Latest Updates

BIS Certification for Lighters – Safety Specifications | IS/ISO 9994:2018

  • Home
  • Blogs
  • BIS Certification for Lighters – Safety Specifications |…
BIS Certification for Lighters – Safety Specifications | IS/ISO 9994:2018

BIS Certification for Lighters – Safety Specifications | IS/ISO 9994:2018

Introduction

Lighters are commonly used consumer products designed to generate a flame for lighting cigarettes, cigars and pipes. Although they are small and portable, improper design, manufacturing defects, fuel leakage or uncontrolled flame generation can create significant safety risks.

To address these risks, the Bureau of Indian Standards (BIS) has adopted IS/ISO 9994:2018 – Lighters: Safety Specifications, which establishes safety requirements for flame-producing lighters.

The standard specifies requirements relating to flame generation, flame height, flame extinction, fuel compatibility, resistance to dropping, elevated temperature, internal pressure, burning behaviour and other safety characteristics.

The Government of India has brought flame-producing lighters under mandatory BIS certification through the Flame-Producing Lighters (Quality Control) Order, 2023.

Manufacturers and importers dealing with lighters covered by the QCO must understand the applicable product standard, certification scope, testing requirements and current exemptions before manufacturing or placing products on the Indian market.

2. BIS Certification and Mandatory Requirements

The Department for Promotion of Industry and Internal Trade (DPIIT), Ministry of Commerce and Industry, issued the Flame-Producing Lighters (Quality Control) Order, 2023 through S.O. 2986(E), dated 5 July 2023.

The order covers two categories of products:

  1. Lighters conforming to IS/ISO 9994:2018.
  2. Utility Lighters conforming to IS/ISO 22702:2018.

This article specifically addresses ordinary lighters covered under IS/ISO 9994:2018.

Particular Details
Product Lighters
Applicable Indian Standard IS/ISO 9994:2018
Standard title Lighters – Safety Specifications
QCO Flame-Producing Lighters (Quality Control) Order, 2023
Original notification S.O. 2986(E), dated 5 July 2023
Certification scheme BIS Scheme-I
Certification mark BIS Standard Mark (ISI Mark)
Certification authority Bureau of Indian Standards
Applicable product category Flame-producing lighters

2.1 Implementation timeline

The original QCO prescribed different implementation periods for enterprises based on their classification.

Enterprise category Original implementation period
General manufacturers 6 months from notification
Small enterprises 9 months from notification
Micro enterprises 12 months from notification

The QCO was notified on 5 July 2023. The respective implementation periods have elapsed.

2.2 Latest exemption provision – 2026 amendment

The Government issued the Flame-Producing Lighters (Quality Control) Amendment Order, 2024, through S.O. 4230(E), dated 20 September 2024, and subsequently issued a further amendment through S.O. 777(E), dated 12 February 2026.

The 2026 amendment provides an exemption for goods or articles manufactured by an enterprise satisfying all the following conditions:

  • The enterprise must be registered on the Udyam Portal of the Ministry of MSME.
  • Investment in plant and machinery or equipment, at original cost, must not exceed ₹1 crore.
  • Turnover for the previous financial year must not exceed ₹5 crore.
  • The investment and turnover conditions must be certified by a Chartered Accountant.

This exemption is subject to the exact wording and applicability of the amended QCO. Manufacturers and importers should not assume that every MSME or Udyam-registered enterprise is automatically exempt.

The 2024 amendment also provided a six-month transitional period for declared pre-existing stock manufactured or imported before commencement of the QCO, subject to a CA-certified declaration to BIS. This transitional period has expired.

Important: The 2026 exemption is based on specified Udyam registration, investment and turnover conditions. A manufacturer should verify its eligibility before relying on the exemption.

3. Applicable Indian Standard – IS/ISO 9994:2018

IS/ISO 9994:2018 specifies safety requirements for lighters to provide a reasonable degree of safety during normal use and reasonably foreseeable misuse.

The international standard applies to flame-producing products commonly known as:

  • Cigarette lighters.
  • Cigar lighters.
  • Pipe lighters.

It does not cover matches or flame-producing products intended solely for igniting materials other than cigarettes, cigars and pipes.

Important distinction:

Product category Applicable Indian Standard
Cigarette, cigar and pipe lighters IS/ISO 9994:2018
Utility lighters IS/ISO 22702:2018

Utility lighters are covered by a separate safety specification. A manufacturer should identify the correct product category before applying for BIS certification.

4. Product Description and Types of Lighters

IS/ISO 9994:2018 covers different types of fluid and gas lighters.

The BIS Product Manual PM/IS/ISO 9994/3, February 2024, identifies the following classifications for licensing and grouping.

S. No. Classification Types
1 Fuel type Fluid lighter / Gas lighter
2 Burner arrangement Post-mixing burner / Premixing burner
3 Flame adjustment Adjustable / Non-adjustable / Automatically adjusting pipe lighter
4 Flame extinction Self-extinguishing / Non-self-extinguishing
5 Refillability Refillable / Non-refillable (Disposable)
6 Flame configuration Dual flame type
7 Flame configuration Multiple flame type

These classifications form an important part of the BIS licence scope.

Manufacturers must identify the varieties they intend to manufacture and include in their application.

5. Scope of BIS Licence

As per the BIS Product Manual PM/IS/ISO 9994/3, February 2024, the licence is granted for the product category Lighters with the declared applicable types.

The licence scope may include:

Scope parameter Details
Product name Lighters
Standard IS/ISO 9994:2018
Fuel type Fluid / Gas
Burner type Post-mixing / Premixing
Refillability Refillable / Disposable
Flame adjustment Adjustable / Non-adjustable / Automatically adjusting pipe lighter
Flame extinction Self-extinguishing / Non-self-extinguishing
Flame configuration Dual flame / Multiple flame

The manufacturer must declare all varieties intended to be covered under the licence.

BIS may restrict the scope depending on the manufacturer’s manufacturing and testing capabilities.

6. Technical Requirements and Safety Parameters

IS/ISO 9994:2018 specifies functional and structural-integrity requirements to ensure safe operation of lighters.

The major requirements are grouped into two categories.

6.1 Functional requirements

These requirements assess the lighter’s flame generation and operational behaviour.

S. No. Test parameter Relevant clause
1 Flame generation 4.1
2 Flame heights 4.2
3 Flame-height adjustment 4.3
4 Resistance to spitting or sputtering and flaring 4.4
5 Flame extinction 4.5
6 Volumetric displacement 4.6
7 Mass of fuel 4.7

6.2 Structural-integrity requirements

These requirements evaluate the physical integrity and safety of the lighter under specified conditions.

S. No. Test parameter Relevant clause
1 External finish 5.1
2 Compatibility with fuel 5.2
3 Resistance to fuel loss 5.3
4 Resistance to dropping 5.4
5 Resistance to elevated temperature 5.5
6 Resistance to internal pressure 5.6
7 Burning behaviour 5.7
8 Resistance to cyclic burning 5.8
9 Resistance to continuous burning 5.9

The manufacturer must demonstrate conformity with all applicable requirements of IS/ISO 9994:2018, including the prescribed test methods and acceptance criteria.

7. Testing Requirements for BIS Certification

Product testing is a critical part of the BIS certification process.

The lighter must undergo the applicable functional and structural-integrity tests to establish conformity with IS/ISO 9994:2018.

7.1 Flame generation test

This test evaluates whether the lighter generates a flame in accordance with the requirements of the standard.

It is one of the important functional tests for establishing the operational performance of the lighter.

7.2 Flame height test

The test evaluates the flame height produced by the lighter under the specified test conditions.

7.3 Flame-height adjustment test

This test verifies the performance of the flame adjustment mechanism, where applicable.

7.4 Resistance to spitting, sputtering and flaring

This test evaluates undesirable flame behaviour during operation.

7.5 Flame extinction test

The test evaluates whether the flame extinguishes in accordance with the requirements of the applicable lighter type.

7.6 Volumetric displacement test

This test evaluates the volumetric displacement characteristics of the lighter as specified in the standard.

7.7 Mass of fuel

The mass of fuel is checked against the applicable requirements for the lighter.

7.8 Compatibility with fuel

The test evaluates the compatibility of the lighter with its specified fuel under the prescribed conditions.

7.9 Resistance to fuel loss

This test evaluates the lighter’s resistance to fuel loss during the specified test procedure.

7.10 Resistance to dropping

The lighter is evaluated for its ability to withstand the specified dropping test without unacceptable failure.

7.11 Resistance to elevated temperature

The test assesses the lighter’s performance when exposed to the prescribed elevated-temperature conditions.

7.12 Resistance to internal pressure

The test evaluates the structural integrity of the lighter under the specified internal-pressure conditions.

7.13 Burning behaviour

This test evaluates the lighter’s burning characteristics against the requirements specified in the standard.

7.14 Resistance to cyclic and continuous burning

These tests evaluate the lighter’s behaviour under the specified cyclic and continuous burning conditions.

Note: The actual test procedures, conditioning requirements, test limits and acceptance criteria must be followed as prescribed in the full text of IS/ISO 9994:2018.

8. Sample Quantity and Grouping Guidelines

The BIS Product Manual PM/IS/ISO 9994/3, February 2024, provides specific sample and grouping requirements.

8.1 Sample quantity

Particular Requirement
Product Lighters
Sample quantity 10 lighters
Purpose Grant of Licence / Change in Scope of Licence
Sampling guidelines As per Annex A of the Product Manual

The sample quantity specified in the Product Manual is 10 lighters.

8.2 Grouping guidelines

The BIS Product Manual identifies the following classification factors:

  1. Fluid lighter / Gas lighter.
  2. Post-mixing burner / Premixing burner.
  3. Adjustable / Non-adjustable / Automatically adjusting pipe lighter.
  4. Self-extinguishing / Non-self-extinguishing.
  5. Refillable / Non-refillable (Disposable).
  6. Dual flame type.
  7. Multiple flame type.

8.3 Important grouping provisions

  • Each type of lighter, irrespective of reservoir capacity, must be tested for all applicable requirements to cover all reservoir capacities of that particular type.
  • The manufacturer must declare all varieties intended to be covered under the licence.
  • The scope of the licence may be restricted based on manufacturing and testing capabilities.
  • During licence operation, BIS will ensure that all varieties covered under the licence are tested in rotation, to the extent possible.

8.4 Practical grouping example

Suppose a manufacturer produces the following products:

Product Fuel type Burner type Refillable status Flame type
Model A Gas Premixing Disposable Single flame
Model B Gas Premixing Refillable Single flame
Model C Fluid Not applicable Refillable Single flame
Model D Gas Post-mixing Refillable Dual flame

Each product variety must be assessed against the grouping guidelines.

The grouping of reservoir capacities is permitted for a particular type after testing that type for all applicable requirements. Different lighter types cannot automatically be covered by a single test merely because they have a similar appearance.

Final sample selection and licence scope remain subject to BIS assessment.

9. Laboratory and Testing Equipment Requirements

The manufacturer must maintain suitable testing arrangements to establish conformity with IS/ISO 9994:2018.

The BIS Product Manual provides an indicative list of major equipment required for testing.

S. No. Test parameter Major equipment
1 Flame generation Rotary actuator / Push-button actuator
2 Flame heights Vertically supported non-flammable board, draught-free chamber
3 Flame extinction Digital thermometer, stopwatch, measuring scale or flame-height measurement apparatus
4 Resistance to spitting, sputtering and flaring Digital thermometer, stopwatch, measuring scale
5 Volumetric displacement Weighing balance, drilling machine, drill bit, syringe, digital thermometer, stopwatch
6 Compatibility with fuel Container, enclosures, digital thermometer, weighing balance, hot-air oven, stopwatch
7 Resistance to fuel loss Stopwatch and weighing balance
8 Resistance to dropping Concrete surface, freezer, hot-air oven, weighing balance and height gauge
9 Resistance to elevated temperature Hot-air oven, weighing balance, enclosures and digital thermometer
10 Resistance to internal pressure Pressure-generating device, pressure gauge and pressure-regulating device
11 Burning behaviour Stopwatch, measuring scale, protractor or arrangement for angle measurement, flame-height measurement apparatus
12 Resistance to cyclic burning Digital thermometer and stopwatch
13 Resistance to continuous burning Draught-free chamber, digital thermometer, stopwatch and measuring scale

An air conditioner is also included in the indicative equipment list for maintaining laboratory ambient conditions.

The list is indicative and not exhaustive. The manufacturer must review the complete Product Manual and applicable test methods before finalising the laboratory setup.

9.1 In-house and subcontracted testing

The BIS Product Manual classifies tests into two categories:

  • R – Routine tests: Testing equipment is required in-house.
  • S – Subcontracting permitted: Testing may be carried out through eligible external laboratories.

The general requirements are:

For large-scale manufacturers:

  • In-house laboratory facilities must be maintained for routine tests identified as R.
  • A calibration plan for in-house equipment must be implemented.
  • Sharing of testing facilities may be used as permitted under BIS guidelines.

For MSME manufacturers:

  • Maintaining an in-house facility for routine tests identified as R is optional.
  • Common cluster-based testing facilities may be utilised.
  • Shared testing facilities or eligible external laboratories may be used.
  • Subcontracted tests must be carried out through BIS-recognised or empanelled laboratories, or laboratories holding valid NABL accreditation as per IS/ISO/IEC 17025.

10. Scheme of Inspection and Testing (SIT)

The BIS Product Manual provides a Scheme of Inspection and Testing in Annex-C.

Manufacturers must implement a Quality Assurance Plan to ensure that products bearing the Standard Mark conform to all requirements of IS/ISO 9994:2018.

10.1 Quality Assurance Plan

The Quality Assurance Plan should define:

  • Control unit or batch.
  • Inspection and testing parameters.
  • Number of samples.
  • Frequency of testing.
  • In-process controls.
  • Records to be maintained.
  • Arrangements for subcontracted testing.

The manufacturer must submit the Quality Assurance Plan to the concerned BIS Branch Office for information.

10.2 Control unit

As per the BIS Product Manual, the recommended control unit is:

The quantity of all lighters of the same type manufactured in one day.

10.3 Recommended levels of control

The Product Manual specifies the following recommended testing frequencies:

Test parameter Equipment category Sample quantity Frequency
Flame generation R 5 lighters Each control unit
Flame heights R 2 lighters Once a month
Flame-height adjustment R 2 lighters Once a month
Resistance to spitting, sputtering and flaring R 2 lighters Once a month
Flame extinction R 2 lighters Once a month
Volumetric displacement R 2 lighters Once a month
Mass of fuel R 1 gas lighter Each consignment of gas lighter shipped with fuel
External finish R Whole production control Continuous quality control and records
Compatibility with fuel S 5 lighters Once in three months
Resistance to fuel loss R 2 lighters Once a month
Resistance to dropping R 2 lighters Once a month
Resistance to elevated temperature R 2 lighters Once a month
Resistance to internal pressure R 2 lighters Once a month
Burning behaviour R 2 lighters Once a month
Resistance to cyclic burning R 2 lighters Once a month
Resistance to continuous burning R 2 lighters Once a month

Important: For the monthly structural-integrity tests, the manufacturer must plan testing so that every type produced during the month is covered. For compatibility with fuel, every type produced during the three-month period must be covered.

The manufacturer may define its own justified Quality Assurance Plan and control unit, subject to the provisions of the Product Manual.

10.4 Test records and calibration

The manufacturer must maintain:

  • In-house testing records.
  • Calibration records.
  • Batch and control-unit records.
  • Production inspection records.
  • Subcontracted laboratory test reports.
  • Records of rejected and non-conforming products.

Reports from subcontracted laboratories must be made available for inspection by BIS.

11. Marking and Labelling Requirements

After obtaining a BIS licence, the manufacturer must ensure that each conforming lighter carries the BIS Standard Mark.

As per the BIS Product Manual:

  1. The Standard Mark must be marked on each lighter.
  2. The lighter must conform to all applicable requirements of IS/ISO 9994:2018.
  3. The BIS licence number must be marked at an appropriate place.
  4. The BIS website reference must be included.

The additional marking requirement is:

“For details of BIS certification please visit www.bis.gov.in”

The licence number must be mentioned in the prescribed format:

CM/L-XXXXXXXXXX

Only products covered under the valid BIS licence and conforming to the applicable standard may carry the Standard Mark.

12. Documents Required for BIS Certification

Manufacturers should prepare the following documents before submitting their BIS application.

S. No. Document Purpose
1 Business registration certificate Legal identity of the applicant
2 PAN card Business identification
3 GST registration certificate Tax registration
4 Factory address proof Verification of manufacturing premises
5 Factory layout plan Details of manufacturing and laboratory areas
6 Manufacturing process flow chart Description of production operations
7 List of manufacturing machinery Verification of manufacturing capability
8 List of testing equipment Verification of testing facilities
9 Calibration certificates Calibration status of equipment
10 Product specifications Details of lighter models and types
11 Fuel details Identification of fuel used
12 Product drawings and photographs Product identification
13 Quality Assurance Plan Testing and inspection arrangements
14 In-house test records Evidence of product quality control
15 Subcontract testing arrangements Details of external testing facilities
16 Product marking and packaging details Verification of proposed BIS marking
17 Authorized signatory documents Applicant authorization
18 Application forms and undertakings BIS application requirements

The exact documentation requirements may vary depending on the applicant’s business constitution, manufacturing arrangement and the latest BIS application procedure.

13. BIS Certification Procedure for Lighters

The BIS certification process generally involves the following stages.

Step 1 – Product identification

Identify whether the product is a cigarette, cigar or pipe lighter covered by IS/ISO 9994:2018.

Step 2 – Applicable standard confirmation

Confirm the applicable standard and distinguish ordinary lighters from utility lighters covered under IS/ISO 22702:2018.

Step 3 – Product scope finalisation

Identify the fuel type, burner type, refillability, flame adjustment mechanism, flame extinction characteristics and flame configuration.

Step 4 – Manufacturing facility assessment

Review the manufacturing process, machinery, assembly operations and quality control arrangements.

Step 5 – Laboratory readiness

Assess the required in-house testing equipment, external testing arrangements, calibration status and personnel competency.

Step 6 – Documentation preparation

Prepare the manufacturing documents, product specifications, Quality Assurance Plan and supporting application documents.

Step 7 – BIS application submission

Submit the application under Scheme-I through the applicable BIS online certification process.

Step 8 – Factory inspection

BIS officials assess the manufacturing facility, product scope, laboratory, quality control system and conformity with the Indian Standard.

Step 9 – Sample drawing and testing

Samples are drawn in accordance with the BIS Product Manual and tested against the applicable requirements of IS/ISO 9994:2018.

Step 10 – Compliance and grant of licence

After satisfactory inspection, testing and fulfilment of applicable certification requirements, BIS processes the application for grant of licence.

Step 11 – Use of BIS Standard Mark

After the licence is granted, the manufacturer may mark conforming products covered under the licence with the BIS Standard Mark.

14. Common Challenges in BIS Certification

Manufacturers may face several technical and procedural challenges while obtaining BIS certification for lighters.

14.1 Incorrect product classification

Manufacturers may confuse ordinary cigarette lighters with utility lighters. The applicable Indian Standard must be correctly identified before applying.

14.2 Inadequate flame performance

Flame generation, flame height and flame extinction must meet the specified requirements. Variations in the burner assembly or fuel system can affect test results.

14.3 Fuel compatibility issues

The lighter must demonstrate compatibility with its specified fuel under the applicable test conditions.

14.4 Fuel leakage and internal pressure

Failure in fuel-loss or internal-pressure tests can create safety and certification issues.

14.5 Dropping and elevated-temperature performance

The product must maintain the required structural integrity under the prescribed test conditions.

14.6 Inadequate laboratory arrangements

Manufacturers must identify which tests require in-house facilities and which may be subcontracted under the Product Manual.

14.7 Incorrect grouping of lighter varieties

Different fuel types, burner arrangements, refillability and flame configurations must be properly declared. Grouping cannot be based only on external appearance.

14.8 Incomplete SIT and test records

A manufacturer must maintain a suitable Quality Assurance Plan, control-unit records, calibration records and routine test reports.

15. How Qualitance India Can Help

Qualitance India provides BIS certification consultancy and regulatory compliance support to manufacturers and importers dealing with products covered under compulsory BIS certification.

For lighters under IS/ISO 9994:2018, our support can include:

  • BIS applicability assessment under the Flame-Producing Lighters QCO.
  • Review of IS/ISO 9994:2018 requirements.
  • Identification of applicable lighter varieties.
  • Product scope and grouping assessment.
  • Preparation of BIS application documentation.
  • Manufacturing process and quality control review.
  • Laboratory and testing equipment gap assessment.
  • Preparation of Quality Assurance Plan and SIT documentation.
  • Coordination for sample testing.
  • Support during BIS factory inspection.
  • Assistance in resolving testing and inspection non-conformities.
  • Support for BIS licence grant and subsequent compliance.

Qualitance India – Improving Quality & Competence

For BIS certification consultancy and technical assistance:

Website: https://qualitanceindia.com
Email: info@qualitanceindia.com
Contact: +91 93106 15170

16. Frequently Asked Questions (FAQs)

Q1. Is BIS certification mandatory for lighters in India?

Yes. Flame-producing lighters covered under the Flame-Producing Lighters (Quality Control) Order, 2023 must conform to the applicable Indian Standard and bear the BIS Standard Mark under a valid licence, subject to the applicable exemptions.

Q2. Which Indian Standard is applicable to cigarette lighters?

IS/ISO 9994:2018 – Lighters: Safety Specifications.

Q3. Is IS/ISO 9994:2018 applicable to utility lighters?

No. Utility lighters are covered separately under IS/ISO 22702:2018.

Q4. What is the sample quantity required for BIS certification?

As per the BIS Product Manual PM/IS/ISO 9994/3, February 2024, the sample size is 10 lighters.

Q5. What types of lighters are covered under IS/ISO 9994:2018?

The Product Manual identifies fluid and gas lighters, post-mixing and premixing burner types, refillable and disposable lighters, adjustable and non-adjustable lighters, self-extinguishing and non-self-extinguishing lighters, dual flame and multiple flame types.

Q6. Can different reservoir capacities be covered under one test?

Yes. The Product Manual specifies that each type of lighter, irrespective of reservoir capacity, must be tested for all applicable requirements to cover all reservoir capacities of that particular type.

Q7. Is an in-house laboratory mandatory?

Large-scale manufacturers must maintain in-house facilities for routine tests identified as R, subject to permitted shared testing facility arrangements. For MSME manufacturers, maintaining an in-house facility for these routine tests is optional. Eligible cluster-based, shared or external laboratory facilities may be used in accordance with the Product Manual.

Q8. Which tests are required for BIS certification of lighters?

Major tests include flame generation, flame height, flame-height adjustment, resistance to spitting and sputtering, flame extinction, volumetric displacement, fuel compatibility, fuel-loss resistance, dropping, elevated temperature, internal pressure and burning behaviour.

Q9. What is the control unit for lighters?

The recommended control unit is the quantity of all lighters of the same type manufactured in one day.

Q10. What is the marking requirement after BIS licence grant?

Each conforming lighter must carry the BIS Standard Mark, the applicable CM/L licence number and the prescribed BIS website reference.

Q11. Are small manufacturers exempt from BIS certification?

Not every small manufacturer is automatically exempt. The 2026 amendment provides an exemption for eligible Udyam-registered enterprises meeting the specified investment ceiling of ₹1 crore and previous financial-year turnover ceiling of ₹5 crore, supported by a Chartered Accountant’s certification.

Q12. Can imported lighters be sold in India without BIS certification?

Imported products covered by the QCO are subject to the applicable certification requirements. Importers should verify the valid BIS licence and the manufacturer’s certification scope before importing products for the Indian market.

17. Conclusion

BIS certification for lighters under IS/ISO 9994:2018 is an important regulatory requirement for ensuring the safety and reliability of flame-producing consumer products.

Manufacturers must carefully evaluate product classification, fuel type, burner configuration, flame performance, fuel compatibility, structural integrity, laboratory requirements and the Scheme of Inspection and Testing before applying for a BIS licence.

The BIS Product Manual PM/IS/ISO 9994/3, February 2024, provides the applicable sample size, grouping guidelines, testing equipment requirements and recommended levels of control.

A systematic approach to product testing, manufacturing controls, documentation and laboratory readiness can help manufacturers prepare effectively for BIS factory inspection and certification.

Qualitance India supports manufacturers with BIS certification consultancy, technical documentation, laboratory readiness and regulatory compliance assistance.


HS

Written by

BIS Certification Consultant, Qualitance India · 10+ years experience · 200+ products certified

Last updated: November 2026

Need help with BIS certification for this product?

Get a free consultation from our compliance experts — we handle testing, documentation and the complete BIS process for you.

Get Free Consultation +91 93106 15170
Free PDF Download

BIS Certification Readiness Checklist 2026

  • Documents, testing & factory requirements in one place
  • Covers ISI Mark, CRS, FMCS & Hallmarking
  • Tick-box format — share it with your team

Talk to us?