{"id":3493,"date":"2026-08-20T10:52:44","date_gmt":"2026-08-20T10:52:44","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3493"},"modified":"2026-10-31T08:15:38","modified_gmt":"2026-10-31T08:15:38","slug":"bis-certification-consultancy-for-tower-bolts-non-ferrous-metals-is-204-part-21992","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-consultancy-for-tower-bolts-non-ferrous-metals-is-204-part-21992\/","title":{"rendered":"BIS Certification Consultancy for Tower Bolts \u2013 Non-Ferrous Metals | IS 204 (Part 2):1992"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"12q1sue\" data-start=\"1123\" data-end=\"1137\">Introduction<\/h2>\n<p data-start=\"1139\" data-end=\"1554\">Tower bolts are commonly used as fastening hardware for doors, windows, cabinets, furniture and other applications where a simple sliding locking arrangement is required. When these products are manufactured from non-ferrous metals such as <strong data-start=\"1379\" data-end=\"1419\">brass, aluminium alloy or zinc alloy<\/strong>, their material quality, dimensions, finish and construction become important factors in determining their performance and durability.<\/p>\n<p data-start=\"1556\" data-end=\"1974\"><strong data-start=\"1556\" data-end=\"1637\">IS 204 (Part 2):1992 \u2013 Tower Bolts \u2013 Specification: Part 2 Non-Ferrous Metals<\/strong> specifies requirements for tower bolts made from non-ferrous metals. BIS includes this product under its certification framework, and the current BIS Product Manual provides guidance on raw materials, product grouping, sample requirements, testing equipment and inspection and testing arrangements.<\/p>\n<p data-start=\"1976\" data-end=\"2275\">The standard covers both <strong data-start=\"2001\" data-end=\"2048\">barrel tower bolts and skeleton tower bolts<\/strong>, with different types based on material and construction. BIS&#8217;s current compulsory-certification listing includes <strong data-start=\"2163\" data-end=\"2221\">IS 204 (Part 2):1992 \u2013 Tower Bolts \u2013 Non-ferrous metal<\/strong> under Scheme-I.<\/p>\n<hr data-start=\"2277\" data-end=\"2280\" \/>\n<h2 data-section-id=\"8tu2tr\" data-start=\"2282\" data-end=\"2322\">About Tower Bolts \u2013 Non-Ferrous Metals<\/h2>\n<p data-start=\"2324\" data-end=\"2510\">A tower bolt is a sliding fastening device generally fitted to a door, window or similar movable panel. The bolt slides into a corresponding keeper or socket to secure the door or panel.<\/p>\n<p data-start=\"2512\" data-end=\"2669\">Non-ferrous tower bolts are manufactured using metals that do not have iron as their principal constituent. Common materials covered by the standard include:<\/p>\n<ul data-start=\"2671\" data-end=\"2709\">\n<li data-section-id=\"16ybz15\" data-start=\"2671\" data-end=\"2678\">Brass<\/li>\n<li data-section-id=\"1f650d8\" data-start=\"2679\" data-end=\"2696\">Aluminium alloy<\/li>\n<li data-section-id=\"1t4zkx\" data-start=\"2697\" data-end=\"2709\">Zinc alloy<\/li>\n<\/ul>\n<p data-start=\"2711\" data-end=\"2864\">These materials can provide suitable corrosion resistance, appearance and service performance when manufactured according to the applicable requirements.<\/p>\n<p data-start=\"2866\" data-end=\"2980\">IS 204 (Part 2):1992 covers <strong data-start=\"2894\" data-end=\"2941\">barrel tower bolts and skeleton tower bolts<\/strong>.<\/p>\n<hr data-start=\"2982\" data-end=\"2985\" \/>\n<h2 data-section-id=\"1hpsc60\" data-start=\"2987\" data-end=\"3018\">What is IS 204 (Part 2):1992?<\/h2>\n<p data-start=\"3020\" data-end=\"3055\"><strong data-start=\"3020\" data-end=\"3044\">IS 204 (Part 2):1992<\/strong> is titled:<\/p>\n<p data-start=\"3057\" data-end=\"3115\"><strong data-start=\"3057\" data-end=\"3115\">Tower Bolts \u2013 Specification: Part 2 Non-Ferrous Metals<\/strong><\/p>\n<p data-start=\"3117\" data-end=\"3196\">The standard lays down requirements for tower bolts made of non-ferrous metals.<\/p>\n<p data-start=\"3198\" data-end=\"3247\">It addresses important characteristics including:<\/p>\n<ul data-start=\"3249\" data-end=\"3359\">\n<li data-section-id=\"v2almr\" data-start=\"3249\" data-end=\"3259\">Material<\/li>\n<li data-section-id=\"zy1zez\" data-start=\"3260\" data-end=\"3272\">Dimensions<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"3273\" data-end=\"3285\">Tolerances<\/li>\n<li data-section-id=\"18mjlfx\" data-start=\"3286\" data-end=\"3299\">Manufacture<\/li>\n<li data-section-id=\"1y3kd2z\" data-start=\"3300\" data-end=\"3308\">Finish<\/li>\n<li data-section-id=\"86lgg8\" data-start=\"3309\" data-end=\"3324\">Product types<\/li>\n<li data-section-id=\"1iohxz6\" data-start=\"3325\" data-end=\"3359\">Applicable material requirements<\/li>\n<\/ul>\n<p data-start=\"3361\" data-end=\"3484\">The standard is currently listed by BIS under its compulsory certification framework.<\/p>\n<hr data-start=\"3486\" data-end=\"3489\" \/>\n<h2 data-section-id=\"wldhh0\" data-start=\"3491\" data-end=\"3522\">Scope of IS 204 (Part 2):1992<\/h2>\n<p data-start=\"3524\" data-end=\"3593\">The standard covers tower bolts manufactured from non-ferrous metals.<\/p>\n<p data-start=\"3595\" data-end=\"3636\">The products are broadly classified into:<\/p>\n<h3 data-section-id=\"fp39bl\" data-start=\"3638\" data-end=\"3660\">Barrel Tower Bolts<\/h3>\n<p data-start=\"3662\" data-end=\"3736\">These tower bolts have a barrel arrangement through which the bolt slides.<\/p>\n<h3 data-section-id=\"1vd7yvu\" data-start=\"3738\" data-end=\"3762\">Skeleton Tower Bolts<\/h3>\n<p data-start=\"3764\" data-end=\"3838\">These have an open or skeleton-type plate and associated bolt arrangement.<\/p>\n<p data-start=\"3840\" data-end=\"4006\">The current BIS Product Manual identifies Types <strong data-start=\"3888\" data-end=\"3898\">1 to 5<\/strong> for barrel tower bolts and Types <strong data-start=\"3932\" data-end=\"3942\">6 to 9<\/strong> for skeleton tower bolts.<\/p>\n<hr data-start=\"4008\" data-end=\"4011\" \/>\n<h2 data-section-id=\"mi9e0l\" data-start=\"4013\" data-end=\"4043\">Types of Tower Bolts Covered<\/h2>\n<p data-start=\"4045\" data-end=\"4092\">According to the current BIS grouping guidance:<\/p>\n<div class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4094\" data-end=\"4427\">\n<thead data-start=\"4094\" data-end=\"4137\">\n<tr data-start=\"4094\" data-end=\"4137\">\n<th class=\"last:pe-10\" data-start=\"4094\" data-end=\"4112\" data-col-size=\"sm\">Tower Bolt Type<\/th>\n<th class=\"last:pe-10\" data-start=\"4112\" data-end=\"4123\" data-col-size=\"sm\">Material<\/th>\n<th class=\"last:pe-10\" data-start=\"4123\" data-end=\"4137\" data-col-size=\"sm\">Size Range<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4152\" data-end=\"4427\">\n<tr data-start=\"4152\" data-end=\"4195\">\n<td data-start=\"4152\" data-end=\"4174\" data-col-size=\"sm\">Barrel Type 1, 2, 3<\/td>\n<td data-start=\"4174\" data-end=\"4182\" data-col-size=\"sm\">Brass<\/td>\n<td data-start=\"4182\" data-end=\"4195\" data-col-size=\"sm\">75\u2013300 mm<\/td>\n<\/tr>\n<tr data-start=\"4196\" data-end=\"4243\">\n<td data-start=\"4196\" data-end=\"4212\" data-col-size=\"sm\">Barrel Type 4<\/td>\n<td data-start=\"4212\" data-end=\"4230\" data-col-size=\"sm\">Aluminium Alloy<\/td>\n<td data-start=\"4230\" data-end=\"4243\" data-col-size=\"sm\">75\u2013300 mm<\/td>\n<\/tr>\n<tr data-start=\"4244\" data-end=\"4286\">\n<td data-start=\"4244\" data-end=\"4260\" data-col-size=\"sm\">Barrel Type 5<\/td>\n<td data-start=\"4260\" data-end=\"4273\" data-col-size=\"sm\">Zinc Alloy<\/td>\n<td data-start=\"4273\" data-end=\"4286\" data-col-size=\"sm\">75\u2013300 mm<\/td>\n<\/tr>\n<tr data-start=\"4287\" data-end=\"4330\">\n<td data-start=\"4287\" data-end=\"4308\" data-col-size=\"sm\">Skeleton Type 6, 7<\/td>\n<td data-start=\"4308\" data-end=\"4316\" data-col-size=\"sm\">Brass<\/td>\n<td data-start=\"4316\" data-end=\"4330\" data-col-size=\"sm\">375\u2013900 mm<\/td>\n<\/tr>\n<tr data-start=\"4331\" data-end=\"4381\">\n<td data-start=\"4331\" data-end=\"4349\" data-col-size=\"sm\">Skeleton Type 8<\/td>\n<td data-start=\"4349\" data-end=\"4367\" data-col-size=\"sm\">Aluminium Alloy<\/td>\n<td data-start=\"4367\" data-end=\"4381\" data-col-size=\"sm\">375\u2013900 mm<\/td>\n<\/tr>\n<tr data-start=\"4382\" data-end=\"4427\">\n<td data-start=\"4382\" data-end=\"4400\" data-col-size=\"sm\">Skeleton Type 9<\/td>\n<td data-start=\"4400\" data-end=\"4413\" data-col-size=\"sm\">Zinc Alloy<\/td>\n<td data-start=\"4413\" data-end=\"4427\" data-col-size=\"sm\">375\u2013900 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"4429\" data-end=\"4572\">The BIS Product Manual gives the detailed grouping basis and identifies the relevant sizes for each type.<\/p>\n<hr data-start=\"4574\" data-end=\"4577\" \/>\n<h2 data-section-id=\"14hon43\" data-start=\"4579\" data-end=\"4610\">Materials Used in Tower Bolts<\/h2>\n<p data-start=\"4612\" data-end=\"4682\">The standard specifies requirements for materials used in tower bolts.<\/p>\n<p data-start=\"4684\" data-end=\"4745\">Depending on the type, tower bolts may be manufactured using:<\/p>\n<h3 data-section-id=\"6xg16f\" data-start=\"4747\" data-end=\"4756\">Brass<\/h3>\n<p data-start=\"4758\" data-end=\"4821\">Used for various barrel and skeleton tower bolt configurations.<\/p>\n<h3 data-section-id=\"dm1yqa\" data-start=\"4823\" data-end=\"4842\">Aluminium Alloy<\/h3>\n<p data-start=\"4844\" data-end=\"4881\">Used for aluminium alloy tower bolts.<\/p>\n<h3 data-section-id=\"s7nr3j\" data-start=\"4883\" data-end=\"4897\">Zinc Alloy<\/h3>\n<p data-start=\"4899\" data-end=\"4965\">Used for zinc-alloy tower bolts, including die-cast constructions.<\/p>\n<p data-start=\"4967\" data-end=\"5152\">The current BIS Product Manual requires raw material to conform to the applicable requirements of <strong data-start=\"5065\" data-end=\"5113\">Clause 4 and Table 3 of IS 204 (Part 2):1992<\/strong>.<\/p>\n<hr data-start=\"5154\" data-end=\"5157\" \/>\n<h2 data-section-id=\"byvlt8\" data-start=\"5159\" data-end=\"5183\">Important Requirements<\/h2>\n<h2 data-section-id=\"1ix3rke\" data-start=\"5185\" data-end=\"5196\">Material<\/h2>\n<p data-start=\"5198\" data-end=\"5301\">The material used for manufacturing tower bolts should meet the requirements specified by the standard.<\/p>\n<h2 data-section-id=\"7q4hfq\" data-start=\"5303\" data-end=\"5316\">Dimensions<\/h2>\n<p data-start=\"5318\" data-end=\"5406\">The dimensions of the tower bolt must conform to the applicable tables and requirements.<\/p>\n<h2 data-section-id=\"1m04p6n\" data-start=\"5408\" data-end=\"5421\">Tolerances<\/h2>\n<p data-start=\"5423\" data-end=\"5502\">Dimensional tolerances must remain within the limits specified by the standard.<\/p>\n<h2 data-section-id=\"s15k0w\" data-start=\"5504\" data-end=\"5518\">Manufacture<\/h2>\n<p data-start=\"5520\" data-end=\"5620\">Tower bolts should be properly manufactured and free from defects that can affect their performance.<\/p>\n<h2 data-section-id=\"2guqoi\" data-start=\"5622\" data-end=\"5641\">Smooth Operation<\/h2>\n<p data-start=\"5643\" data-end=\"5690\">The bolt should operate smoothly and correctly.<\/p>\n<h2 data-section-id=\"vmej3q\" data-start=\"5692\" data-end=\"5701\">Finish<\/h2>\n<p data-start=\"5703\" data-end=\"5824\">The finished product should have a suitable surface finish and should not have unacceptable sharp edges or other defects.<\/p>\n<h2 data-section-id=\"1o9bn4i\" data-start=\"5826\" data-end=\"5838\">Anodizing<\/h2>\n<p data-start=\"5840\" data-end=\"5917\">For applicable aluminium alloy tower bolts, anodizing requirements may apply.<\/p>\n<hr data-start=\"5919\" data-end=\"5922\" \/>\n<h2 data-section-id=\"mkkw31\" data-start=\"5924\" data-end=\"5947\">Manufacturing Process<\/h2>\n<p data-start=\"5949\" data-end=\"6042\">A typical manufacturing process for non-ferrous tower bolts may involve the following stages:<\/p>\n<h3 data-section-id=\"17d7ora\" data-start=\"6044\" data-end=\"6073\">1. Raw Material Selection<\/h3>\n<p data-start=\"6075\" data-end=\"6142\">Suitable brass, aluminium alloy or zinc alloy material is selected.<\/p>\n<h3 data-section-id=\"1i3bj7t\" data-start=\"6144\" data-end=\"6179\">2. Incoming Material Inspection<\/h3>\n<p data-start=\"6181\" data-end=\"6253\">Material composition, dimensions and supplier documentation are checked.<\/p>\n<h3 data-section-id=\"1jpotw\" data-start=\"6255\" data-end=\"6285\">3. Component Manufacturing<\/h3>\n<p data-start=\"6287\" data-end=\"6306\">Components such as:<\/p>\n<ul data-start=\"6308\" data-end=\"6356\">\n<li data-section-id=\"1vo9gki\" data-start=\"6308\" data-end=\"6316\">Barrel<\/li>\n<li data-section-id=\"1j41uxp\" data-start=\"6317\" data-end=\"6323\">Bolt<\/li>\n<li data-section-id=\"1756g9w\" data-start=\"6324\" data-end=\"6331\">Plate<\/li>\n<li data-section-id=\"661gwn\" data-start=\"6332\" data-end=\"6340\">Staple<\/li>\n<li data-section-id=\"1j3vcsg\" data-start=\"6341\" data-end=\"6347\">Knob<\/li>\n<li data-section-id=\"1puavqc\" data-start=\"6348\" data-end=\"6356\">Keeper<\/li>\n<\/ul>\n<p data-start=\"6358\" data-end=\"6418\">are manufactured according to the applicable product design.<\/p>\n<h3 data-section-id=\"1yv37ve\" data-start=\"6420\" data-end=\"6456\">4. Casting \/ Extrusion \/ Forming<\/h3>\n<p data-start=\"6458\" data-end=\"6602\">Depending on the material and product type, components may be produced through casting, extrusion, rolling, drawing or other suitable processes.<\/p>\n<h3 data-section-id=\"ejs4al\" data-start=\"6604\" data-end=\"6620\">5. Machining<\/h3>\n<p data-start=\"6622\" data-end=\"6700\">Necessary machining operations are carried out to achieve required dimensions.<\/p>\n<h3 data-section-id=\"yw5aw1\" data-start=\"6702\" data-end=\"6717\">6. Drilling<\/h3>\n<p data-start=\"6719\" data-end=\"6769\">Screw holes and other required holes are produced.<\/p>\n<h3 data-section-id=\"1t0gtnl\" data-start=\"6771\" data-end=\"6786\">7. Assembly<\/h3>\n<p data-start=\"6788\" data-end=\"6824\">Individual components are assembled.<\/p>\n<h3 data-section-id=\"1e0nb6e\" data-start=\"6826\" data-end=\"6850\">8. Surface Finishing<\/h3>\n<p data-start=\"6852\" data-end=\"6921\">Applicable finishing, polishing, plating or anodizing is carried out.<\/p>\n<h3 data-section-id=\"yxl4wf\" data-start=\"6923\" data-end=\"6940\">9. Inspection<\/h3>\n<p data-start=\"6942\" data-end=\"6981\">The finished tower bolt is checked for:<\/p>\n<ul data-start=\"6983\" data-end=\"7061\">\n<li data-section-id=\"zy1zez\" data-start=\"6983\" data-end=\"6995\">Dimensions<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"6996\" data-end=\"7008\">Tolerances<\/li>\n<li data-section-id=\"1y3kd2z\" data-start=\"7009\" data-end=\"7017\">Finish<\/li>\n<li data-section-id=\"1dpaqql\" data-start=\"7018\" data-end=\"7029\">Operation<\/li>\n<li data-section-id=\"1r54ft5\" data-start=\"7030\" data-end=\"7043\">Workmanship<\/li>\n<li data-section-id=\"1pcnrsr\" data-start=\"7044\" data-end=\"7061\">Surface defects<\/li>\n<\/ul>\n<h3 data-section-id=\"6os3dc\" data-start=\"7063\" data-end=\"7078\">10. Packing<\/h3>\n<p data-start=\"7080\" data-end=\"7161\">Finished products are packed and identified according to applicable requirements.<\/p>\n<hr data-start=\"7163\" data-end=\"7166\" \/>\n<h2 data-section-id=\"1dr8hy4\" data-start=\"7168\" data-end=\"7190\">Testing Requirements<\/h2>\n<p data-start=\"7192\" data-end=\"7242\">Testing is an important part of BIS certification.<\/p>\n<p data-start=\"7244\" data-end=\"7279\">The applicable testing can include:<\/p>\n<ul data-start=\"7281\" data-end=\"7416\">\n<li data-section-id=\"1ujdamn\" data-start=\"7281\" data-end=\"7304\">Material requirements<\/li>\n<li data-section-id=\"zy1zez\" data-start=\"7305\" data-end=\"7317\">Dimensions<\/li>\n<li data-section-id=\"wv2yjz\" data-start=\"7318\" data-end=\"7342\">Dimensional tolerances<\/li>\n<li data-section-id=\"18mjlfx\" data-start=\"7343\" data-end=\"7356\">Manufacture<\/li>\n<li data-section-id=\"1y3kd2z\" data-start=\"7357\" data-end=\"7365\">Finish<\/li>\n<li data-section-id=\"1t4zxef\" data-start=\"7366\" data-end=\"7386\">Visual examination<\/li>\n<li data-section-id=\"xs0t4j\" data-start=\"7387\" data-end=\"7416\">Anodizing, where applicable<\/li>\n<\/ul>\n<p data-start=\"7418\" data-end=\"7625\">BIS laboratory information for IS 204 (Part 2):1992 lists testing under the applicable specification and currently shows laboratory testing availability for the product.<\/p>\n<p data-start=\"7627\" data-end=\"7744\">The exact testing programme should always be checked against the latest BIS Product Manual and applicable amendments.<\/p>\n<hr data-start=\"7746\" data-end=\"7749\" \/>\n<h2 data-section-id=\"u9b84y\" data-start=\"7751\" data-end=\"7769\">Product Grouping<\/h2>\n<p data-start=\"7771\" data-end=\"7882\">Product grouping is particularly important for manufacturers producing multiple tower bolt sizes and materials.<\/p>\n<p data-start=\"7884\" data-end=\"8014\">The <strong data-start=\"7888\" data-end=\"7920\">July 2025 BIS Product Manual<\/strong> provides specific grouping guidelines. It states that the product is classified according to:<\/p>\n<ul data-start=\"8016\" data-end=\"8054\">\n<li data-section-id=\"19tzd9q\" data-start=\"8016\" data-end=\"8029\">Description<\/li>\n<li data-section-id=\"1j4cets\" data-start=\"8030\" data-end=\"8036\">Type<\/li>\n<li data-section-id=\"v2almr\" data-start=\"8037\" data-end=\"8047\">Material<\/li>\n<li data-section-id=\"1j4dcvh\" data-start=\"8048\" data-end=\"8054\">Size<\/li>\n<\/ul>\n<p data-start=\"8056\" data-end=\"8256\">For each applicable type and size range, samples representing the <strong data-start=\"8122\" data-end=\"8151\">smallest and highest size<\/strong> are to be tested to cover the intervening sizes within that range.<\/p>\n<p data-start=\"8258\" data-end=\"8385\">This grouping approach can help manufacturers include multiple sizes within the licence scope while following BIS requirements.<\/p>\n<hr data-start=\"8387\" data-end=\"8390\" \/>\n<h2 data-section-id=\"1vg11y7\" data-start=\"8392\" data-end=\"8412\">Sample Requirement<\/h2>\n<p data-start=\"8414\" data-end=\"8472\">The earlier BIS Product Manual specifies a sample size of:<\/p>\n<p data-start=\"8474\" data-end=\"8538\"><strong data-start=\"8474\" data-end=\"8500\">5 nos. of Tower Bolts.<\/strong><\/p>\n<p data-start=\"8540\" data-end=\"8717\">However, the current Product Manual should be referred to when preparing a new application because BIS may update product manuals, grouping requirements or testing arrangements.<\/p>\n<hr data-start=\"8719\" data-end=\"8722\" \/>\n<h2 data-section-id=\"5mt13u\" data-start=\"8724\" data-end=\"8743\">Testing Equipment<\/h2>\n<p data-start=\"8745\" data-end=\"8891\">Manufacturers applying for BIS certification should maintain suitable testing and measuring facilities according to the applicable Product Manual.<\/p>\n<p data-start=\"8893\" data-end=\"9025\">The BIS Product Manual provides the list of testing equipment through its relevant annexure.<\/p>\n<p data-start=\"9027\" data-end=\"9118\">Depending on the applicable requirements, manufacturers may need arrangements for checking:<\/p>\n<ul data-start=\"9120\" data-end=\"9253\">\n<li data-section-id=\"zy1zez\" data-start=\"9120\" data-end=\"9132\">Dimensions<\/li>\n<li data-section-id=\"1ccfalu\" data-start=\"9133\" data-end=\"9145\">Tolerances<\/li>\n<li data-section-id=\"16dckgd\" data-start=\"9146\" data-end=\"9172\">Material characteristics<\/li>\n<li data-section-id=\"1y3kd2z\" data-start=\"9173\" data-end=\"9181\">Finish<\/li>\n<li data-section-id=\"xs0t4j\" data-start=\"9182\" data-end=\"9211\">Anodizing, where applicable<\/li>\n<li data-section-id=\"c8qwh7\" data-start=\"9212\" data-end=\"9253\">Other specified product characteristics<\/li>\n<\/ul>\n<p data-start=\"9255\" data-end=\"9325\">Measuring equipment should be appropriately maintained and calibrated.<\/p>\n<hr data-start=\"9327\" data-end=\"9330\" \/>\n<h2 data-section-id=\"1mfuv2k\" data-start=\"9332\" data-end=\"9352\">Factory Inspection<\/h2>\n<p data-start=\"9354\" data-end=\"9433\">During BIS factory assessment, the manufacturing facility may be evaluated for:<\/p>\n<h3 data-section-id=\"ptgary\" data-start=\"9435\" data-end=\"9459\">Raw Material Control<\/h3>\n<p data-start=\"9461\" data-end=\"9532\">Verification of brass, aluminium alloy, zinc alloy and other materials.<\/p>\n<h3 data-section-id=\"ihy9m0\" data-start=\"9534\" data-end=\"9561\">Manufacturing Machinery<\/h3>\n<p data-start=\"9563\" data-end=\"9665\">Assessment of casting, extrusion, machining, drilling, forming and finishing machinery, as applicable.<\/p>\n<h3 data-section-id=\"5sl7zi\" data-start=\"9667\" data-end=\"9689\">Production Process<\/h3>\n<p data-start=\"9691\" data-end=\"9736\">Review of the complete manufacturing process.<\/p>\n<h3 data-section-id=\"gr3tzg\" data-start=\"9738\" data-end=\"9757\">Quality Control<\/h3>\n<p data-start=\"9759\" data-end=\"9816\">Inspection of incoming, in-process and finished products.<\/p>\n<h3 data-section-id=\"1y0dmwj\" data-start=\"9818\" data-end=\"9840\">Testing Facilities<\/h3>\n<p data-start=\"9842\" data-end=\"9890\">Verification of testing and measuring equipment.<\/p>\n<h3 data-section-id=\"wzkpnw\" data-start=\"9892\" data-end=\"9907\">Calibration<\/h3>\n<p data-start=\"9909\" data-end=\"9939\">Review of calibration records.<\/p>\n<h3 data-section-id=\"15m401z\" data-start=\"9941\" data-end=\"9967\">Product Identification<\/h3>\n<p data-start=\"9969\" data-end=\"10027\">Checking product types, sizes and material identification.<\/p>\n<h3 data-section-id=\"1btpd0f\" data-start=\"10029\" data-end=\"10040\">Packing<\/h3>\n<p data-start=\"10042\" data-end=\"10089\">Review of product packaging and identification.<\/p>\n<h3 data-section-id=\"1pqkjmg\" data-start=\"10091\" data-end=\"10102\">Records<\/h3>\n<p data-start=\"10104\" data-end=\"10181\">Production, inspection and testing records may be reviewed during assessment.<\/p>\n<hr data-start=\"10183\" data-end=\"10186\" \/>\n<h2 data-section-id=\"14s1v1v\" data-start=\"10188\" data-end=\"10208\">Documents Required<\/h2>\n<p data-start=\"10210\" data-end=\"10270\">Common documents required for BIS certification may include:<\/p>\n<ul data-start=\"10272\" data-end=\"10833\">\n<li data-section-id=\"laj0jm\" data-start=\"10272\" data-end=\"10304\">Company registration documents<\/li>\n<li data-section-id=\"a8o83y\" data-start=\"10305\" data-end=\"10328\">Factory address proof<\/li>\n<li data-section-id=\"17ibqzq\" data-start=\"10329\" data-end=\"10345\">Factory layout<\/li>\n<li data-section-id=\"18vosvl\" data-start=\"10346\" data-end=\"10374\">Manufacturing process flow<\/li>\n<li data-section-id=\"ef1hg\" data-start=\"10375\" data-end=\"10391\">Machinery list<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"10392\" data-end=\"10410\">Product drawings<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"10411\" data-end=\"10435\">Product specifications<\/li>\n<li data-section-id=\"hc0hhc\" data-start=\"10436\" data-end=\"10455\">Product catalogue<\/li>\n<li data-section-id=\"1z01t38\" data-start=\"10456\" data-end=\"10485\">Raw-material specifications<\/li>\n<li data-section-id=\"1xxybf7\" data-start=\"10486\" data-end=\"10514\">Material test certificates<\/li>\n<li data-section-id=\"15xkhnk\" data-start=\"10515\" data-end=\"10535\">Supplier documents<\/li>\n<li data-section-id=\"16dybms\" data-start=\"10536\" data-end=\"10559\">Internal test reports<\/li>\n<li data-section-id=\"o4fj1c\" data-start=\"10560\" data-end=\"10585\">Laboratory test reports<\/li>\n<li data-section-id=\"1fo8gvq\" data-start=\"10586\" data-end=\"10610\">Testing equipment list<\/li>\n<li data-section-id=\"1ymt51g\" data-start=\"10611\" data-end=\"10637\">Calibration certificates<\/li>\n<li data-section-id=\"ku0u1o\" data-start=\"10638\" data-end=\"10660\">Quality-control plan<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"10661\" data-end=\"10681\">Inspection records<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"10682\" data-end=\"10702\">Production records<\/li>\n<li data-section-id=\"684x8w\" data-start=\"10703\" data-end=\"10724\">Product photographs<\/li>\n<li data-section-id=\"1uio16b\" data-start=\"10725\" data-end=\"10742\">Packing details<\/li>\n<li data-section-id=\"1hcgcf\" data-start=\"10743\" data-end=\"10760\">Marking details<\/li>\n<li data-section-id=\"1gg3gcx\" data-start=\"10761\" data-end=\"10793\">Authorized signatory documents<\/li>\n<li data-section-id=\"8zjtnv\" data-start=\"10794\" data-end=\"10833\">Trademark documents, where applicable<\/li>\n<\/ul>\n<p data-start=\"10835\" data-end=\"10911\">The exact documentation depends on the applicant and proposed licence scope.<\/p>\n<hr data-start=\"10913\" data-end=\"10916\" \/>\n<h2 data-section-id=\"1gdjvev\" data-start=\"10918\" data-end=\"10944\">BIS Marking Requirements<\/h2>\n<p data-start=\"10946\" data-end=\"11109\">After obtaining the BIS licence, the manufacturer can use the applicable <strong data-start=\"11019\" data-end=\"11066\">BIS Standard Mark and licence number (CM\/L)<\/strong> according to BIS certification conditions.<\/p>\n<p data-start=\"11111\" data-end=\"11202\">The Standard Mark should only be applied to products covered by the approved licence scope.<\/p>\n<p data-start=\"11204\" data-end=\"11343\">The marking and labelling requirements should be checked against the latest applicable standard, Product Manual and BIS licence conditions.<\/p>\n<hr data-start=\"11345\" data-end=\"11348\" \/>\n<h2 data-section-id=\"dsplc4\" data-start=\"11350\" data-end=\"11367\">QCO Requirement<\/h2>\n<p data-start=\"11369\" data-end=\"11467\">Tower Bolts \u2013 Non-Ferrous Metals are included in the BIS compulsory certification framework under:<\/p>\n<p data-start=\"11469\" data-end=\"11493\"><strong data-start=\"11469\" data-end=\"11493\">IS 204 (Part 2):1992<\/strong><\/p>\n<p data-start=\"11495\" data-end=\"11647\">BIS&#8217;s current Scheme-I listing specifically includes <strong data-start=\"11548\" data-end=\"11606\">IS 204 (Part 2):1992 \u2013 Tower Bolts \u2013 Non-ferrous metal<\/strong>.<\/p>\n<p data-start=\"11649\" data-end=\"11907\">The BIS technical publication also states that the applicable Quality Control Order requires covered tower bolts manufactured, sold or imported in India to comply with IS 204 (Part 2) and display the BIS Standard Mark.<\/p>\n<p data-start=\"11909\" data-end=\"12087\">Manufacturers, importers and sellers should therefore verify the latest QCO and implementation requirements applicable to their products before placing them on the Indian market.<\/p>\n<hr data-start=\"12089\" data-end=\"12092\" \/>\n<h2 data-section-id=\"2uzze8\" data-start=\"12094\" data-end=\"12124\">Who Needs BIS Certification?<\/h2>\n<p data-start=\"12126\" data-end=\"12230\">BIS certification can be relevant to manufacturers producing covered non-ferrous tower bolts, including:<\/p>\n<ul data-start=\"12232\" data-end=\"12575\">\n<li data-section-id=\"nh43gi\" data-start=\"12232\" data-end=\"12258\">Tower bolt manufacturers<\/li>\n<li data-section-id=\"l9xhyr\" data-start=\"12259\" data-end=\"12291\">Builder hardware manufacturers<\/li>\n<li data-section-id=\"5a42dv\" data-start=\"12292\" data-end=\"12324\">Brass tower bolt manufacturers<\/li>\n<li data-section-id=\"89v8gx\" data-start=\"12325\" data-end=\"12361\">Aluminium tower bolt manufacturers<\/li>\n<li data-section-id=\"f71rzf\" data-start=\"12362\" data-end=\"12399\">Zinc alloy tower bolt manufacturers<\/li>\n<li data-section-id=\"wd5g78\" data-start=\"12400\" data-end=\"12429\">Door hardware manufacturers<\/li>\n<li data-section-id=\"1hu4eim\" data-start=\"12430\" data-end=\"12461\">Window hardware manufacturers<\/li>\n<li data-section-id=\"17p7t5h\" data-start=\"12462\" data-end=\"12490\">Hardware OEM manufacturers<\/li>\n<li data-section-id=\"1mi7k3i\" data-start=\"12491\" data-end=\"12515\">Contract manufacturers<\/li>\n<li data-section-id=\"1eenvr8\" data-start=\"12516\" data-end=\"12575\">Export-oriented manufacturers supplying the Indian market<\/li>\n<\/ul>\n<p data-start=\"12577\" data-end=\"12661\">Importers should separately review the requirements applicable to imported products.<\/p>\n<hr data-start=\"12663\" data-end=\"12666\" \/>\n<h2 data-section-id=\"1jwi5nr\" data-start=\"12668\" data-end=\"12694\">Eligibility Requirements<\/h2>\n<p data-start=\"12696\" data-end=\"12733\">A manufacturer should generally have:<\/p>\n<ul data-start=\"12735\" data-end=\"13082\">\n<li data-section-id=\"7955j3\" data-start=\"12735\" data-end=\"12768\">Suitable manufacturing premises<\/li>\n<li data-section-id=\"u3k2zl\" data-start=\"12769\" data-end=\"12792\">Appropriate machinery<\/li>\n<li data-section-id=\"hzbrql\" data-start=\"12793\" data-end=\"12815\">Raw-material control<\/li>\n<li data-section-id=\"1ipfuuo\" data-start=\"12816\" data-end=\"12834\">Product drawings<\/li>\n<li data-section-id=\"xvoj65\" data-start=\"12835\" data-end=\"12859\">Product specifications<\/li>\n<li data-section-id=\"9narjl\" data-start=\"12860\" data-end=\"12888\">Quality-control procedures<\/li>\n<li data-section-id=\"1tby26r\" data-start=\"12889\" data-end=\"12911\">Testing arrangements<\/li>\n<li data-section-id=\"1a59xzw\" data-start=\"12912\" data-end=\"12944\">Calibrated measuring equipment<\/li>\n<li data-section-id=\"qg7q9h\" data-start=\"12945\" data-end=\"12965\">Production records<\/li>\n<li data-section-id=\"1mwzt1k\" data-start=\"12966\" data-end=\"12986\">Inspection records<\/li>\n<li data-section-id=\"15dnans\" data-start=\"12987\" data-end=\"13017\">Suitable technical personnel<\/li>\n<li data-section-id=\"4dnixi\" data-start=\"13018\" data-end=\"13047\">Proper storage arrangements<\/li>\n<li data-section-id=\"1tjj876\" data-start=\"13048\" data-end=\"13082\">Packing and marking arrangements<\/li>\n<\/ul>\n<hr data-start=\"13084\" data-end=\"13087\" \/>\n<h2 data-section-id=\"100aerd\" data-start=\"13089\" data-end=\"13130\">Common Reasons for Certification Delays<\/h2>\n<p data-start=\"13132\" data-end=\"13173\">Manufacturers may face delays because of:<\/p>\n<ul data-start=\"13175\" data-end=\"13662\">\n<li data-section-id=\"h0xmh6\" data-start=\"13175\" data-end=\"13205\">Incorrect standard selection<\/li>\n<li data-section-id=\"1vlzjnw\" data-start=\"13206\" data-end=\"13240\">Incorrect product classification<\/li>\n<li data-section-id=\"1e5dcww\" data-start=\"13241\" data-end=\"13269\">Wrong material declaration<\/li>\n<li data-section-id=\"1lyyp0l\" data-start=\"13270\" data-end=\"13298\">Incorrect product grouping<\/li>\n<li data-section-id=\"fz3ggz\" data-start=\"13299\" data-end=\"13328\">Inadequate product drawings<\/li>\n<li data-section-id=\"1tyl2ef\" data-start=\"13329\" data-end=\"13357\">Dimensional non-conformity<\/li>\n<li data-section-id=\"i4el8h\" data-start=\"13358\" data-end=\"13377\">Tolerance failure<\/li>\n<li data-section-id=\"ms67v0\" data-start=\"13378\" data-end=\"13399\">Poor surface finish<\/li>\n<li data-section-id=\"gm4u2o\" data-start=\"13400\" data-end=\"13413\">Sharp edges<\/li>\n<li data-section-id=\"1k3012\" data-start=\"13414\" data-end=\"13439\">Improper bolt operation<\/li>\n<li data-section-id=\"nj6t0z\" data-start=\"13440\" data-end=\"13473\">Material-related non-conformity<\/li>\n<li data-section-id=\"of70lz\" data-start=\"13474\" data-end=\"13500\">Anodizing-related issues<\/li>\n<li data-section-id=\"jaist4\" data-start=\"13501\" data-end=\"13530\">Missing calibration records<\/li>\n<li data-section-id=\"mhdfy8\" data-start=\"13531\" data-end=\"13564\">Inadequate testing arrangements<\/li>\n<li data-section-id=\"ggwkkk\" data-start=\"13565\" data-end=\"13584\">Incorrect samples<\/li>\n<li data-section-id=\"cbjogq\" data-start=\"13585\" data-end=\"13607\">Incomplete documents<\/li>\n<li data-section-id=\"15z8wbz\" data-start=\"13608\" data-end=\"13642\">Factory not ready for assessment<\/li>\n<li data-section-id=\"1q7qwro\" data-start=\"13643\" data-end=\"13662\">Incorrect marking<\/li>\n<\/ul>\n<p data-start=\"13664\" data-end=\"13749\">Proper preparation before submitting the BIS application can reduce avoidable issues.<\/p>\n<hr data-start=\"13751\" data-end=\"13754\" \/>\n<h2 data-section-id=\"1s7abhg\" data-start=\"13756\" data-end=\"13783\">Cost of BIS Certification<\/h2>\n<p data-start=\"13785\" data-end=\"13825\">The total certification cost depends on:<\/p>\n<ul data-start=\"13827\" data-end=\"14076\">\n<li data-section-id=\"wndo83\" data-start=\"13827\" data-end=\"13852\">BIS application charges<\/li>\n<li data-section-id=\"khts3h\" data-start=\"13853\" data-end=\"13873\">Laboratory testing<\/li>\n<li data-section-id=\"il0m2q\" data-start=\"13874\" data-end=\"13899\">Number of product types<\/li>\n<li data-section-id=\"150fhwa\" data-start=\"13900\" data-end=\"13921\">Number of materials<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"13922\" data-end=\"13940\">Product grouping<\/li>\n<li data-section-id=\"1cjf8hg\" data-start=\"13941\" data-end=\"13958\">Number of sizes<\/li>\n<li data-section-id=\"hrwpmc\" data-start=\"13959\" data-end=\"13978\">Testing equipment<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"13979\" data-end=\"13999\">Factory assessment<\/li>\n<li data-section-id=\"zkwwle\" data-start=\"14000\" data-end=\"14013\">Calibration<\/li>\n<li data-section-id=\"w80kxv\" data-start=\"14014\" data-end=\"14038\">Retesting, if required<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"14039\" data-end=\"14054\">Documentation<\/li>\n<li data-section-id=\"1q8f3t4\" data-start=\"14055\" data-end=\"14076\">Consultancy charges<\/li>\n<\/ul>\n<p data-start=\"14078\" data-end=\"14262\">BIS LIMS currently shows a listed testing charge for IS 204 Part 2, although the final cost depends on the actual scope and laboratory selected.<\/p>\n<hr data-start=\"14264\" data-end=\"14267\" \/>\n<h2 data-section-id=\"1a3o6ed\" data-start=\"14269\" data-end=\"14293\">Certification Timeline<\/h2>\n<p data-start=\"14295\" data-end=\"14342\">The time required for certification depends on:<\/p>\n<ul data-start=\"14344\" data-end=\"14533\">\n<li data-section-id=\"r86jf7\" data-start=\"14344\" data-end=\"14363\">Product readiness<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"14364\" data-end=\"14379\">Documentation<\/li>\n<li data-section-id=\"xjlpof\" data-start=\"14380\" data-end=\"14401\">Sample availability<\/li>\n<li data-section-id=\"khts3h\" data-start=\"14402\" data-end=\"14422\">Laboratory testing<\/li>\n<li data-section-id=\"xkasf8\" data-start=\"14423\" data-end=\"14437\">Test results<\/li>\n<li data-section-id=\"2g4cch\" data-start=\"14438\" data-end=\"14466\">BIS application processing<\/li>\n<li data-section-id=\"1213b4c\" data-start=\"14467\" data-end=\"14486\">Factory readiness<\/li>\n<li data-section-id=\"1rqeiju\" data-start=\"14487\" data-end=\"14507\">Factory assessment<\/li>\n<li data-section-id=\"1rqzqpt\" data-start=\"14508\" data-end=\"14533\">Closure of observations<\/li>\n<\/ul>\n<p data-start=\"14535\" data-end=\"14637\">Manufacturers with multiple materials and sizes should finalise their product grouping before testing.<\/p>\n<hr data-start=\"14639\" data-end=\"14642\" \/>\n<h2 data-section-id=\"wv2e8b\" data-start=\"14644\" data-end=\"14675\">Benefits of BIS Certification<\/h2>\n<h3 data-section-id=\"1s6jna8\" data-start=\"14677\" data-end=\"14696\">Product Quality<\/h3>\n<p data-start=\"14698\" data-end=\"14753\">Testing helps verify important product characteristics.<\/p>\n<h3 data-section-id=\"15cgiwz\" data-start=\"14755\" data-end=\"14780\">Regulatory Compliance<\/h3>\n<p data-start=\"14782\" data-end=\"14842\">Helps manufacturers comply with applicable BIS requirements.<\/p>\n<h3 data-section-id=\"k08kti\" data-start=\"14844\" data-end=\"14867\">Customer Confidence<\/h3>\n<p data-start=\"14869\" data-end=\"14917\">BIS certification can increase buyer confidence.<\/p>\n<h3 data-section-id=\"s62ca3\" data-start=\"14919\" data-end=\"14940\">Market Acceptance<\/h3>\n<p data-start=\"14942\" data-end=\"15017\">Certification supports market access where BIS certification is compulsory.<\/p>\n<h3 data-section-id=\"11p05yp\" data-start=\"15019\" data-end=\"15051\">Better Manufacturing Control<\/h3>\n<p data-start=\"15053\" data-end=\"15118\">Quality-control arrangements help maintain consistent production.<\/p>\n<h3 data-section-id=\"1hb4bh9\" data-start=\"15120\" data-end=\"15143\">Product Reliability<\/h3>\n<p data-start=\"15145\" data-end=\"15233\">Proper dimensions, material and workmanship contribute to reliable tower bolt operation.<\/p>\n<h3 data-section-id=\"517a1m\" data-start=\"15235\" data-end=\"15259\">Business Credibility<\/h3>\n<p data-start=\"15261\" data-end=\"15353\">BIS certification can strengthen the manufacturer&#8217;s position in the builder hardware market.<\/p>\n<hr data-start=\"15355\" data-end=\"15358\" \/>\n<h2 data-section-id=\"18jhjpw\" data-start=\"15360\" data-end=\"15390\">Why Choose Qualitance India?<\/h2>\n<p data-start=\"15392\" data-end=\"15536\"><strong data-start=\"15392\" data-end=\"15412\">Qualitance India<\/strong> provides BIS certification consultancy for builder hardware, fasteners and various products covered under Indian Standards.<\/p>\n<p data-start=\"15538\" data-end=\"15631\">For <strong data-start=\"15542\" data-end=\"15606\">Tower Bolts \u2013 Non-Ferrous Metals as per IS 204 (Part 2):1992<\/strong>, assistance can include:<\/p>\n<ul data-start=\"15633\" data-end=\"16059\">\n<li data-section-id=\"1mfdgr4\" data-start=\"15633\" data-end=\"15667\">Product applicability assessment<\/li>\n<li data-section-id=\"pkfmba\" data-start=\"15668\" data-end=\"15697\">Standard requirement review<\/li>\n<li data-section-id=\"ykvcbu\" data-start=\"15698\" data-end=\"15725\">Product grouping guidance<\/li>\n<li data-section-id=\"1o769sl\" data-start=\"15726\" data-end=\"15747\">Material assessment<\/li>\n<li data-section-id=\"u9g71k\" data-start=\"15748\" data-end=\"15774\">Size and type assessment<\/li>\n<li data-section-id=\"16jeez9\" data-start=\"15775\" data-end=\"15798\">Documentation support<\/li>\n<li data-section-id=\"o31ggr\" data-start=\"15799\" data-end=\"15827\">Testing requirement review<\/li>\n<li data-section-id=\"1kzgx2c\" data-start=\"15828\" data-end=\"15853\">Laboratory coordination<\/li>\n<li data-section-id=\"1vcb8rl\" data-start=\"15854\" data-end=\"15883\">Sample preparation guidance<\/li>\n<li data-section-id=\"maajyk\" data-start=\"15884\" data-end=\"15912\">BIS application assistance<\/li>\n<li data-section-id=\"sy9ixn\" data-start=\"15913\" data-end=\"15945\">Factory inspection preparation<\/li>\n<li data-section-id=\"1bxrev1\" data-start=\"15946\" data-end=\"15977\">Quality-control documentation<\/li>\n<li data-section-id=\"7nbtgf\" data-start=\"15978\" data-end=\"16004\">Test report coordination<\/li>\n<li data-section-id=\"1dssdod\" data-start=\"16005\" data-end=\"16037\">Observation closure assistance<\/li>\n<li data-section-id=\"1imghg4\" data-start=\"16038\" data-end=\"16059\">BIS licence support<\/li>\n<\/ul>\n<h3 data-section-id=\"16z2skw\" data-start=\"16061\" data-end=\"16089\">Contact Qualitance India<\/h3>\n<p data-start=\"16091\" data-end=\"16200\"><strong data-start=\"16091\" data-end=\"16101\">Phone:<\/strong> +91-9310-615-170<br data-start=\"16118\" data-end=\"16121\" \/><strong data-start=\"16121\" data-end=\"16131\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"16132\" data-end=\"16156\">info@qualitanceindia.com<\/a><br data-start=\"16156\" data-end=\"16159\" \/><strong data-start=\"16159\" data-end=\"16171\">Website:<\/strong> <a class=\"decorated-link\" href=\"https:\/\/qualitanceindia.com\/\" target=\"_new\" rel=\"noopener\" data-start=\"16172\" data-end=\"16200\">https:\/\/qualitanceindia.com\/<\/a><\/p>\n<hr data-start=\"16202\" data-end=\"16205\" \/>\n<h2 data-section-id=\"ayo1bh\" data-start=\"16207\" data-end=\"16234\">BIS Certification Process<\/h2>\n<p data-start=\"16236\" data-end=\"16718\"><strong data-start=\"16236\" data-end=\"16262\">Product Identification<\/strong><br data-start=\"16262\" data-end=\"16265\" \/>\u2193<br data-start=\"16266\" data-end=\"16269\" \/><strong data-start=\"16269\" data-end=\"16312\">IS 204 (Part 2):1992 Requirement Review<\/strong><br data-start=\"16312\" data-end=\"16315\" \/>\u2193<br data-start=\"16316\" data-end=\"16319\" \/><strong data-start=\"16319\" data-end=\"16357\">Material &amp; Product Type Assessment<\/strong><br data-start=\"16357\" data-end=\"16360\" \/>\u2193<br data-start=\"16361\" data-end=\"16364\" \/><strong data-start=\"16364\" data-end=\"16393\">Size and Product Grouping<\/strong><br data-start=\"16393\" data-end=\"16396\" \/>\u2193<br data-start=\"16397\" data-end=\"16400\" \/><strong data-start=\"16400\" data-end=\"16429\">Raw Material Verification<\/strong><br data-start=\"16429\" data-end=\"16432\" \/>\u2193<br data-start=\"16433\" data-end=\"16436\" \/><strong data-start=\"16436\" data-end=\"16465\">Documentation Preparation<\/strong><br data-start=\"16465\" data-end=\"16468\" \/>\u2193<br data-start=\"16469\" data-end=\"16472\" \/><strong data-start=\"16472\" data-end=\"16492\">Sample Selection<\/strong><br data-start=\"16492\" data-end=\"16495\" \/>\u2193<br data-start=\"16496\" data-end=\"16499\" \/><strong data-start=\"16499\" data-end=\"16521\">Laboratory Testing<\/strong><br data-start=\"16521\" data-end=\"16524\" \/>\u2193<br data-start=\"16525\" data-end=\"16528\" \/><strong data-start=\"16528\" data-end=\"16547\">BIS Application<\/strong><br data-start=\"16547\" data-end=\"16550\" \/>\u2193<br data-start=\"16551\" data-end=\"16554\" \/><strong data-start=\"16554\" data-end=\"16570\">BIS Scrutiny<\/strong><br data-start=\"16570\" data-end=\"16573\" \/>\u2193<br data-start=\"16574\" data-end=\"16577\" \/><strong data-start=\"16577\" data-end=\"16599\">Factory Assessment<\/strong><br data-start=\"16599\" data-end=\"16602\" \/>\u2193<br data-start=\"16603\" data-end=\"16606\" \/><strong data-start=\"16606\" data-end=\"16632\">Test Report Evaluation<\/strong><br data-start=\"16632\" data-end=\"16635\" \/>\u2193<br data-start=\"16636\" data-end=\"16639\" \/><strong data-start=\"16639\" data-end=\"16662\">Observation Closure<\/strong><br data-start=\"16662\" data-end=\"16665\" \/>\u2193<br data-start=\"16666\" data-end=\"16669\" \/><strong data-start=\"16669\" data-end=\"16690\">BIS Licence Grant<\/strong><br data-start=\"16690\" data-end=\"16693\" \/>\u2193<br data-start=\"16694\" data-end=\"16697\" \/><strong data-start=\"16697\" data-end=\"16718\">BIS Standard Mark<\/strong><\/p>\n<hr data-start=\"16720\" data-end=\"16723\" \/>\n<h2 data-section-id=\"hkd5a4\" data-start=\"16725\" data-end=\"16753\">Frequently Asked Questions<\/h2>\n<h3 data-section-id=\"1c06iuf\" data-start=\"16755\" data-end=\"16791\">1. What is IS 204 (Part 2):1992?<\/h3>\n<p data-start=\"16793\" data-end=\"16940\">IS 204 (Part 2):1992 is the Indian Standard for <strong data-start=\"16841\" data-end=\"16899\">Tower Bolts \u2013 Specification: Part 2 Non-Ferrous Metals<\/strong>.<\/p>\n<h3 data-section-id=\"c0x6lo\" data-start=\"16942\" data-end=\"16982\">2. What are non-ferrous tower bolts?<\/h3>\n<p data-start=\"16984\" data-end=\"17091\">They are tower bolts manufactured from non-ferrous materials such as brass, aluminium alloy and zinc alloy.<\/p>\n<h3 data-section-id=\"i0ljiy\" data-start=\"17093\" data-end=\"17147\">3. Which products are covered under IS 204 Part 2?<\/h3>\n<p data-start=\"17149\" data-end=\"17276\">The standard covers non-ferrous metal tower bolts, including barrel and skeleton types.<\/p>\n<h3 data-section-id=\"c2iows\" data-start=\"17278\" data-end=\"17313\">4. Which materials are covered?<\/h3>\n<p data-start=\"17315\" data-end=\"17465\">The BIS grouping guidance identifies brass, aluminium alloy and zinc alloy for the specified tower bolt types.<\/p>\n<h3 data-section-id=\"1ruxeyl\" data-start=\"17467\" data-end=\"17520\">5. What is the size range for barrel tower bolts?<\/h3>\n<p data-start=\"17522\" data-end=\"17673\">The current grouping guidance identifies sizes from <strong data-start=\"17574\" data-end=\"17593\">75 mm to 300 mm<\/strong> for the listed barrel tower bolt types.<\/p>\n<h3 data-section-id=\"pn0r91\" data-start=\"17675\" data-end=\"17730\">6. What is the size range for skeleton tower bolts?<\/h3>\n<p data-start=\"17732\" data-end=\"17886\">The current grouping guidance identifies sizes from <strong data-start=\"17784\" data-end=\"17804\">375 mm to 900 mm<\/strong> for the listed skeleton tower bolt types.<\/p>\n<h3 data-section-id=\"rhp3x\" data-start=\"17888\" data-end=\"17953\">7. Is BIS certification required for non-ferrous tower bolts?<\/h3>\n<p data-start=\"17955\" data-end=\"18093\">IS 204 (Part 2):1992 is included in BIS&#8217;s current compulsory certification listing under Scheme-I.<\/p>\n<h3 data-section-id=\"1s59a6k\" data-start=\"18095\" data-end=\"18133\">8. Is product grouping applicable?<\/h3>\n<p data-start=\"18135\" data-end=\"18253\">Yes. BIS provides specific grouping guidance based on type, material and size.<\/p>\n<h3 data-section-id=\"t2ji14\" data-start=\"18255\" data-end=\"18308\">9. Which samples are tested for product grouping?<\/h3>\n<p data-start=\"18310\" data-end=\"18488\">The current grouping guidance specifies testing one sample each of the smallest and highest size from each applicable type and size range.<\/p>\n<h3 data-section-id=\"4ydg4f\" data-start=\"18490\" data-end=\"18523\">10. What tests are performed?<\/h3>\n<p data-start=\"18525\" data-end=\"18633\">Testing can include material, dimensions, tolerances, manufacture, finish and other applicable requirements.<\/p>\n<h3 data-section-id=\"opg2gp\" data-start=\"18635\" data-end=\"18672\">11. Is material testing required?<\/h3>\n<p data-start=\"18674\" data-end=\"18816\">Material must comply with the applicable requirements of Clause 4 and Table 3 of IS 204 (Part 2):1992.<\/p>\n<h3 data-section-id=\"184055a\" data-start=\"18818\" data-end=\"18846\">12. Is anodizing tested?<\/h3>\n<p data-start=\"18848\" data-end=\"18923\">Anodizing can be an applicable requirement for aluminium alloy tower bolts.<\/p>\n<h3 data-section-id=\"19i66ng\" data-start=\"18925\" data-end=\"18964\">13. Is factory inspection required?<\/h3>\n<p data-start=\"18966\" data-end=\"19052\">Factory assessment is part of the applicable BIS certification process under Scheme-I.<\/p>\n<h3 data-section-id=\"1olirej\" data-start=\"19054\" data-end=\"19090\">14. What documents are required?<\/h3>\n<p data-start=\"19092\" data-end=\"19288\">Typical documents include factory details, product drawings, raw-material information, manufacturing process, machinery list, testing arrangements, calibration records and quality-control records.<\/p>\n<h3 data-section-id=\"1muj7la\" data-start=\"19290\" data-end=\"19356\">15. Can a manufacturer include different sizes in one licence?<\/h3>\n<p data-start=\"19358\" data-end=\"19519\">Potentially yes, subject to the applicable BIS grouping rules and the manufacturer&#8217;s testing and production capabilities.<\/p>\n<h3 data-section-id=\"3fvqbs\" data-start=\"19521\" data-end=\"19597\">16. Can brass and aluminium tower bolts be included in the same licence?<\/h3>\n<p data-start=\"19599\" data-end=\"19725\">The licence scope and grouping need to be determined according to the applicable type, material and BIS grouping requirements.<\/p>\n<h3 data-section-id=\"1axo8k3\" data-start=\"19727\" data-end=\"19773\">17. What is the BIS certification process?<\/h3>\n<p data-start=\"19775\" data-end=\"19913\">It generally involves product assessment, grouping, documentation, testing, BIS application, factory assessment and conformity evaluation.<\/p>\n<h3 data-section-id=\"k0ixb5\" data-start=\"19915\" data-end=\"19979\">18. Can Qualitance India help with tower bolt certification?<\/h3>\n<p data-start=\"19981\" data-end=\"20151\">Yes. Qualitance India can assist manufacturers with product assessment, grouping, documentation, testing coordination, BIS application and factory inspection preparation.<\/p>\n<hr data-start=\"20153\" data-end=\"20156\" \/>\n<h2 data-section-id=\"g38lxp\" data-start=\"20158\" data-end=\"20175\">People Also Ask<\/h2>\n<h3 data-section-id=\"1ws4c0t\" data-start=\"20177\" data-end=\"20234\">What is the BIS standard for non-ferrous tower bolts?<\/h3>\n<p data-start=\"20236\" data-end=\"20288\">The applicable standard is <strong data-start=\"20263\" data-end=\"20287\">IS 204 (Part 2):1992<\/strong>.<\/p>\n<h3 data-section-id=\"lzya1p\" data-start=\"20290\" data-end=\"20321\">Is IS 204 Part 2 mandatory?<\/h3>\n<p data-start=\"20323\" data-end=\"20435\">It is included in BIS&#8217;s compulsory certification listing under Scheme-I.<\/p>\n<h3 data-section-id=\"5h0z7y\" data-start=\"20437\" data-end=\"20490\">What metals are used for non-ferrous tower bolts?<\/h3>\n<p data-start=\"20492\" data-end=\"20607\">Common materials covered include <strong data-start=\"20525\" data-end=\"20566\">brass, aluminium alloy and zinc alloy<\/strong>.<\/p>\n<h3 data-section-id=\"7pb6mq\" data-start=\"20609\" data-end=\"20641\">What are barrel tower bolts?<\/h3>\n<p data-start=\"20643\" data-end=\"20736\">Barrel tower bolts have a tubular\/barrel arrangement through which the sliding bolt operates.<\/p>\n<h3 data-section-id=\"24q6hl\" data-start=\"20738\" data-end=\"20772\">What are skeleton tower bolts?<\/h3>\n<p data-start=\"20774\" data-end=\"20870\">Skeleton tower bolts use an open or skeleton-type plate and associated sliding bolt arrangement.<\/p>\n<h3 data-section-id=\"pfvq2m\" data-start=\"20872\" data-end=\"20919\">What sizes are covered under IS 204 Part 2?<\/h3>\n<p data-start=\"20921\" data-end=\"21129\">The current BIS grouping guidance identifies barrel tower bolt sizes from <strong data-start=\"20995\" data-end=\"21011\">75 to 300 mm<\/strong> and skeleton tower bolt sizes from <strong data-start=\"21047\" data-end=\"21064\">375 to 900 mm<\/strong> for the specified types.<\/p>\n<h3 data-section-id=\"k2v985\" data-start=\"21131\" data-end=\"21186\">How can I obtain BIS certification for tower bolts?<\/h3>\n<p data-start=\"21188\" data-end=\"21381\">A manufacturer needs to identify the applicable product type and material, prepare representative samples and documents, complete the required testing and undergo the BIS certification process.<\/p>\n<hr data-start=\"21383\" data-end=\"21386\" \/>\n<h2 data-section-id=\"m4n0jr\" data-start=\"21388\" data-end=\"21408\">Website Image Text<\/h2>\n<p data-start=\"21410\" data-end=\"21446\"><strong data-start=\"21410\" data-end=\"21446\">TOWER BOLTS \u2013 NON-FERROUS METALS<\/strong><\/p>\n<p data-start=\"21448\" data-end=\"21472\"><strong data-start=\"21448\" data-end=\"21472\">IS 204 (PART 2):1992<\/strong><\/p>\n<p data-start=\"21474\" data-end=\"21507\"><strong data-start=\"21474\" data-end=\"21507\">BIS CERTIFICATION CONSULTANCY<\/strong><\/p>\n<p data-start=\"21509\" data-end=\"21549\"><strong data-start=\"21509\" data-end=\"21549\">BRASS | ALUMINIUM ALLOY | ZINC ALLOY<\/strong><\/p>\n<p data-start=\"21551\" data-end=\"21571\"><strong data-start=\"21551\" data-end=\"21571\">Qualitance India<\/strong><\/p>\n<p data-start=\"21573\" data-end=\"21650\"><strong data-start=\"21573\" data-end=\"21593\">+91-9310-615-170<\/strong><br data-start=\"21593\" data-end=\"21596\" \/><strong data-start=\"21596\" data-end=\"21624\"><a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"21598\" data-end=\"21622\">info@qualitanceindia.com<\/a><\/strong><br data-start=\"21624\" data-end=\"21627\" \/><strong data-start=\"21627\" data-end=\"21650\">qualitanceindia.com<\/strong><\/p>\n<hr data-start=\"21652\" data-end=\"21655\" \/>\n<h2 data-section-id=\"30zj4z\" data-start=\"21657\" data-end=\"21681\">Image Text Suggestions<\/h2>\n<ol data-start=\"21683\" data-end=\"22198\">\n<li data-section-id=\"nykbr0\" data-start=\"21683\" data-end=\"21719\">BIS Certification for Tower Bolts<\/li>\n<li data-section-id=\"1uky0kp\" data-start=\"21720\" data-end=\"21741\">IS 204 Part 2:1992<\/li>\n<li data-section-id=\"s2hhu5\" data-start=\"21742\" data-end=\"21786\">Non-Ferrous Tower Bolts BIS Certification<\/li>\n<li data-section-id=\"1lxrl1m\" data-start=\"21787\" data-end=\"21817\">BIS Licence for Tower Bolts<\/li>\n<li data-section-id=\"g23vq1\" data-start=\"21818\" data-end=\"21851\">Brass Tower Bolt Certification<\/li>\n<li data-section-id=\"1e2kuy0\" data-start=\"21852\" data-end=\"21889\">Aluminium Tower Bolt Certification<\/li>\n<li data-section-id=\"153mutf\" data-start=\"21890\" data-end=\"21928\">Zinc Alloy Tower Bolt Certification<\/li>\n<li data-section-id=\"1e8zjfv\" data-start=\"21929\" data-end=\"21950\">Tower Bolt Testing<\/li>\n<li data-section-id=\"1ihe52u\" data-start=\"21951\" data-end=\"21983\">Tower Bolt Factory Inspection<\/li>\n<li data-section-id=\"sry5p1\" data-start=\"21984\" data-end=\"22009\">IS 204 Part 2 Testing<\/li>\n<li data-section-id=\"1dsyc33\" data-start=\"22010\" data-end=\"22052\">BIS Certification for Builder Hardware<\/li>\n<li data-section-id=\"uqbv0\" data-start=\"22053\" data-end=\"22086\">Non-Ferrous Metal Tower Bolts<\/li>\n<li data-section-id=\"k8si3g\" data-start=\"22087\" data-end=\"22117\">Tower Bolt Quality Testing<\/li>\n<li data-section-id=\"esd9v6\" data-start=\"22118\" data-end=\"22161\">BIS Licence Consultancy for Tower Bolts<\/li>\n<li data-section-id=\"1jcimmg\" data-start=\"22162\" data-end=\"22198\">Qualitance India BIS Consultancy<\/li>\n<\/ol>\n<hr data-start=\"22200\" data-end=\"22203\" \/>\n<h2 data-section-id=\"1mk48w7\" data-start=\"22205\" data-end=\"22223\">Related Services<\/h2>\n<ul data-start=\"22225\" data-end=\"22652\">\n<li data-section-id=\"1pqhorg\" data-start=\"22225\" data-end=\"22286\">BIS Certification for Ferrous Tower Bolts \u2013 IS 204 (Part 1)<\/li>\n<li data-section-id=\"4iq28o\" data-start=\"22287\" data-end=\"22349\">BIS Certification for Stainless Steel Tower Bolts \u2013 IS 15833<\/li>\n<li data-section-id=\"mfvf81\" data-start=\"22350\" data-end=\"22392\">BIS Certification for Sliding Door Bolts<\/li>\n<li data-section-id=\"se0zy4\" data-start=\"22393\" data-end=\"22426\">BIS Certification for Fasteners<\/li>\n<li data-section-id=\"1ofvjrb\" data-start=\"22427\" data-end=\"22461\">BIS Certification for Step Bolts<\/li>\n<li data-section-id=\"e1afa0\" data-start=\"22462\" data-end=\"22510\">BIS Certification for Transmission Tower Bolts<\/li>\n<li data-section-id=\"76hlqg\" data-start=\"22511\" data-end=\"22551\">BIS Certification for Structural Bolts<\/li>\n<li data-section-id=\"oaqr2l\" data-start=\"22552\" data-end=\"22573\">BIS Product Testing<\/li>\n<li data-section-id=\"ffrh22\" data-start=\"22574\" data-end=\"22598\">BIS Factory Inspection<\/li>\n<li data-section-id=\"nf47x2\" data-start=\"22599\" data-end=\"22623\">ISI Mark Certification<\/li>\n<li data-section-id=\"se1cch\" data-start=\"22624\" data-end=\"22652\">QCO Compliance Consultancy<\/li>\n<\/ul>\n<hr data-start=\"22654\" data-end=\"22657\" \/>\n<h2 data-section-id=\"vp4xr1\" data-start=\"22659\" data-end=\"22680\">Related Blog Topics<\/h2>\n<ol data-start=\"22682\" data-end=\"23160\">\n<li data-section-id=\"1cyc7vz\" data-start=\"22682\" data-end=\"22742\">BIS Certification for Ferrous Tower Bolts \u2013 IS 204 Part 1<\/li>\n<li data-section-id=\"17njk6h\" data-start=\"22743\" data-end=\"22806\">BIS Certification for Stainless Steel Tower Bolts \u2013 IS 15833<\/li>\n<li data-section-id=\"exw8fj\" data-start=\"22807\" data-end=\"22849\">BIS Certification for Brass Tower Bolts<\/li>\n<li data-section-id=\"11rr4u2\" data-start=\"22850\" data-end=\"22896\">BIS Certification for Aluminium Tower Bolts<\/li>\n<li data-section-id=\"344yc1\" data-start=\"22897\" data-end=\"22944\">BIS Certification for Zinc Alloy Tower Bolts<\/li>\n<li data-section-id=\"5ais26\" data-start=\"22945\" data-end=\"22982\">IS 204 Part 2 Testing Requirements<\/li>\n<li data-section-id=\"82fo7q\" data-start=\"22983\" data-end=\"23023\">Tower Bolt Product Grouping Under BIS<\/li>\n<li data-section-id=\"s043z0\" data-start=\"23024\" data-end=\"23073\">BIS Certification Process for Builder Hardware<\/li>\n<li data-section-id=\"14h7z0l\" data-start=\"23074\" data-end=\"23109\">QCO Requirements for Tower Bolts<\/li>\n<li data-section-id=\"3nxcbi\" data-start=\"23110\" data-end=\"23160\">BIS Certification for Door and Window Hardware<\/li>\n<\/ol>\n<hr data-start=\"23162\" data-end=\"23165\" \/>\n<h2 data-section-id=\"jfwhhx\" data-start=\"23167\" data-end=\"23208\">Need BIS Certification for Tower Bolts?<\/h2>\n<p data-start=\"23210\" data-end=\"23422\">If you manufacture <strong data-start=\"23229\" data-end=\"23262\">non-ferrous metal tower bolts<\/strong> made from brass, aluminium alloy or zinc alloy, compliance with the applicable BIS requirements is important before supplying the product in the Indian market.<\/p>\n<p data-start=\"23424\" data-end=\"23664\">The current BIS Product Manual provides detailed guidance regarding <strong data-start=\"23492\" data-end=\"23598\">product grouping, materials, sizes, samples, testing equipment and inspection and testing arrangements<\/strong> for IS 204 (Part 2):1992.<\/p>\n<p data-start=\"23666\" data-end=\"23717\"><strong data-start=\"23666\" data-end=\"23686\">Qualitance India<\/strong> can assist manufacturers with:<\/p>\n<ul data-start=\"23719\" data-end=\"23966\">\n<li data-section-id=\"1rkmzza\" data-start=\"23719\" data-end=\"23742\">Product applicability<\/li>\n<li data-section-id=\"1327whm\" data-start=\"23743\" data-end=\"23777\">Type and material identification<\/li>\n<li data-section-id=\"1w02i1o\" data-start=\"23778\" data-end=\"23796\">Product grouping<\/li>\n<li data-section-id=\"156gmvn\" data-start=\"23797\" data-end=\"23814\">Sample planning<\/li>\n<li data-section-id=\"1kzgx2c\" data-start=\"23815\" data-end=\"23840\">Laboratory coordination<\/li>\n<li data-section-id=\"1au0k3e\" data-start=\"23841\" data-end=\"23856\">Documentation<\/li>\n<li data-section-id=\"qdbaru\" data-start=\"23857\" data-end=\"23874\">BIS application<\/li>\n<li data-section-id=\"sy9ixn\" data-start=\"23875\" data-end=\"23907\">Factory inspection preparation<\/li>\n<li data-section-id=\"1bxrev1\" data-start=\"23908\" data-end=\"23939\">Quality-control documentation<\/li>\n<li data-section-id=\"7nbtgf\" data-start=\"23940\" data-end=\"23966\">Test report coordination<\/li>\n<\/ul>\n<p data-start=\"23968\" data-end=\"24100\"><strong data-start=\"23968\" data-end=\"23988\">Qualitance India<\/strong><br data-start=\"23988\" data-end=\"23991\" \/><strong data-start=\"23991\" data-end=\"24001\">Phone:<\/strong> +91-9310-615-170<br data-start=\"24018\" data-end=\"24021\" \/><strong data-start=\"24021\" data-end=\"24031\">Email:<\/strong> <a class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-start=\"24032\" data-end=\"24056\">info@qualitanceindia.com<\/a><br data-start=\"24056\" data-end=\"24059\" \/><strong data-start=\"24059\" data-end=\"24071\">Website:<\/strong> <a class=\"decorated-link\" href=\"https:\/\/qualitanceindia.com\/\" target=\"_new\" rel=\"noopener\" data-start=\"24072\" data-end=\"24100\">https:\/\/qualitanceindia.com\/<\/a><\/p>\n<hr data-start=\"24102\" data-end=\"24105\" \/>\n<h2 data-section-id=\"fsb6xx\" data-start=\"24107\" data-end=\"24119\">Conclusion<\/h2>\n<p data-start=\"24121\" data-end=\"24518\"><strong data-start=\"24121\" data-end=\"24180\">IS 204 (Part 2):1992 \u2013 Tower Bolts \u2013 Non-Ferrous Metals<\/strong> provides requirements for tower bolts manufactured from non-ferrous materials such as <strong data-start=\"24267\" data-end=\"24308\">brass, aluminium alloy and zinc alloy<\/strong>. The standard covers both <strong data-start=\"24335\" data-end=\"24370\">barrel and skeleton tower bolts<\/strong> and addresses important characteristics including material, dimensions, tolerances, manufacture and finish.<\/p>\n<p data-start=\"24520\" data-end=\"24657\">BIS currently includes IS 204 (Part 2):1992 in its <strong data-start=\"24571\" data-end=\"24616\">Scheme-I compulsory certification listing<\/strong>.<\/p>\n<p data-start=\"24659\" data-end=\"25009\">For manufacturers with multiple sizes and materials, correctly understanding the <strong data-start=\"24740\" data-end=\"24777\">BIS product grouping requirements<\/strong> is especially important. The current Product Manual specifies grouping based on product type, material and size, with representative smallest and highest sizes tested for the relevant ranges.<\/p>\n<p data-start=\"25011\" data-end=\"25180\">Proper preparation of product specifications, raw-material documents, samples, testing facilities and factory records can make the certification process more systematic.<\/p>\n<p data-start=\"25182\" data-end=\"25444\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"25182\" data-end=\"25202\">Qualitance India<\/strong> provides BIS certification consultancy for <strong data-start=\"25246\" data-end=\"25310\">Tower Bolts \u2013 Non-Ferrous Metals as per IS 204 (Part 2):1992<\/strong>, assisting manufacturers from product assessment and testing coordination through BIS application and factory inspection preparation<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Tower bolts are commonly used as fastening hardware for doors, windows, cabinets, furniture and other applications where a simple sliding locking arrangement is required. When these products are manufactured from non-ferrous metals such as brass, aluminium alloy or zinc alloy, their material quality, dimensions, finish and construction become important factors in determining their performance [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3494,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"slim_seo":{"title":"BIS for Tower Bolts Non-Ferrous Metals - Qualitance India","description":"Complete guide to BIS Certification for Tower Bolts made from Non-Ferrous Metals as per IS 204 (Part 2):1992. Know BIS requirements, testing, documents,"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3493","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3493"}],"version-history":[{"count":2,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3493\/revisions"}],"predecessor-version":[{"id":4494,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3493\/revisions\/4494"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3494"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}