25376\" data-end=\"25602\">The Product Manual also provides an exception where product-analysis testing is not required if the material is <strong data-start=\"25488\" data-end=\"25561\">ISI marked and received with a test certificate indicating conformity<\/strong>.<\/p>\n<hr data-start=\"25604\" data-end=\"25607\" \/>\n<h1 data-section-id=\"ix1iw9\" data-start=\"25609\" data-end=\"25640\">Test Certificate Requirements<\/h1>\n<p data-start=\"25642\" data-end=\"25766\">The BIS Product Manual requires a test certificate for each consignment of BIS-certified Structural Weather Resistant Steel.<\/p>\n<p data-start=\"25768\" data-end=\"25826\">The test certificate should contain information including:<\/p>\n<ul data-start=\"25828\" data-end=\"25906\">\n<li data-section-id=\"1v02m4m\" data-start=\"25828\" data-end=\"25843\">Standard Mark<\/li>\n<li data-section-id=\"1tu1gr2\" data-start=\"25844\" data-end=\"25857\">Cast number<\/li>\n<li data-section-id=\"1j4dcvh\" data-start=\"25858\" data-end=\"25864\">Size<\/li>\n<li data-section-id=\"zy1zez\" data-start=\"25865\" data-end=\"25877\">Dimensions<\/li>\n<li data-section-id=\"1yu6mqz\" data-start=\"25878\" data-end=\"25906\">Corresponding test results<\/li>\n<\/ul>\n<p data-start=\"25908\" data-end=\"26023\">The Product Manual provides a sample test-certificate format in Annexure-I.<\/p>\n<hr data-start=\"26025\" data-end=\"26028\" \/>\n<h1 data-section-id=\"1ptlzng\" data-start=\"26030\" data-end=\"26062\">Non-Conforming Product Control<\/h1>\n<p data-start=\"26064\" data-end=\"26161\">Manufacturers must maintain an effective system for handling rejected or non-conforming material.<\/p>\n<p data-start=\"26163\" data-end=\"26364\">The Product Manual requires rejected material that could otherwise be resold to be <strong data-start=\"26246\" data-end=\"26274\">sheared, cut or deformed<\/strong> in a manner that prevents its use for another purpose except remelting, where applicable.<\/p>\n<p data-start=\"26366\" data-end=\"26449\">Separate records must be maintained for rejected or defective materials, including:<\/p>\n<ul data-start=\"26451\" data-end=\"26529\">\n<li data-section-id=\"bo6loz\" data-start=\"26451\" data-end=\"26461\">Quantity<\/li>\n<li data-section-id=\"1tu1gr2\" data-start=\"26462\" data-end=\"26475\">Cast number<\/li>\n<li data-section-id=\"19585s2\" data-start=\"26476\" data-end=\"26489\">Coil number<\/li>\n<li data-section-id=\"18a55zb\" data-start=\"26490\" data-end=\"26511\">Control-unit number<\/li>\n<li data-section-id=\"z3qiqw\" data-start=\"26512\" data-end=\"26529\">Disposal method<\/li>\n<\/ul>\n<p data-start=\"26531\" data-end=\"26710\">Rejected material must not be stored together with conforming material, and any Standard Mark applied to rejected material must be defaced.<\/p>\n<hr data-start=\"26712\" data-end=\"26715\" \/>\n<h1 data-section-id=\"dyrkkd\" data-start=\"26717\" data-end=\"26754\">Testing Equipment for IS 11587:1986<\/h1>\n<p data-start=\"26756\" data-end=\"26826\">The Product Manual&#8217;s equipment list includes major facilities such as:<\/p>\n<h3 data-section-id=\"zvunlc\" data-start=\"26828\" data-end=\"26849\">Chemical Analysis<\/h3>\n<ul data-start=\"26851\" data-end=\"27061\">\n<li data-section-id=\"1s3lq27\" data-start=\"26851\" data-end=\"26865\">Spectrometer<\/li>\n<li data-section-id=\"vw1we6\" data-start=\"26866\" data-end=\"26895\">Atomic absorption equipment<\/li>\n<li data-section-id=\"nbkd4o\" data-start=\"26896\" data-end=\"26911\">ICP equipment<\/li>\n<li data-section-id=\"1hzxth9\" data-start=\"26912\" data-end=\"26951\">Carbon and sulphur analysis equipment<\/li>\n<li data-section-id=\"5z2lkz\" data-start=\"26952\" data-end=\"26971\">Spectrophotometer<\/li>\n<li data-section-id=\"115pkmp\" data-start=\"26972\" data-end=\"26988\">Muffle furnace<\/li>\n<li data-section-id=\"155u48u\" data-start=\"26989\" data-end=\"27003\">Hot-air oven<\/li>\n<li data-section-id=\"12h150s\" data-start=\"27004\" data-end=\"27024\">Electronic balance<\/li>\n<li data-section-id=\"6bkvoc\" data-start=\"27025\" data-end=\"27061\">Laboratory glassware and chemicals<\/li>\n<\/ul>\n<h3 data-section-id=\"1ltmpbw\" data-start=\"27063\" data-end=\"27079\">Tensile Test<\/h3>\n<ul data-start=\"27081\" data-end=\"27134\">\n<li data-section-id=\"vq6ism\" data-start=\"27081\" data-end=\"27134\">Universal Testing Machine \/ Tensile Testing Machine<\/li>\n<\/ul>\n<h3 data-section-id=\"1iwktdp\" data-start=\"27136\" data-end=\"27149\">Bend Test<\/h3>\n<ul data-start=\"27151\" data-end=\"27243\">\n<li data-section-id=\"1j5q4kt\" data-start=\"27151\" data-end=\"27167\">Steel mandrels<\/li>\n<li data-section-id=\"1rveae5\" data-start=\"27168\" data-end=\"27189\">Bend-test templates<\/li>\n<li data-section-id=\"150kpri\" data-start=\"27190\" data-end=\"27207\">UTM attachments<\/li>\n<li data-section-id=\"1ne831o\" data-start=\"27208\" data-end=\"27224\">Clamps or vice<\/li>\n<li data-section-id=\"18rhdo1\" data-start=\"27225\" data-end=\"27243\">Magnifying glass<\/li>\n<\/ul>\n<h3 data-section-id=\"c64phu\" data-start=\"27245\" data-end=\"27260\">Impact Test<\/h3>\n<ul data-start=\"27262\" data-end=\"27345\">\n<li data-section-id=\"1nlvau2\" data-start=\"27262\" data-end=\"27284\">Charpy impact tester<\/li>\n<li data-section-id=\"q5a9fu\" data-start=\"27285\" data-end=\"27298\">Thermometer<\/li>\n<li data-section-id=\"kvs7ti\" data-start=\"27299\" data-end=\"27330\">Specimen inspection equipment<\/li>\n<li data-section-id=\"1lnjkth\" data-start=\"27331\" data-end=\"27345\">Deep freezer<\/li>\n<\/ul>\n<h3 data-section-id=\"15b0n1s\" data-start=\"27347\" data-end=\"27366\">Flattening Test<\/h3>\n<ul data-start=\"27368\" data-end=\"27400\">\n<li data-section-id=\"zp6lbz\" data-start=\"27368\" data-end=\"27400\">UTM with flattening attachment<\/li>\n<\/ul>\n<h3 data-section-id=\"1p6shkr\" data-start=\"27402\" data-end=\"27439\">Defect and Dimensional Inspection<\/h3>\n<ul data-start=\"27441\" data-end=\"27620\">\n<li data-section-id=\"1x6r6op\" data-start=\"27441\" data-end=\"27458\">Vernier caliper<\/li>\n<li data-section-id=\"2pnjll\" data-start=\"27459\" data-end=\"27471\">Micrometer<\/li>\n<li data-section-id=\"oxqnnf\" data-start=\"27472\" data-end=\"27485\">Steel scale<\/li>\n<li data-section-id=\"1mabdrq\" data-start=\"27486\" data-end=\"27498\">Try square<\/li>\n<li data-section-id=\"bvr08i\" data-start=\"27499\" data-end=\"27514\">Radius gauges<\/li>\n<li data-section-id=\"btej02\" data-start=\"27515\" data-end=\"27530\">Filler gauges<\/li>\n<li data-section-id=\"1ta9z3b\" data-start=\"27531\" data-end=\"27545\">Depth gauges<\/li>\n<li data-section-id=\"1crhxfi\" data-start=\"27546\" data-end=\"27562\">Straight edges<\/li>\n<li data-section-id=\"cwxxus\" data-start=\"27563\" data-end=\"27581\">Magnetic V-block<\/li>\n<li data-section-id=\"94lmjs\" data-start=\"27582\" data-end=\"27594\">Protractor<\/li>\n<li data-section-id=\"1xvwe0t\" data-start=\"27595\" data-end=\"27620\">Inside\/outside calipers<\/li>\n<\/ul>\n<h3 data-section-id=\"ynjyay\" data-start=\"27622\" data-end=\"27630\">Mass<\/h3>\n<ul data-start=\"27632\" data-end=\"27650\">\n<li data-section-id=\"yrnxbt\" data-start=\"27632\" data-end=\"27650\">Weighing machine<\/li>\n<\/ul>\n<p data-start=\"27652\" data-end=\"27691\">\n<p data-start=\"27693\" data-end=\"27825\">The Product Manual states that the equipment list is <strong data-start=\"27746\" data-end=\"27784\">indicative only and not exhaustive<\/strong>.<\/p>\n<hr data-start=\"27827\" data-end=\"27830\" \/>\n<h1 data-section-id=\"p3hk5k\" data-start=\"27832\" data-end=\"27874\">Documents Required for BIS Certification<\/h1>\n<p data-start=\"27876\" data-end=\"27906\">Typical documents may include:<\/p>\n<ul data-start=\"27908\" data-end=\"28539\">\n<li data-section-id=\"laj0jm\" data-start=\"27908\" data-end=\"27940\">Company registration documents<\/li>\n<li data-section-id=\"a8o83y\" data-start=\"27941\" data-end=\"27964\">Factory address proof<\/li>\n<li data-section-id=\"17ibqzq\" data-start=\"27965\" data-end=\"27981\">Factory layout<\/li>\n<li data-section-id=\"2qrcjh\" data-start=\"27982\" data-end=\"28016\">Manufacturing process flow chart<\/li>\n<li data-section-id=\"ef1hg\" data-start=\"28017\" data-end=\"28033\">Machinery list<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"28034\" data-end=\"28058\">Product specifications<\/li>\n<li data-section-id=\"7wt11b\" data-start=\"28059\" data-end=\"28074\">Grade details<\/li>\n<li data-section-id=\"y8opy2\" data-start=\"28075\" data-end=\"28097\">Product-form details<\/li>\n<li data-section-id=\"1w40xrm\" data-start=\"28098\" data-end=\"28110\">Size range<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"28111\" data-end=\"28129\">Product drawings<\/li>\n<li data-section-id=\"cjqh7s\" data-start=\"28130\" data-end=\"28152\">Raw-material details<\/li>\n<li data-section-id=\"1cr6qo4\" data-start=\"28153\" data-end=\"28172\">Heat\/cast records<\/li>\n<li data-section-id=\"1xxybf7\" data-start=\"28173\" data-end=\"28201\">Material test certificates<\/li>\n<li data-section-id=\"1qi33mm\" data-start=\"28202\" data-end=\"28220\">Supplier details<\/li>\n<li data-section-id=\"rziqi5\" data-start=\"28221\" data-end=\"28248\">Chemical-analysis records<\/li>\n<li data-section-id=\"1fo8gvq\" data-start=\"28249\" data-end=\"28273\">Testing equipment list<\/li>\n<li data-section-id=\"1ymt51g\" data-start=\"28274\" data-end=\"28300\">Calibration certificates<\/li>\n<li data-section-id=\"5vctzt\" data-start=\"28301\" data-end=\"28325\">Quality Assurance Plan<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"28326\" data-end=\"28346\">Inspection records<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"28347\" data-end=\"28367\">Production records<\/li>\n<li data-section-id=\"xl4mzn\" data-start=\"28368\" data-end=\"28382\">Test reports<\/li>\n<li data-section-id=\"684x8w\" data-start=\"28383\" data-end=\"28404\">Product photographs<\/li>\n<li data-section-id=\"1uio16b\" data-start=\"28405\" data-end=\"28422\">Packing details<\/li>\n<li data-section-id=\"1hcgcf\" data-start=\"28423\" data-end=\"28440\">Marking details<\/li>\n<li data-section-id=\"c8twi0\" data-start=\"28441\" data-end=\"28466\">Test certificate format<\/li>\n<li data-section-id=\"lp672w\" data-start=\"28467\" data-end=\"28499\">Authorised signatory documents<\/li>\n<li data-section-id=\"8zjtnv\" data-start=\"28500\" data-end=\"28539\">Trademark documents, where applicable<\/li>\n<\/ul>\n<p data-start=\"28541\" data-end=\"28640\">The final documentation requirements depend on the manufacturer, product scope and BIS application.<\/p>\n<hr data-start=\"28642\" data-end=\"28645\" \/>\n<h1 data-section-id=\"7n2au7\" data-start=\"28647\" data-end=\"28669\">Marking Requirements<\/h1>\n<p data-start=\"28671\" data-end=\"28919\">The BIS Product Manual specifies that the <strong data-start=\"28713\" data-end=\"28730\">Standard Mark<\/strong> must be incorporated on the product and\/or the Test Certificate accompanying each consignment, provided that the material conforms to IS 11587:1986.<\/p>\n<p data-start=\"28921\" data-end=\"29024\">The manufacturer must also follow the applicable requirements of IS 11587:1986 for marking and packing.<\/p>\n<p data-start=\"29026\" data-end=\"29101\">Product identification should support traceability through details such as:<\/p>\n<ul data-start=\"29103\" data-end=\"29159\">\n<li data-section-id=\"170hry5\" data-start=\"29103\" data-end=\"29110\">Grade<\/li>\n<li data-section-id=\"1j4dcvh\" data-start=\"29111\" data-end=\"29117\">Size<\/li>\n<li data-section-id=\"zy1zez\" data-start=\"29118\" data-end=\"29130\">Dimensions<\/li>\n<li data-section-id=\"1tu1gr2\" data-start=\"29131\" data-end=\"29144\">Cast number<\/li>\n<li data-section-id=\"1sta8lx\" data-start=\"29145\" data-end=\"29159\">Product form<\/li>\n<\/ul>\n<hr data-start=\"29161\" data-end=\"29164\" \/>\n<h1 data-section-id=\"1ufxuqp\" data-start=\"29166\" data-end=\"29211\">Common Reasons for BIS Certification Delays<\/h1>\n<p data-start=\"29213\" data-end=\"29254\">Manufacturers may face delays because of:<\/p>\n<ul data-start=\"29256\" data-end=\"29821\">\n<li data-section-id=\"n6hoec\" data-start=\"29256\" data-end=\"29283\">Incorrect grade selection<\/li>\n<li data-section-id=\"54ieek\" data-start=\"29284\" data-end=\"29308\">Incorrect product form<\/li>\n<li data-section-id=\"3aqf2\" data-start=\"29309\" data-end=\"29331\">Incorrect size scope<\/li>\n<li data-section-id=\"1j78l9q\" data-start=\"29332\" data-end=\"29352\">Incorrect grouping<\/li>\n<li data-section-id=\"11jbz09\" data-start=\"29353\" data-end=\"29383\">Chemical-composition failure<\/li>\n<li data-section-id=\"p5gmyo\" data-start=\"29384\" data-end=\"29420\">Weldability-related non-conformity<\/li>\n<li data-section-id=\"1o9ds5o\" data-start=\"29421\" data-end=\"29447\">Tensile-strength failure<\/li>\n<li data-section-id=\"ktphyy\" data-start=\"29448\" data-end=\"29468\">Elongation failure<\/li>\n<li data-section-id=\"1f7cs4e\" data-start=\"29469\" data-end=\"29488\">Bend-test failure<\/li>\n<li data-section-id=\"j1skj5\" data-start=\"29489\" data-end=\"29510\">Impact-test failure<\/li>\n<li data-section-id=\"9ggmab\" data-start=\"29511\" data-end=\"29536\">Flattening-test failure<\/li>\n<li data-section-id=\"1tyl2ef\" data-start=\"29537\" data-end=\"29565\">Dimensional non-conformity<\/li>\n<li data-section-id=\"1pcnrsr\" data-start=\"29566\" data-end=\"29583\">Surface defects<\/li>\n<li data-section-id=\"82ougr\" data-start=\"29584\" data-end=\"29618\">Inadequate laboratory facilities<\/li>\n<li data-section-id=\"jaist4\" data-start=\"29619\" data-end=\"29648\">Missing calibration records<\/li>\n<li data-section-id=\"1wbchiz\" data-start=\"29649\" data-end=\"29678\">Poor heat\/cast traceability<\/li>\n<li data-section-id=\"1ritz6f\" data-start=\"29679\" data-end=\"29707\">Incorrect sample selection<\/li>\n<li data-section-id=\"7qbfzi\" data-start=\"29708\" data-end=\"29733\">Incomplete test records<\/li>\n<li data-section-id=\"1pruwyv\" data-start=\"29734\" data-end=\"29768\">Factory not ready for inspection<\/li>\n<li data-section-id=\"zzsnng\" data-start=\"29769\" data-end=\"29792\">Incorrect BIS marking<\/li>\n<li data-section-id=\"5htl6x\" data-start=\"29793\" data-end=\"29821\">Documentation deficiencies<\/li>\n<\/ul>\n<p data-start=\"29823\" data-end=\"29920\">A technical review before the BIS application can help manufacturers identify these issues early.<\/p>\n<hr data-start=\"29922\" data-end=\"29925\" \/>\n<h1 data-section-id=\"14gq2jt\" data-start=\"29927\" data-end=\"29990\">BIS Certification Cost for Structural Weather Resistant Steel<\/h1>\n<p data-start=\"29992\" data-end=\"30073\">There is no single fixed BIS certification cost applicable to every manufacturer.<\/p>\n<p data-start=\"30075\" data-end=\"30104\">The total cost may depend on:<\/p>\n<ul data-start=\"30106\" data-end=\"30369\">\n<li data-section-id=\"qbv4f3\" data-start=\"30106\" data-end=\"30128\">BIS application fees<\/li>\n<li data-section-id=\"khts3h\" data-start=\"30129\" data-end=\"30149\">Laboratory testing<\/li>\n<li data-section-id=\"vmfc4k\" data-start=\"30150\" data-end=\"30168\">Number of grades<\/li>\n<li data-section-id=\"7x08ue\" data-start=\"30169\" data-end=\"30184\">Product forms<\/li>\n<li data-section-id=\"1w40xrm\" data-start=\"30185\" data-end=\"30197\">Size range<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"30198\" data-end=\"30216\">Product grouping<\/li>\n<li data-section-id=\"189nvic\" data-start=\"30217\" data-end=\"30251\">Number of representative samples<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"30252\" data-end=\"30272\">Factory assessment<\/li>\n<li data-section-id=\"hrwpmc\" data-start=\"30273\" data-end=\"30292\">Testing equipment<\/li>\n<li data-section-id=\"zkwwle\" data-start=\"30293\" data-end=\"30306\">Calibration<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"30307\" data-end=\"30322\">Documentation<\/li>\n<li data-section-id=\"w80kxv\" data-start=\"30323\" data-end=\"30347\">Retesting, if required<\/li>\n<li data-section-id=\"1q8f3t4\" data-start=\"30348\" data-end=\"30369\">Consultancy charges<\/li>\n<\/ul>\n<p data-start=\"30371\" data-end=\"30440\">Current BIS LIMS information shows testing charges for IS 11587:1986.<\/p>\n<p data-start=\"30442\" data-end=\"30481\">One current BIS laboratory entry lists:<\/p>\n<p data-start=\"30483\" data-end=\"30513\"><strong data-start=\"30483\" data-end=\"30513\">Mechanical testing: \u20b95,600<\/strong><\/p>\n<p data-start=\"30515\" data-end=\"30557\"><strong data-start=\"30515\" data-end=\"30557\">Chemical parameters in Table 1: \u20b98,600<\/strong><\/p>\n<p data-start=\"30559\" data-end=\"30615\">excluding taxes.<\/p>\n<p data-start=\"30617\" data-end=\"30702\">These are laboratory-testing charges and <strong data-start=\"30658\" data-end=\"30701\">not the complete BIS certification cost<\/strong>.<\/p>\n<p data-start=\"30704\" data-end=\"30856\">The final project cost should be calculated after reviewing the manufacturer&#8217;s grade, product form, size range, laboratory scope and factory facilities.<\/p>\n<hr data-start=\"30858\" data-end=\"30861\" \/>\n<h1 data-section-id=\"1b1ee4d\" data-start=\"30863\" data-end=\"30891\">BIS Certification Timeline<\/h1>\n<p data-start=\"30893\" data-end=\"30942\">The certification timeline may vary depending on:<\/p>\n<ul data-start=\"30944\" data-end=\"31183\">\n<li data-section-id=\"vmfc4k\" data-start=\"30944\" data-end=\"30962\">Number of grades<\/li>\n<li data-section-id=\"7x08ue\" data-start=\"30963\" data-end=\"30978\">Product forms<\/li>\n<li data-section-id=\"1w40xrm\" data-start=\"30979\" data-end=\"30991\">Size range<\/li>\n<li data-section-id=\"6jtuf\" data-start=\"30992\" data-end=\"31002\">Grouping<\/li>\n<li data-section-id=\"l4o622\" data-start=\"31003\" data-end=\"31028\">Documentation readiness<\/li>\n<li data-section-id=\"1l0m60n\" data-start=\"31029\" data-end=\"31049\">Sample preparation<\/li>\n<li data-section-id=\"1n720d6\" data-start=\"31050\" data-end=\"31075\">Laboratory availability<\/li>\n<li data-section-id=\"2xn0ck\" data-start=\"31076\" data-end=\"31093\">Testing results<\/li>\n<li data-section-id=\"czyv2v\" data-start=\"31094\" data-end=\"31120\">BIS application scrutiny<\/li>\n<li data-section-id=\"1213b4c\" data-start=\"31121\" data-end=\"31140\">Factory readiness<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"31141\" data-end=\"31161\">Factory assessment<\/li>\n<li data-section-id=\"2xyyqj\" data-start=\"31162\" data-end=\"31183\">Observation closure<\/li>\n<\/ul>\n<p data-start=\"31185\" data-end=\"31347\">Manufacturers can reduce unnecessary delays by finalising their scope, testing strategy, documents and factory arrangements before submitting the BIS application.<\/p>\n<hr data-start=\"31349\" data-end=\"31352\" \/>\n<h1 data-section-id=\"1ujrgz6\" data-start=\"31354\" data-end=\"31413\">Benefits of BIS Certification for Weather Resistant Steel<\/h1>\n<h3 data-section-id=\"15cgiwz\" data-start=\"31415\" data-end=\"31440\">Regulatory Compliance<\/h3>\n<p data-start=\"31442\" data-end=\"31509\">Helps manufacturers meet applicable BIS and Steel QCO requirements.<\/p>\n<h3 data-section-id=\"tf1c9s\" data-start=\"31511\" data-end=\"31523\">ISI Mark<\/h3>\n<p data-start=\"31525\" data-end=\"31628\">Allows eligible manufacturers to use the BIS Standard Mark on products covered by the approved licence.<\/p>\n<h3 data-section-id=\"y04dn1\" data-start=\"31630\" data-end=\"31661\">Better Corrosion Resistance<\/h3>\n<p data-start=\"31663\" data-end=\"31761\">Weather-resistant steel is specifically designed for improved resistance to atmospheric corrosion.<\/p>\n<h3 data-section-id=\"1oa4frm\" data-start=\"31763\" data-end=\"31790\">Structural Applications<\/h3>\n<p data-start=\"31792\" data-end=\"31889\">Conforming products are suitable for structural applications falling within the standard&#8217;s scope.<\/p>\n<h3 data-section-id=\"a6o7rg\" data-start=\"31891\" data-end=\"31927\">Consistent Mechanical Properties<\/h3>\n<p data-start=\"31929\" data-end=\"32005\">Chemical and mechanical testing helps establish consistent material quality.<\/p>\n<h3 data-section-id=\"k08kti\" data-start=\"32007\" data-end=\"32030\">Customer Confidence<\/h3>\n<p data-start=\"32032\" data-end=\"32145\">BIS certification can improve confidence among structural steel buyers, contractors and infrastructure companies.<\/p>\n<h3 data-section-id=\"s62ca3\" data-start=\"32147\" data-end=\"32168\">Market Acceptance<\/h3>\n<p data-start=\"32170\" data-end=\"32250\">Certification supports legal market access where BIS certification is mandatory.<\/p>\n<h3 data-section-id=\"jvxxdo\" data-start=\"32252\" data-end=\"32278\">Better Quality Control<\/h3>\n<p data-start=\"32280\" data-end=\"32373\">The BIS inspection scheme encourages systematic chemical, mechanical and dimensional control.<\/p>\n<hr data-start=\"32375\" data-end=\"32378\" \/>\n<h1 data-section-id=\"18jhjpw\" data-start=\"32380\" data-end=\"32410\">Why Choose Qualitance India?<\/h1>\n<p data-start=\"32412\" data-end=\"32542\"><strong data-start=\"32412\" data-end=\"32432\">Qualitance India<\/strong> provides professional BIS Certification Consultancy for manufacturers seeking BIS and ISI Mark certification.<\/p>\n<p data-start=\"32544\" data-end=\"32645\">For <strong data-start=\"32548\" data-end=\"32607\">Structural Weather Resistant Steel as per IS 11587:1986<\/strong>, our consultancy support can include:<\/p>\n<ul data-start=\"32647\" data-end=\"33117\">\n<li data-section-id=\"1mfdgr4\" data-start=\"32647\" data-end=\"32681\">Product applicability assessment<\/li>\n<li data-section-id=\"1krcfn5\" data-start=\"32682\" data-end=\"32716\">IS 11587:1986 requirement review<\/li>\n<li data-section-id=\"ga9h2j\" data-start=\"32717\" data-end=\"32735\">Grade assessment<\/li>\n<li data-section-id=\"npjs6m\" data-start=\"32736\" data-end=\"32761\">Product-form assessment<\/li>\n<li data-section-id=\"17erzcv\" data-start=\"32762\" data-end=\"32789\">Size and shape assessment<\/li>\n<li data-section-id=\"ykvcbu\" data-start=\"32790\" data-end=\"32817\">Product grouping guidance<\/li>\n<li data-section-id=\"13ne8bc\" data-start=\"32818\" data-end=\"32845\">Sample selection guidance<\/li>\n<li data-section-id=\"1olazsl\" data-start=\"32846\" data-end=\"32877\">Chemical testing coordination<\/li>\n<li data-section-id=\"15ztbp6\" data-start=\"32878\" data-end=\"32911\">Mechanical testing coordination<\/li>\n<li data-section-id=\"zrfurn\" data-start=\"32912\" data-end=\"32939\">Documentation preparation<\/li>\n<li data-section-id=\"maajyk\" data-start=\"32940\" data-end=\"32968\">BIS application assistance<\/li>\n<li data-section-id=\"sy9ixn\" data-start=\"32969\" data-end=\"33001\">Factory inspection preparation<\/li>\n<li data-section-id=\"14qpm0y\" data-start=\"33002\" data-end=\"33030\">Testing equipment guidance<\/li>\n<li data-section-id=\"1bxrev1\" data-start=\"33031\" data-end=\"33062\">Quality-control documentation<\/li>\n<li data-section-id=\"3i8g1g\" data-start=\"33063\" data-end=\"33092\">Observation closure support<\/li>\n<li data-section-id=\"kobqql\" data-start=\"33093\" data-end=\"33117\">BIS licence assistance<\/li>\n<\/ul>\n<p data-start=\"33119\" data-end=\"33307\">Our support is designed to help manufacturers manage the certification process from product assessment through laboratory testing, BIS application, factory assessment and licence approval.<\/p>\n<h3 data-section-id=\"16z2skw\" data-start=\"33309\" data-end=\"33337\">Contact Qualitance India<\/h3>\n<p data-start=\"33339\" data-end=\"33438\"><strong data-start=\"33339\" data-end=\"33349\">Phone:<\/strong> +91 93106 15170<br data-start=\"33365\" data-end=\"33368\" \/><strong data-start=\"33368\" data-end=\"33378\">Email:<\/strong> <a class=\"decorated-link\" href=\"mailto:info@qualitanceindia.com\" rel=\"noopener\" data-start=\"33379\" data-end=\"33403\">info@qualitanceindia.com<\/a><br data-start=\"33403\" data-end=\"33406\" \/><strong data-start=\"33406\" data-end=\"33418\">Website:<\/strong> qualitanceindia.com<\/p>\n<hr data-start=\"33440\" data-end=\"33443\" \/>\n<h1 data-section-id=\"cco78p\" data-start=\"33445\" data-end=\"33485\">BIS Certification Process \u2013 Quick Flow<\/h1>\n<p data-start=\"33487\" data-end=\"34131\"><strong data-start=\"33487\" data-end=\"33513\">Product Identification<\/strong><br data-start=\"33513\" data-end=\"33516\" \/>\u2193<br data-start=\"33517\" data-end=\"33520\" \/><strong data-start=\"33520\" data-end=\"33556\">IS 11587:1986 Requirement Review<\/strong><br data-start=\"33556\" data-end=\"33559\" \/>\u2193<br data-start=\"33560\" data-end=\"33563\" \/><strong data-start=\"33563\" data-end=\"33582\">Grade Selection<\/strong><br data-start=\"33582\" data-end=\"33585\" \/>\u2193<br data-start=\"33586\" data-end=\"33589\" \/><strong data-start=\"33589\" data-end=\"33641\">Plate \/ Sheet \/ Strip \/ Section \/ Bar Assessment<\/strong><br data-start=\"33641\" data-end=\"33644\" \/>\u2193<br data-start=\"33645\" data-end=\"33648\" \/><strong data-start=\"33648\" data-end=\"33675\">Size &amp; Shape Assessment<\/strong><br data-start=\"33675\" data-end=\"33678\" \/>\u2193<br data-start=\"33679\" data-end=\"33682\" \/><strong data-start=\"33682\" data-end=\"33702\">Product Grouping<\/strong><br data-start=\"33702\" data-end=\"33705\" \/>\u2193<br data-start=\"33706\" data-end=\"33709\" \/><strong data-start=\"33709\" data-end=\"33738\">Documentation Preparation<\/strong><br data-start=\"33738\" data-end=\"33741\" \/>\u2193<br data-start=\"33742\" data-end=\"33745\" \/><strong data-start=\"33745\" data-end=\"33782\">Representative Sample Preparation<\/strong><br data-start=\"33782\" data-end=\"33785\" \/>\u2193<br data-start=\"33786\" data-end=\"33789\" \/><strong data-start=\"33789\" data-end=\"33821\">Chemical Composition Testing<\/strong><br data-start=\"33821\" data-end=\"33824\" \/>\u2193<br data-start=\"33825\" data-end=\"33828\" \/><strong data-start=\"33828\" data-end=\"33847\">Tensile Testing<\/strong><br data-start=\"33847\" data-end=\"33850\" \/>\u2193<br data-start=\"33851\" data-end=\"33854\" \/><strong data-start=\"33854\" data-end=\"33890\">Bend \/ Impact \/ Applicable Tests<\/strong><br data-start=\"33890\" data-end=\"33893\" \/>\u2193<br data-start=\"33894\" data-end=\"33897\" \/><strong data-start=\"33897\" data-end=\"33932\">Dimensional &amp; Defect Inspection<\/strong><br data-start=\"33932\" data-end=\"33935\" \/>\u2193<br data-start=\"33936\" data-end=\"33939\" \/><strong data-start=\"33939\" data-end=\"33958\">BIS Application<\/strong><br data-start=\"33958\" data-end=\"33961\" \/>\u2193<br data-start=\"33962\" data-end=\"33965\" \/><strong data-start=\"33965\" data-end=\"33989\">Application Scrutiny<\/strong><br data-start=\"33989\" data-end=\"33992\" \/>\u2193<br data-start=\"33993\" data-end=\"33996\" \/><strong data-start=\"33996\" data-end=\"34018\">Factory Assessment<\/strong><br data-start=\"34018\" data-end=\"34021\" \/>\u2193<br data-start=\"34022\" data-end=\"34025\" \/><strong data-start=\"34025\" data-end=\"34048\">Observation Closure<\/strong><br data-start=\"34048\" data-end=\"34051\" \/>\u2193<br data-start=\"34052\" data-end=\"34055\" \/><strong data-start=\"34055\" data-end=\"34076\">BIS Licence Grant<\/strong><br data-start=\"34076\" data-end=\"34079\" \/>\u2193<br data-start=\"34080\" data-end=\"34083\" \/><strong data-start=\"34083\" data-end=\"34131\">ISI Mark on Approved Weather Resistant Steel<\/strong><\/p>\n<hr data-start=\"34133\" data-end=\"34136\" \/>\n<h1 data-section-id=\"hkd5a4\" data-start=\"34138\" data-end=\"34166\">Frequently Asked Questions<\/h1>\n<h2 data-section-id=\"gkc5xl\" data-start=\"34168\" data-end=\"34196\">1. What is IS 11587:1986?<\/h2>\n<p data-start=\"34198\" data-end=\"34299\">IS 11587:1986 is the Indian Standard titled <strong data-start=\"34242\" data-end=\"34298\">Specification for Structural Weather Resistant Steel<\/strong>.<\/p>\n<h2 data-section-id=\"rcu4yx\" data-start=\"34301\" data-end=\"34350\">2. What is structural weather resistant steel?<\/h2>\n<p data-start=\"34352\" data-end=\"34567\">It is high-strength low-alloy structural steel designed for improved resistance to atmospheric corrosion and intended for structural construction requiring weather resistance.<\/p>\n<h2 data-section-id=\"12w3w4a\" data-start=\"34569\" data-end=\"34625\">3. Is BIS certification mandatory for IS 11587 steel?<\/h2>\n<p data-start=\"34627\" data-end=\"34818\">Yes. IS 11587:1986 is specifically listed in the <strong data-start=\"34676\" data-end=\"34734\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, with implementation with immediate effect.<\/p>\n<h2 data-section-id=\"yaxhee\" data-start=\"34820\" data-end=\"34850\">4. What grades are covered?<\/h2>\n<p data-start=\"34852\" data-end=\"34991\">The BIS Product Manual identifies <strong data-start=\"34886\" data-end=\"34950\">WR-Fe 480A, WR-Fe 480B, WR-Fe 490H, WR-Fe 490C and WR-Fe 500<\/strong>.<\/p>\n<h2 data-section-id=\"mkvi67\" data-start=\"34993\" data-end=\"35030\">5. What product forms are covered?<\/h2>\n<p data-start=\"35032\" data-end=\"35169\">The Product Manual identifies <strong data-start=\"35062\" data-end=\"35128\">plate, sheet, strip, sections, bars and other applicable forms<\/strong>.<\/p>\n<h2 data-section-id=\"19x8so0\" data-start=\"35171\" data-end=\"35221\">6. What is the BIS mechanical-test sample size?<\/h2>\n<p data-start=\"35223\" data-end=\"35327\">The Product Manual specifies <strong data-start=\"35252\" data-end=\"35263\">1 metre<\/strong> for mechanical testing.<\/p>\n<h2 data-section-id=\"3pj8t2\" data-start=\"35329\" data-end=\"35373\">7. What is the chemical-test sample size?<\/h2>\n<p data-start=\"35375\" data-end=\"35516\">The Product Manual specifies <strong data-start=\"35404\" data-end=\"35454\">five pieces of 50 mm \u00d7 50 mm or 100 g drilling<\/strong> for chemical testing.<\/p>\n<h2 data-section-id=\"13u8krn\" data-start=\"35518\" data-end=\"35587\">8. What are the main tests for Structural Weather Resistant Steel?<\/h2>\n<p data-start=\"35589\" data-end=\"35817\">Important tests include chemical composition, weldability, tensile test, bend test, impact test, flattening test where applicable, freedom from defects, dimensions and tolerances and mass.<\/p>\n<h2 data-section-id=\"1tn3e9l\" data-start=\"35819\" data-end=\"35868\">9. Is impact testing required for every grade?<\/h2>\n<p data-start=\"35870\" data-end=\"36149\">The applicable requirement depends on the grade and agreement between purchaser and manufacturer. For WR-Fe 480A and WR-Fe 480B, the Product Manual states that impact testing is performed when agreed between the purchaser and manufacturer.<\/p>\n<h2 data-section-id=\"192refh\" data-start=\"36151\" data-end=\"36199\">10. Is bend testing mandatory for WR-Fe 490C?<\/h2>\n<p data-start=\"36201\" data-end=\"36370\">The Product Manual states that bend testing for <strong data-start=\"36249\" data-end=\"36275\">WR-Fe 490C is optional<\/strong> and is performed only when specified by the purchaser.<\/p>\n<h2 data-section-id=\"ihshrq\" data-start=\"36372\" data-end=\"36423\">11. What is special about WR-Fe 490H below 3 mm?<\/h2>\n<p data-start=\"36425\" data-end=\"36654\">For WR-Fe 490H steel sheet and strip below 3 mm thickness, the Product Manual states that tensile strength of <strong data-start=\"36535\" data-end=\"36557\">510 N\/mm\u00b2 or above<\/strong> applies by agreement between purchaser and manufacturer.<\/p>\n<h2 data-section-id=\"1r3kt7o\" data-start=\"36656\" data-end=\"36701\">12. What is the control unit for IS 11587?<\/h2>\n<p data-start=\"36703\" data-end=\"36913\">The control unit is the entire quantity of Structural Weather Resistant Steel of the same grade and form made from the same cast\/heat under identical conditions in a day.<\/p>\n<h2 data-section-id=\"u9bd29\" data-start=\"36915\" data-end=\"36952\">13. Is product grouping available?<\/h2>\n<p data-start=\"36954\" data-end=\"37101\">Yes. The Product Manual provides grouping guidelines for flat products, sections, hollow sections and bars.<\/p>\n<h2 data-section-id=\"8wf70o\" data-start=\"37103\" data-end=\"37141\">14. Is factory inspection required?<\/h2>\n<p data-start=\"37143\" data-end=\"37220\">Yes. Factory assessment forms part of the BIS Scheme-I certification process.<\/p>\n<h2 data-section-id=\"180jvh1\" data-start=\"37222\" data-end=\"37264\">15. What testing equipment is required?<\/h2>\n<p data-start=\"37266\" data-end=\"37472\">The Product Manual identifies equipment such as UTM, bend-test mandrels, Charpy impact tester, chemical-analysis equipment, dimensional gauges and weighing equipment.<\/p>\n<h2 data-section-id=\"1g8eoo2\" data-start=\"37474\" data-end=\"37512\">16. Is a test certificate required?<\/h2>\n<p data-start=\"37514\" data-end=\"37770\">Yes. The Product Manual requires a test certificate for each consignment of BIS-certified Structural Weather Resistant Steel containing the Standard Mark, cast number, size, dimensions and corresponding test results.<\/p>\n<h2 data-section-id=\"16r5ir0\" data-start=\"37772\" data-end=\"37823\">17. What are the current BIS laboratory charges?<\/h2>\n<p data-start=\"37825\" data-end=\"37992\">One current BIS laboratory listing shows <strong data-start=\"37866\" data-end=\"37934\">\u20b95,600 for mechanical testing and \u20b98,600 for chemical parameters<\/strong>, excluding taxes.<\/p>\n<h2 data-section-id=\"1o08txd\" data-start=\"37994\" data-end=\"38047\">18. How much does complete BIS certification cost?<\/h2>\n<p data-start=\"38049\" data-end=\"38207\">The complete cost depends on the product scope, grades, product forms, testing, BIS application, factory assessment, equipment, documentation and consultancy.<\/p>\n<h2 data-section-id=\"1r8kum8\" data-start=\"38209\" data-end=\"38253\">19. How long does BIS certification take?<\/h2>\n<p data-start=\"38255\" data-end=\"38391\">The timeline depends on the product scope, testing, documentation, application scrutiny, factory assessment and closure of observations.<\/p>\n<h2 data-section-id=\"1fbck2j\" data-start=\"38393\" data-end=\"38459\">20. Can Qualitance India help with IS 11587:1986 certification?<\/h2>\n<p data-start=\"38461\" data-end=\"38645\">Yes. Qualitance India provides product assessment, grade and scope guidance, documentation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<hr data-start=\"38647\" data-end=\"38650\" \/>\n<h1 data-section-id=\"g38lxp\" data-start=\"38652\" data-end=\"38669\">People Also Ask<\/h1>\n<h3 data-section-id=\"7mxk8d\" data-start=\"38671\" data-end=\"38740\">What is BIS certification for Structural Weather Resistant Steel?<\/h3>\n<p data-start=\"38742\" data-end=\"38921\">BIS certification for Structural Weather Resistant Steel is the conformity-assessment process for demonstrating compliance with <strong data-start=\"38870\" data-end=\"38887\">IS 11587:1986<\/strong> under the BIS Scheme-I framework.<\/p>\n<h3 data-section-id=\"2kt63\" data-start=\"38923\" data-end=\"38956\">Is IS 11587:1986 under a QCO?<\/h3>\n<p data-start=\"38958\" data-end=\"39108\">Yes. IS 11587:1986 is specifically included in the <strong data-start=\"39009\" data-end=\"39067\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>.<\/p>\n<h3 data-section-id=\"3cra7e\" data-start=\"39110\" data-end=\"39167\">What is the BIS standard for weather resistant steel?<\/h3>\n<p data-start=\"39169\" data-end=\"39276\">The applicable Indian Standard is <strong data-start=\"39203\" data-end=\"39275\">IS 11587:1986 \u2013 Specification for Structural Weather Resistant Steel<\/strong>.<\/p>\n<h3 data-section-id=\"1dxs4cy\" data-start=\"39278\" data-end=\"39323\">What grades are available under IS 11587?<\/h3>\n<p data-start=\"39325\" data-end=\"39464\">The BIS Product Manual identifies <strong data-start=\"39359\" data-end=\"39423\">WR-Fe 480A, WR-Fe 480B, WR-Fe 490H, WR-Fe 490C and WR-Fe 500<\/strong>.<\/p>\n<h3 data-section-id=\"8ealp5\" data-start=\"39466\" data-end=\"39511\">What products are covered under IS 11587?<\/h3>\n<p data-start=\"39513\" data-end=\"39670\">Plates, sheets, strips, sections, bars and other applicable forms are included in the Product Manual&#8217;s licence scope.<\/p>\n<h3 data-section-id=\"1a1qj8z\" data-start=\"39672\" data-end=\"39728\">What tests are performed on weather resistant steel?<\/h3>\n<p data-start=\"39730\" data-end=\"39897\">Testing includes chemical composition, weldability, tensile properties, bend test, impact test, flattening where applicable, freedom from defects, dimensions and mass.<\/p>\n<h3 data-section-id=\"t7qnyd\" data-start=\"39899\" data-end=\"39950\">What is the purpose of weather resistant steel?<\/h3>\n<p data-start=\"39952\" data-end=\"40090\">It is intended for structural applications requiring improved resistance to atmospheric corrosion.<\/p>\n<h3 data-section-id=\"1d2hcb1\" data-start=\"40092\" data-end=\"40149\">How do I get an ISI Mark for weather resistant steel?<\/h3>\n<p data-start=\"40151\" data-end=\"40315\">A manufacturer must obtain the applicable BIS licence for IS 11587:1986 and comply with BIS requirements for testing, marking, inspection and continuing conformity.<\/p>\n<hr data-start=\"40317\" data-end=\"40320\" \/>\n<h1 data-section-id=\"okqknw\" data-start=\"40322\" data-end=\"40352\">Frequently Searched Keywords<\/h1>\n<ul data-start=\"40354\" data-end=\"40963\">\n<li data-section-id=\"1jz8yvg\" data-start=\"40354\" data-end=\"40412\">BIS Certification for Structural Weather Resistant Steel<\/li>\n<li data-section-id=\"gj4dbl\" data-start=\"40413\" data-end=\"40460\">BIS Certification for Weather Resistant Steel<\/li>\n<li data-section-id=\"83i78s\" data-start=\"40461\" data-end=\"40490\">IS 11587:1986 Certification<\/li>\n<li data-section-id=\"1ada61u\" data-start=\"40491\" data-end=\"40532\">BIS Licence for Weather Resistant Steel<\/li>\n<li data-section-id=\"1sh03oo\" data-start=\"40533\" data-end=\"40561\">IS 11587 BIS Certification<\/li>\n<li data-section-id=\"10al9ok\" data-start=\"40562\" data-end=\"40610\">Structural Weather Resistant Steel BIS Licence<\/li>\n<li data-section-id=\"18ko5b0\" data-start=\"40611\" data-end=\"40644\">Weather Resistant Steel Testing<\/li>\n<li data-section-id=\"1fxb2fr\" data-start=\"40645\" data-end=\"40674\">Weather Resistant Steel QCO<\/li>\n<li data-section-id=\"x9edp6\" data-start=\"40675\" data-end=\"40700\">Steel QCO 2024 IS 11587<\/li>\n<li data-section-id=\"t6hun2\" data-start=\"40701\" data-end=\"40731\">WR-Fe 480A BIS Certification<\/li>\n<li data-section-id=\"g17ti5\" data-start=\"40732\" data-end=\"40762\">WR-Fe 480B BIS Certification<\/li>\n<li data-section-id=\"10hulee\" data-start=\"40763\" data-end=\"40793\">WR-Fe 490H BIS Certification<\/li>\n<li data-section-id=\"13wbgrh\" data-start=\"40794\" data-end=\"40824\">WR-Fe 490C BIS Certification<\/li>\n<li data-section-id=\"1mdt7li\" data-start=\"40825\" data-end=\"40854\">WR-Fe 500 BIS Certification<\/li>\n<li data-section-id=\"18of9wh\" data-start=\"40855\" data-end=\"40886\">BIS Certification Consultancy<\/li>\n<li data-section-id=\"9q4s3e\" data-start=\"40887\" data-end=\"40924\">BIS Consultant for Structural Steel<\/li>\n<li data-section-id=\"3ssgl3\" data-start=\"40925\" data-end=\"40963\">ISI Mark for Weather Resistant Steel<\/li>\n<\/ul>\n<hr data-start=\"40965\" data-end=\"40968\" \/>\n<h1 data-section-id=\"fphl3b\" data-start=\"40970\" data-end=\"41006\">Related BIS Certification Services<\/h1>\n<ul data-start=\"41008\" data-end=\"41562\">\n<li data-section-id=\"146m904\" data-start=\"41008\" data-end=\"41068\">BIS Certification for Fire Resistant Steel \u2013 IS 15103:2002<\/li>\n<li data-section-id=\"n7a7ka\" data-start=\"41069\" data-end=\"41119\">BIS Certification for Structural Steel \u2013 IS 2062<\/li>\n<li data-section-id=\"1kv2ouf\" data-start=\"41120\" data-end=\"41198\">BIS Certification for Steel with Improved Seismic Resistance \u2013 IS 15962:2012<\/li>\n<li data-section-id=\"jccq4\" data-start=\"41199\" data-end=\"41266\">BIS Certification for Galvanized Structural Steel \u2013 IS 16732:2019<\/li>\n<li data-section-id=\"9xvwiv\" data-start=\"41267\" data-end=\"41303\">BIS Certification for Steel Plates<\/li>\n<li data-section-id=\"77ba82\" data-start=\"41304\" data-end=\"41342\">BIS Certification for Steel Sections<\/li>\n<li data-section-id=\"1givqbe\" data-start=\"41343\" data-end=\"41377\">BIS Certification for Steel Bars<\/li>\n<li data-section-id=\"12dqj6p\" data-start=\"41378\" data-end=\"41424\">BIS Certification for Special Steel Products<\/li>\n<li data-section-id=\"ytuqb7\" data-start=\"41425\" data-end=\"41468\">BIS Certification for High Strength Steel<\/li>\n<li data-section-id=\"1rizx3c\" data-start=\"41469\" data-end=\"41499\">BIS &amp; ISI Mark Certification<\/li>\n<li data-section-id=\"1rdhe7w\" data-start=\"41500\" data-end=\"41535\">BIS Factory Inspection Assistance<\/li>\n<li data-section-id=\"284mi1\" data-start=\"41536\" data-end=\"41562\">BIS Testing Coordination<\/li>\n<\/ul>\n<hr data-start=\"41564\" data-end=\"41567\" \/>\n<h1 data-section-id=\"fsb6xx\" data-start=\"41569\" data-end=\"41581\">Conclusion<\/h1>\n<p data-start=\"41583\" data-end=\"42084\"><strong data-start=\"41583\" data-end=\"41655\">IS 11587:1986 \u2013 Specification for Structural Weather Resistant Steel<\/strong> establishes requirements for high-strength low-alloy weather-resistant structural steels intended for applications where improved atmospheric corrosion resistance is required. BIS&#8217;s technical summary confirms that the standard covers <strong data-start=\"41890\" data-end=\"41935\">plates, sheets, strips, sections and bars<\/strong> and specifies requirements for chemical composition, mechanical properties, dimensions and bend performance.<\/p>\n<p data-start=\"42086\" data-end=\"42337\">The current BIS Product Manual identifies the grades <strong data-start=\"42139\" data-end=\"42203\">WR-Fe 480A, WR-Fe 480B, WR-Fe 490H, WR-Fe 490C and WR-Fe 500<\/strong> and provides product-grouping guidance for flat products, sections, hollow sections and bars.<\/p>\n<p data-start=\"42339\" data-end=\"42668\">IS 11587:1986 is specifically listed under the <strong data-start=\"42386\" data-end=\"42444\">Steel and Steel Products (Quality Control) Order, 2024<\/strong>, with <strong data-start=\"42451\" data-end=\"42486\">immediate-effect implementation<\/strong>. This makes BIS compliance an important requirement for manufacturers supplying covered structural weather resistant steel products in India.<\/p>\n<p data-start=\"42670\" data-end=\"42956\">Manufacturers should pay particular attention to <strong data-start=\"42719\" data-end=\"42955\">grade selection, product form, grouping, chemical composition, weldability, tensile strength, bend and impact requirements, dimensions, defect inspection, heat\/cast traceability, testing facilities, calibration and test certificates<\/strong>.<\/p>\n<p data-start=\"42958\" data-end=\"43218\">The BIS Product Manual specifies a <strong data-start=\"42993\" data-end=\"43027\">1-metre mechanical-test sample<\/strong> and <strong data-start=\"43032\" data-end=\"43100\">five 50 mm \u00d7 50 mm pieces or 100 g drilling for chemical testing<\/strong>, together with detailed requirements for routine testing and quality control.<\/p>\n<p data-start=\"43220\" data-end=\"43506\">Current BIS LIMS information also shows separate laboratory charges for mechanical and chemical testing of IS 11587:1986; one listed laboratory currently shows <strong data-start=\"43380\" data-end=\"43448\">\u20b95,600 for mechanical testing and \u20b98,600 for chemical parameters<\/strong>, excluding taxes.<\/p>\n<p data-start=\"43508\" data-end=\"43830\"><strong data-start=\"43508\" data-end=\"43528\">Qualitance India<\/strong> provides end-to-end <strong data-start=\"43549\" data-end=\"43642\">BIS Certification Consultancy for Structural Weather Resistant Steel as per IS 11587:1986<\/strong>, including product assessment, grade and product-form review, product grouping, documentation, laboratory testing coordination, BIS application support and factory inspection preparation.<\/p>\n<p data-start=\"43832\" data-end=\"43954\"><strong data-start=\"43832\" data-end=\"43954\">For BIS Certification and ISI Mark Consultancy for Structural Weather Resistant Steel, contact Qualitance India today.<\/strong><\/p>\n<p data-start=\"43956\" data-end=\"44055\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"43956\" data-end=\"43966\">Phone:<\/strong> +91 93106 15170<br data-start=\"43982\" data-end=\"43985\" \/><strong data-start=\"43985\" data-end=\"43995\">Email:<\/strong> <a class=\"decorated-link\" href=\"mailto:info@qualitanceindia.com\" rel=\"noopener\" data-start=\"43996\" data-end=\"44020\">info@qualitanceindia.com<\/a><br data-start=\"44020\" data-end=\"44023\" \/><strong data-start=\"44023\" data-end=\"44035\">Website:<\/strong> qualitanceindia.com<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Structural weather resistant steel is a type of high-strength low-alloy structural steel developed to provide improved resistance to atmospheric corrosion. It is intended for structural applications where steel is exposed to outdoor atmospheric conditions and where improved durability and reduced maintenance are important. In India, IS 11587:1986 \u2013 Specification for Structural Weather Resistant Steel [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3579,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"inline_featured_image":false,"slim_seo":{"title":"BIS Certification Consultancy for Structural Weather Resistant Steel | IS 11587:1986 | BIS & ISI Mark Certification - Qualitance India","description":"Introduction Structural weather resistant steel is a type of high-strength low-alloy structural steel developed to provide improved resistance to atmospheric co"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3578","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3578","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3578"}],"version-history":[{"count":1,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3578\/revisions"}],"predecessor-version":[{"id":3580,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3578\/revisions\/3580"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3579"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}<!-- This website is optimized by Airlift. Learn more: https://airlift.net. Template:. Learn more: https://airlift.net. Template: 6a4cebdea01328942bf8f471. Config Timestamp: 2026-07-07 12:06:54 UTC, Cached Timestamp: 2026-09-11 18:20:29 UTC, Optimization Time: 2.24ms -->