{"id":3661,"date":"2026-09-06T05:44:41","date_gmt":"2026-09-06T05:44:41","guid":{"rendered":"https:\/\/qualitanceindia.com\/?p=3661"},"modified":"2026-10-31T08:12:12","modified_gmt":"2026-10-31T08:12:12","slug":"bis-certification-linear-alkyl-benzene-is-12795","status":"publish","type":"post","link":"https:\/\/qualitanceindia.com\/bis-certification-linear-alkyl-benzene-is-12795\/","title":{"rendered":"BIS Certification Consultancy for Linear Alkyl Benzene | IS 12795:2020"},"content":{"rendered":"<h2>Introduction<\/h2>\n<p class=\"isSelectedEnd\">Linear Alkyl Benzene, commonly known as <strong>LAB<\/strong>, is an important petrochemical intermediate used mainly in the production of surfactants such as Linear Alkylbenzene Sulphonate. It is widely associated with detergent, cleaning-product and industrial chemical manufacturing.<\/p>\n<p class=\"isSelectedEnd\">Because LAB is an important feedstock for downstream chemical processes, its purity and chemical characteristics must be carefully controlled. Parameters such as colour, moisture, specific gravity, Bromine Index, molecular weight, paraffin content, chain-length distribution, sulphonability and LAB content are important indicators of product quality.<\/p>\n<p class=\"isSelectedEnd\">In India, Linear Alkyl Benzene is covered by <strong>IS 12795:2020 \u2013 Linear Alkyl Benzene \u2013 Specification (First Revision)<\/strong>. The product is covered under the BIS <strong>Scheme-I<\/strong> certification framework. The current BIS Product Manual is <strong>PM\/12795\/1, August 2024<\/strong>, incorporating Amendment No. 1. It specifies <strong>1 litre<\/strong> as the sample quantity and states that grouping is not applicable.<\/p>\n<p class=\"isSelectedEnd\">Qualitance India provides end-to-end BIS Certification consultancy for Linear Alkyl Benzene manufacturers, including regulatory assessment, documentation, laboratory coordination, testing support, Quality Assurance Plan preparation, factory inspection preparation and BIS licence assistance.<\/p>\n<h2>What is Linear Alkyl Benzene?<\/h2>\n<p class=\"isSelectedEnd\">Linear Alkyl Benzene is a petrochemical material containing predominantly linear alkylbenzene molecules. It is an important raw material for the manufacture of sulphonated surfactants.<\/p>\n<p class=\"isSelectedEnd\">LAB is commonly used in the production of:<\/p>\n<ul data-spread=\"false\">\n<li>Linear Alkylbenzene Sulphonate<\/li>\n<li>Detergent surfactants<\/li>\n<li>Household cleaning products<\/li>\n<li>Industrial cleaning products<\/li>\n<li>Institutional cleaning formulations<\/li>\n<li>Other downstream surfactant chemicals<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Consistent LAB quality is important because changes in composition can affect downstream sulphonation, processing behaviour and product performance.<\/p>\n<h2>BIS Standard for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The applicable Indian Standard is:<\/p>\n<p class=\"isSelectedEnd\"><strong>IS 12795:2020 \u2013 Linear Alkyl Benzene \u2013 Specification (First Revision)<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The current BIS Product Manual is:<\/p>\n<p class=\"isSelectedEnd\"><strong>PM\/12795\/1 \u2013 August 2024<\/strong><\/p>\n<p class=\"isSelectedEnd\">The Product Manual records:<\/p>\n<ul data-spread=\"false\">\n<li>Standard: IS 12795:2020<\/li>\n<li>Product: Linear Alkyl Benzene<\/li>\n<li>Scheme: Scheme-I<\/li>\n<li>Amendments: 01<\/li>\n<li>Raw-material requirement: No specific requirement<\/li>\n<li>Grouping guidelines: Not applicable<\/li>\n<li>Sample quantity: <strong>1 litre<\/strong><\/li>\n<\/ul>\n<h2>2024 Amendment to IS 12795:2020<\/h2>\n<p class=\"isSelectedEnd\">BIS issued Amendment No. 1 to IS 12795:2020 in 2024.<\/p>\n<p class=\"isSelectedEnd\">BIS&#8217;s implementation guideline states that the amended and unamended standards were allowed to run concurrently until <strong>8 October 2024<\/strong>, and that the amendment was to be implemented by that date.<\/p>\n<p class=\"isSelectedEnd\">The amendment included changes such as:<\/p>\n<ul data-spread=\"false\">\n<li>Replacement of ISO 12937 by <strong>IS 1448 (Part 182)<\/strong> for moisture<\/li>\n<li>Addition of <strong>ASTM D 1492<\/strong> as an alternate method for Bromine Index<\/li>\n<li>Addition of <strong>ASTM D 6045<\/strong> as an alternate method for colour determination<\/li>\n<li>Removal of the ASTM D-86 alternative for the relevant distillation test<\/li>\n<li>Addition of an allowance for use of off-the-shelf highly pure hyamine<\/li>\n<li>Addition of the use of C10-C14 standard LAB for peak identification in chain-length-distribution testing<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The BIS implementation guideline also states that there was <strong>no change in the prescribed product requirement<\/strong> as a result of the amendment; the changes were primarily related to methods and testing provisions.<\/p>\n<h2>Is BIS Certification Mandatory for Linear Alkyl Benzene?<\/h2>\n<p class=\"isSelectedEnd\">Yes. Linear Alkyl Benzene is included in the BIS compulsory certification framework against <strong>IS 12795:2020<\/strong>. BIS&#8217;s current Scheme-I page continues to list Linear Alkyl Benzene along with the applicable Quality Control Order history and the 2026 temporary-suspension notifications.<\/p>\n<p class=\"isSelectedEnd\">The original regulatory framework requires covered LAB to conform to the applicable Indian Standard and bear the Standard Mark under a BIS licence according to Scheme-I.<\/p>\n<h2>Current 2026 Regulatory Position<\/h2>\n<p class=\"isSelectedEnd\">The LAB QCO has undergone a temporary suspension in 2026.<\/p>\n<p class=\"isSelectedEnd\">BIS&#8217;s current compulsory-certification listing records:<\/p>\n<ul data-spread=\"false\">\n<li><strong>S.O. 1655(E), dated 30 March 2026<\/strong> \u2013 Temporary Suspension of Linear Alkyl Benzene (Quality Control) Order, 2022<\/li>\n<li><strong>S.O. 3456(E), dated 25 June 2026<\/strong> \u2013 subsequent temporary-suspension notification<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">At the same time, BIS&#8217;s current upcoming-QCO page lists:<\/p>\n<p class=\"isSelectedEnd\"><strong>Linear Alkyl Benzene \u2014 IS 12795:2020 \u2014 Enforcement date: 30 September 2026.<\/strong><\/p>\n<p class=\"isSelectedEnd\">Therefore, manufacturers should treat September 2026 as an important compliance-preparation period and verify the exact regulatory position immediately before commercial supply because the QCO position is subject to government notifications.<\/p>\n<h2>Why Manufacturers Should Prepare in Advance<\/h2>\n<p class=\"isSelectedEnd\">For a chemical product such as LAB, BIS certification requires more than submitting a laboratory sample. The manufacturer needs suitable analytical facilities, documented processes, trained personnel, calibration, batch traceability and regular testing.<\/p>\n<p class=\"isSelectedEnd\">Manufacturers should therefore prepare:<\/p>\n<ul data-spread=\"false\">\n<li>Product specifications<\/li>\n<li>Laboratory procedures<\/li>\n<li>Analytical equipment<\/li>\n<li>Calibration records<\/li>\n<li>Quality Assurance Plan<\/li>\n<li>Control-unit records<\/li>\n<li>Test records<\/li>\n<li>Raw-material records<\/li>\n<li>Production documentation<\/li>\n<li>Container marking<\/li>\n<li>BIS application documents<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Early preparation can help avoid delays when the mandatory requirement becomes applicable.<\/p>\n<h2>Current BIS Product Manual for LAB<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual contains the practical certification requirements for IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">It specifies:<\/p>\n<p class=\"isSelectedEnd\"><strong>Sample Quantity: 1 litre<\/strong><\/p>\n<p class=\"isSelectedEnd\">and:<\/p>\n<p class=\"isSelectedEnd\"><strong>Grouping Guidelines: Not applicable<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual also states:<\/p>\n<p class=\"isSelectedEnd\"><strong>Raw Material: No specific requirement<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The licence scope is simply:<\/p>\n<p class=\"isSelectedEnd\"><strong>Linear Alkyl Benzene<\/strong>.<\/p>\n<h2>BIS Sample Quantity for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual specifies:<\/p>\n<p class=\"isSelectedEnd\"><strong>1 litre<\/strong><\/p>\n<p class=\"isSelectedEnd\">as the sample quantity for laboratory testing during grant of licence, change in scope and applicable factory-surveillance activities.<\/p>\n<p class=\"isSelectedEnd\">Manufacturers should submit a representative sample that corresponds to the product being offered for certification.<\/p>\n<h2>Product Grouping for LAB<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual clearly states:<\/p>\n<p class=\"isSelectedEnd\"><strong>Grouping Guidelines: Not applicable.<\/strong><\/p>\n<p class=\"isSelectedEnd\">Unlike products where certification scope may be divided by size, grade or capacity, LAB certification is not structured through a conventional grouping table in this Product Manual.<\/p>\n<p class=\"isSelectedEnd\">The manufacturer&#8217;s focus should therefore be on consistent conformity of the product with all applicable requirements of IS 12795:2020.<\/p>\n<h2>Main Quality Requirements for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual identifies the following principal requirements:<\/p>\n<ul data-spread=\"false\">\n<li>Description<\/li>\n<li>Colour<\/li>\n<li>Specific gravity<\/li>\n<li>Moisture<\/li>\n<li>Doctor Test<\/li>\n<li>Flash Point<\/li>\n<li>Bromine Index<\/li>\n<li>Ready Biodegradability of Sulphonate<\/li>\n<li>Distillation<\/li>\n<li>Molecular Weight<\/li>\n<li>Paraffin Content<\/li>\n<li>Sulphonability<\/li>\n<li>Chain-Length Distribution<\/li>\n<li>Refractive Index<\/li>\n<li>Tetralins<\/li>\n<li>LAB Content<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">These tests collectively evaluate the physical, chemical and compositional quality of LAB.<\/p>\n<h2>BIS Testing Requirements for Linear Alkyl Benzene<\/h2>\n<h3>Description<\/h3>\n<p class=\"isSelectedEnd\">The manufacturer must maintain adequate inspection and in-process controls to ensure that LAB meets the specified requirements and should maintain appropriate records.<\/p>\n<h3>Colour<\/h3>\n<p class=\"isSelectedEnd\">Colour may be determined using the specified Saybolt or Lovibond methods.<\/p>\n<p class=\"isSelectedEnd\">Following Amendment No. 1, <strong>ASTM D 6045<\/strong> is also available as an alternate method for colour determination.<\/p>\n<h3>Specific Gravity<\/h3>\n<p class=\"isSelectedEnd\">Specific gravity is determined at:<\/p>\n<p class=\"isSelectedEnd\"><strong>15.5\u00b0C \/ 15.5\u00b0C<\/strong><\/p>\n<p class=\"isSelectedEnd\">The Product Manual references:<\/p>\n<ul data-spread=\"false\">\n<li>IS 1448 (Part 32)<\/li>\n<li>ASTM D 4052<\/li>\n<\/ul>\n<h3>Moisture<\/h3>\n<p class=\"isSelectedEnd\">Moisture is controlled in ppm.<\/p>\n<p class=\"isSelectedEnd\">Available methods include:<\/p>\n<ul data-spread=\"false\">\n<li>IS 286<\/li>\n<li>IS 1448 (Part 182)<\/li>\n<li>ASTM D 6304<\/li>\n<li>UOP 481<\/li>\n<\/ul>\n<h3>Doctor Test<\/h3>\n<p class=\"isSelectedEnd\">The Doctor Test is carried out according to <strong>IS 1448 (Part 19)<\/strong>.<\/p>\n<h3>Flash Point<\/h3>\n<p class=\"isSelectedEnd\">Flash point is determined using the closed-cup method.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual references:<\/p>\n<ul data-spread=\"false\">\n<li>IS 1448 (Part 21)<\/li>\n<li>ASTM D 93<\/li>\n<\/ul>\n<h3>Bromine Index<\/h3>\n<p class=\"isSelectedEnd\">Bromine Index is determined by the applicable standard method.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual references:<\/p>\n<ul data-spread=\"false\">\n<li>UOP 304<\/li>\n<li>ASTM D 2710<\/li>\n<li>ASTM D 1492 following Amendment No. 1<\/li>\n<\/ul>\n<h3>Ready Biodegradability of Sulphonate<\/h3>\n<p class=\"isSelectedEnd\">The relevant LAB is first sulphonated according to the applicable procedure and the resulting sulphonate is tested for ready biodegradability.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual references:<\/p>\n<ul data-spread=\"false\">\n<li>IS 13933<\/li>\n<li>ASTM D 2667<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The test is conducted once in two years or when specified changes occur, such as change in type, composition, raw-material source or process.<\/p>\n<h3>Distillation<\/h3>\n<p class=\"isSelectedEnd\">Distillation performance is assessed using the applicable method in:<\/p>\n<p class=\"isSelectedEnd\"><strong>IS 1448 (Part 18)<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual identifies this as a routine test to be conducted once a week.<\/p>\n<h3>Molecular Weight<\/h3>\n<p class=\"isSelectedEnd\">Molecular weight is determined using:<\/p>\n<ul data-spread=\"false\">\n<li>Annex B of IS 12795<\/li>\n<li>UOP 698-12<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">It is identified as a routine test for each control unit.<\/p>\n<h3>Paraffin Content<\/h3>\n<p class=\"isSelectedEnd\">Paraffin content is determined using Annex C of IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">The test is identified as a routine test for each control unit.<\/p>\n<h3>Sulphonability<\/h3>\n<p class=\"isSelectedEnd\">Sulphonability is determined using Annex D of IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual specifies a routine testing frequency of once a week.<\/p>\n<h3>Chain-Length Distribution<\/h3>\n<p class=\"isSelectedEnd\">Chain-length distribution is determined using:<\/p>\n<ul data-spread=\"false\">\n<li>Annex E of IS 12795<\/li>\n<li>UOP 698-12<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The 2024 amendment also specifies that standard linear alkylbenzene of <strong>C10 to C14<\/strong> shall be used for peak identification.<\/p>\n<h3>Refractive Index<\/h3>\n<p class=\"isSelectedEnd\">Refractive index is determined according to:<\/p>\n<ul data-spread=\"false\">\n<li>Annex G of IS 12795<\/li>\n<li>IS 1448 (Part 158)<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The Product Manual specifies a once-a-week routine frequency.<\/p>\n<h3>Tetralins<\/h3>\n<p class=\"isSelectedEnd\">Tetralins are determined according to Annex H of IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">The specified routine frequency is once a month.<\/p>\n<h3>LAB Content<\/h3>\n<p class=\"isSelectedEnd\">LAB content is determined according to <strong>UOP 698-12<\/strong> and is identified as a routine test for each control unit.<\/p>\n<h2>Routine Testing Frequency<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual provides the following control framework:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Parameter<\/th>\n<th>Equipment Category<\/th>\n<th>Frequency<\/th>\n<\/tr>\n<tr>\n<td>Description<\/td>\n<td>R<\/td>\n<td>Adequate inspection and in-process control<\/td>\n<\/tr>\n<tr>\n<td>Colour<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Specific gravity<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Moisture<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Doctor Test<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Flash Point<\/td>\n<td>R<\/td>\n<td>Once a week<\/td>\n<\/tr>\n<tr>\n<td>Bromine Index<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Ready biodegradability of sulphonate<\/td>\n<td>S<\/td>\n<td>Once in 2 years or specified change<\/td>\n<\/tr>\n<tr>\n<td>Distillation<\/td>\n<td>R<\/td>\n<td>Once a week<\/td>\n<\/tr>\n<tr>\n<td>Molecular weight<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Paraffin<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Sulphonability<\/td>\n<td>R<\/td>\n<td>Once a week<\/td>\n<\/tr>\n<tr>\n<td>Chain-length distribution<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<tr>\n<td>Refractive index<\/td>\n<td>R<\/td>\n<td>Once a week<\/td>\n<\/tr>\n<tr>\n<td>Tetralins<\/td>\n<td>R<\/td>\n<td>Once a month<\/td>\n<\/tr>\n<tr>\n<td>LAB content<\/td>\n<td>R<\/td>\n<td>Each control unit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"isSelectedEnd\">These frequencies are based on the current August 2024 BIS Product Manual.<\/p>\n<h2>Control Unit for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The Product Manual recommends:<\/p>\n<p class=\"isSelectedEnd\"><strong>The entire quantity of material produced continuously at a time in each reaction vessel constitutes one control unit.<\/strong><\/p>\n<p class=\"isSelectedEnd\">This definition should be incorporated into the manufacturer&#8217;s production records and Quality Assurance Plan.<\/p>\n<h2>Quality Assurance Plan<\/h2>\n<p class=\"isSelectedEnd\">The manufacturer should establish a Quality Assurance Plan covering regular testing and in-process control to ensure that Standard Mark-bearing product conforms to IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">The plan should define:<\/p>\n<ul data-spread=\"false\">\n<li>Control unit<\/li>\n<li>Test parameters<\/li>\n<li>Test methods<\/li>\n<li>Sampling quantity<\/li>\n<li>Testing frequency<\/li>\n<li>Acceptance criteria<\/li>\n<li>In-process controls<\/li>\n<li>Record-keeping<\/li>\n<li>Calibration<\/li>\n<li>Corrective action<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The Product Manual requires the Quality Assurance Plan to be submitted to the BIS Branch Office for information.<\/p>\n<h2>In-House Testing Requirements<\/h2>\n<p class=\"isSelectedEnd\">The Product Manual classifies testing facilities broadly as:<\/p>\n<p class=\"isSelectedEnd\"><strong>R \u2013 Test equipment required<\/strong><\/p>\n<p class=\"isSelectedEnd\">and<\/p>\n<p class=\"isSelectedEnd\"><strong>S \u2013 Subcontracting permitted<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">For permitted subcontracted tests, the manufacturer may use:<\/p>\n<ul data-spread=\"false\">\n<li>BIS-recognized\/empanelled laboratories<\/li>\n<li>Laboratories having valid NABL accreditation as per IS\/ISO\/IEC 17025<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Testing reports should be available for BIS inspection.<\/p>\n<h2>MSME Testing Provisions<\/h2>\n<p class=\"isSelectedEnd\">For eligible MSME manufacturers, maintaining an in-house facility for routine tests marked \u201cR\u201d is optional under the Product Manual.<\/p>\n<p class=\"isSelectedEnd\">Such manufacturers may use:<\/p>\n<ul data-spread=\"false\">\n<li>Common cluster testing facilities<\/li>\n<li>Shared testing facilities<\/li>\n<li>BIS-recognized\/empanelled laboratories<\/li>\n<li>Valid NABL-accredited laboratories<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">subject to the applicable BIS provisions.<\/p>\n<h2>Large-Scale Manufacturer Laboratory<\/h2>\n<p class=\"isSelectedEnd\">Large-scale manufacturers are expected to have suitably equipped and staffed laboratory arrangements for the required routine tests.<\/p>\n<p class=\"isSelectedEnd\">The Product Manual also provides for sharing of testing facilities where applicable under BIS guidelines.<\/p>\n<h2>Testing Equipment Required for LAB<\/h2>\n<p class=\"isSelectedEnd\">The Product Manual provides an indicative test-equipment list.<\/p>\n<h3>Colour Testing<\/h3>\n<p class=\"isSelectedEnd\">Depending on the selected method:<\/p>\n<ul data-spread=\"false\">\n<li>Saybolt Chromometer<\/li>\n<li>Lovibond Tintometer<\/li>\n<li>Colour standards<\/li>\n<li>Reference slides<\/li>\n<li>Spectrophotometer<\/li>\n<li>Tristimulus filter colorimeter<\/li>\n<\/ul>\n<h3>Specific Gravity<\/h3>\n<p class=\"isSelectedEnd\">Possible equipment includes:<\/p>\n<ul data-spread=\"false\">\n<li>Digital density analyser<\/li>\n<li>Constant-temperature bath<\/li>\n<li>Pyknometer<\/li>\n<li>Balance<\/li>\n<li>Temperature sensing device<\/li>\n<\/ul>\n<h3>Moisture<\/h3>\n<p class=\"isSelectedEnd\">Potential facilities include:<\/p>\n<ul data-spread=\"false\">\n<li>Karl Fischer titrator<\/li>\n<li>Karl Fischer reagents<\/li>\n<li>Balance<\/li>\n<li>Oven<\/li>\n<li>Cooling bath<\/li>\n<li>Thermometer<\/li>\n<\/ul>\n<h3>Doctor Test<\/h3>\n<p class=\"isSelectedEnd\">Suitable glassware and the specified reagents are required according to IS 1448 (Part 19).<\/p>\n<h3>Flash Point<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual identifies:<\/p>\n<ul data-spread=\"false\">\n<li>Pensky-Martens closed-cup flash-point apparatus<\/li>\n<li>Temperature indicator<\/li>\n<li>Barometer<\/li>\n<li>Heating bath or oven<\/li>\n<\/ul>\n<h3>Bromine Index<\/h3>\n<p class=\"isSelectedEnd\">Depending on the method, equipment may include electrometric titration apparatus, titration vessels and appropriate reference\/reagent systems.<\/p>\n<h3>Molecular Weight and Composition<\/h3>\n<p class=\"isSelectedEnd\">Gas chromatography is required for important analytical determinations, including molecular weight and compositional parameters.<\/p>\n<p class=\"isSelectedEnd\">Typical facilities include:<\/p>\n<ul data-spread=\"false\">\n<li>Gas chromatograph<\/li>\n<li>Appropriate chromatographic column<\/li>\n<li>Flame ionization detector<\/li>\n<li>Data-processing system<\/li>\n<li>Carrier gases<\/li>\n<li>Reference standards<\/li>\n<\/ul>\n<h3>Tetralins<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual identifies high-performance liquid chromatography facilities for tetralins determination.<\/p>\n<h2>Importance of Gas Chromatography<\/h2>\n<p class=\"isSelectedEnd\">Gas chromatography is especially important in LAB certification because several compositional parameters depend on chromatographic analysis.<\/p>\n<p class=\"isSelectedEnd\">These can include:<\/p>\n<ul data-spread=\"false\">\n<li>Molecular weight<\/li>\n<li>Paraffin content<\/li>\n<li>Chain-length distribution<\/li>\n<li>LAB content<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Therefore, manufacturers should assess their GC capability before applying for certification.<\/p>\n<h2>Importance of Moisture Testing<\/h2>\n<p class=\"isSelectedEnd\">Moisture is controlled in ppm and can affect the product&#8217;s processing and downstream performance.<\/p>\n<p class=\"isSelectedEnd\">The current Product Manual allows several methods, including IS 1448 (Part 182), which was incorporated into the amendment replacing ISO 12937.<\/p>\n<h2>BIS Testing Laboratory for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The BIS Laboratory Information Management System currently contains laboratory records for <strong>IS 12795:2020 \u2013 Linear Alkyl Benzene \u2013 Specification (First Revision)<\/strong>. BIS Central Laboratory is among the listed laboratory records.<\/p>\n<p class=\"isSelectedEnd\">The current LIMS record also shows that laboratories may have <strong>specific exclusions from their displayed scope<\/strong>, including some major LAB analytical parameters.<\/p>\n<p class=\"isSelectedEnd\">Therefore, manufacturers should not select a laboratory based only on the standard number. The laboratory&#8217;s exact active testing scope should be checked against every parameter required for the proposed certification.<\/p>\n<h2>BIS Testing Cost for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">Current BIS LIMS listings do not provide one universal consolidated testing charge covering every IS 12795 parameter.<\/p>\n<p class=\"isSelectedEnd\">The displayed laboratory records show exclusions for several specialized tests, including:<\/p>\n<ul data-spread=\"false\">\n<li>Molecular weight<\/li>\n<li>Paraffin<\/li>\n<li>Sulphonability<\/li>\n<li>Chain-length distribution<\/li>\n<li>Refractive index<\/li>\n<li>Tetralins<\/li>\n<li>LAB content<\/li>\n<li>Ready biodegradability of sulphonate<\/li>\n<li>Bromine Index<\/li>\n<li>Doctor Test<\/li>\n<li>Colour<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Therefore, a manufacturer should obtain a laboratory quotation based on the <strong>exact test scope<\/strong>, rather than relying on a generic LAB testing price.<\/p>\n<h2>Total BIS Certification Cost for Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">The overall project cost can include:<\/p>\n<ul data-spread=\"false\">\n<li>BIS application-related charges<\/li>\n<li>Certification-related fees<\/li>\n<li>Laboratory testing<\/li>\n<li>External laboratory testing<\/li>\n<li>Sample preparation<\/li>\n<li>Laboratory equipment<\/li>\n<li>Calibration<\/li>\n<li>Quality-system preparation<\/li>\n<li>Factory inspection<\/li>\n<li>Corrective action and re-testing<\/li>\n<li>Consultancy charges<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The final amount depends on the manufacturer&#8217;s testing capability and proposed certification arrangement.<\/p>\n<h2>Documents Required for BIS Certification<\/h2>\n<p class=\"isSelectedEnd\">Typical documents may include:<\/p>\n<ul data-spread=\"false\">\n<li>Company registration documents<\/li>\n<li>Factory address proof<\/li>\n<li>Factory layout<\/li>\n<li>Manufacturing process flow chart<\/li>\n<li>Reaction-vessel details<\/li>\n<li>Production capacity<\/li>\n<li>Machinery list<\/li>\n<li>Product specification<\/li>\n<li>Raw-material information<\/li>\n<li>Process-control details<\/li>\n<li>Laboratory equipment list<\/li>\n<li>Calibration certificates<\/li>\n<li>Testing procedures<\/li>\n<li>Test records<\/li>\n<li>Quality Assurance Plan<\/li>\n<li>Production records<\/li>\n<li>Batch\/control-unit records<\/li>\n<li>Technical personnel details<\/li>\n<li>GST\/business documents<\/li>\n<li>Trademark information<\/li>\n<li>Authorization documents<\/li>\n<li>Container\/packing details<\/li>\n<li>Proposed BIS marking<\/li>\n<li>BIS declarations and undertakings<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The final document set should be prepared according to the manufacturer&#8217;s actual factory and application scope.<\/p>\n<h2>Manufacturing Process of Linear Alkyl Benzene<\/h2>\n<p class=\"isSelectedEnd\">A typical LAB manufacturing process can involve:<\/p>\n<h3>1. Raw Material Preparation<\/h3>\n<p class=\"isSelectedEnd\">Suitable hydrocarbon feedstocks are received, tested and stored.<\/p>\n<h3>2. Feed Purification<\/h3>\n<p class=\"isSelectedEnd\">Unwanted contaminants are reduced or controlled according to the production technology.<\/p>\n<h3>3. Alkylation<\/h3>\n<p class=\"isSelectedEnd\">Benzene and linear olefin feed are reacted in a controlled process using an appropriate catalyst system.<\/p>\n<h3>4. Separation<\/h3>\n<p class=\"isSelectedEnd\">The reaction mixture is separated into LAB, unreacted feed and other fractions.<\/p>\n<h3>5. Purification<\/h3>\n<p class=\"isSelectedEnd\">The product is further purified to achieve the required quality.<\/p>\n<h3>6. Fractionation<\/h3>\n<p class=\"isSelectedEnd\">Off-spec and unwanted components are separated.<\/p>\n<h3>7. Product Storage<\/h3>\n<p class=\"isSelectedEnd\">Finished LAB is stored in suitable tanks with identification and traceability.<\/p>\n<h3>8. Laboratory Testing<\/h3>\n<p class=\"isSelectedEnd\">Samples are tested against the applicable IS 12795 requirements.<\/p>\n<h3>9. Dispatch<\/h3>\n<p class=\"isSelectedEnd\">Only conforming production covered by the applicable BIS requirements should be released for the relevant market.<\/p>\n<h2>Factory Inspection for LAB BIS Certification<\/h2>\n<p class=\"isSelectedEnd\">During factory inspection, the manufacturing unit may be assessed for:<\/p>\n<h3>Process Facilities<\/h3>\n<p class=\"isSelectedEnd\">Actual production equipment should correspond with the submitted process information.<\/p>\n<h3>Reaction Vessel Controls<\/h3>\n<p class=\"isSelectedEnd\">Production quantity and control-unit records should be traceable.<\/p>\n<h3>Laboratory Facilities<\/h3>\n<p class=\"isSelectedEnd\">Required routine testing equipment should be available and functional.<\/p>\n<h3>Calibration<\/h3>\n<p class=\"isSelectedEnd\">Relevant measuring and test equipment should have suitable calibration or verification records.<\/p>\n<h3>Quality Records<\/h3>\n<p class=\"isSelectedEnd\">The manufacturer should maintain:<\/p>\n<ul data-spread=\"false\">\n<li>Raw-material records<\/li>\n<li>Production records<\/li>\n<li>Test reports<\/li>\n<li>Control-unit records<\/li>\n<li>Calibration records<\/li>\n<li>Rejection records<\/li>\n<li>Corrective-action records<\/li>\n<li>Dispatch records<\/li>\n<\/ul>\n<h2>Product Marking Requirements<\/h2>\n<p class=\"isSelectedEnd\">The current Product Manual states that the <strong>Standard Mark shall be incorporated legibly and indelibly on each container of Linear Alkyl Benzene<\/strong>, provided that the material so marked conforms to the specification.<\/p>\n<p class=\"isSelectedEnd\">The container is also required to carry:<\/p>\n<p class=\"isSelectedEnd\"><strong>\u201cFor BIS certification details please visit <\/strong><a href=\"http:\/\/www.bis.gov.in\u201d\"><strong>www.bis.gov.in\u201d<\/strong><\/a>.<\/p>\n<p class=\"isSelectedEnd\">Only conforming production covered by the licence should carry the Standard Mark.<\/p>\n<h2>Maintaining BIS Compliance After Certification<\/h2>\n<p class=\"isSelectedEnd\">Obtaining the BIS licence is not the end of the compliance process.<\/p>\n<p class=\"isSelectedEnd\">The manufacturer must continue to:<\/p>\n<ul data-spread=\"false\">\n<li>Conduct routine testing<\/li>\n<li>Maintain control-unit records<\/li>\n<li>Maintain calibration<\/li>\n<li>Control product quality<\/li>\n<li>Maintain laboratory records<\/li>\n<li>Maintain traceability<\/li>\n<li>Follow approved marking procedures<\/li>\n<li>Submit required information to BIS when applicable<\/li>\n<li>Cooperate with surveillance activities<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Continuous compliance is essential for maintaining the validity and proper operation of the certification.<\/p>\n<h2>Common Reasons for BIS Certification Delays<\/h2>\n<p class=\"isSelectedEnd\">LAB manufacturers may face delays because of:<\/p>\n<ul data-spread=\"false\">\n<li>Incomplete application documents<\/li>\n<li>Inadequate laboratory capability<\/li>\n<li>Lack of suitable GC facilities<\/li>\n<li>Incorrect test methods<\/li>\n<li>Missing calibration records<\/li>\n<li>Poor batch traceability<\/li>\n<li>Moisture non-conformity<\/li>\n<li>Bromine Index failure<\/li>\n<li>Molecular-weight variation<\/li>\n<li>Paraffin-content variation<\/li>\n<li>Chain-length-distribution failure<\/li>\n<li>LAB-content failure<\/li>\n<li>Sulphonability failure<\/li>\n<li>Incomplete Quality Assurance Plan<\/li>\n<li>Factory inspection observations<\/li>\n<li>Incorrect container marking<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">A laboratory and factory readiness assessment before application can significantly reduce these risks.<\/p>\n<h2>Who Needs BIS Certification for Linear Alkyl Benzene?<\/h2>\n<p class=\"isSelectedEnd\">The requirement is relevant to manufacturers and other covered businesses supplying Linear Alkyl Benzene into the Indian market under the applicable QCO framework.<\/p>\n<p class=\"isSelectedEnd\">The product is particularly relevant to:<\/p>\n<ul data-spread=\"false\">\n<li>Petrochemical manufacturers<\/li>\n<li>LAB producers<\/li>\n<li>Chemical manufacturers<\/li>\n<li>Industrial chemical suppliers<\/li>\n<li>Bulk chemical suppliers<\/li>\n<li>Downstream detergent-raw-material manufacturers<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Importers and buyers should also verify that the supplier&#8217;s regulatory status matches the current QCO requirements.<\/p>\n<h2>Benefits of BIS Certification for LAB Manufacturers<\/h2>\n<p class=\"isSelectedEnd\">BIS certification can help manufacturers demonstrate conformity with the applicable Indian Standard and regulatory requirements.<\/p>\n<p class=\"isSelectedEnd\">Benefits include:<\/p>\n<ul data-spread=\"false\">\n<li>Regulatory compliance<\/li>\n<li>Authorization to use the BIS Standard Mark<\/li>\n<li>Improved customer confidence<\/li>\n<li>Better product consistency<\/li>\n<li>Stronger quality-control systems<\/li>\n<li>Better batch traceability<\/li>\n<li>Improved laboratory discipline<\/li>\n<li>Enhanced market credibility<\/li>\n<li>Better acceptance by industrial customers<\/li>\n<\/ul>\n<h2>BIS Certification for Linear Alkyl Benzene \u2013 Quick Process<\/h2>\n<p class=\"isSelectedEnd\"><strong>Regulatory Assessment \u2192 Factory Assessment \u2192 Product Review \u2192 Documentation \u2192 Laboratory Preparation \u2192 BIS Application \u2192 Sample Testing \u2192 Factory Inspection \u2192 Compliance Closure \u2192 BIS Licence \u2192 Standard Marking<\/strong><\/p>\n<h2>Why Choose Qualitance India?<\/h2>\n<p class=\"isSelectedEnd\">Qualitance India provides professional BIS Certification consultancy for Linear Alkyl Benzene manufacturers.<\/p>\n<p class=\"isSelectedEnd\">Our support can include:<\/p>\n<ul data-spread=\"false\">\n<li>Regulatory applicability assessment<\/li>\n<li>IS 12795 compliance review<\/li>\n<li>Product-document review<\/li>\n<li>BIS application preparation<\/li>\n<li>Product testing coordination<\/li>\n<li>Laboratory selection support<\/li>\n<li>Laboratory readiness assessment<\/li>\n<li>Quality Assurance Plan preparation<\/li>\n<li>Testing-equipment guidance<\/li>\n<li>Sample planning<\/li>\n<li>Factory inspection preparation<\/li>\n<li>Technical compliance support<\/li>\n<li>Non-conformity response support<\/li>\n<li>BIS licence follow-up<\/li>\n<li>Post-certification compliance assistance<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Our goal is to help manufacturers organize their technical, testing and documentation requirements for BIS certification.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>1. What is BIS Certification for Linear Alkyl Benzene?<\/h3>\n<p class=\"isSelectedEnd\">It is the BIS conformity-assessment process through which a manufacturer demonstrates that Linear Alkyl Benzene conforms to IS 12795:2020 and obtains authorization to use the Standard Mark within the approved certification framework.<\/p>\n<h3>2. Which standard applies to Linear Alkyl Benzene?<\/h3>\n<p class=\"isSelectedEnd\">The applicable standard is <strong>IS 12795:2020 \u2013 Linear Alkyl Benzene \u2013 Specification (First Revision)<\/strong>.<\/p>\n<h3>3. Is BIS certification mandatory for LAB?<\/h3>\n<p class=\"isSelectedEnd\">Linear Alkyl Benzene is included in the BIS compulsory Scheme-I framework. The current BIS page also records the 2026 temporary-suspension notifications associated with the LAB QCO.<\/p>\n<h3>4. What is the current BIS Product Manual?<\/h3>\n<p class=\"isSelectedEnd\">The current revised Product Manual is <strong>PM\/12795\/1, August 2024<\/strong>.<\/p>\n<h3>5. How much sample is required?<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual specifies <strong>1 litre<\/strong>.<\/p>\n<h3>6. Is grouping applicable?<\/h3>\n<p class=\"isSelectedEnd\">No. The Product Manual states <strong>Grouping Guidelines: Not applicable<\/strong>.<\/p>\n<h3>7. Is there a specific raw-material sampling requirement?<\/h3>\n<p class=\"isSelectedEnd\">No. The Product Manual states <strong>No specific requirement<\/strong> under the raw-material section.<\/p>\n<h3>8. What are the main LAB tests?<\/h3>\n<p class=\"isSelectedEnd\">The principal requirements include colour, specific gravity, moisture, Doctor Test, flash point, Bromine Index, biodegradability of sulphonate, distillation, molecular weight, paraffin, sulphonability, chain-length distribution, refractive index, tetralins and LAB content.<\/p>\n<h3>9. Is moisture testing required?<\/h3>\n<p class=\"isSelectedEnd\">Yes. Moisture is a specified quality parameter and can be tested using the permitted methods including IS 1448 (Part 182).<\/p>\n<h3>10. Is gas chromatography required?<\/h3>\n<p class=\"isSelectedEnd\">Gas chromatography is identified in the Product Manual for important analytical determinations such as molecular weight, paraffin, chain-length distribution and LAB content.<\/p>\n<h3>11. Is HPLC required?<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual identifies HPLC facilities for determination of tetralins.<\/p>\n<h3>12. How often is colour tested?<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual specifies one sample for each control unit.<\/p>\n<h3>13. How often is flash point tested?<\/h3>\n<p class=\"isSelectedEnd\">The specified routine frequency is <strong>once a week<\/strong>.<\/p>\n<h3>14. How often is biodegradability tested?<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual specifies once every two years or when specified changes occur, including changes in type, composition, raw-material source or process.<\/p>\n<h3>15. What is the control unit for LAB?<\/h3>\n<p class=\"isSelectedEnd\">The recommended control unit is the entire quantity of material produced continuously at a time in each reaction vessel.<\/p>\n<h3>16. Is an in-house laboratory required?<\/h3>\n<p class=\"isSelectedEnd\">Routine \u201cR\u201d tests require appropriate testing arrangements, while specific \u201cS\u201d tests may be subcontracted under the permitted provisions.<\/p>\n<h3>17. Can MSMEs use outside laboratories?<\/h3>\n<p class=\"isSelectedEnd\">Yes, where permitted under the Product Manual, eligible MSMEs may use common, shared, BIS-recognized or valid NABL-accredited laboratory facilities.<\/p>\n<h3>18. Can large manufacturers use shared laboratories?<\/h3>\n<p class=\"isSelectedEnd\">The Product Manual provides for sharing of testing facilities under applicable BIS guidelines.<\/p>\n<h3>19. What is the current LAB testing cost?<\/h3>\n<p class=\"isSelectedEnd\">There is no single universal price because current BIS LIMS records show laboratories with different scopes and exclusions. Manufacturers should obtain a quotation based on the exact required test parameters.<\/p>\n<h3>20. What important amendment was made in 2024?<\/h3>\n<p class=\"isSelectedEnd\">Amendment No. 1 changed or added certain test methods, including IS 1448 (Part 182) for moisture, ASTM D 1492 for Bromine Index and ASTM D 6045 for colour.<\/p>\n<h3>21. Was the product requirement itself changed by the amendment?<\/h3>\n<p class=\"isSelectedEnd\">BIS&#8217;s implementation guideline states that there was no change in the prescribed requirement; the amendment primarily introduced or changed test methods and related technical provisions.<\/p>\n<h3>22. What is the current 2026 regulatory position?<\/h3>\n<p class=\"isSelectedEnd\">BIS currently records temporary-suspension notifications for the LAB QCO and separately lists <strong>30 September 2026<\/strong> as the enforcement date on its upcoming-QCO page.<\/p>\n<h3>23. Should manufacturers wait until the enforcement date to apply?<\/h3>\n<p class=\"isSelectedEnd\">No. Manufacturers planning continued Indian-market supply should use the available preparation period for documentation, laboratory readiness, testing and factory compliance.<\/p>\n<h3>24. What marking is required?<\/h3>\n<p class=\"isSelectedEnd\">The Standard Mark must be incorporated legibly and indelibly on each conforming LAB container, and the container must also carry the BIS website statement specified in the Product Manual.<\/p>\n<h3>25. What documents are required?<\/h3>\n<p class=\"isSelectedEnd\">Typical documents include factory details, manufacturing process, production capacity, laboratory details, calibration records, test procedures, Quality Assurance Plan, quality records and company\/legal documents.<\/p>\n<h3>26. What happens if LAB fails a test?<\/h3>\n<p class=\"isSelectedEnd\">The manufacturer should identify the root cause, implement corrective action and follow the applicable BIS retesting\/compliance procedure before representing the affected production as conforming.<\/p>\n<h3>27. Is factory inspection required?<\/h3>\n<p class=\"isSelectedEnd\">Factory assessment\/inspection is an important part of the BIS licensing process, where manufacturing, quality-control and testing capabilities are evaluated.<\/p>\n<h3>28. Can Qualitance India coordinate LAB testing?<\/h3>\n<p class=\"isSelectedEnd\">Yes. Qualitance India can assist with sample planning, laboratory selection and product testing coordination.<\/p>\n<h3>29. Can Qualitance India prepare the Quality Assurance Plan?<\/h3>\n<p class=\"isSelectedEnd\">Yes. Qualitance India can assist in preparing a Quality Assurance Plan covering control units, test frequencies, sampling and required quality controls.<\/p>\n<h3>30. Can Qualitance India provide complete BIS consultancy for LAB?<\/h3>\n<p class=\"isSelectedEnd\">Yes. Qualitance India provides end-to-end support covering regulatory assessment, documentation, laboratory coordination, testing, factory inspection preparation and BIS licence support.<\/p>\n<h2>Frequently Searched Topics<\/h2>\n<ul data-spread=\"false\">\n<li>BIS Certification for Linear Alkyl Benzene<\/li>\n<li>IS 12795:2020 BIS Certification<\/li>\n<li>BIS Licence for Linear Alkyl Benzene<\/li>\n<li>LAB BIS Certification<\/li>\n<li>Linear Alkyl Benzene Testing<\/li>\n<li>IS 12795 Testing<\/li>\n<li>LAB Testing Laboratory<\/li>\n<li>BIS Testing for Linear Alkyl Benzene<\/li>\n<li>Linear Alkyl Benzene QCO<\/li>\n<li>Linear Alkyl Benzene Quality Control Order<\/li>\n<li>LAB Certification Consultant<\/li>\n<li>BIS Licence for Chemical Manufacturer<\/li>\n<li>LAB Chemical Testing<\/li>\n<li>LAB Content Test<\/li>\n<li>Paraffin Content Test<\/li>\n<li>Molecular Weight Test for LAB<\/li>\n<li>Chain-Length Distribution Test<\/li>\n<li>Sulphonability Test<\/li>\n<li>Bromine Index Test<\/li>\n<li>Refractive Index Test for LAB<\/li>\n<li>Tetralins Test<\/li>\n<li>BIS Certification for Petrochemical Products<\/li>\n<li>Linear Alkyl Benzene Certification in India<\/li>\n<\/ul>\n<h2>Related BIS Certification Services<\/h2>\n<p class=\"isSelectedEnd\">Qualitance India also provides BIS consultancy for manufacturers of:<\/p>\n<p class=\"isSelectedEnd\"><strong>Chemicals | Petrochemicals | Aluminium Products | Steel Products | Construction Materials | Electrical Products | Textiles | Engineering Products | Fire-Safety Products | Consumer Products<\/strong><\/p>\n<p class=\"isSelectedEnd\">Our services include:<\/p>\n<p class=\"isSelectedEnd\"><strong>BIS Certification Consultancy | BIS Licence | ISI Mark Certification | Product Testing | Documentation Support | Factory Inspection Assistance | Quality Plan Preparation | Technical Compliance Support | Scope Extension | Licence Renewal | End-to-End BIS Support<\/strong><\/p>\n<h2>Contact Qualitance India<\/h2>\n<p class=\"isSelectedEnd\"><strong>Qualitance India<\/strong><br \/>\nBIS Certification Consultancy for Manufacturers<\/p>\n<p class=\"isSelectedEnd\"><strong>Phone:<\/strong> +91 93106 15170<br \/>\n<strong>Email:<\/strong> <a href=\"mailto:info@qualitanceindia.com\">info@qualitanceindia.com<\/a><br \/>\n<strong>Website:<\/strong> <a href=\"https:\/\/qualitanceindia.com\/\" data-rich-text-autolink=\"\">https:\/\/qualitanceindia.com\/<\/a><\/p>\n<p class=\"isSelectedEnd\">Manufacturers of Linear Alkyl Benzene can contact Qualitance India for assistance with <strong>IS 12795:2020 BIS Certification<\/strong>, laboratory testing, Quality Assurance Plan preparation, documentation, factory inspection preparation and BIS licence support.<\/p>\n<h2>Conclusion<\/h2>\n<p class=\"isSelectedEnd\">Linear Alkyl Benzene is a critical petrochemical intermediate used in the manufacture of surfactants and detergent-related products. Maintaining consistent LAB quality requires control over multiple physical and chemical parameters, including moisture, colour, Bromine Index, molecular weight, paraffin content, chain-length distribution, sulphonability, tetralins and LAB content.<\/p>\n<p class=\"isSelectedEnd\">The current BIS Product Manual <strong>PM\/12795\/1, August 2024<\/strong> provides the certification framework under Scheme-I, specifies a <strong>1-litre sample<\/strong>, states that grouping is not applicable and establishes detailed requirements for routine testing, laboratory facilities, control units and product marking.<\/p>\n<p class=\"isSelectedEnd\">BIS Amendment No. 1 introduced important changes to testing methods, including the use of <strong>IS 1448 (Part 182)<\/strong> for moisture and additional alternative methods for Bromine Index and colour.<\/p>\n<p class=\"isSelectedEnd\">The 2026 regulatory position requires particular attention because BIS currently records temporary-suspension notifications for the LAB QCO while its upcoming-QCO page lists <strong>30 September 2026<\/strong> as the enforcement date for IS 12795:2020.<\/p>\n<p class=\"isSelectedEnd\">Manufacturers should therefore prepare their laboratory, documentation, testing, quality-control and factory systems in advance and verify the latest government notification before commercial supply.<\/p>\n<p>With professional assistance from <strong>Qualitance India<\/strong>, Linear Alkyl Benzene manufacturers can receive end-to-end support for regulatory assessment, documentation, laboratory testing coordination, Quality Assurance Plan preparation, factory inspection readiness and BIS licence processing.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Linear Alkyl Benzene, commonly known as LAB, is an important petrochemical intermediate used mainly in the production of surfactants such as Linear Alkylbenzene Sulphonate. It is widely associated with detergent, cleaning-product and industrial chemical manufacturing. Because LAB is an important feedstock for downstream chemical processes, its purity and chemical characteristics must be carefully controlled. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3662,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"slim_seo":{"title":"BIS Certification for Linear Alkyl Benzene","description":"Get BIS Certification for Linear Alkyl Benzene under IS 12795:2020. Qualitance India provides BIS application, testing, documentation, factory inspection\u2026"},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3661","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/comments?post=3661"}],"version-history":[{"count":1,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3661\/revisions"}],"predecessor-version":[{"id":3663,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/posts\/3661\/revisions\/3663"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media\/3662"}],"wp:attachment":[{"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/media?parent=3661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/categories?post=3661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualitanceindia.com\/wp-json\/wp\/v2\/tags?post=3661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}