Quick answer: Under the Gas Cylinders Rules 2016, no gas cylinder can be filled unless it has passed periodic examination and a hydrostatic (or hydrostatic stretch) test within the interval set for that cylinder. LPG cylinders are first re-tested 10 years after manufacture and then every 5 years. Testing can only be done at a cylinder testing station approved by PESO (the Chief Controller of Explosives).

Every gas cylinder in use in India – LPG, CNG, oxygen, nitrogen, CO₂, acetylene or industrial and toxic gases – must be examined and tested at regular intervals. This guide explains the periodic testing rules under the Gas Cylinders Rules 2016 and how to get PESO approval to set up a gas cylinder testing station.

PESO approvals for LPG, CNG and gas cylinders

Why periodic testing is mandatory

Rule 35 of the Gas Cylinders Rules 2016 says that no person shall fill any cylinder with compressed gas unless it has been examined and passed the hydrostatic test or hydrostatic stretch test, and the other tests in Schedule IV, within the period specified. A cylinder that is due for testing cannot be filled, and filling plants set such cylinders aside and send them for testing.

How often cylinders must be tested

LPG cylinder re-test schedule and testing station steps
LPG cylinder re-test schedule and what happens at the testing station
  • LPG cylinders: first re-test 10 years from the date of manufacture, then every 5 years.
  • Other gas cylinders: the interval depends on the gas and the type of cylinder, as set out in Schedule IV of the Gas Cylinders Rules 2016. Toxic and corrosive gases generally need more frequent testing.
  • CNG cylinders: CNG on-board cylinders, other CNG cylinders and auto LPG containers must also carry an expiry date marking.

What periodic testing involves

  • Evacuation and degassing of the residual gas safely
  • External and internal visual inspection for corrosion, dents, cuts, bulges and fire damage
  • Hydrostatic test – the cylinder is pressurised with water to its test pressure
  • Hydrostatic stretch test – for cylinders that need it, the permanent stretch at test pressure is measured and recorded
  • Valve inspection or replacement and checks of the markings
  • Condemnation of cylinders that fail

Indian Standards also lay down detailed procedures for periodic inspection of specific cylinder types. For example, IS 16017:2024 covers seamless aluminium alloy gas cylinders.

Marking after the test

After a successful test, the cylinder is marked with the date of the last hydrostatic or hydrostatic stretch test and the code mark of the recognised testing station. Each testing station’s code mark is registered with the Chief Controller of Explosives, so every test can be traced back to the station that did it.

Setting up a gas cylinder testing station

Any testing station that wants to be recognised for periodic testing must provide the facilities set out in Schedule IV and get approval from the Chief Controller of Explosives. PESO publishes separate lists of approved LPG cylinder testing stations, testing stations for gases other than LPG, and CNG cylinder testing stations.

Facilities a testing station must have

  • Facilities to evacuate and degas cylinders
  • Neutralisation or scrubbing facilities for toxic and corrosive gases, where such cylinders are tested
  • Hydrostatic or hydrostatic stretch test equipment with calibrated gauges
  • Internal inspection equipment
  • Facilities for condemning failed cylinders

Documents for approval

  • Application with the fee prescribed in Schedule V
  • Proposed location of the testing station
  • Site and layout plans showing the degassing area (for flammable gas cylinders) or neutralisation facilities (for toxic gas cylinders) and the location of the testing equipment
  • Details of the testing equipment and its calibration
  • Other documents listed in Rule 49 of the Gas Cylinders Rules 2016

Approval process

  1. Plan the station for the gases and cylinder types you want to test.
  2. Prepare drawings and equipment details as required under the Gas Cylinders Rules 2016.
  3. Apply online on the PESO portal or through the National Single Window System (NSWS) with the fee.
  4. Scrutiny and verification – PESO reviews the application and may verify the facilities.
  5. Approval and code mark – once approved, the station gets its code mark for marking tested cylinders.

Common reasons for delays

  • Layout plans that do not clearly show the degassing or neutralisation area
  • Test equipment without valid calibration
  • Applying for gases or cylinder types the station is not equipped to test
  • No proper facility for condemning failed cylinders

Frequently Asked Questions

How often must an LPG cylinder be tested?

Under the Gas Cylinders Rules 2016, an LPG cylinder must be re-tested 10 years after its date of manufacture, and every five years after that. Cylinders due for testing cannot be filled.

Can a gas filler test its own cylinders?

Only at a cylinder testing station approved by the Chief Controller of Explosives (PESO). A filler can set up its own testing station, but it must get PESO approval first.

What happens to a cylinder that fails the periodic test?

A cylinder that fails the periodic examination or test must be condemned so that it can never be used again. Approved testing stations must have facilities for condemning cylinders.

What marking is put on a cylinder after testing?

The cylinder is marked with the date of the last hydrostatic or hydrostatic stretch test and the code mark of the testing station that carried it out. The code mark must be registered with the Chief Controller.

Which documents are needed to apply for a cylinder testing station?

The application includes the fee, the proposed location, site and layout plans showing the degassing or neutralisation area and the position of testing equipment, and details of the testing facilities.

HS

Written by

BIS Certification Consultant, Qualitance India · 10+ years experience · 200+ products certified

Last updated: November 2026

Need help with BIS certification for this product?

Get a free consultation from our compliance experts — we handle testing, documentation and the complete BIS process for you.

Get Free Consultation +91 93106 15170
Free PDF Download

BIS Certification Readiness Checklist 2026

  • Documents, testing & factory requirements in one place
  • Covers ISI Mark, CRS, FMCS & Hallmarking
  • Tick-box format — share it with your team

Talk to us?